• 제목/요약/키워드: steel and bridge

검색결과 1,628건 처리시간 0.033초

Improvements to the analysis of floorbeams with additional web cutouts for orthotropic plated decks with closed continuous ribs

  • De Corte, Wouter;Van Bogaert, Philippe
    • Steel and Composite Structures
    • /
    • 제7권1호
    • /
    • pp.1-18
    • /
    • 2007
  • Additional cutouts in the floorbeam webs of orthotropic plated bridge decks relieve the highly stressed lower flange of the ribs passing through these floorbeam webs from possible fatigue damage. Conversely, the floorbeam webs themselves suffer from high stress concentrations, especially along the free edges of the additional cutouts. These stresses result from a combination of direct introduction of vertical traffic loads in the weakened web and from the truss action of the floorbeam. The latter differs from a simple beam action due to the presence of the openings and corresponds more to the behaviour of a Vierendeel truss. Close assessment of the appearing stresses, highly relevant for fatigue resistance, requires the use of elaborate finite element modelling. However, a full finite element analysis merely provides the results of total stresses, leaving the researcher or designer the difficult task of finding the origin of these stress components. This paper presents a calculation method for cutout stresses based on a combination of a framework analysis and a two dimensional finite element analysis of much smaller parts of the floorbeam. This method provides more insight in the origin of the stress components, as well as it simplifies any comparison of different additional cutout geometries, independent of the floorbeam topology.

광섬유 간섭계 센서를 이용한 콘크리트 구조물의 내부 스트레인 측정 (The measurement of the internal strain of a concrete specimen using optical fiber interferometric sensors)

  • 이경진;박재희;강신원
    • 센서학회지
    • /
    • 제10권6호
    • /
    • pp.304-309
    • /
    • 2001
  • 콘크리트 구조물의 내부 변형률을 측정할 수 있는 광섬유 간섭계 센서가 개발되어졌다. 광섬유 간섭계 센서는 11 mm 길이의 광섬유 Fabry-Perot 간섭계를 2 mm 지름의 스텐레스 강관 내부에 접착제로 고정하여 만들었다. 제작된 변형률 센서들은 $100{\times}100{\times}500\;mm^3$ 크기의 콘크리트 구조물 내부에 삽입되어 외부에서 구조물에 압력을 인가했을 때 구조물 내부의 변형률을 측정하였다. 센서들의 출력은 변형률 변화에 따라 선형적으로 변화하였다. 이를 바탕으로 실제 교량에 적용하여 변형률 센서의 광출력 특성을 살펴본 결과 우수한 변형 감지 특성을 보였으며, 실제 구조물에서 원거리측정에 이용도 가능하였다.

  • PDF

건축물에너지 효율을 위한 조적조 열교 차단 브라켓의 성능 평가 연구 (A Study on Performance Evaluation of Masonry Thermal Bridge Blocking Brackets for Building Energy Efficiency)

  • 김웅회;김형규;이태규;이재현;김규용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.175-176
    • /
    • 2023
  • The masonry structure is constructed by cement mortar binding material of brick objects and uses reinforced hardware(connected hardware or wall tie) together when building. However, over time, the corrosion of reinforced steel and the deterioration of joint mortar as well as bricks cause the risk of collapse. In particular, when the externally decorated brick wall is installed on the concrete girder for each floor, the angle bracket is not constructed or corroded, the full-layer weight load is applied to the wall of 0.5B, which is an example of full-scale or collapse. As a result of the evaluation, it was confirmed that the performance was improved compared to the existing bracket, and we plan to carry out a real-life test and long-term performance review of the building using the bracket in the future.

  • PDF

구조계산서의 표준화된 문서모델 구축 방법 (A Development Method for Standardized Document Model of Structural Calculation Document)

  • 김봉근;박상일;김효진;이상호
    • 한국재난관리표준학회지
    • /
    • 제1권3호
    • /
    • pp.83-91
    • /
    • 2008
  • 최근 많은 건설정보가 전자문서로 기록되고 있다. 그러나 현재 실무에서 작성되고 있는 설계문서는 재난관리를 위한 정보의 공유나 교환에 적합하지 않다. 본 연구는 사회기반시설물의 구조계산서 정보를 체계적으로 저장 및 관리할 수 있도록 지원하기 위한 XML Schema 기반의 문서모델을 구축하는 방법을 제시하였다. 또한 구조계산서에 기술된 다양한 양식의 서술방식을 표현하기 위한 5가지의 기본 자료형을 개발하였다. 제시된 방법을 이용하여 강교량 구조계산서의 시범 문서모델을 구축하였으며, 이를 통해 제시된 방법이 구조계산서의 문서모델을 구축하는데에 효과적으로 사용가능 함을 확인할 수 있었다.

  • PDF

받침배치에 따른 곡선교의 동적응답에 관한 연구 (Dynamic Response of Curved Bridges by Support Arrangement)

  • 김상효;이용선;김태열
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.185-191
    • /
    • 2002
  • In this study a 3-dimensional analytical model is developed, which can analyses dynamic responses of curved bridges subject to moving vehicles. A 5-axle semi-trailer is modeled to simulate the actual tire forces that are redistributed by vehicle rolling effect due to the centrifugal force. The 1-span curved bridge with two steel box girders is modeled using the frame elements. The dynamic response characteristics of curved box girder bridges are examined and compared for two different support conditions. One is the case that two shoes are arranged at the outer sides of box girders with larger space between the two shoes and the other is that two shoes at the center of each box girder. In the curved bridges, the dynamic effect of moving vehicles influences the reaction force much more than other responses, such as displacement or stress, especially the upward reaction of inner-radius shoes. It is more advantageous for the reaction considering dynamic effect when shoes are arranged further at the outer sides of box girders than when shoes at the center of each box. The shoes for curved bridges with two-box girder system should be arranged to have larger distance.

  • PDF

매우 취성인 재료의 동적 파괴인성치 결정법 (Determination of Dynamic Fracture Toughnesses for very Brittle Materials)

  • 이억섭;전현선
    • 한국정밀공학회지
    • /
    • 제14권12호
    • /
    • pp.160-165
    • /
    • 1997
  • The instrumented Charpy impact test is generally used to evaluate the dynamic fracture toughnesses for varying engineering materials. However, the test is known to be difficult to evaluate the dynamic fracturetoughnesses for very brittle materials because of the small crack initiation load which may be engulfed by the inertia load of the instrumented tup. To evaluate the dynamic fracture toughnesses of very brittle materials, such as chalk or plaster,it is thus, necessary to develop a load sensitive instrumented tup. In this study, a polymer tup, which has very small Young's modulus comparing to one of the conventional steel tup, is used for the instrumented Charpy impact test, and a proper testing method to evaluate the dynamic fracture behavior of very brittle materials is developed. The results show that the developed method can measure rapidly changing loads from the moment of contact between the tup and the specimen to dynamic crack initiation of the very brittle materials.

  • PDF

절취부를 갖는 세로보의 피로거동과 보수·보강에 관한 연구(I) -정적거동 및 피로거동의 실험적 고찰- (Study on Fatigue Behavior and Rehabilitation of Stringer with Coped Section(I) -Experimental Study on Static and Fatigue Behavior-)

  • 황윤국;장동일
    • 한국강구조학회 논문집
    • /
    • 제9권3호통권32호
    • /
    • pp.363-375
    • /
    • 1997
  • 절취된 세로보를 갖는 강철도교량의 바닥판에서의 피로거동 및 손상시 보수 보강의 효과를 연구하기 위해 8개 대형시험체에 대한 모형시험을 수행하였다. 실교량을 대상으로 실동응력을 측정하여 기본 응력범위 빈도히스토그램을 작성하고 이에 의한 변동응력의 등가응력범위를 산출하였다. 이 등가응력범위를 기준으로 피로시험의 응력변동범위의 크기를 조정하면서 정적 및 피로시험을 보강전과 보수 보강후로 구분하여 실시하였다. 정적시험에 의하면 재하하중의 크기가 등가실동응력 수준인 시험체의 경우에서 이미 허용응력과 비슷한 응력을 나타내므로서 피로균열의 발생조건을 충족하고 있었다. 손상된 시험체에 대해 다양한 보수 및 보강을 실시하여, 각각의 결과를 비교검토하였다. 그 결과 보수효과는 stop hole을 천공하고 고장력볼트를 체결한 경우에 피로균열성장의 지체효과가 뚜렷하게 나타났다. 한편 보강효과는 휨의 지배를 받는 세로보의 경우 인장측 플랜지의 보강이 효과적이며, 복부의 보강은 보강방법으로 적절하지 않음을 알 수 있었다. 또한 직각절취된 세로보의 피로설계등급은 우리나라 시방서 피로설계규정의 E등급에 해당한다는 것을 확인할 수 있었다.

  • PDF

섬유 종류에 따른 시멘트복합체의 고속 비상체 충격에 대한 배면파괴저감 및 균열특성 평가 (Evaluation on Rear Fracture Reduction and Crack Properties of Cement Composites with High-Velocity Projectile Impact by Fiber Types)

  • 한상휴;김규용;김홍섭;김정현;남정수
    • 콘크리트학회논문집
    • /
    • 제27권2호
    • /
    • pp.157-167
    • /
    • 2015
  • 고속 비상체에 의한 충격을 받는 시멘트 복합체는 표면관입, 배면박리 및 관통 등 국부적인 파괴거동을 보이며, 섬유혼입에 의한 휨인성의 향상으로 인해 배면파괴를 억제할 수 있다. 이에 섬유보강 시멘트 복합체의 내충격 성능에 관한 연구가 진행되고 있으며, 다양한 종류의 섬유보강재가 개발되고 있다. 섬유보강재의 종류에 따라 섬유와 매트릭스의 부착성능, 비표면적, 혼입개체수 등이 다르기 때문에 섬유보강 시멘트 복합체의 역학특성 및 고속 충격에 의한 내충격 성능의 향상에 미치는 효과에 대하여 검토할 필요가 있다. 본 연구에서는 성상 및 물성이 다른 강섬유(Steel fiber), 폴리아미드(Polyamide), 나일론(Nylon) 및 폴리에틸렌(Polyethylene)섬유를 혼입하여 섬유 종류에 따른 휨인성의 향상과 고속 비상체 충돌에 대한 파괴저감효과에 대하여 평가하였다. 그 결과, 혼입섬유의 가교작용에 의한 응력의 재분배 및 균열발생의 억제로 인해 휨인성이 향상되었으며, 고속충격에 의한 배면파괴를 억제할 수 있었다. 또한, 동일 충격에너지에서의 배면파괴한계두께를 감소시킬 수 있어 방호시설물에 적용할 경우 부재두께의 저감이 가능할 것으로 판단된다. 한편, 강섬유보강 시멘트복합체의 경우 배면박리가 발생하였으나, 섬유와 매트릭스의 부착에 의한 일부 파편의 박리가 억제되었으며, 합성섬유보강 시멘트복합체는 섬유의 혼입개체수가 많아, 고속충격에 의한 충격파의 상쇄작용 및 에너지 분산에 의한 미세균열이 발생해 배면파괴억제효과가 큰 것으로 판단된다.

화상처리 기법과 전기화학적 임피던스 분광법을 이용한 강교 도장용 에폭시 하도 도료의 열화 평가 (Evaluation of Deterioration of Epoxy Primer for Steel Bridge Coating using Image Processing and Electrochemical Impedance Spectroscopy)

  • 이찬영;이상훈;박진환
    • Corrosion Science and Technology
    • /
    • 제8권2호
    • /
    • pp.53-61
    • /
    • 2009
  • 본 연구에서는 강교 도장재료로 사용될 수 있는 에폭시 하도 도료를 도포한 시험편을 촉진시험을 통해 열화시킨 후 도막의 외관 평가 및 EIS에 의한 평가를 실시하고, 그 2가지 방법에 대한 비교 분석을 실시하였다. 화상처리 기법에 의해 구한 총 열화 면적율과 열화도 평점 산정 결과를 상호 비교해 본 결과 녹이 발생한 경우가 그렇지 않은 경우보다 열화도 평점이 높게 나타났다. 이는 강교 도장의 열화도 평가 기준에서 단위 열화 면적율당 부여하는 열화도 평점이 박리의 경우보다 녹의 경우가 더 크기 때문이다. 열화 면적율과 EIS 측정 데이터를 비교해 본 결과 녹의 면적율 약 0.1% 이상, 블리스터링의 면적율 약 3% 이상만 되어도 도막의 임피던스는 약 $10^4{\Omega}{\cdot}cm^2$ 혹은 그 이하로 크게 저하되었다. 2개의 시험편을 제외한 모든 시험편에 대해 전하전달저항(charge transfer resistance, $R_{ct}$)과 이중층 정전용량(double layer capacitance, $C_{dl}$) 값이 나타났으며, 이 결과로부터 이들 시험편들은 도막과 강재 계면에 수분이 축적되어 부식이 진행되고 있음을 알 수 있었다. 열화도 평점과 EIS 측정결과를 상호 비교해 본 결과 저주파수(10 mHz)에서의 임피던스 값이 $10^6{\Omega}{\cdot}cm^2$ 이하로 떨어진 경우는 모두 열화도 평점이 10점 이상으로 나타났으며, NORSOK cyclic test 과정에 의해 열화시킨 경우 열화도 평점이 높지 않음에도 불구하고 임피던스는 가장 낮게 나타났다. 이것은 도장계와 열화조건이 주 시험편과 다르기 때문인 것으로 판단되며, 열화조건이 더 가혹하거나 복합적일 경우 외관 상태에 비해 도막의 저항이 더 크게 저하될 가능성이 있다고 생각된다.

GFRP 보강근으로 보강된 바닥판의 보강비에 따른 정적 및 피로성능 평가 (Evaluation of Static and Fatigue Performances of Decks Reinforced with GFRP Rebar for Reinfocement Ratio)

  • 유영준;박영환;최지훈;김장호
    • 콘크리트학회논문집
    • /
    • 제26권4호
    • /
    • pp.491-497
    • /
    • 2014
  • 철근의 부식은 철근콘크리트 교량 바닥판의 성능 저하에 큰 요인으로 작용한다. FRP는 비부식성 재료이기 때문에 이를 활용하여 보강근을 개발하려는 노력이 이루어지고 있다. 여러 종류의 FRP 보강근이 개발되었으나 아직 활용 실적은 많지 않은 상황이다. 그 이유로는 FRP 보강 콘크리트 구조물에 대한 단/장기 검증 데이터가 부족하기 때문이다. 이 연구에서는 GFRP 보강 바닥판에 대한 피로성능을 관찰하기 위해서 길이 4000 mm, 폭이 3000 mm, 높이 240 mm인 실제 크기의 교량 바닥판을 도로교설계기준을 준용하여 제작한 후 실험을 실시하였다. 하부 보강비를 변수로 설정하였으며 DB-24 하중이 바닥판 중앙에 집중 작용하는 것으로 실험을 실시하였다. 사용하중의 3.5, 4.5, 5.0배에 해당하는 다양한 하중을 2백 만회 이상 반복 재하하여 GFRP 보강 바닥판의 피로성능을 관찰하였다. 실험 결과 거더가 횡구속된 GFRP 보강 바닥판의 최대성능은 보강근비에는 민감하지 않았고, 피로성능은 보강비보다는 적용하중의 크기에 민감하며, 바닥판이 200만회 이상 반복재하에 저항하기 위해서는 재하되는 집중하중의 크기는 최대하중의 58% 수준 이하이어야 하며, 이 연구의 실험 대상 GFRP 보강 바닥판의 피로수명은 철근 콘크리트 바닥판의 수명 예측값보다는 다소 낮은 값을 나타내었고 FRP 보강 콘크리트 바닥판의 기존 예측값보다는 높은 값을 나타내었다.