DOI QR코드

DOI QR Code

Evaluation of Seismic Performances on Prestressed Composite Coupling Beams with Discontinuous Webs

불연속웨브가 도입된 프리스트레스트 합성연결보에 대한 내진성능 평가

  • 오재열 (서울시립대학교 건축공학과) ;
  • 이득행 (서울시립대학교 건축공학과) ;
  • 최승호 (서울시립대학교 건축공학과) ;
  • 김강수 (서울시립대학교 건축학부) ;
  • 이성태 (인하공업전문대학 토목환경과)
  • Received : 2012.10.19
  • Accepted : 2012.12.13
  • Published : 2013.01.30

Abstract

The shear wall system with coupling beams has been known as an effective means for moderate and high rise buildings up to 40 stories, because this structural system can provide the enhanced lateral stiffness compared to individual shear walls. Typical reinforced concrete coupling beams have difficulties in construction due to complicated reinforcing work on site, and steel coupling beams also have disadvantages in economical point of view because of a large number of stiffeners required for its stability under lateral loading. To overcome these disadvantages in existing coupling beam systems, this study developed the prestressed composite coupling beam with discontinuous webs, which have improved constructability, economic feasibility, and reduced sectional size. The reversed cyclic loading test on two prestressed composite coupling beams with discontinuous webs having different shear reinforcement ratios have been conducted to investigate their structural performances, and test results showed that the proposed composite coupling beams had good seismic performances.

연결보를 가진 전단벽 시스템은 벽체의 개별 강성을 합산한 것보다 훨씬 큰 강성을 확보할 수 있기 때문에 효율적인 횡력저항시스템으로서 40층 이하의 중 고층 건물에 널리 적용되고 있다. 일반적으로 사용되는 철근콘크리트 연결보는 철근배근이 복잡해 시공성이 저하되고, 철골연결보의 경우에는 과도한 스티프너의 사용으로 인해 경제성이 저하된다는 단점을 가지고 있다. 따라서, 이 연구에서는 철근콘크리트와 철골부재를 합성하여 시공성 및 경제성을 개선하고 단면크기를 줄일 수 있는 불연속웨브가 적용된 프리스트레스트 합성연결보를 개발하였다. 개발한 프리스트레스트 합성 연결보의 구조적인 성능을 검증하기 위해서 전단철근비를 주요 변수로 두 개의 실험체를 제작하여 반복하중실험을 수행하였으며, 실험결과는 제안된 연결보의 내진성능을 검증하였다.

Keywords

References

  1. ACI Innovation Task Group 1 and Collaborators, Acceptance Criteria for Moment Frames Based on Structural Testing, American Concrete Institute, Farmington Hills, 2001, p.10.
  2. British Standards Institution, structural use of steel work in building. part3 : Design in composite construction. BS 5950. BSI, 1990.
  3. Derrick D. R. and Nicolas J. R., "Design of the Tallest Reinforced Concrete Structure in California-a-58-story Residential Tower in San Francisco", ASCE, Structures Congress, 2008.
  4. Gong B. and Shahrooz B. M., "Seismic Behavior and Design of Composite Coupled Wall Systems", Cincinnati Infrastructure Institute, Cincinnati, OH., Report No. UC-CII 98/01, 1998.
  5. Gong B. Shahrooz B. M. and Gillum A. J., "Seismic Behavior and Design of Composite Coupling Beams", Composite Construction in Steel and Concrete III, ASCE, New York, 1997, pp.258-271.
  6. Gong B., Shahrooz B. M. and Gillum A. J., "Cyclic Response of Composite Coupling Beams", ACI Special Publication 174 Hybrid and Composite Structures, 1998, pp.89-112.
  7. Han, S., W., Oh, Y., H., Oh, C., H. and Lee, L., H., "Structural Performance of Shearwall with Sectional Shape in Wall-type Apartment Buildings", Journal of Korea Concrete Institute, vol. 12, No. 4, 2000, pp.3-14. (in Korean)
  8. Kent A. H., Patrick J. F., Baharam M. S. and Paul J. B., "Practical Design of Diagonally Reinforced Concrete Coupling Beams-Critical Review of ACI 318 Requirements", vol. 102, No. 6, ACI Structural Journal, 2005, pp.876-882.
  9. Kim, K. S., Lee, D. H., Choi, S. M., Choi, Y. H. and Jung, S. H., "Flexural Behavior of Prestressed Composite Beams with Corrugated Web: Part I. Development and Analysis", Composites Part B: Engineering, vol. 42, No. 6, 2011, pp.1603-1616. https://doi.org/10.1016/j.compositesb.2011.04.020
  10. Kim, K., W. and Park, M., H., "Nonlinear Analysis of Reinforced Concrete Shear Wall Using Mander's Fiber Section Analysis Method", Journal of the Korea Institute for Structural Maintenance and Inspection, vol. 9, No. 3, 2005, pp.111-119. (in Korean)
  11. Lee, S., G., Kim, S. C., Song, C., Y. and Song, S., Y., "Stability Analysis of Concrete Shear Wall System with Opening", Journal of the Korea Institute for Structural Maintenance and Inspection, vol. 9, No. 4, 2005, pp.109-118. (in Korean)
  12. Oh, J. Y., Lee, D. H. and Kim, K. S., "Accordion Effect of Prestressed Steel Beams with Corrugated Webs", Thin-Walled Structures, vol. 57, No. 1, 2012, pp.49-61. https://doi.org/10.1016/j.tws.2012.04.005
  13. Park, H., G., Kang, S., M., Cho, B., H. and Hong, S., G., "Earthquake-Resistance of Slender Wall with No Boundary Confiement", Journal of Korea Concrete Institute, vol. 12, No. 5, 2000, pp.47-57. (in Korean)
  14. Park, W. S. and Yun, H. D., "Seismic Behaviour of Steel Coupling Beams Linking Reinforced Concrete Shear Walls", Engineering Structures, vol. 27, No. 7, 2005, pp.1024-1039. https://doi.org/10.1016/j.engstruct.2005.02.013
  15. Paulay, T. and Binney, J. R., "Diagonally Reinforced Concrete Beams for Shear Walls", American Concrete Institute, SP-42. vol. 2. pp.579-598.
  16. S. Mori, T. Miyoshi, H. Katoh, "A Study on Local Stresses of Corrugated Steel Webs in PC Bridges under Prestressing", Tech Memorandum Public Works Res Inst, 4009, 2006, pp.449-458.
  17. Seo, S., Y., Kim, J., S., Choi, Y., C. and Lee, L., H., "Nonlinear Behavior Analysis of RC Shear Wall Using Truss Theory", Journal of the Korea Institute for Structural Maintenance and Inspection, vol. 9, No. 3, 2005, pp.213-220. (in Korean)
  18. Shahrooz B. M. and Gong, B., "Steel-concrete coupling beams: a critical overview of design guidelines", Structural Engineers World Wide, 1998, pp.T186-3.