• 제목/요약/키워드: steam flow

검색결과 744건 처리시간 0.027초

500MW급 초임계압 관류형 보일러 온도제어에 대한 기술 (Temperature Control Technology for Once Through Boiler)

  • 이광훈;이주현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 B
    • /
    • pp.719-721
    • /
    • 1998
  • In this paper, we reviewed the steam temperature control in an once through boiler. The steam temperature control is very difficult. Generally, steam temperature of an once through boiler is not only controlled by boiler spray water flow, but also influenced by feed water flow and fuel flow. An advanced control strategy has been developed by experienced engineer. Specifically, We reviewed temperature control strategy for Taian power plant in this paper. This control strategy is represented by state control observer. This state control observer algorithm for temperature control has been used since the late 1980's. This paper describes control strategy employed and observed benefits from advanced steam temperature control.

  • PDF

증기터빈 강제냉각 장치의 설계 및 적용 (Design and Application of Forced Cooling System in Steam Turbine)

  • 김효진;류승우;강용호
    • 한국정밀공학회지
    • /
    • 제15권9호
    • /
    • pp.25-32
    • /
    • 1998
  • The forced cooling system is designed to shorten the overhaul time of steam turbine, which is important in view of economic concern of utility companies, Forced cooling of the hot turbine is achieved by suction of air flow into the turbine after the turbine shuts down. The heat transfer process by suction of air flow can cause thermal stress due to the thermal gradients. In this paper, the analysis of heat transfer is performed to calculate the air flow rate. Based on the prediction of cyclic fatigue damage and the experience, the cooling equipment is designed for shortening the cooling time of steam turbine.

  • PDF

발전용 보일러 주증기 튜브 과열방지용 오리피스 설계기법 (The design method of overheat protection orifice for power plant boiler super heated tube)

  • 김범신;유성연;하정수;김의현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.373-378
    • /
    • 2003
  • It is important that overheat protection of super heated tube in boiler operation and maintenance. The overheat of super heat tube can make damage and rupture of tube material, which causes accidental shutdown of boiler. The super heated tube overheat is almost due to the lack of uniformity of gas temperature distribution. There are two ways to protect overheat of super heated tube. The one is to control hot gas operation pattern which is temperature or flow distribution. the other is to control super heated steam flow distribution. The former is difficult than the later, because of control device design. In this paper steam flow control method which uses orifices is proposed to protect overheat of super heat tube.

  • PDF

Interfacial Condensation Heat Transfer for Countercurrent Steam-Water Stratified Flow in a Circular Pipe

  • Chu, In-Cheol;Chung, Moon-Ki;Yu, Seon-Oh;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제32권2호
    • /
    • pp.142-156
    • /
    • 2000
  • An experimental study of steam condensation on a subcooled thick water layer (0.018 ~0.032 m) in a countercurrent stratified flow has been performed using a nearly horizontal circular pipe. A total of 103 average interfacial condensation heat transfer coefficients were obtained and parametric effects of steam and water flow rates and the degree of subcooling on condensation heat transfer were examined. The measured local temperature and velocity distributions in the thick water layer revealed that there was a thermal stratification due to the lack of full turbulent thermal mixing in the lower region of the water layer Two empirical Nusselt number correlations, one in terms of average steam and water Reynolds numbers, and the water Prandtl number, and the other in terms of the Jakob number in place of the Prandtl number, which agree with most of the data within $\pm$ 25%, were developed based on the bulk flow properties. Comparisons of the present data with existing correlations showed that the present data were significantly lower than the values predicted by existing correlations.

  • PDF

제 2종 LiBr-H2O 흡수식 히트펌프의 운전 변수에 따른 성능 특성 수치 해석 (Effects of Operation Conditions on the Performance of Type II LiBr-H2O Absorption Heat Pump)

  • 윤준성;권오경;차동안;배경진;김인관;김민수;박찬우
    • 설비공학논문집
    • /
    • 제29권1호
    • /
    • pp.7-14
    • /
    • 2017
  • This study carried out a numerical analysis of the effects of hot waste water supply on the performance of a Type II absorption heat pump. There are two types of hot waste water supply, regular series flow and reverse series flow. Also it investigated the interaction between each type of flow and heat exchange solutions. As the effectiveness of heat exchange solutions increase, the steam generation and (COP) increase as well. If the effectiveness of a heat exchange solution is lower than 0.566, the steam generation rate of the reverse flow is lower than that of the regular series flow. A high effectiveness of heat exchange solution is therefore required to make a larger amount of steam in reverse series flow than with ordinary series flow. The COP difference between the two types of flow decreases with the increasing effectiveness of the heat exchange solution. Thus, a reverse flow type absorption heat pump can match the high steam generation rate and COP of the ordinary flow type when a highly effective heat exchange solution is applied.

CE형 증기발생기 전열관의 행열 변화에 따른 유체유발진동 특성 (Characteristics of Flow-induced Vibration for CE Type Steam Generator Tube with Various Column and Row Number)

  • 유기완;조봉호;박치용;박수기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.927-932
    • /
    • 2002
  • The stability ratio and vibrational amplitude of each tube inside a steam generator have different values. We estimate the characteristics of flow-induced vibration for CE type steam generator with various column and row number of the tube. To obtain the thermal-hydraulic data and stability ratio we use the ATHOS3-MODI and PIAT-FEI/TE code respectively. It turns out that the steam generator has a bounded central zone with the distributed values of the stability ratio and the vibrational amplitude, and those values across the zone boundary become decreased.

  • PDF

CE형 증기발생기 튜브의 행열 변화에 따른 유체유발진동 특성 (Characteristics of Flow-induced Vibration for CE Type Steam Generator Tube with Various Column and Row Number)

  • Ryu, Ki-Wahn;Cho, Bong-Ho;Park, Chi-Yong;Park, Su-Ki
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.390.2-390
    • /
    • 2002
  • The stability ratio and vibrational amplitude of each tube inside a steam generator have different values. We estimate the characteristics of flow-induced vibration for CE type steam generator with various column and row number of the tube. To obtain the thermal-hydraulic data and stability ratio we use the ATHOS3 and PIAT-FEI/TE code respectively. It turns out that the steam generator has a bounded central zone which the distributed values of the stability ratio and the vibrational amplitude, and those values across the zone boundary become decreased.

  • PDF

Flow-Induced Vibration Test in the Preheater Region of n Steam Generator Tube Bundle

  • Kim, Beom-Shig;Hwang, Jong-Keun
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(4)
    • /
    • pp.312-318
    • /
    • 1996
  • Flow induced vibration experiments were done to determine the vibration magnitude of tubes in the economizer tube lane region of a steam generator. The objective of this experiment is to demonstrate that the tubes are not susceptible to harmful levels of vibration at 100% of full power flow and to quantify the remaining design margin at 120% and 140% of full power flow.

  • PDF

타워형 태양열 발전 흡수기의 열유속에 따른 수순환 특성 연구 (Water Circulation Characteristics of a Water/Steam Receiver for Solar Power Tower System at Various Heat Fluxes)

  • 서호영;김종규;강용혁;김용찬
    • 한국태양에너지학회 논문집
    • /
    • 제28권2호
    • /
    • pp.1-9
    • /
    • 2008
  • This paper describes water circulation characteristics of a water/steam receiver at various heat fluxes. The water/steam receiver for a solar tower power system is a natural circulation type. Experimental conditions of water and steam were set at a pressure of 5 bar and temperature of $151.8^{\circ}C$. The experimental device for the water/steam receiver consisted of a steam drum, upper/lower header, riser tubes, and downcomer tube. The experiments were conducted by varying heat fluxes in terms of mass flow rate in each riser tube. However, the total mass flow rate on the riser tubes was fixed at 217.4 g/s. For the uniform heat flux, while the water temperature of the steam drum and upper header were kept at steady state, the temperature of the lower header was fluctuated. For the non-uniform heat flux, while the temperature of the steam drum was kept steady state, the temperature difference increased in the right and left side of the upper header, and the temperature of the lower header was fluctuated.

수평Y자형 분지관에서 증기-물 이상류의 상분리에 관한 실험적 연구 (Experimental Studies on Phase Separation of Steam-Water Two Phase Flow in Horizontal Y-Branching Conduit)

  • 안수환
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.886-893
    • /
    • 2000
  • The Characteristics of dividing the dispersed bubble, plug, and slug steam-water flow in the horizontal junctions with horizontal branches have been experimentally investigated. The experimental investigation of the separation phenomena in a $45^{\circ}$ horizontal wye with equal pipe inner diameter of 25 mm is presented to provide a data base for the development and verification of the analytical models. The phase separation and pressure distribution in the three legs of each test section are obtained through the set of measurements made in the present work. And the dependence of phase separation on different parameters, such as inlet quality and mass flux, is discussed.