• Title/Summary/Keyword: steam injection

Search Result 106, Processing Time 0.061 seconds

Development of a special thermal-hydraulic component model for the core makeup tank

  • Kim, Min Gi;Wisudhaputra, Adnan;Lee, Jong-Hyuk;Kim, Kyungdoo;Park, Hyun-Sik;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1890-1901
    • /
    • 2022
  • We have assessed the applicability of the thermal-hydraulic system analysis code, SPACE, to a small modular reactor called SMART. For the assessment, the experimental data from a scale-down integral-test facility, SMART-ITL, were used. It was conformed that the SPACE code unrealistically calculates the safety injection flow rate through the CMT and SIT during a small-break loss-of-coolant experiment. This unrealistic behavior was due to the overprediction of interfacial heat transfer at the steam-water interface in a vertically stratified flow in the tanks. In this study, a special thermal-hydraulic component model has been developed to realistically calculate the interfacial heat transfer when a strong non-equilibrium two-phase flow is formed in the CMT or SIT. Additionally, we developed a special heat structure model, which analytically calculates the heat transfer from the hot steam to the cold tank wall. The combination of two models for the tank are called the special component model. We assessed it using the SMART-ITL passive safety injection system (PSIS) test data. The results showed that the special component model well predicts the transient behaviors of the CMT and SIT.

Numerical Analysis of NAPL Removal from Soil and Groundwater Using Steam Injection (토양 및 지하수에서의 NAPL 제거를 위한 스팀주입 수치해석)

  • Lee, Sang-Il
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.6
    • /
    • pp.667-674
    • /
    • 1998
  • Numerical models simulating the process of NAPL from contaminated soil or groundwater through steam injection can be a useful tool for designing and evaluating the cleanup strategy under various field conditions. One and two dimensional numerical analyses were conducted based on the governing equations describing the NAPL removal as a non-isothermal, multi-phase and multi component process. Relatively good agreements were obtained between the numerical results and the observations from one-dimensional laboratory experiment, except some discrepancy due to experimental difficulties. Simulation effectively identified the steam displacement process of xylene floating on the water table and TCE sinking on the aquifer bottom in a two-dimensional analysis. Overall, simulation models have a high potential in the design/appraisal of a system for field application of the technique as well as in the examination of complex processes such as vaporization which is hard to identify experimentally.

  • PDF

Development of Steam Cleaning Technique to Improve Removal Efficiency of Membrane Fouling Matter in Water Treatment Process Using Ceramic Membrane (정수처리용 세라믹 분리막의 막오염 물질의 제거 효율 향상을 위한 스팀세정 기법 개발)

  • Kang, Joon-Seok;Park, Seo Gyeong;Lee, Jeong Eun;Kang, So Yeon;Lee, Jeong Jun;Quyen, Vo Thi Kim;Kim, Han-Seung
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.99-107
    • /
    • 2018
  • This research has developed a high temperature steam cleaning technology using a ceramic membrane with durability against temperature and pressure conditions. In steam cleaning, steam of $120^{\circ}C$ is injected into the ceramic membrane to induce pyrolysis by the endothermic reaction to remove fouling from the membrane. The water quality of raw water was adjusted to turbidity 10, 25 NTU and DOC 2.5 mg/L, and the membrane was uniformly fouled by constant pressure operation at 100, 200, and 300 kPa. Physical backwashing was performed with water and air at a pressure of 500 kPa and steam at $120^{\circ}C$ was injected for 0 to 5 minutes. As the turbidity concentration and the operating pressure increased, the flux decreased by 0.7 to 14.4%. It is confirmed that 10.7 to 53.8% recovery is possible than physical cleaning at the injection of steam for 3 minutes, so it is considered that the steam cleaning of the ceramic membrane is effective. Compared with CEB after NaOCl (300 mg/L) filtration at 25 NTU and 300 kPa of turbidity, the steam cleaning result for 3 minutes was similar to 46.7% of CEB for 3 hours. It has been confirmed that steam cleaning is suitable for a ceramic membrane having excellent heat resistance against high temperature. It was considered to have better cleaning efficiency as compared with general physical backwashing.

A Study for Improving Spray Uniformity of the SECFR System for Vehicle Applications (SECFR 시스템의 차량적용을 위한 분무균일도향상에 관한 연구)

  • Shon, J.W.;Woo, S.C.;Kim, S.G.;Lee, K.H.
    • Journal of ILASS-Korea
    • /
    • v.20 no.2
    • /
    • pp.95-100
    • /
    • 2015
  • Lower recirculated gas temperature at EGR system reduces NOx and PM emissions. However, EGR Cooler can be polluted by PM generated from recirculated EGR gas, and it reduces cooling efficiency and the amount of EGR gas simultaneously. The SECFR(Steam EGR Cooler Fouling Remover) system which uses the evaporated washer fluid steam caused by high temperature of EGR gas was manufactured for removing fouling generated on the cooler surface. Since an injection pressure of wind shield washer fluid in the vehicle is approximately 0.5 bar, it is not enough to atomize the injected washer fluid. Thus, it is necessary to apply a method to atomize the washer fluid. In this study, the impinging plate was used to promote the atomization of spray washer fluid for the purpose of apply SECFR system to vehicles and measured the DAR(Droplet Area Ratio) and DUI(Droplet Uniformity Index) through the spray visualization.

Experimental study on hydrogen behavior and possible risk with different injection conditions in local compartment

  • Liu, Hanchen;Tong, Lili;Cao, Xuewu
    • Nuclear Engineering and Technology
    • /
    • v.52 no.8
    • /
    • pp.1650-1660
    • /
    • 2020
  • Comparing with the large containment, the gas can not flow freely within the local compartment due to the small volume of the compartment in case of serious accident, which affects the hydrogen flow distribution, and it will determines the location where high concentration occurs in compartment. In this paper, hydrogen distribution and possible hydrogen risk in the vessel under the different conditions are investigated. The results show that when the initial gas momentum is increased, the ability of gas enters into the upper region of the vessel will be strengthened, and the hydrogen volume fraction in the upper region of the vessel is higher. Comparing with horizontal source direction, when source direction is vertically towards upper space, hydrogen is more likely to accumulate in the upper region of the vessel. With the increasing of steam mass flow, the dilution effect of steam on the hydrogen volume fraction will be strengthened, while the pressure in the vessel is also increased. When steam flow is decreased, the hydrogen explosion risk is higher in the vessel. The experiment data can provide technical support for the validation of the CFD software and the mitigation of hydrogen risk in the containment compartment.

Numerical simulation of turbulent air-flow in a closed engine room with heat source in a ship (열원이 있는 밀폐된 선박 기관실에서의 난류기류에 관한 수치적 연구)

  • 박찬수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.100-107
    • /
    • 1998
  • Ventilation of the marine engine room is very important for the health of the workers as well as the nomal operation of machines. To find proper ventilation conditions of this engine room, numerical simulation with standard k-.epsilon. model was carried out. In the present study, the marine engine room is considered as a closed space with a heat source and forced ventilation ducts. The injection angle of air supply is found to be important. Injection with downword angle depresses recirculation flow, causing a strong steam in the wider space of the room. Ventilation and removal of the released heat are promoted with this pattern. There is a possibility of local extreme heating at the upper surface of engine when supply and exhaust ports of air are in bilateral symmetry. The effect of the increase of exhaust port area on ventilation decreases as the number of supply port increases.

  • PDF

Comparison of Ammonia Mass Flow Rate between Two Ammonia Injection Positions in DeNOx system of a Horizontal HRSG (수평형 HRSG의 탈질설비에서 암모니아 분사위치 변동에 따른 암모니아 유량비교)

  • Park, Jae-Hyun;Yoo, Hoseon
    • Plant Journal
    • /
    • v.14 no.4
    • /
    • pp.48-54
    • /
    • 2018
  • As the emission limits for NOx in power generation facilities were strengthened, HRSGs installed in the 1990s became necessary to install additional DeNOx system. However, since there is no space in the HRSG for installing the entire the catalyst and ammonia injection grid, as an alternative, the catalyst was installed inside of the HRSG and the ammonia injection device was installed in the exhaust duct of the gas turbine. Experiments were conducted in horizontal HRSG of Incheon combined cycle power plant. Experimental results show that the ammonia injection method in the gas turbine exhaust duct is 1.2 times higher than the HRSG internal ammonia injection method. However when operating a HRSG for 30 years as its life span, ammonia injection method in the gas turbine exhaust duct is more economical than the cost of new HRSG construction.

  • PDF

An Investigation of Fluid Mixing with Direct Vessel Injection (직접용기주입에 따른 유체혼합에 관한 연구)

  • Cha, Jong-Hee;Jun, Hyung-Gil
    • Nuclear Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.63-77
    • /
    • 1994
  • The objective of this work is to investigate fluid mixing phenomena related to pressurized thermal shock(PTS) in a pressurized water reactor(PWR) vessel downcomer during transient cooldown with direct vessel injection(DVI) using test models. The test model designs were based on ABB Combustion Engineering(C-E) System 80+ reactor geometry. A cold leg small break loss-of-coolant accident(LOCA) md a main steam line teak were selected as the potential PTS events for the C-E System 80+. This work consist of two parts. The first part provides the visualization tests of the fluid mixing between DVI fluid and existing coolant in the downcomer region, and the second part is to compare the results of thermal mixing tests with DVI in the other test model. Row visualization tests with DVI have clarified the physical interaction between DVI fluid and primary coolant during transient cooldown. A significant temperature drop was observed in the downcomer during the tests of a small break LOCA Measured transient temperature profiles agree well with the predictions by the REMIX code for a small break LOCA and with the calculations by the COMMIX-1B code for a steam line break event.

  • PDF

Evaluation of Direct Vessel Injection Design With Pressurized Thermal Shock Analysis (가압 열충격해석에 의한 직접용기주입 설계의 평가)

  • Cha, Jong-Hee;Jun, Hyung-Gil
    • Nuclear Engineering and Technology
    • /
    • v.24 no.1
    • /
    • pp.86-97
    • /
    • 1992
  • The purpose of this paper is to evaluate the direct vessel injection design from a pressurized thermal shock(PTS) viewpoint for the Combustion Engineering System 80+ A break of the main steam line from zero power and a 0.05 ft$^2$small break loss-of-coolant accident (LOCA) from full power were selected as the potential PTS events. In order to investigate the stratification effects in the reactor downcomer region, the fluid mixing analysis was performed using the COMMIX-IB code for steam line break and using the REMIX code for 0.05 ft$^2$small break LOCA. The stress distributions within the reactor vessel walls experiencing the pressure and the temperature transients were calculated using the OCA-P code for both events. The results of the analysis showed that a small break LOCA without decay heat presented the greatest challenge to the vessel, however, there is no crack initiation through end-of-life of the vessel with consideration of decay heat.

  • PDF