• Title/Summary/Keyword: steady state flow

Search Result 1,022, Processing Time 0.021 seconds

Long Tenn Water Quality Prediction using an Eco-hydrodynamic Model in the Asan Bay (생태-유체역학모델을 이용한 아산만 해양수질의 장기 예측)

  • Kwoun, Chul-Hui;Kang, Hoon;Cho, Kwang-Woo;Maeng, Jun-Ho;Jang, Kyu-Sang;Lee, Seung-Yong;Seo, Jeong-Bin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.2
    • /
    • pp.91-98
    • /
    • 2009
  • The long-term water-quality change of Asan Bay by the influx of polluted disposal water was predicted through a simulation with an Eco-hydrodynamic model. Eco-hydrodynamic model is composed of a multi-level hydrodynamic model to simulate the water flow and an ecosystem model to simulate water quality. The water quality simulation revealed that the COD(Chemical Oxygen Demand), dissolved inorganic nitrogen(DIN) and dissolved inorganic phosphorus(DIP) are increased at 5 stations for the subsequent 6 months after the influx of the effluent. COD, DIN and DIP showed gradual decreases in concentration during the period of one to two years after the increase of last 6 months and reached steady state for next three to ten years. Concentration levels of COD, DIN, and DIP showed the increase by the ranges of $11{\sim}67%$, $10{\sim}67%$, and $0.5{\sim}7%$, respectively, which represents that the COD and DIN are the most prevalent pollutants among substances in the effluent through the sewage treatment plant. The current water quality of Asan Bay based on the observed COD, TN and TP concentrations ranks into the class II of the Korean standards for marine water quality but the water quality would deteriorate into class III in case that the disposal water by the sewage plant is discharged into the Bay.

  • PDF

Coater Die Design and Coating Quality Evaluation in the Machine Direction of Slot Coating Through Computer Simulation (컴퓨터 해석을 통한 Slot 코팅공정에서 운전방향의 코팅품질 평가 및 다이 설계)

  • Kim, T.H.;Lee, D.Y.;Sung, D.J.;Lyu, M.Y.
    • Elastomers and Composites
    • /
    • v.48 no.4
    • /
    • pp.282-287
    • /
    • 2013
  • Slot coating has been widely spread in photo resist coating on glass for flat display monitor. High quality of coating is required as high quality of image in display is needed. Coating quality in the slot coating is divided into nozzle direction quality and machine direction quality. Nozzle direction quality is related to flow uniformity inside the die whereas machine direction quality is related to die lip design and operational conditions. In this study coating uniformity in the machine direction of slot coating has been investigated through computer simulation. Die lip angle and die lip length were considered as outside die geometry and coating speed was considered as operational condition. Coating behavior has been analyzed and coating quality has been evaluated through computer simulation. Coating thickness decreased and coating uniformity increased as coating speed increased. However, the stability of meniscus formation was reduced and subsequently coating stability was reduced as coating speed increased. Coating thickness deviation decreased as die lip angle increased in down stream die. Coating thickness decreased and time to reaching steady state increased as increased die lip length in down stream die.

Performance Evaluation of FDS for Predicting the Unsteady Fire Characteristics in a Semi-Closed ISO 9705 Room (반밀폐된 ISO 9705 화재실에서 비정상 화재특성 예측을 위한 FDS의 성능평가)

  • Mun, Sun-Yeo;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.21-28
    • /
    • 2012
  • The objective of this study is to evaluate the prediction accuracy of FDS(Fire Dynamic Simulator) for the thermal and chemical characteristics of under-ventilated fire with unsteady fire growth in a semi-closed compartment. To this end, a standard doorway width of the full-scale ISO 9705 room was modified to 0.1 m and the flow rate of heptane fuel was increased linearly with time (until maximum 2.0 MW based on ideal heat release rate) using a spray nozzle located at the center of enclosure. To verify the capability of FDS, the predicted results were compared with a previous experimental data under the identical fire conditions. It was observed that with an appropriate grid system, the numerically predicted temperature and heat flux inside the compartment showed reasonable agreement with the experimental data. On the other hand, there were considerable limitations to predict accurately the unsteady behaviors of CO and $CO_2$ concentration under the condition of continuous fire growth. These results leaded to a discrepancy between the present evaluation of FDS and the previous evaluation conducted for steady-state under-ventilated fires. It was important to note that the prediction of transient CO production characteristics using FDS was approached carefully for the under-ventilated fire in a semi-closed compartment.

HPLC Analysis and Pharmacokinetics of KAL-1120, a Novel Anti-inflammation Agent, in Rats (흰쥐에서 항염증제 후보물질 KAL-1120의 HPLC 분석 및 약물동태)

  • Shin, Dae-Hwan;Lee, Jung-Yeol;Park, Seong-Hyeok;Lee, Gyeong-Bok;Han, Kun;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.2
    • /
    • pp.101-107
    • /
    • 2010
  • A rapid and sensitive reversed-phase high performance liquid chromatography (HPLC) method was developed for the determination of N-(-4-Chlorophenyl)-6-hydroxy-7-methoxy-2-chromanecarboxamide (KAL-1120), a novel anti-inflammation agent, in the rat plasma. The method was applied to analyze the compound in the biological fluids such as bile, urine and tissue homogenates. After liquid-liquid extraction, the compound was analyzed on an HPLC system with ultraviolet detection at 275 nm. HPLC was carried out using reversed-phase isocratic elution with a $C_{18}$ column, a mobile phase of a mixture of acetonitril (40 v/v%) at a flow rate of 1.0 mL/min. The chromatograms showed good resolution and sensitivity and no interference of plasma. The calibration curve for the drug in plasma was linear over the concentration range of 0.05-50 ${\mu}g$/mL. The intra- and inter-day assay accuracies of this method ranged from 0.06% to 9.33% of normal values and the precision did not exceed 6.28% of relative standard deviation. The plasma concentration of KAL-1120 decreased to below the quantifiable limit at 1.5 hr after the i.v. bolus administration of 2-10 mg/kg to rats ($t_{1/2,({\alpha})}$ and $t_{1/2,({\beta})$ of 2.15 and 26.7 min at a dose of 2 mg/kg, 3.91 and 33.0 min at a dose of 10 mg/kg, respectively). The steady-state volume of distribution ($V_{dss}$) and the total body clearance ($CL_t$) were not significantly altered in rats given doses from 2 to 10 mg/kg. Of the various tissues tested, KAL-1120 was mainly distributed in the lung and heart after i.v. bolus administration. KAL-1120 was detected in the bile by 30 min after its i.v. bolus administration. However, the concentration in the urine after i.v. bolus administration became too low to measure, suggesting that KAL-1120 is mostly excreted in the bile. In conclusion, this analytical method was suitable for the preclinical pharmacokinetic studies of KAL-1120 in rats.

Effects of Ventilation Condition on the Fire Characteristics in Compartment Fires (Part I: Performance Estimation of FDS) (구획화재에서 환기조건의 변화가 화재특성에 미치는 영향(Part I: FDS의 성능평가))

  • Hwang, Cheol-Hong;Park, Chung-Hwa;Ko, Gwon-Hyun;Lock, Andrew
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.131-138
    • /
    • 2010
  • Experimental and numerical studies were conducted to investigate the thermal and chemical characteristics of heptane fires in a full-scale ISO 9705 room. Representative fire conditions were considered for over-ventilated fire (OVF) and under-ventilated fire (UVF). Fuel flow rate and doorway width were changed to create OVF and UVF conditions. Detailed comparisons of temperature and species concentrations between experimental and numerical data were presented in order to validate the predictive performance of FDS (Fire Dynamic Simulator). The OVF and UVF were explicitly characterized with distributions of temperature and product formation measured in the upper layer, as well as combustion efficiency and global equivalence ratio. It was shown that the numerical results provided a quantitatively realistic prediction of the experimental results observed in the OVF conditions. For the UVF, the numerically predicted temperature showed reasonable agreement with the measured temperature. The predicted steady-state volume fractions of $O_2$, $CO_2$, CO and THC also agreed quantitatively with the experimental data. Although there were some limitations to predict accurately the transient behavior in terms of CO production/consumption in the UVF condition, it was concluded that the current FDS was very useful tool to predict the fire characteristics inside the compartment for the OVF and UVF.

Economic Design of Activated Sludge System at the Optimum Sludge Concentration (슬러지 농도 최적화에 따른 합리적인 활성슬러지공정 설계방안 연구)

  • Lee, Byung Joon;Choi, Yun Young
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.5
    • /
    • pp.483-490
    • /
    • 2014
  • The design procedures for a biological reactor and a secondary settling tank (SST) of an activated sludge system are based on the steady state design method (Ekama et al., 1986; WRC, 1984) and the 1-D flux theory design method (Ekama et al., 1997), respectively. This study combined both of the design procedures, to determine the optimum sludge concentration in the reactor and the best design with the lowest cost. The best design of the reactor volume and the SST diameter at the optimum sludge concentration were specified with varying wastewater and sludge characteristics, temperature, sludge retention time (SRT) and peak flow rate. The effects of the influent wastewater characteristics, such as substrate concentration and unbiodegradable particulate fraction, were found to be considerable, but the effect of unbiodegradable soluble fraction was to be negligible. The effects of sludge settling characteristics, were also significant. SRT, as an operating parameter, was found to be an important factor for determining the optimum sludge concentration. However, the effect of temperature was found to be small. Furthermore, for designing a large scale wastewater treatment plant, the number of reactors or SSTs could be estimated, by dividing the total reactor volume or SST area. The new combined design procedure, proposed in this research, will be able to allow engineers to provide the best design of an activated sludge system with the lowest cost.

A Numerical Study of Effects of Body Shape on Cavity and Drag of Underwater Vehicle (몸체 형상이 수중운동체의 공동 발달과 항력특성에 미치는 영향에 대한 수치적 연구)

  • Kim, Hyoung-Tae;Kang, Kyung-Tae;Choi, Jung-Kyu;Jung, Young-Rae;Kim, Min-Jae
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.55 no.3
    • /
    • pp.252-264
    • /
    • 2018
  • The calculation of steady-state cavitating flows around Supercavitating Underwater Bodies (SUB's), which consist of a circular disk head (cavitator), a conical fore-body, a cylindrical middle-body and either a boat-tail or a flare-tail, are carried out. To calculate the axisymmetric cavitating flow, used is a commercial computational fluid dynamics code based on the finite volume method, Fluent. From the analysis of numerical results, the cavity and drag, affected by the fore-body and tail of the SUB's, are investigated. Firstly, the effect of the fore-body shape is investigated with the same disk cavitator and a cylindrical rear-body of fixed diameter. Then with the same cavitator and a fixed fore-body, the effect of the rear-body shape is investigated. Before the cavity generated by the cavitator covers the slant of fore-bodies sufficiently, the larger the cone angle of the fore-body(i.e., the shorter the slant length), the larger the drag and the slower the development of cavity. After the cavity covers the fore-body completely so that the pressure drag component of the body is vanished, the characteristics of drag-velocity curves are identical. Also, as the tail angle is bigger, the cavity generated by the cavitator is suppressed further and the drag becomes larger. The peak of the drag appears for the flare-tail, i.e., when the tail angle is positive(+). On the contrary, the trough of the drag appears for the boat-tail, i.e., when the tail angle is negative(-). When the tail angle is 5 degrees, the peak of the drag appears at the body speed of 80m/s and the value of the drag is 43% larger than that at the design speed of 100m/s. When the tail angle is -5 degrees, the trough of the total drag appears at 75m/s and that drag is 30% smaller than that of the cavitator, which means the rest of the body has a negative drag.

Thermal Insulation Effect of Inflatable Life Vest on the Drowned Individual estimated by Numerical Analysis (익수자 체온 저하에 미치는 팽창식 구명동의의 단열효과 수치 분석)

  • Kim, Sung Chan;Lee, Kyung Hoon;Hwang, Se Yun;Lee, Jin Sung;Lee, Jang Hyun
    • Journal of Navigation and Port Research
    • /
    • v.39 no.4
    • /
    • pp.285-291
    • /
    • 2015
  • Exposure to cold sea water can be life-threatening to the drowned individual. Although appropriate life jacket can be usually be provided for the buoyance at the drowning accident, heat loss can make the drowned individual experience the hypothermia. Inflatable life jackets filled with inflatable air pocket can increase the thermal protection as well as the buoyancy force. Because it is important to know how the human body behaves unde the different life jacket, present study compares the thermal insulation capacity of solid type life jacket with that of inflatable life jacket. In order to represent the insulation capacity of life jacket, thermal resistance is estimated based on the assumption of steady-state. Also, a transient three-dimensional thermal distribution of the thigh is analyzed by using finite element method implementing the Pennes bioheat equation. The finite element model is a segmental, multi-layered representation of the body section which considers the heat conduction within tissue, bone, fat and local blood flow rate.

Characteristics of Flux Decline in Microfiltration Capillary Membrane of Bentonite Colloidal Suspensions (정밀여과 모세관 막을 이용한 벤토나이트 콜로이드 현탁액의 투과유속 감소특성)

  • Nam Suk-Tae;Han Myeong-Jin
    • Membrane Journal
    • /
    • v.15 no.1
    • /
    • pp.52-61
    • /
    • 2005
  • Permeate flux decline in a microfiltration was analyzed by measuring the permeability of bentonite colloidal solution through polyethylene capillary membranes. The flux decline with time was due to the growth of cake layer on the membrane surface and to the pore blocking by particles. As the time approaches to steady state, the permeate flux is almost controlled by the cake filtration model. Faster flux decline at high trans-membrane pressure was attributed to the formation of denser packed cake layer and pore blocking. The ratio of permeate flux to the initial permeate flux, J/J₁, decreased with increasing the trans-membrane pressure, from 45% for 0.5 kg/sub f//㎠ to 38% for 2.0 kg/sub f//㎠. In comparing the ratio of each fouling component to the total fouling for the 0.5 kg/sub f//㎠ TMP condition, complete blocking was 23.4%, standard blocking was about 14.6% and cake filtration was 62.0%, respectively. Permeate flux through the membrane increases with cross flow velocity, and the effect of the variation of velocity is more significant at 1.0 kg/sub f//㎠ rather than at 2.0 kg/sub f//㎠ of the operation pressure. Permeate flux for the membrane having the average pore diameter of 0.34 ㎛ was higher than that for the membrane of 0.24 ㎛ pore size, with the higher flux with the low concentration of feed. On the operation using the membrane of 0.34 ㎛ pore, the pore blocking in the low concentration of 200 ppm is negligible relative to the pore blocking in the 1000 ppm feed.

Effects of Cu and K Addition on Catalytic Activity for Fe-based Fischer-Tropsch Reaction (Fe계 Fischer-Tropsch 반응에서 촉매활성에 대한 Cu와 K의 첨가 효과)

  • Lee, Chan Yong;Kim, Eui Yong
    • Clean Technology
    • /
    • v.25 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • Effects of the Cu and K addition and the reduction condition of Fe-based catalysts for Fischer-Tropsch reaction are studied in a continuous flow reactor in this research. The catalysts for the reaction were prepared by homogeneous precipitation followed by incipient wetness impregnation. Physicochemical properties of the $Al_2O_3$ supported Fe-based catalysts are characterized by various methods including X-ray diffraction (XRD), temperature programmed reduction (TPR), and scanning electron microscopy (SEM). Catalytic activities and stabilities of the Fe/Cu/K catalyst are investigated in time-on-stream for an extended reaction time over 216 h. It is found that a reduction of the catalysts using a mixture of CO and $H_2$ can promote their catalytic activities, attributed to the iron carbides formed on the catalysts surface by X-ray diffraction analysis. The addition of Cu induces a fast stabilization of the reaction reducing the time to reach at the steady state by enhancement of catalytic reduction. The addition of K to the catalysts increases the CO conversion, while the physical stability of catalyst decreases with potassium loading up to 5%. The Fe/Cu (5%)/K (1%) catalyst shows an enhanced long term stability for the Fischer-Tropsch reaction under the practical reaction condition, displaying about 15% decrease in the CO conversion after 120 h of the operation.