Reinforced concrete structures with damped seismic buckling-restrained bracing optimization using multi-objective evolutionary niching ChOA

  • Shouhua Liu;Jianfeng Li;Hamidreza Aghajanirefah;Mohammad Khishe;Abbas Khishe;Arsalan Mahmoodzadeh;Banar Fareed Ibrahim
    • Steel and Composite Structures
    • /
    • 제47권2호
    • /
    • pp.147-165
    • /
    • 2023
  • The paper contrasts conventional seismic design with a design that incorporates buckling-restrained bracing in three-dimensional reinforced concrete buildings (BRBs). The suboptimal structures may be found using the multi-objective chimp optimization algorithm (MEN-ChOA). Given the constraints and dimensions, ChOA suffers from a slow convergence rate and tends to become stuck in local minima. Therefore, the ChOA is improved by niching and evolutionary operators to overcome the aforementioned problems. In addition, a new technique is presented to compute seismic and dead loads that include all of a structure's parts in an algorithm for three-dimensional frame design rather than only using structural elements. The performance of the constructed multi-objective model is evaluated using 12 standard multi-objective benchmarks proposed in IEEE congress on evolutionary computation. Second, MEN-ChOA is employed in constructing several reinforced concrete structures by the Mexico City building code. The variety of Pareto optimum fronts of these criteria enables a thorough performance examination of the MEN-ChOA. The results also reveal that BRB frames with comparable structural performance to conventional moment-resistant reinforced concrete framed buildings are more cost-effective when reinforced concrete building height rises. Structural performance and building cost may improve by using a nature-inspired strategy based on MEN-ChOA in structural design work.

Slab panel vertical support and tensile membrane action in fire

  • Abu, Anthony K.;Burgess, Ian W.;Plank, Roger J.
    • Steel and Composite Structures
    • /
    • 제8권3호
    • /
    • pp.217-230
    • /
    • 2008
  • The increasing use of performance-based approaches in structural fire engineering design of multi-storey composite buildings has prompted the development of various tools to help quantify the influence of tensile membrane action in composite slabs at elevated temperatures. One simplified method which has emerged is the Bailey-BRE membrane action method. This method predicts slab capacities in fire by analysing rectangular slab panels supported on edges which resist vertical deflection. The task of providing the necessary vertical support, in practice, requires protecting a panel's perimeter beams to achieve temperatures of no more than $620^{\circ}C$ at the required fire resistance time. Hence, the integrity of this support becomes critical as the slab and the attached beams deflect, and large deflections of the perimeter beams may lead to a catastrophic failure of the structure. This paper presents a finite element investigation into the effects of vertical support along slab panel boundaries on the slab behaviour in fire. It examines the development of the membrane mechanism for various degrees of edge-beam protection, and makes comparisons with predictions of the membrane action design method and various acceptance criteria.

Seismic improvement of infilled nonductile RC frames with external mesh reinforcement and plaster composite

  • Kamanli, Mehmet;Korkmaz, Hasan H.;Unal, Alptug;Balik, Fatih S.;Bahadir, Fatih;Cogurcu, Mustafa T.
    • Earthquakes and Structures
    • /
    • 제8권3호
    • /
    • pp.761-778
    • /
    • 2015
  • The objective of this paper is to report the result of an experimental program conducted on the strengthening of nonductile RC frames by using external mesh reinforcement and plaster application. The main objective was to test an alternative strengthening technique for reinforced concrete buildings, which could be applied with minimum disturbance to the occupants. Generic specimen is two floors and one bay RC frame in 1/2 scales. The basic aim of tested strengthening techniques is to upgrade strength, ductility and stiffness of the member and/or the structural system. Six specimens, two of which were reference specimens and the remaining four of which had deficient steel detailing and poor concrete quality were strengthened and tested in an experimental program under cyclic loading. The parameters of the experimental study are mesh reinforcement ratio and plaster thickness of the infilled wall. The effects of the mesh reinforced plaster application for strengthening on behavior, strength, stiffness, failure mode and ductility of the specimens were investigated. Premature and unexpected failure mode has been observed at first and second specimens failed due to inadequate plaster thickness. Also third strengthened specimen failed due to inadequate lap splice of the external mesh reinforcement. The last modified specimen behaved satisfactorily with higher ultimate load carrying capacity. Externally reinforced infill wall composites improve seismic behavior by increasing lateral strength, lateral stiffness, and energy dissipation capacity of reinforced concrete buildings, and limit both structural and nonstructural damages caused by earthquakes.

내부유공판을 사용한 각형 CFT 기둥-보 단순인장 접합부의 실험적 연구 (An Experimental Study on Simple Tension Connections for Square CFT Column to Beam Using Internal Plate with Holes)

  • 이성희;정헌모;양일승;최성모
    • 한국강구조학회 논문집
    • /
    • 제21권6호
    • /
    • pp.575-583
    • /
    • 2009
  • 최근 건물이 고층화 됨에 따라 건물의 중량감소와 시공의 효율성 확보를 위해 기존 S, RC, SRC 이외에 새로운 구조시스템이 적용되고 있으며, 그중에서도 CFT 구조는 우수한 구조성능과 시공성으로 많은 건설현장에 적용되어 왔다. CFT 구조는 접합부 구성시 보 플랜지 하중을 기둥과 반대편 보에 원활히 전달하기 위한 다이아그램이 필요하며 특히 기둥 좌우에 춤이 다른 보가 접합될 때 보의 하부 플랜지 하중전달을 위한 다이아프램 구성과 콘크리트 충전성 확보에 어려움이 있었다. 본 연구에서는 하부 보 플랜지 하중을 기둥에 원활히 전달하기 위해 CFT 기둥 내부에 유공판을 세로로 접합하는 형식의 접합상세를 제안하였다. 이 접합형식은 CFT 기둥 내부에 콘크리트가 충전될 때 콘크리트가 내부 유공판의 구멍을 관통하여 채워짐으로써 보 플랜지 하중전달에 콘크리트의 앵커효과를 이용하는 방법이며 유공판이 수직으로 설치됨으로써 콘크리트 충전성도 향상시킬 수 있다. 제안된 접합부의 구조거동분석을 위해서 내부유공판의 설치방향, 콘크리트의 충전 유/무, 내부유공판의 두께, 전단구멍의 개수등을 변수로하여 5개의 실험체를 제작하고 실험체의 실험적연구를 진행하였다.

Shear strength formula of CFST column-beam pinned connections

  • Lee, Seong-Hui;Kim, Young-Ho;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제13권5호
    • /
    • pp.409-421
    • /
    • 2012
  • Recently, as the height of building is getting higher, the applications of CFST column for high-rise buildings have been increased. In structural system of high-rise building, The RC core and exterior concrete-filled tubular (CFST) column-beam pinned connection is one of the structural systems that support lateral load. If this structural system is used, due to the minimal CFST column thickness compared to that of the CFST column width, the local moment occurred by the eccentric distance between the column flange surface from shear bolts joints degrades the shear strength of the CFST column-beam pinned connections. This study performed a finite element analysis to investigate the shear strength under eccentric moment of the CFST column-beam pinned connections. The column's width and thickness were used as variables for the analysis. To guarantee the reliability of the finite element analysis, an actual-size specimens were fabricated and tested. The yield line theory was used to formulate an shear strength formula for the CFT column-beam pinned connection. the shear strength formula was suggested through comparison on the results of FEM analysis, test and yield lime theory, the shear strength formula was suggested.

The effect of three-variable viscoelastic foundation on the wave propagation in functionally graded sandwich plates via a simple quasi-3D HSDT

  • Tahir, Saeed I.;Tounsi, Abdelouahed;Chikh, Abdelbaki;Al-Osta, Mohammed A.;Al-Dulaijan, Salah U.;Al-Zahrani, Mesfer M.
    • Steel and Composite Structures
    • /
    • 제42권4호
    • /
    • pp.501-511
    • /
    • 2022
  • Earthquake Resistant Design Philosophy seeks (a) no damage, (b) no significant structural damage, and (c) significant structural damage but no collapse of normal buildings, under minor, moderate and severe levels of earthquake shaking, respectively. A procedure is proposed for seismic design of low-rise reinforced concrete special moment frame buildings, which is consistent with this philosophy; buildings are designed to be ductile through appropriate sizing and reinforcement detailing, such that they resist severe level of earthquake shaking without collapse. Nonlinear analyses of study buildings are used to determine quantitatively (a) ranges of design parameters required to assure the required deformability in normal buildings to resist the severe level of earthquake shaking, (b) four specific limit states that represent the start of different structural damage states, and (c) levels of minor and moderate earthquake shakings stated in the philosophy along with an extreme level of earthquake shaking associated with the structural damage state of no collapse. The four limits of structural damage states and the three levels of earthquake shaking identified are shown to be consistent with the performance-based design guidelines available in literature. Finally, nonlinear analyses results are used to confirm the efficacy of the proposed procedure.

불연속웨브가 도입된 프리스트레스트 합성연결보에 대한 내진성능 평가 (Evaluation of Seismic Performances on Prestressed Composite Coupling Beams with Discontinuous Webs)

  • 오재열;이득행;최승호;김강수;이성태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권1호
    • /
    • pp.133-142
    • /
    • 2013
  • 연결보를 가진 전단벽 시스템은 벽체의 개별 강성을 합산한 것보다 훨씬 큰 강성을 확보할 수 있기 때문에 효율적인 횡력저항시스템으로서 40층 이하의 중 고층 건물에 널리 적용되고 있다. 일반적으로 사용되는 철근콘크리트 연결보는 철근배근이 복잡해 시공성이 저하되고, 철골연결보의 경우에는 과도한 스티프너의 사용으로 인해 경제성이 저하된다는 단점을 가지고 있다. 따라서, 이 연구에서는 철근콘크리트와 철골부재를 합성하여 시공성 및 경제성을 개선하고 단면크기를 줄일 수 있는 불연속웨브가 적용된 프리스트레스트 합성연결보를 개발하였다. 개발한 프리스트레스트 합성 연결보의 구조적인 성능을 검증하기 위해서 전단철근비를 주요 변수로 두 개의 실험체를 제작하여 반복하중실험을 수행하였으며, 실험결과는 제안된 연결보의 내진성능을 검증하였다.

U형 프리캐스트 콘크리트 벽패널로 채운 기존 철근 콘크리트 보-기둥 구조물의 휨 거동 분석 (Analysis on the Flexural Behavior of Existing Reinforced Concrete Beam-Column Structures Infilled with U-Type Precast Wall Panel)

  • 손국원;유승룡;임철우;주호성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권5호
    • /
    • pp.56-66
    • /
    • 2015
  • 이 연구의 목표는 학교 건물과 같은 저층 보-기둥 철근콘크리트 구조 건물에서 프리캐스트 벽패널을 사용한 새로운 내진보강 방법을 개발하는 것이다. 1개의 무 보강 보-기둥 실험체와 U형 PC 벽패널로 보강한 2개의 보강 보-기둥 실험체에 대한 정적 이력 하중실험을 진행하였다. 앵커접합 PR1-UA 실험체와 철판접합 PR1-UP 실험체는 무 보강 실험체보다 평균 2.8배(평균 591.8 kN)의 강도 증가를 보여 주었다. 최대 변위비도 1.4%에서 2.7%사이 값을 보여주었다. RC 골조 우측 상단에서 좌측방향으로 가력 할 때 우측에 있는 RC 기둥과 보강 PC 패널의 수직 요소는 완전 합성상태로 가정하였고, 좌측에 있는 RC 기둥과 PC 패널은 완전 비 합성 거동하는 것으로 가정하여 해석한 결과 전체적인 휨 거동은 실험 결과와 대체적으로 부합하는 것으로 판단되었다.

FRP로 보강된 콘크리트 부재의 압축응력-변형률 예측을 위한 뉴로퍼지모델의 적용 (Prediction of Ultimate Strength and Strain of Concrete Columns Retrofitted by FRP Using Adaptive Neuro-Fuzzy Inference System)

  • 박태원;나웅진;권성준
    • 콘크리트학회논문집
    • /
    • 제22권1호
    • /
    • pp.19-27
    • /
    • 2010
  • 건축물이나 교량과 같은 RC 구조물의 경우, 다양한 유해 환경하의 재료적인 열화나 구조적 문제로 콘크리트의 노후화 및 손상이 발생하게 된다. 콘크리트의 균열이나 철근의 부식, 구조 단면의 변형 등은 구조적 안전성 저하 및 구조물 거동 특성 변화의 주요 원인이 되기도 한다. 따라서 이와 같은 콘크리트 구조물의 보수 보강을 위하여, 효과적이고 적용이 간편한 공법의 개발이 콘크리트 분야의 중요한 연구 과제 중의 하나로 인식되어 왔다. 다양한 보수 보강 기법들이 과거 수십 년 동안 개발되어 적용되고 있으며, 이중에서도 최근 FRP 복합 재료를 구조물의 외부에 접착시키는 방법을 통한 보강 방식이 많이 사용되고 있다. 이 연구는 인공 지능(AI)의 일종인 뉴로퍼지모델(ANFIS) 을 이용하여, FRP로 보강된 원주형 콘크리트 부재의 보강 효과를 분석하는데 그 목적이 있다. ANFIS 모델을 이 연구에 적용하기 위하여, 기존 연구 자료 및 실험에서 얻은 결과를 통해 학습 데이터와 시험 데이터 세트를 구축하였다. 이 연구에서 구축된 ANFIS 모델은 기존 피보강 콘크리트의 압축강도, 보강재의 두께, 보강재의 보강 겹수, 보강재의 탄성계수, 보강재의 파단강도 및 보강재와 피보강재의 체적비, 피보강재의 부재크기를 입력 자료의 파라미터로 사용하여, 압축강도, 변형률, 2차탄성계수 등을 예측하는 방식으로 활용될 수 있으며, ANFIS 모델을 통하여 예측된 결과를 기존 연구자들이 제안한 FRP 보강 콘크리트 부재의 구성 방정식과 비교할 때 더 높은 정확도로 예측이 가능함을 확인할 수 있다.

합성트러스 보의 내화성능에 관한 실험적 연구 (An Experimental Study on the Fire Resistance of Composite Truss Beam)

  • 박원섭;김흥열;김형준
    • 한국화재소방학회논문지
    • /
    • 제23권6호
    • /
    • pp.135-141
    • /
    • 2009
  • 합성트러스는 북미에서 고층건물 및 장지간 건축 구조물에 널리 사용되어지고 있는 구조물의 형태로 비슷한 다른 건축 구조에 비하여 빠른 시공 속도와 낮은 경간비와 자중비의 장점이 있다. 12~18m 경간 범위에서는 가장 경쟁력이 있는 구조물의 형태로 알려져 있다. WTC 붕괴 사고 이후, 화재 시 구조물의 내화거동에 관한 연구의 필요성이 부각됨에 따라 화재와 관계된 여러 분야에서의 연구가 세계적으로 활발하게 진행 중에 있다. 본 연구에서 수행된 실험에서 화염에 직접 노출된 트러스 강재 부재의 경우 짧은 가열시간에도 불구하고, $700^{\circ}C$ 이내의 온도 분포를 보이며 콘크리트 내부에 위치한 센서의 경우는 $200^{\circ}C$ 이내의 온도 분포를 보였다. 20mm 사재의 경우, 구조물의 처짐은 3분을 전후하여 빠른 처짐 분포를 보이며 파괴되었으나, 25mm, 35mm, 45mm 사재의 경우, 구조물은 파괴되지 않았으나 모두 15분 이내에 L/20의 처짐 기준에 도달하였다.