• 제목/요약/키워드: steel fiber ratio

검색결과 507건 처리시간 0.029초

고강도 RC 기둥의 전단능력 증진을 위한 강섬유 보강 (Steel Fiber Reinforcement for Shear Capacity Enhancement of High Strength RC Columns)

  • 장극관;이현호;문상덕
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.469-474
    • /
    • 2002
  • This study was to define the strengthening effect of steel fibers in high strength RC columns. For this, ten specimens of columns were tested under cyclic lateral load and constant axial load. The testing parameters are steel fiber volume fraction of concrete and shear reinforcement ratio of hoop bars. Finally, the optimal content of steel fibers was evaluated as 1.0 - 1.5 % volume fraction of concrete.

  • PDF

이종 섬유 혼입비에 따른 섬유보강 콘크리트의 휨 인성 및 휨 인장강도에 관한 연구 (Study on flexural toughness and flexural tensile strength of fiber reinforced concrete by mixture ratio of different fibers)

  • 박홍용;류종현;조용범
    • 한국터널지하공간학회 논문집
    • /
    • 제12권1호
    • /
    • pp.51-60
    • /
    • 2010
  • 최근 새로운 형태의 폴리올레핀 섬유에 대하여 성능향상 개발이 이루어지고 있으며, 기존 섬유와 혼입하여 사용하거나 폴리올레핀 섬유만을 사용한 콘크리트 특성에 대하여 연구와 검증이 필요하다. 본 연구의 목적은 강섬유와 폴리올레핀 섬유를 사용한 콘크리트의 휨 인성 및 휨 인장강도에 대한 성능을 확인하기 위하여 324개의 보 시편을 제작하고, KS F2566과 ASTM C 1399-02규격에서 제시한 4점 휨 실험을 수행하여 휨 인성지수, 등가 휨 인장강도, 평균잔류강도를 분석하였다. 실험결과, 섬유 혼입률, 섬유 형상비에 대한 휨 인성 및 인장강도에 대한 효과가 확인되었으며, 강섬유와 폴리올레핀의 최적의 혼입비율을 제시하였다.

전단보강근이 없는 강섬유 보강 합성보의 강도 및 연성 능력 (Strength and Ductility of Steel Fiber Reinforced Composite Beams without Shear Reinforcements)

  • 오영훈;남영길;김정해
    • 콘크리트학회논문집
    • /
    • 제19권1호
    • /
    • pp.103-111
    • /
    • 2007
  • 본 연구는 강섬유 보강 콘크리트와 앵글을 사용한 합성보의 구조성능을 평가하고자 실험 연구를 수행하였다. 이러한 목적으로 일반 RC보와 강섬유가 혼입된 RC보, 그리고 강섬유 보강 합성보로 구성된 총 7개의 실험체를 제작하였으며, 모든 실험체에는 별도의 전단보강을 하지 않았다. 실험체의 주요 변수는 강섬유의 혼입률과 인장보강근비이며, 합성보의 강도 예측식의 평가와 실험 결과로부터 합성보의 강도, 강성, 연성능력, 에너지소산능력 등의 구조 성능을 평가하였다. 실험 결과들을 평가한 결과, 합성보의 공칭강도 산정식은 매우 정확한 예측이 가능하였으며, 휨균열강도 예측식은 강섬유 보강 효과의 고려가 필요하다고 판단되었다. 강섬유 체적비는 실험체의 강도와 연성 능력, 그리고 에너지소산 능력을 모두 증가시키는 것으로 나타났다. 인장보강근비와 유효인장보강근비의 증가는 실험체의 최대강도 증가에는 효과가 있지만, 반면에 연성 능력과 에너지소산 능력은 일정 수준을 초과하면 연성 능력과 에너지소산 능력이 저하하는 것으로 나타나고 있으므로 적절한 인장보강근비와 유효인장보강근비가 적용될 수 있도록 제한할 필요성이 있다고 판단된다.

강섬유와 PVA 섬유로 하이브리드 보강된 콘크리트의 슬럼프 및 역학적 특성 (Slump and Mechanical Properties of Hybrid Steel-PVA Fiber Reinforced Concrete)

  • 양근혁
    • 콘크리트학회논문집
    • /
    • 제22권5호
    • /
    • pp.651-658
    • /
    • 2010
  • 콘크리트의 슬럼프와 역학적특성에 대한 마이크로 섬유와 매크로 섬유의 영향을 파악하기 위하여 강섬유와 PVA 섬유로 하이브리드 보강된 콘크리트 16배합과 무보강 콘크리트 1배합을 실험하였다. 주요 변수는 강섬유와 PVA 섬유의 체적비 및 길이이다. 하이브리드 섬유보강 콘크리트의 역학적특성들은 섬유보강지수에 따라 분석되었으며, 강섬유 또는 PVA 섬유만으로 보강된 콘크리트와 비교하였다. 하이브리드 섬유보강 콘크리트의 슬럼프는 섬유 체적비와 형상비 증가와 함께 감소하였으며, 할렬인장강도, 파괴계수, 탄성계수 및 휨 인성지수는 섬유보강지수의 증가와 함께 증가하였다. 단일 섬유보강 콘크리트의 섬유체적비에 비해 낮은 체적비를 갖는 하이브리드 섬유보강 콘크리트의 파괴계수와 휨인성지수는 단일 섬유보강 콘크리트에 비해 높았다. 하이브리드 섬유보강 콘크리트의 휨 인성 향상을 위해서는 30 mm와 60 mm 길이의 강섬유를 함께 사용하는 것보다는 60 mm 강섬유만을 사용하는 것이 효율적이었다.

재료요인이 초고강도 강섬유 보강 시멘트 복합체의 압축강도에 미치는 영향 (The effect of material factors on the compressive strength of ultra-high strength Steel Fiber Reinforced Cementitious Composites)

  • 박정준;고경택;강수태;류금성;김성욱;이장화
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.288-291
    • /
    • 2004
  • In this paper, to make ultra-high strength SFRCC with the range of compressive strength 180MPa, it was investigated the constitute factors of ultra-high strength SFRCC influenced on the compressive strength. The experimental variables were water-cementitious ratio, replacement of silica fume, size and proportion of sand, type and replacement of filling powder, and using of steel fiber in ultra-high strength SFRCC. As a result, in water-binder ratio 0.18, we could make ultra-high strength SFRCC with compressive strength 180MPa through using of silica fume, quartz sand with below 0.5mm, filling powder and steel fiber.

  • PDF

Earthquake resistance of structural walls confined by conventional tie hoops and steel fiber reinforced concrete

  • Eom, Taesung;Kang, Sumin;Kim, Okkyue
    • Earthquakes and Structures
    • /
    • 제7권5호
    • /
    • pp.843-859
    • /
    • 2014
  • In the present study, the seismic performance of structural walls with boundary elements confined by conventional tie hoops and steel fiber concrete (SFC) was investigated. Cyclic lateral loading tests on four wall specimens under constant axial load were performed. The primary test parameters considered were the spacing of boundary element transverse reinforcement and the use of steel fiber concrete. Test results showed that the wall specimen with boundary elements complying with ACI 318-11 21.9.6 failed at a high drift ratio of 4.5% due to concrete crushing and re-bar buckling. For the specimens where SFC was selectively used in the plastic hinge region, the spalling and crushing of concrete were substantially alleviated. However, sliding shear failure occurred at the interface of SFC and plain concrete at a moderate drift ratio of 3.0% as tensile plastic strains of longitudinal bars were accumulated during cyclic loading. The behaviors of wall specimens were examined through nonlinear section analysis adopting the stress-strain relationships of confined concrete and SFC.

휨을 받는 강섬유 보강 고강도철근 콘크리트 보의 구조 거동 (Structural Behavior of Steel Fiber-Reinforced Concrete Beams with High-Strength Rebar Subjected to Bending)

  • 양인환;김경철;조창빈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권3호
    • /
    • pp.93-102
    • /
    • 2016
  • 이 논문의 목적은 압축강도 130 MPa급의 고강도 강섬유 보강 콘크리트 보의 휨거동 특성을 파악하는데 있다. 부피비 1.0%의 강섬유와 철근비 0.02 이하의 철근으로 보강된 고강도 강섬유 보강 콘크리트의 휨거동 특성 실험결과를 제시하였다. 일반강도철근과 고강도철근을 실험 부재에 사용하였다. 강섬유 보강 콘크리트의 압축 및 인장거동 재료 실험과 모델링을 수행하였다. 강섬유 보강 콘크리트의 하중-균열개구변위 실험결과를 반영하여 가상균열모델에 근거한 역해석을 통해 인장거동모델링을 제시하였다. 실험결과는 강섬유 보강 콘크리트와 고강도철근의 사용은 균열제어 및 연성 거동에 유리한 것을 나타낸다. 일반강도철근을 사용한 보의 휨강도 실험값에 대한 수치해석에 의한 예측값의 비는 0.81~1.42를 나타내고, 고강도철근을 사용한 보의 휨강도 실험값에 대한 수치해석에 의한 예측값의 비는 0.92~1.07을 나타낸다. 수치해석에 의한 휨강도는 실험결과를 합리적으로 예측하고 있는 것으로 판단된다.

강섬유 보강콘크리트의 강섬유 분산이 표면전기저항에 미치는 영향 (Effect of Steel Fiber Distribution in Steel Fiber-reinforced Concrete on Surface Electrical Resistivity)

  • 김성도;문도영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.106-113
    • /
    • 2013
  • 콘크리트의 투수성능을 평가하는 여러 가지 비파괴시험방법 중의 하나는 표면전기저항을 측정하는 것이다. 그러나 콘크리트내에 강섬유로 인한 판단의 오류가 발생할 수 있기 때문에 강섬유 보강콘크리트에 본 표면전기저항측정방법을 적용하기에는 한계가 있다. 본 연구에서는 강섬유보강 콘크리트의 강섬유 분산도가 표면전기저항에 미치는 영향을 실험적으로 고찰하였다. 3개의 정방형 및 원형 실험체의 4개면에서의 저항치를 3번 반복하여 측정하였으며, 서로 비교하였다. 측정결과에 의하면, 원형실험체를 이용한 실험결과가 정방형 실험체의 결과에 비하여 강섬유의 영향을 일관되게 나타내고 있는 것으로 확인되었다. 또한, 강섬유의 분산도는 강섬유 혼입량에 비하여 측정결과에 미치는 영향이 미미한 것으로 나타났다. 결론적으로, 표면전기저항측정을 이용한 비파괴 평가법은 0.5%까지의 강섬유를 포함한 SFRC의 투수성 평가에 적용될 수 있는 것으로 판단된다.

보강섬유의 종류에 따른 섬유보강 콘크리트의 휨특성 (Flexural Behavior of Fiber-Reinforced Concrete by Fiber Types)

  • 강영태;김규용;이보경;이상규;김경태;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.15-16
    • /
    • 2017
  • In this study, the flexural behavior of fiber-reinforced concrete by fiber type were evaluated. As a result, the flexural strength of the hooked steel fiber-reinforced concrete(HSFRC) was lower than that of the amorphous metallic fiber reinforced concrete(AFRC), however it was shown strain-softening behavior by the pull-out of fiber. The flexural strength and the equivalent flexural strength of polyamide fiber-reinforced concrete(PAFRC) were lower than other specimens, but the equivalent flexural strength ratio was similar to that of AFRC. The flexural behavior of the fiber-reinforced concrete was associated with the bonding and pull-out properties of the fiber and matrix depending on the fiber type.

  • PDF

섬유 혼입 비율에 따른 하이브리드 섬유보강 콘크리트의 재료특성 (Effect of Fiber Blending on Material Property of Hybrid Fiber Reinforced Concrete)

  • 김학연;서기원;이욱재;김남호;박춘근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.345-348
    • /
    • 2004
  • In this study, an effect of fiber blending on material property of hybrid fiber reinforced concrete (HFRC) was evaluated. Also, optimized association and the mixing rate of fiber for HFRC was determined. Test result shows, in the case of mono fiber reinforced concrete, use of steel fiber in concrete caused increment in tensile and bending strength as the blended ratio increases, while use of carbon fiber and glass fiber caused increment in compressive strength. Use of hybrid fiber reinforcement in concrete caused a significant influence on its fracture behavior; consequently, caused increase by mixing rate of steel fiber and contributed by carbon fiber, glass fiber, celluloid fiber in reinforcement effect in order.

  • PDF