• 제목/요약/키워드: static tests

검색결과 1,516건 처리시간 0.026초

복합재료 적층판의 정 강도 해석 및 실험 (The Static Strength Analysis and Experiment of Composite Laminate)

  • 김인권;공창덕;방조혁
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2001년도 제16회 학술발표회 논문초록집
    • /
    • pp.104-107
    • /
    • 2001
  • The purpose of this work is to investigate the static strength, the stress distribution, and the failure process of quasi-isotropic composite laminates made of two different matrices when loading directions are changed. We carried out static tests of $[0/-60/+60]_s$ and $[+30/-30/90]_s$ laminates. Two types of matrices used are AS4/epoxy and AS4/PEEK. The damage mechanisms of the quasi-isotropic laminate, $[0/-60/+60]_s$, strongly depend on the load direction applied to the laminate.

  • PDF

풍화암 소켓 대구경말뚝의 축하중 전이거동 (Axial Load Transfer Behavior of a Large Diameter Pile socketed into weathered rock)

  • 정창규;임태경;황근배;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.390-397
    • /
    • 2002
  • In this study, static pile load tests with load transfer measurement for a pile socketed into weathered rocks were performed. Axial load transfers during static pile load test were measured and analyzed. Three large diameter piles socketed into weathered rock were behavior behaved as friction pile.

  • PDF

송전용 고분자 애자의 정적 및 동적인 상태에서 장기 기계적 특성 연구 (A Study on the Long-term Mechanical Properties Under Static and Cyclic State of Composite Insulators for Transmission Lines)

  • 김수연;김영성;홍진영;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.869-871
    • /
    • 1998
  • The extensive use of composite insulators for transmission lines can ultimately be justified only on long-term qualification tests. The actual load working on the insulator in the field is not static load but cyclic load. So in this paper, we discussed an examination of aging degradation by mechanical performance of composite insulators under static tension load and cyclic tension load. and also described useful approaches for analyzing their long term performance so as to develop reliable composite insulators. The static and cyclic tension load-time test data were examined by Weibull distribution for their capability of presuming long term performance. It was found that cyclic tension loads were more severe than static tension loads. The results also indicate that it may be relevant for an user to select composite insulators on basis of their performance under cyclic tension loads than static tension loads.

  • PDF

Analysis of three dimensional equivalent static wind loads of symmetric high-rise buildings based on wind tunnel tests

  • Liang, Shuguo;Zou, Lianghao;Wang, Dahai;Huang, Guoqing
    • Wind and Structures
    • /
    • 제19권5호
    • /
    • pp.565-583
    • /
    • 2014
  • Using synchronous surface pressures from the wind tunnel test, the three dimensional wind load models of high-rise buildings are established. Furthermore, the internal force responses of symmetric high-rise buildings in along-wind, across-wind and torsional directions are evaluated based on mode acceleration method, which expresses the restoring force as the summation of quasi-static force and inertia force components. Accordingly the calculation methods of equivalent static wind loads, in which the contributions of the higher modes can be considered, of symmetric high-rise buildings in along-wind, across-wind and torsional directions are deduced based on internal forces equivalence. Finally the equivalent static wind loads of an actual symmetric high-rise building are obtained by this method, and compared with the along-wind equivalent static wind loads obtained by China National Standard.

Investigations on a vertical isolation system with quasi-zero stiffness property

  • Zhou, Ying;Chen, Peng
    • Smart Structures and Systems
    • /
    • 제25권5호
    • /
    • pp.543-557
    • /
    • 2020
  • This paper presents a series of experimental and numerical investigations on a vertical isolation system with quasi-zero stiffness (QZS) property. The isolation system comprises a linear helical spring and disk spring. The disk spring is designed to provide variable stiffness to the system. Orthogonal static tests with different design parameters are conducted to verify the mathematical and mechanical models of the isolation system. The deviations between theoretical and test results influenced by the design parameters are summarized. Then, the dynamic tests for the systems with different under-load degrees are performed, including the fast sweeping tests, harmonic excitation tests, and half-sine impact tests. The displacement transmissibility, vibration reduction rate, and free vibration response are calculated. Based on the test results, the variation of the transmission rule is evaluated and the damping magnitudes and types are identified. In addition, the relevant numerical time history responses are calculated considering the nonlinear behavior of the system. The results indicate that the QZS isolation system has a satisfactory isolation effect, while a higher damping level can potentially promote the isolation performance in the low-frequency range. It is also proved that the numerical calculation method accurately predicts the transmission character of the isolation system.

정상인의 자세와 시각 교란에 따른 정적 균형능력의 변화 (Evaluation of Static Balance in Postural Tasks and Visual Cue in Normal Subjects)

  • 서삼기;김수현;김태열
    • The Journal of Korean Physical Therapy
    • /
    • 제21권4호
    • /
    • pp.51-56
    • /
    • 2009
  • Purpose: This study examined the difference in the static balance ability according to the visual cues and postural tasks in normal subjects. Methods: Thirty participants (12 male, 18 female; mean age $24.63\pm1.43$ years) stood barefoot on a force platform in a one-legged stance, tandem Romberg stance and tandem Romberg with neck extension stance with a visual cue open and closes. The static balance was assessed by the center of pressure (CoP), surface electromyography root mean square (RMS) of the leg muscles according to the stance position. Results: In the CoP tests, the difference in the unit path length and circumference area was affected by the visual cue according to the stance posture (p<0.01). In the RMS tests, the difference in the tibialis anterior and medial gastrocnemius muscle was affected by visual cue in accordance with the stance posture (p<0.01). Conclusion: The visual cue and postural task affect the balance ability in normal subjects. Therefore, this study provides clinical evidence that the balance and postural control can be improved. Therapeutic intervention, such as an obstacle course, and a lower leg muscle performance program with a change in the base of support can affect the balance and postural control.

  • PDF

소형항공기용 왕복엔진의 정적 성능시험 연구 (A Study on the Static Performance Test of a Reciprocating Engine for Small Aircraft)

  • 김근배;안석민;김근택;최선우
    • 한국추진공학회지
    • /
    • 제7권3호
    • /
    • pp.53-60
    • /
    • 2003
  • 한국항공우주연구원에서 개발 중인 소형항공기와 관련하여 지상에서 왕복엔진의 정적 성능을 측정하기 위한 시험장치를 개발하였다. 시험장치는 Pusher형 추진시스템을 장착하고 구동하는 장치와 엔진의 기본적인 작동 감시 및 엔진 토크와 프로펠러 추력을 비롯한 여러 성능 변수들을 측정하고 처리하는 데이터 획득 장치로 구성되었다 먼저 기본 작동시험에서 도출된 성능데이터를 원래 엔진데이터와 비교 분석하여 시험장치의 기능을 검증하였다. 성능시험은 3단계에 걸쳐 다양한 시험조건에서 수행되었으며, 엔진의 흡기압력과 토크, 배압, 연료유량, 그리고 프로펠러의 정지추력을 측정하고 분석하였다.

Utilizing piezovibrocone in marine soils at Tauranga Harbor, New Zealand

  • Jorat, M. Ehsan;Morz, Tobias;Moon, Vicki;Kreiter, Stefan;de Lange, Willem
    • Geomechanics and Engineering
    • /
    • 제9권1호
    • /
    • pp.1-14
    • /
    • 2015
  • Piezovibrocones have been developed to evaluate the liquefaction potential of onshore soils, but have not yet been utilized to evaluate the in-situ liquefaction behavior of offshore marine and volcanoclastic sediments. Two static and vibratory CPTu (Cone Penetration Tests) were performed at Tauranga Harbor, New Zealand. The lithology is known from nearby drillholes and the influence of vibration on different types of marine soils is evaluated using the reduction ratio (RR) calculated from static and vibratory CPTu. A sediment layer with high potential for liquefaction and one with a slight reaction to cyclic loading are identified. In addition to the reduction ratio, the liquefaction potential of sediment is analyzed using classic correlations for static CPTu data, but no liquefaction potential was determined. This points to an underestimation of liquefaction potential with the classic static CPTu correlations in marine soil. Results show that piezovibrocone tests are a sensitive tool for liquefaction analysis in offshore marine and volcanoclastic soil.

Static and fatigue performance of stud shear connector in steel fiber reinforced concrete

  • Xu, Chen;Su, Qingtian;Masuya, Hiroshi
    • Steel and Composite Structures
    • /
    • 제24권4호
    • /
    • pp.467-479
    • /
    • 2017
  • The stud is one of the most frequently used shear connectors which are important to the steel-concrete composite action. The static and fatigue behavior of stud in the steel fiber reinforced concrete (SFRC) were particularly concerned in this study through the push-out tests and analysis. It was for the purpose of investigating and explaining a tendency proposed by the current existing researches that the SFRC may ameliorate the shear connector's mechanical performance, and thus contributing to the corresponding design practice. There were 20 test specimens in the tests and 8 models in the analysis. According to the test and analysis results, the SFRC had an obvious effect of restraining the concrete damage and improving the stud static performance when the compressive strength of the host concrete was relatively low. As to the fatigue aspect, the steel fibers in concrete also tended to improve the stud fatigue life, and the favorable tensile performance of SFRC may be the main reason. But such effect was found to vary with the fatigue load range. Moreover, the static and fatigue test results were compared with several design codes. Particularly, the fatigue life estimation of Eurocode 4 appeared to be less conservative than that of AASHTO, and to have higher safety redundancy than that of JSCE hybrid structure guideline.

변위에 기초한 동하중에서 변환된 등가정하중하에서의 구조최적설계 (Structural Optimization under Equivalent Static Loads Transformed from Dynamic Loads Based on Displacement)

  • 강병수;최우석;박경진
    • 대한기계학회논문집A
    • /
    • 제24권8호
    • /
    • pp.1949-1957
    • /
    • 2000
  • All the loads in the real world act dynamically on structures. Since dynamic loads are extremely difficult to handle in analysis and design, static loads are utilized with dynamic factors. The dyna mic factors are generally determined based on experiences. Therefore, the static loads can cause problems in precise analysis and design. An analytical method based on modal analysis has been proposed for the transformation of dynamic loads into equivalent static load sets. Equivalent static load sets are calculated to generate an identical displacement field in a structure with that from dynamic loads at a certain time. The process is derived and evaluated mathematically. The method is verified through numerical tests. Various characteristics are identified to match the dynamic and the static behaviors. For example, the opposite direction of a dynamic load should be considered due to the vibration response. A dynamic bad is transformed to multiple equivalent static loads according to the number of the critical times. The places of the equivalent static load can be different from those of the dynamic load. An optimization method is defined to use the equivalent static loads. The developed optimization process has the same effect as the dynamic optimization which uses the dynamic loads directly. Standard examples are solved and the results are discussed