• Title/Summary/Keyword: stator coil

Search Result 159, Processing Time 0.03 seconds

Inductance and Push/pull Effects of Moving Coil Type LOA with Consideration of a Mover Positions (가동자 위치에 따른 가동코일형 LOA의 인덕턴스 변화와 Push/pull 효과)

  • Jang, S.M.;Jeong, S.S.;Kweon, C.;Moon, S.J.;Jung, T.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.900-902
    • /
    • 2000
  • A moving-coil-type linear oscillatory actuator is consisted of the NdFeB permanent magnets with high specific energy as the stator, a coil-wrapped nonmagnetic hollow rectangular structure and an iron core as a pathway for magnetic flux. The inductance of moving coil and the push/pull effect is obtained from the permeance model of LOA with the open magnetic circuit. The analytical method are verified using the 2D finite element method.

  • PDF

Analysis of the Encoder Composite Signal for a Absolute Position Detection of the Permanent Magnet Type Synchronous Motor (영구자석형 동기전동기의 절대 위치 검출을 위한 엔코더 복합 신호의 분석)

  • Kim, Jin-Ae;Joo, Jae-Hun;Jeong, Se-Young;Choi, Jung-Keyng
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.180-184
    • /
    • 2007
  • For driving a sinusoidal type permanent magnet synchronous motor with a maximum continuous torque, a $120^0$ delayed three phase sinusoidal current input which matched with the absolute rotor position is needed at a stator coil. So, the detection of absolute rotor position is required inevitably. Thus the right angle relationship between stator magnetic field and rotor magnetic field has to be preserved at a stator by this commutation action. The detection of a absolute position for the commutation can be made generally by the output signal analysis of the encoder attached at a motor shaft. This study purposes to design signal processing logic circuits which can detect the absolute position of motor with a modem encoder system and generate the three reference wave for making sinusoidal current input at a stator coil.

  • PDF

Analysis of the Encoder Composite Signal for a Absolute Position Detection of the Synchronous Motor (동기 전동기의 절대 위치 검출을 위한 엔코더 복합 신호의 분석)

  • Joo, Jae-Hun;Kim, Dong-Hyun;Choi, Jung-Keyng
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.5
    • /
    • pp.1018-1024
    • /
    • 2011
  • For the driving of the sinusoidal type permanent magnet synchronous motor with a maximum continuous torque, the 1200 delayed three phase sinusoidal current inputs which matched with the absolute rotor position are needed at the stator coil. Therefore, the detection of a absolute rotor position is required inevitably. And the right angle relationship between stator magnetic field and rotor magnetic field has to be preserved at a stator by this commutation action. The detection of a absolute position for the commutation can be made generally by the output signal analysis of the encoder attached at a motor shaft. The purposes of this study are to design signal processing logic circuits which could detect the absolute position of motor with a modern encoder system and generate the three reference wave for making sinusoidal current input at a stator coil.

Assessment of Insulation Aging in 6.6 kV Class High Voltage Motor Stator Windings (6.6 kV급 고압전동기 고정자 권선의 절연열화 평가)

  • Kim, Hee-Dong;Kim, Byong-Han
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.11
    • /
    • pp.1067-1071
    • /
    • 2006
  • Prior to destructive testing, diagnostic tests were performed in ten high voltage motors. Diagnostic tests included polarization infer, ac current, dissipation factor$(tan{\delta})$ and partial discharge magnitude. The rewind of motet slater insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. No. 8 motor failed near rated voltage of 19.0 kV. The breakdown voltage of No. 4 motet was 7.0 kV which is lower that expected for good quality coils in 6.6 kV class motors. The failure was located in a line-end coil at the exit from the core slot. These two motors began operation in 1994. While testing No. 7 motor, flashover occurred between the stator winding and the stator frame at 15 kV. The relationship between the diagnostic test and the drop in insulation breakdown voltage was analyzed.

Research of Degradation Properties on Stator Coil of Traction Motor (견인전동기 고정자 코일의 열화특성 연구)

  • Jang, Dong-Uk;Byun, Yeun-Sub;Wang, Jong-Bae;Park, Hyun-June;Kim, Gil-Dong;Han, Young-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1430-1432
    • /
    • 2001
  • In this paper, 200-class insulation system for form-wound stator coils is designed for form-wound stator coils is designed for AC traction driven with VVVF inverter. Model coils are made to embody all essential elements representing a winding insulation system and structure. Acceleration degradation for model coils is applied exposure to heat(235$^{\circ}C$). In order to investigate the condition of the coils and to determine their insulation reliability, high voltage test and the dielectric properties such as dielectric loss and capacitance are performed. Also, partial discharge measurement is investigated for internal defects.

  • PDF

A Study on the Partial Discharge Wave Propagation along Stator Winding (회전기 권선의 펄스 전송특성 연구)

  • Kang, Dong-Sik;Sim, Woo-Yong;Hwang, Don-Ha;Kim, Yong-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.738-740
    • /
    • 2003
  • A lot of R&D on the diagnosis of stator winding insulation for large rotating machines has been carried out since the 1970s. The on-line partial discharge measurement has proved to be an effective technique in the evaluation of the state of stator insulation in high voltage rotating machines. It is well known that if the discharge pulses propagate through the winding conductor, they are attenuated and delayed. In the present study, to investigate the attenuation and the time delay of discharge pulses through the winding conductor, a series of tests were conducted using a model coils and slot. Thus it could be concluded that while the high frequency pulse propagates in radiation or end-winding coupling modes, the low frequency one does in a series mode through the coil conductor.

  • PDF

Dynamic Characteristics of Moving Coil Type Linear Oscillatory Actuator (가동코일형 리니어 왕복 액추에이터의 동특성)

  • Jang, S.M.;Jeong, S.S.;Kweon, C.;Park, H.C.;Moon, S.J.;Park, C.I.;Chung, T.Y.
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.3
    • /
    • pp.180-187
    • /
    • 2000
  • A moving-coil-type linear oscillatory actuator(LOA) consists of the NdFeB permanent magnets with high specific energy as the stator, a coil-wrapped nonmagnetic hollow rectangular structure. The LOA system was represented by the voltage equation of coil and the mechanical equation of motion. This set of equations was manipulated in state-space form. The EMF constant kE of equation parameters in state-space form can be obtained by using the induced voltage in armature coils at open circuit test. kE and other parameters provide the system matrices and transfer function for frequency response and dynamic simulation. Voltage source inverter-fed LOA is examined aiming to compare with results of simulation.

  • PDF

Design and Characteristics of Linear Motor Damper for Vibration Control (진동제어용 리니어 모터 탬퍼의 설계 및 특성)

  • Jang, S.M.;Jeong, S.S.;Park, H.D.;Ham, S.Y.;Kim, H.I.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.880-882
    • /
    • 2001
  • A moving-coil-type linear oscillatory actuator is consisted of the NdFeB permanent magnets with high specific energy as the stator, a coil-wrapped nonmagnetic hollow rectangular structure and an iron core as a pathway for magnetic flux. The inductance of moving coil and the push/pull effect is obtained from the permeance model of LOA with the open magnetic circuit. The analytical method are verified using the 2D finite element method.

  • PDF

Test results of a 5 kW fully superconducting homopolar motor

  • Lee, J.K.;Park, S.H.;Kim, Y.;Lee, S.;Joo, H.G.;Kim, W.S.;Choi, K.;Hahn, S.Y.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.1
    • /
    • pp.35-39
    • /
    • 2013
  • The superconducting Homopolar motor is manufactured and tested. Homopolar motor system is simple and solid as the field coil of the motor is fixed near the stator coil without rotating system. In this paper, a 5 kW fully superconducting homopolar motor which has high temperature superconducting armature and field coils is manufactured and tested in liquid nitrogen. The critical current test results of the used 2G superconducting wire, pancake coil for rotor winding and race-track coils for armature winding are reported. Also, the test result of rotating and operating performance is presented. The operating frequency is to be 5 Hz for low-speed rotating. The developed fully superconducting Homopolar motor is the world's first.

Drive of Single-phase Switched Reluctance Motors Using Search Coils (서치코일을 이용한 단상 SRM의 구동)

  • Shin, D.S.;Yang, H.Y.;Lim, Y.C.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.750-753
    • /
    • 2005
  • This paper presents a method of detecting rotor position for single phase Switched Reluctance Motors(SRMs) using searchs coil. In the single phase SRM, mainly Hall effect sensors or photo interrupters have been used to detect the rotor position. But these sensors cause high cost and increase the volume of the motor, Furthermore when the motor is used in very hostile environment like high temperature or pressure, its reliability goes down. In this paper, low cost and robust characteristics of rotor position detection method are focused in order to compensate for disadvantage of existing sensors. Search coils wound around the stator pole are used for detection of the rotor position in single phase SRM. Rotor position detection is achieved through electromotive force patterns induced by time-varying flux linkage in the search coil. The validity of the method is verified by experimental results.

  • PDF