• Title/Summary/Keyword: steam

Search Result 4,627, Processing Time 0.039 seconds

Characteristics of Flow-induced Vibration for CE Type Steam Generator Tube with Various Column and Row Number (CE형 증기발생기 튜브의 행열 변화에 따른 유체유발진동 특성)

  • Ryu, Ki-Wahn;Cho, Bong-Ho;Park, Chi-Yong;Park, Su-Ki
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.390.2-390
    • /
    • 2002
  • The stability ratio and vibrational amplitude of each tube inside a steam generator have different values. We estimate the characteristics of flow-induced vibration for CE type steam generator with various column and row number of the tube. To obtain the thermal-hydraulic data and stability ratio we use the ATHOS3 and PIAT-FEI/TE code respectively. It turns out that the steam generator has a bounded central zone which the distributed values of the stability ratio and the vibrational amplitude, and those values across the zone boundary become decreased.

  • PDF

A Case Study of the STEAM Educational Outreach Program Development and their Application (융합인재교육(STEAM)의 아웃리치 프로그램 개발 및 운영 사례)

  • Seo, Won-seok;Lee, Chang-hoon
    • Journal of Engineering Education Research
    • /
    • v.18 no.6
    • /
    • pp.38-45
    • /
    • 2015
  • This study aims to conduct a case study of the Science, Technology, Engineering, Arts, and Mathematics (STEAM) outreach program development and their application. This program was operated by 184 middle and high school students at C University on October 2014. The major results of these studies were as follows: First, The theme of the outreach program consisted of four engineering areas, aerospace engineering, chemical engineering, architectural engineering, and mechatronics (robot) engineering; moreover, the materials for the students' workbook, the guidebook for teachers, and the program operation manual for staffs in a university were developed by working with four authors and ten subject matter experts. Second, the satisfaction level with the contents and activities was ranged from 4.24-4.31 out of 5 points. Third, the vitalizing activation plan was discussed for the sustainable development and operation of the STEAM outreach program.

Investigation of the coaxial cylindrical steam reformer for fuel cell applications (연료전지 적용을 위한 동축원통형 수증기 개질기의 연구)

  • Park, Joon-Geun;Lee, Shin-Ku;Bae, Joong-Myeon;Kime, Myoung-Jun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.113-116
    • /
    • 2007
  • Performance of a steam reformer can be improved by using a coaxial cylindrical reactor, because the design can enhance the heat transfer for the steam reforming reaction, which is the one of main rate-determining steps of overall reactions. The objective of this study is to investigate the coaxial cylindrical reactor numerically. Pseudo-homogeneous model and one medium approach are incorporated for the chemical reactions, and models are validated with experimental results. The catalyst of the coaxial cylindrical reactor is 67% for one of the cylindrical reactor, but fuel conversion of the coaxial cylindrical reactor is increased by 10%. Heat flux profiles are investigated by modified Nusselt number and heat flux which is transported from the product gas to the catalyst bed affecting performance of the steam reformer.

  • PDF

Circulting Fluidized Bed Combustion of Refuse Derived Fuel and Steam Production (폐기물 고형연료(RDF)의 순환유동층 연소 및 증기생산)

  • Shun, Do-Won;Bae, Dal-Hee;Cho, Sung-Ho;Lee, Seung-Yong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.613-616
    • /
    • 2007
  • A pilot scale circulating fluidized bed for refuse derived fuel is developed and constructed in order to demonstrate efficient and safe utilization of waste fuel. The capacity of the facility is 8 steam tons per hour with the steam quality of $450^{\circ}C$ and 38atm. The quantity and the quality of the produced steam is sufficient to produce 1MWe power capacity. The test operation proved the high combustion efficiency of 99% and up. The emissions of NOx, SOx in flue gas are below 100, 60ppm respectively with out any emission control. HCl emissions were above 400ppm at the combustor exit but reduced below 10ppm after scrubber.

  • PDF

A study on the microcomputer-based adaptive control system of a steam generator (적응제어알고리즘을 이용한 원자력발전소용 증기발생기 수위제어 시스템에 관한 연구)

  • 배병환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.658-663
    • /
    • 1987
  • The new controller developed here, which is the facility with only one measurement, is a new concept for the level controller of the existing nuclear steam generator. A MACS (Microcomputer-based Adaptive Control System of a Steam Generator) is quite practical and efficient, and has also simple structure and higher flexibility in the installment for actual plant. A key ingredient of this system is adaptive regulator which can calculate adaptive, optimal valve position in response to changes in the dynamics of the process and the disturbances. In spite of many difficulties in the steam generator water level control at low power, it can be concluded from the experimental and simulation results, that the MACS can provide optimal, robust steam generator level control from zero to full power. The amount of the control input effort can be reduced by adjusting the weighting factor. However, the steady state water level errors are generated. To avoid the steady errors, the different adaptive algorithm should be investigated in the future. The 3 second sampling time is acceptable for this system. However, action should be taken to shorten the sampling time for better digital control.

  • PDF

Intelligent Modeling of Nuclear Power Plant Steam Generator (원자력발전소 증기발생기의 인공지능 모델링에 관한 연구)

  • Choi, Jin-Young;Lee, Jae-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.675-678
    • /
    • 1997
  • In this research we continue the study of nuclear power plant steam generator's intelligent modeling. This model represents the input-output behavior and is a preliminary stage for intelligent control. Among many intelligent models available, we study neural network models that have been proven as universal function approximators. We select multilayer perceptrons, circular backpropagation networks, piecewise linearly trained networks and recurrent neural networks as the candidates for the steam generator's intelligent models. We take the input-output pairs from steam generator's reference model and train the neural network models. We validate trained neural network models as intelligent models of steam generator.

  • PDF

Development of New Smith Predictor Controller and a Disturbance Observer for Control of the Superheater and the Steam Pressure (보일러 과열기 및 증기 압력 제어를 위한 외란 관측기 및 새로운 스미스 예측제어기 개발)

  • Lee, Soon-Young;Shin, Hwi-Beom;Park, Soo-Yong;Jang, Eun-Syeung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1687-1688
    • /
    • 2008
  • The steam superheater and the steam pressure systems are time delay systems that have poles near the origin in the left half plane or a pure integrator. Smith predictor can't be applied to these systems any more, because of occurring the steady state error for the step disturbance. In this paper, a new Smith predictor controller for the steam superheater and the steam pressure is proposed. A disturbance observer to estimate an input disturbance and a new controller to eliminate an effect of a disturbance are proposed. The computer simulation results are shown the efficiency of the proposed system.

  • PDF

A Study on Turbine Control Algorithms for Large Steam Turbine in a Power Plant (대용량 발전소 재열재생 증기터빈 제어알고리즘에 관한 고찰)

  • Choi, In-Kyu;Jeong, Chang-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1665-1666
    • /
    • 2008
  • There are three main devices such as boiler producing steam, turbine driving generator and generator producing electricity. An electrical generator in power plant is driven and maintained its speed at rated by steam turbine which is coupled into generator directly. Therefore after the steam turbine reaches its rated speed and the generator gets into parallel operation with power grid, the electrical power can be increased by turbine controller or governor. The first governor was invented by James Watts for the steam engine to be maintained at a constant speed. The first governor by him was mechanical type with fly balls. The electrical type governor was created due to the progress of electronic devices such as operational amplifiers or integrated circuits. and Today digital electronic type of governor is being widely used in most prime movers.

  • PDF

A Study on Turbine Auxiliary Devices in a Thermal Power Plant (화력발전소 터빈 보조기기 제어 관한 고찰)

  • Jeong, Chang-Ki;Choi, In-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1667-1668
    • /
    • 2008
  • There are three main devices such as boiler producing steam, turbine driving generator and generator producing electricity. An electrical generator in power plant is driven and maintained its speed at rated by steam turbine which is coupled into generator directly. Turbine auxiliary devices such as condenser, deaerator, feed water heater, gland steam condenser, pump recirculation equipment, feed water pump, and so on should be operated well so that the steam turbine exert its maximum efficiency. There are many control loop such as hot well level and condenser recirculation, deaerator level, pegging steam pressure, feed water heater level, feed water pump recirculation. In this paper condenser level control and deaerator level control are going to be described.

  • PDF

Effect of Extrusion Processing and Steam Pelleting Diets on Pellet Durability, Water Absorption and Physical Response of Macrobrachium rosenbergii

  • Misra, Chandra Kanta;Sahu, N.P.;Jain, K.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.15 no.9
    • /
    • pp.1354-1358
    • /
    • 2002
  • Two hundred and ten post-larvae (PL) of Macrobrachium rosenbergii (14.5-14.9 mg) were equally distributed in two experimental groups and fed with either steam cooked or extruded pellet for a period of 60 days. Physical evaluation and growth promoting effect of both the pellets were assessed. Significantly higher (p<0.05) water stability, absorption and protein efficiency ratio (PER) were recorded in extruded pellet than the steam cooked pellet. Nutrient loss was minimum in the extruded pellet for which lower feed conversion ratio (FCR) (p<0.05) was recorded in this group. However, weight gain, relative growth and specific growth rate (SGR) in both the groups were not significantly different (p>0.05). Although insignificant (p>0.05) but higher amylase activity was recorded in steam pellet fed group. Survival was not affected by feeding either of the diets.