A numerical method for buckling analysis of built-up columns with stay plates

  • Djafour, M.;Megnounif, A.;Kerdal, D.;Belarbi, A.
    • Structural Engineering and Mechanics
    • /
    • v.26 no.4
    • /
    • pp.441-457
    • /
    • 2007
  • A new numerical model based on the spline finite strip method is presented here for the analysis of buckling of built-up columns with and without end stay plates. The channels are modelled with spline finite strips while the connecting elements are represented by a 3D beam finite element, for which the stiffness matrix is modified in order to ensure complete compatibility with the strips. This numerical model has the advantage to give all possible failure modes of built-up columns for different boundary conditions. The end stay plates are also taken into account in this method. To validate the model a comparative study was carried out. First, a general procedure was chosen and adopted. For each numerical analysis, the lowest buckling loads and modes were calculated. The basic or "pure" buckling modes were identified and their critical loads were compared with solutions obtained using analytical methods and/or other numerical methods. The results showed that the proposed numerical model can be used in practice to study the elastic buckling of built-up columns. This model is considered accurate and efficient for the local buckling of short columns and global buckling for slender columns.

Buckling Analysis of Built up Column with Stay Plates by the Generalized Differential Quadrature Method (GDQM에 의한 띠판을 갖는 조립 칼럼의 좌굴 해석)

  • 신영재;김재호;정인식
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.9
    • /
    • pp.462-474
    • /
    • 2001
  • In this paper, Generalized Differential Quadrature Method is applied to the buckling analysis of built-up columns without or with stay plates. numerical analysis using GDQM is carried out for various boundary conditions(simply supported conditions, fixed conditions, fixed-simply supported conditions), dimensionless stiffness parameter and dimensionless inertia moment parameter. The accuracy and convergence of solutions are compared with exact solutions of Gjelsvik to validate the results of GDQM. Results obtained by this method are as follows. 91) This method can yield the accurate numerical solutions using few grid points. (2) The buckling load of built-up column increases as the dimensionless stiffness parameter decreases. (3) The effects of boundary conditions on the buckling load are not considerable as the dimensionless stiffness parameter increases. (4) The buckling load of built-up column increases due to the stay plate.

  • PDF

A Study On the Corrosion Tendency of Bottom Plates and Corrosion Prevention Measures in Hazmat Tanks (위험물저장탱코밑판의 부식 성향분석 및 부식예방 방안에 관한 연구)

  • Choi, Jeong Soo;Ro, Kyung Jin
    • Journal of the Society of Disaster Information
    • /
    • v.4 no.1
    • /
    • pp.138-152
    • /
    • 2008
  • The most important factor in the maintenance of chemical industry facilities is related with deterioration and corrosion. Leakage of hazardous materials is likely to occur because the confirmation and maintenance of bottom plates are very difficult while the bottom corrosion of the massive hazmat-storage facilities is most dangerous especially. As a result of the analysis of the corrosion locations, areas, usage condition of 287 hazmat-storage tanks on this syudy, it is concluded that the main external corrosion factors are the inflow of moisture and the materials inducing corrosion in the air such as sodium chloride and the main internal corrosion factors are corrosion react caused by stay of seawater, sulfur and moisture in hazmat for a long time without appropriate discharges. It is anticipated that the corrosion of bottom plates can be restrained effectively by establishing the proper measures for the each corrosion cause.

  • PDF

Experimental Study on the Characteristics of Misaligned Self-equalizing Tilting Pad Thrust Bearing (자려 평형 틸팅 패드 스러스트 베어링의 정렬불량에 따른 베어링 특성에 관한 실험적 연구)

  • Song, AeHee;Jo, HyunJun;Choi, SeongPil;Kim, SeonJin
    • Tribology and Lubricants
    • /
    • v.36 no.1
    • /
    • pp.27-33
    • /
    • 2020
  • Self-equalizing tilting pad thrust bearings are usually employed in turbomachines to achieve high stability and reliability. A tilting pad bearing can incorporate self-equalizing links to handle the misalignment between the bearing and the thrust collar. In this popular design method, the pads sit on the upper-level plates and the lower-level plates stay on the retainer base. With misalignment, the pads that are heavily loaded are pushed down. Consequently, the link pushes up the pads on the opposite side, keeping the bearing surface parallel to the thrust collar surface. The self-equalizing link is used to handle the misalignment from the thermal and mechanical effects. In this study, the experimental investigation deals with the performance of self-equalizing tilting pad thrust bearings. The test rig for evaluating the performance of bearing is developed which can control the misalignment angle. Simultaneous measurements are taken for the force acting on each pad. Pad metal temperature and oil film thickness are functions of the shaft speed, bearing load, misalignment angle, and design of leveling plates. The effect of misalignment on bearing performance is discussed. The results demonstrate that the load on each pad depends on the test conditions(especially misalignment angle), and the load influences the performance of bearings.

An Experimental study on the Characteristics of the Emulsion Lubrication (이멀션윤활특성에 관한 실험적 연구)

  • 이종순;이봉구;정재련;지창헌
    • Tribology and Lubricants
    • /
    • v.2 no.2
    • /
    • pp.12-19
    • /
    • 1986
  • Using emulsion lubricant whose cooling effect and incombustibility are good and which is economical, I investigated lubricative mechanism and the behavior of scattered particles in the elastic fluid lubrication region with the line contact between rollers and plates and the light interference system. The results of the study are as follows: (1) The flow in the squeeze oil film is considered as comparatively wide clearance and narrow one, and in the former case the effect of the distribution of particles and the velocity on the flow. In the latter case, emulsion particles stay in the clearance an the oil film changes with the decrease of the oil film thickness. (2) In the wide clearance the velocity difference of the flow O/W or W/O emulsion is inverse proportional to the particle size. In the narrow clearance the distribution of the remained drops is different from one another and the scattered particles change more easily in O/W type than in W/O type. (3) At the beginning of the EHL the stagnation region with slow flowing velocity exists and the behavior at the region is different depending on the particle size. (4) By observing the dischromatic light interference line, emulsion oil passing through EHL region and the crack behavior at the beginning of EHL were found.

Study on Characteristics of Heat Transfer and Flow in Plate Heat Exchanger (판형 열교환기의 열전달과 유동특성에 대한 연구)

  • Jin, Zhen-Hua;Lee, Kwang-Sung;Ji, Myoung-Kuk;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1476-1483
    • /
    • 2009
  • In present work, experiments conducted to investigate the heat transfer characteristics and relationship between operating parameters and production of fresh water as output of the system. Plate Heat Exchanger (PHE) applied in vacuum evaporator for product fresh water that system intended to efficiently use low grade heat. PHE have become popular in chemical, power, food and refrigeration industries due to the efficient heat transfer performance, extremely compact design and flexibility of extend or modify to suit changed duty. The heat transfer part contains corrugated plates with 60 degree of chevron angle which verified by many researchers and commonly apply. Fresh water can be produced from saline water under near vacuum pressure by operating ejector. Consequently, evaporating temperature stay around $51-57^{\circ}C$ so it is possible to use any low grade heat source or renewable source. The maximum fresh water produced by freshwater generator with plat heat exchanger applied in the study was designed as 1.0 Ton/day.

  • PDF

The study of anterior cruciate ligament injury after a ski accident (스키에 의한 전방십자인대 손상에 대한 고찰)

  • Park, Ju-Hwan;Jun, Sung-Hwa;Yang, Nan-Hea;Kim, Yong-Kwon;Kim, Chi-Hyuk
    • Journal of Korean Physical Therapy Science
    • /
    • v.10 no.1
    • /
    • pp.222-231
    • /
    • 2003
  • The ACL(Anterior cruciate ligament) is the smallest of the four main ligaments of the knee, but it is the primary stabilizer. Injuries have a tendency to occur when the foot is firmly planted and the knee is twisted. Any sports that requires acceleration, change of direction and deceleration can increase the chances of suffering an ACL tear. The incidence of severe knee sprains that involve the ACL are at an all-time high. Since 1980, the number of these injuries have increased at least three-fold. Although the rate of increase has been much less dramatic since the middle 1980s, even the ultra-modem releasable ski binding has not been able to start reducing the incidence of ACL injuries. An ACL injury prevention program developed for downhill skiers by the Vermont Safety Research group emphasized increasing awareness of situations that can potentially result in an ACL injury and pre-planning strategies if events, leading to these situations, begin to fall in place. As part of the above study by Ettlinger et al., an educational prevent program was developed to teach these principles and thus reduce the rate of serious knee injuries. Four thousand instructors and patrol at 20 ski resorts who received the training had a 62% decline in serious knee injuries compared to a similar group that did not receive this training. Whenever you fall, try not to fully straighten your legs. Don't try to get up until you've stopped sliding(unless you are try to avoid an obstacle or other skier). When you're down, stay down. And don't land on your hand. So, if you feel yourself falling: arms forward, ski plates together, hands over knee. Then you will be able to save your ACL.

  • PDF

Use of resorbable mesh and fibrin glue for restoration in comminuted fracture of anterior maxillary wall

  • Yang, Jae-Hyuk;Chang, Suk Choo;Shin, Jin Yong;Roh, Si-Gyun;Lee, Nae-Ho
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.3
    • /
    • pp.175-180
    • /
    • 2018
  • Background: The facial bone has a complex structure compared to other bones, and various types of fractures can occur due to its characteristics. Among them, in comminuted fractures of anterior maxillary wall, multiple depressed and impacted bony segments cannot be reduced easily when performing internal fixation using plates and screws or wires, and inadequate restoration leads to a range of complications. This paper introduces an alternative technique using a resorbable mesh with fibrin glue to restore comminuted fractures of anterior maxillary wall. Methods: Thirteen patients were diagnosed with comminuted fractures of anterior maxillary wall between March 2017 and February 2018 in the authors' hospital. All patients with comminuted fractures of anterior maxillary wall underwent restoration using resorbable mesh with fibrin glue. The patients' demographics, causes of facial trauma, mean operation time, length of hospital stay, follow-up period, and complications were recorded. Results: No major complications and only one hypoesthesia of the skin area was noted. Three months after surgery, the hypoesthesia recovered completely. After surgery (mean, 3.9 months; range, 2-12 months), computed tomography showed that the bone fragments in all patients were fixed successfully in their anatomical places. Conclusion: In comminuted fractures of anterior maxillary wall, the use of a resorbable mesh with fibrin glue can be an advantageous and effective method for a successful restoration without complications.

Detection of Astrovirus Infection from Hospitalized Young Children Feces by Reverse Transcription-Polymerase Chain Reaction (중증 위장관염 소아의 대변검체에서 역전사-중합효소 연쇄반응을 이용한 Astrovirus 검출)

  • Park, Hae-Kyung;Woo, So-Youn;Seoh, Ju-Young;Chong, Young-Hae;Seo, Jeong-Wan
    • The Journal of the Korean Society for Microbiology
    • /
    • v.34 no.5
    • /
    • pp.453-459
    • /
    • 1999
  • Astrovirus is frequently associated with diarrhea in children. It can not be readily isolated by cell culture, and an electronmicroscope is usually used for detection of this agent. Recently in 1995 a combined method of reverse transcription-polymerase chain reaction (RT-PCR) was designed for easier detection of astrovirus, which is based on the conserved sequence in 3'-end of genomes of the 7 known serotypes of human astrovirus. As of yet there has not been any report of astrovirus data in Korea using the RT-PCR methods. The purpose of this study was to detect astrovirus incidence, severity of symptoms, seasonal variation and co infection rate with rotavirus in Korean children inpatients with diarrhea. Fecal specimens from 61 young children hospitalized with gasteroenteritis Korea from Jan. 1996 through Mar. 1997. They were examined for astroviurs infection by RT-PCR method. Results are as follows:1. Astrovirus was detected at 9.8% (6/61) from fecal specimens of children with severe diarrhea by EIA using monoclonal antibody coated plates. 2. Astorvirus was detected at 29.5% (18/61) from fecal specimens of children with severe diarrhea by RT-PCR. 3. The age of the 18 children affected by astrovirus ranged from 2 monthes to 7 years with mean of 3.0 years. 4. Mean hospital stay of the 18 children was 6.1 days. 5. Five (27.8%) astrovirus RT-PCR positive strains were confirmed in November and in December, respectively out of 18 specimens in total. 6. Astrovirus coinfection with rotavirus type G1 was confirmed in 15/16 specimens (93.8%), and with type G2 was in 1/16 specimens (6.3%).

  • PDF