An Accuracy Analysis of Run-test and RA(Reverse Arrangement)-test for Assessing Surface EMG Signal Stationarity (표면근전도 신호의 정상성 검사를 위한 Run-검증과 RA-검증의 정확도 분석)

  • Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.291-296
    • /
    • 2014
  • Most of the statistical signal analysis processed in the time domain and the frequency domain are based on the assumption that the signal is weakly stationary(wide sense stationary). Therefore, it is necessary to know whether the surface EMG signals processed in the statistical basis satisfy the condition of weak stationarity. The purpose of this study is to analyze the accuracy of the Run-test, modified Run-test, RA(reverse arrangement)-test, and modified RA-test for assessing surface EMG signal stationarity. Six stationary and three non-stationary signals were simulated by using sine wave, AR(autoregressive) modeling, and real surface EMG. The simulated signals were tested for stationarity using nine different methods of Run-test and RA-test. The results showed that the modified Run-test method2 (mRT2) classified exactly the surface EMG signals by stationarity with 100% accuracy. This finding indicates that the mRT2 may be the best way for assessing stationarity in surface EMG signals.

An extension of Markov chain models for estimating transition probabilities (추이확률의 추정을 위한 확장된 Markov Chain 모형)

  • 강정혁
    • Korean Management Science Review
    • /
    • v.10 no.2
    • /
    • pp.27-42
    • /
    • 1993
  • Markov chain models can be used to predict the state of the system in the future. We extend the existing Markov chain models in two ways. For the stationary model, we propose a procedure that obtains the transition probabilities by appling the empirical Bayes method, in which the parameters of the prior distribution in the Bayes estimator are obtained on the collaternal micro data. For non-stationary model, we suggest a procedure that obtains a time-varying transition probabilities as a function of the exogenous variables. To illustrate the effectiveness of our extended models, the models are applied to the macro and micro time-series data generated from actual survey. Our stationary model yields reliable parameter values of the prior distribution. And our non-stationary model can predict the variable transition probabilities effectively.

  • PDF

Synthesis, Characterization and Enhanced Selectivity in RP-HPLC of Polar Carbonyl Group Embedded Poly (Vinyl Octadecanoate) Grafted Stationary Phase by Simple Heterogeneous "Graft from" Technique

  • Rana, Ashequl A.;Karim, Mohammad Mainul;Takafuji, Makoto
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.1
    • /
    • pp.77-82
    • /
    • 2011
  • A new high performance liquid chromatograpgy (HPLC) stationary phase that possesses an internal carbonyl functional group is synthesized by heterogeneous "graft from" method. This new stationary phase, poly (vinyl octadecanoate) grafted silica (Sil-2) is then characterized by different physico-chemical methods such as diffuse reflectance infrared fourier transform, suspension state $^1H$ NMR, solid state $^{13}C$ CP/MAS NMR, $^{29}Si$ CP/MAS NMR, elemental analysis and thermogravimetric analysis. Chromatographic properties of Sil-2 were evaluated under reversed phase condition by separating polycyclic aromatic hydrocarbons (PAHs) and comparing the chromatographic results with those on polymeric as well as monomeric octadecylated silica stationary phases.

Utilization of Rigid Barrier to Simulate Car to Car Crash of Two Identical Vehicles (고정벽을 활용한 차대차 경사충돌 재현)

  • Junsuk, Bae;Ho, Kim;Young Myoung, So
    • Journal of Auto-vehicle Safety Association
    • /
    • v.14 no.4
    • /
    • pp.21-26
    • /
    • 2022
  • Commercial use of autonomous vehicles is to come soon. So far most of responsibility of the accident is on the human driver with conventional vehicles whereas that will be on the car OEM and transportation related organizations with autonomous vehicles, which asks car OEM's and government to do vast study of car crash in various conditions. Test protocols need amendment and to be newly enacted to reflect new findings from the study aforementioned. Rigid stationary barrier and moving or stationary deformable barrier as well as car to car test which is same as actual accident can be utilized to simulate the crash happening on the road. Among those 3 test methods, rigid stationary barrier is most economic and has good repeatability. Limitation as well as advantage of the rigid stationary barrier is studied through comparison between car to car crash and oblique rigid barrier crash.

Vibration analysis of a multi-span beam subjected to a moving point force using spectral element method

  • Jeong, Boseop;Kim, Taehyun;Lee, Usik
    • Structural Engineering and Mechanics
    • /
    • v.65 no.3
    • /
    • pp.263-274
    • /
    • 2018
  • In this study, we propose a frequency domain spectral element method (SEM) for the vibration analysis of a multi-span beam subjected to a moving point force. This study is an extension of the authors' previous study for a single-span beam subjected to a moving point force, where the two-element model-based SEM was applied. In this study, each span of a multi-span beam is represented by the Timoshenko beam model and the moving point force is transformed into the frequency domain as a series of each stationary point force distributed on the multi-span beam. The span at which a stationary point force is located is represented by two-element model, but all other spans are represented by one-element models. The vibration responses to a moving point force are obtained by superposing all individual vibration responses generated by each stationary point force. The high accuracy and computational efficiency of the proposed SEM are verified by comparing the solutions by SEM with exact analytical solutions by the integral transform method (ITM) as well as the solutions by the finite element method (FEM).

Modal parameter identification of civil structures using symplectic geometry mode decomposition

  • Feng Hu;Lunhai Zhi;Zhixiang Hu;Bo Chen
    • Wind and Structures
    • /
    • v.36 no.1
    • /
    • pp.61-73
    • /
    • 2023
  • In this article, a novel structural modal parameters identification methodology is developed to determine the natural frequencies and damping ratios of civil structures based on the symplectic geometry mode decomposition (SGMD) approach. The SGMD approach is a new decomposition algorithm that can decompose the complex response signals with better decomposition performance and robustness. The novel method firstly decomposes the measured structural vibration response signals into individual mode components using the SGMD approach. The natural excitation technique (NExT) method is then used to obtain the free vibration response of each individual mode component. Finally, modal natural frequencies and damping ratios are identified using the direct interpolating (DI) method and a curve fitting function. The effectiveness of the proposed method is demonstrated based on numerical simulation and field measurement. The structural modal parameters are identified utilizing the simulated non-stationary responses of a frame structure and the field measured non-stationary responses of a supertall building during a typhoon. The results demonstrate that the developed method can identify the natural frequencies and damping ratios of civil structures efficiently and accurately.

Hydrophilic Interaction Liquid Chromatography (HILIC 분석법 개발을 위한 지능형 솔루션)

  • Matt James;Colin Pipe;Mark Fever;Jen Field;Seungho Chae
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.6.1-6.9
    • /
    • 2024
  • The document is a white paper on Hydrophilic Interaction Liquid Chromatography (HILIC) analysis method development. HILIC is a type of chromatography that uses an organic/aqueous mobile phase and a polar stationary phase. In HILIC, water is a strong solvent, and unlike in Reversed Phase Liquid Chromatography (RPLC), increasing the proportion of water in the mobile phase reduces the retention time of the analyte. The paper discusses when to consider HILIC analysis methods, the advantages of HILIC, and the challenges often encountered due to the lack of understanding of HILIC mechanisms compared to RPLC. It also provides a systematic flowchart for intelligent solutions for HILIC analysis method development, which includes a three-step approach for chromatography analysis method development. The first step involves gathering as much information as possible about the analyte (e.g., pKa, log P, log D). The second step involves analyzing the sample under different pH conditions using three HILIC columns in either isocratic or gradient mode to identify the suitable column/pH combination for the analyte. The third step involves optimizing the separation by investigating other parameters such as temperature and ionic strength, and assessing the robustness of the method. The paper emphasizes that the selection of the appropriate stationary/mobile phase combination, based on the differences between the HILIC stationary phases and the mobile phase pH, can provide high selectivity in the analysis. This step-by-step approach can help users develop an efficient analysis method.

  • PDF

A Study on the Near-Field Stresses and Displacement of a Stationary Interfacial Crack in Two Dissimilar Isotropic Bimaterials (두 상이한 등방성 이종재료 정지계면균열의 선단 응력장과 변위장에 관한 연구)

  • Shin, Dong-Chul;Hawong, Jai-Sug;Nam, Jeong-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.12
    • /
    • pp.1897-1905
    • /
    • 2004
  • In many part of machines or structures that made of bimaterial bonded with two dissimilar materials, most failures occur at their interface. Therefore, the accurate analysis of fracture characteristics and the evaluation of mechanical strength for interfacial crack are essential when we design those structures. In this research, stress and displacement components in the vicinity of stationary interfacial crack tip in the two dissimilar isotropic bimaterials are established. Hereafter, the stress components established in this research can be applied to the photoelastic hybrid method which can be used to analyze the fracture behavior of the two dissimilar isotropic bimaterials.

PENALIZED APPROACH AND ANALYSIS OF AN OPTIMAL SHAPE CONTROL PROBLEM FOR THE STATIONARY NAVIER-STOKES EQUATIONS

  • Kim, Hong-Chul
    • Journal of the Korean Mathematical Society
    • /
    • v.38 no.1
    • /
    • pp.1-23
    • /
    • 2001
  • This paper is concerned with an optimal shape control problem for the stationary Navier-Stokes system. A two-dimensional channel flow of an incompressible, viscous fluid is examined to determine the shape of a bump on a part of the boundary that minimizes the viscous drag. by introducing an artificial compressibility term to relax the incompressibility constraints, we take the penalty method. The existence of optima solutions for the penalized problem will be shown. Next, by employing Lagrange multipliers method and the material derivatives, we derive the shape gradient for the minimization problem of the shape functional which represents the viscous drag.

  • PDF

Liquid Chromatographic Enantiomer Separation of α-Amino Acid Esters as Nitrobenzoxadiazole Derivatives Using Polysaccharide-Derived Chiral Stationary Phases

  • Islam, Md. Fokhrul;Lee, Wonjae
    • Journal of Integrative Natural Science
    • /
    • v.8 no.2
    • /
    • pp.111-116
    • /
    • 2015
  • Liquid chromatographic enantiomer separation of ${\alpha}$-amino acid esters as nitrobenzoxadiazole (NBD) derivatives was performed using several chiral stationary phases (CSPs) based on polysaccharide derivatives under fluorescence detection. For enantiomer separation by normal HPLC, the non-aqueous derivatization method of ${\alpha}$-amino acid esters for NBD analytes was introduced. Among the six CSPs used in this study, the performance of Chiralpak IA was superior for enantiomer resolution of NBD derivatives of several ${\alpha}$-amino acid methyl esters. Also the convenient analytical method using polysaccharide-derived CSPs developed in this study was applied to determine the optical purity of ${\alpha}$-amino acids esters. It was investigated that the enantiomeric impurity levels of 0.02-1.73% were found after determination of enantiomeric purities of several commercially available L-amino acid methyl esters. It is expected to be quite useful for enantiomer separation of other ${\alpha}$-amino acid esters as NBD derivatives by normal HPLC.