• 제목/요약/키워드: static design

검색결과 3,384건 처리시간 0.028초

Evaluation of static response in stress-ribbon concrete pedestrian bridges

  • Stavridis, Leonidas T.
    • Structural Engineering and Mechanics
    • /
    • 제34권2호
    • /
    • pp.213-229
    • /
    • 2010
  • An analytical method is proposed for the evaluation of the static response of a prestresse-dribbon concrete pedestrian bridge, which may also be applied for the roofing of large areas. On the basis of an established analogy with a suspension bridge system, a procedure is presented for the prestresse-dribbon direct analysis, leading to the introduction of two dimensionless parameters as governing factors of the design, namely the thinness and the prestressing steel ratio. The exposed procedure, applied by a simple computer program, allows a quick evaluation of the response and permits the investigation of the influence of the aforementioned parameters on it, by means of comprehensive diagrams. The presented diagrams may be directly used for the preliminary design of a pedestrian bridge of this type, for the whole practical range of span lengths. A design example is also included, showing the applicability of the proposed procedure.

리어가이더 선단각도에 따른 룸에어콘용 관류홴의 공력성능에 관한 실험적 연구 (Experimental Study on the Aerodynamic Performance of a Cross-Flow Fan for the Various Leading Angles of a Rear-Guider for a Room Air-Conditioner)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제17권3호
    • /
    • pp.35-43
    • /
    • 2013
  • Generally, the chassis of an indoor RAC is composed of a rear-guider and a stabilizer. The aerodynamic performance of a cross-flow fan is strongly influenced by the various design factors of the chassis of an indoor RAC. The purpose of this paper is to select the optimum design factors through the aerodynamic performance of a cross-flow fan. The design factors are the leading angle of a rear-guider (${\theta}_1$), a stabilizer setup angle(${\theta}_2$), a rear-guider clearance(${\epsilon}_1$), and a stabilizer clearance(${\epsilon}_2$), respectively. As a result, the optimum design factors of an indoor RAC can be presented as a combination of ${\theta}_1=33^{\circ}$, ${\theta}_2=55^{\circ}$, ${\epsilon}_1=6{\sim}8mm$, and ${\epsilon}_2=7mm$ through the analysis of a static pressure coefficient and a static pressure efficiency.

On the progressive collapse resistant optimal seismic design of steel frames

  • Hadidi, Ali;Jasour, Ramin;Rafiee, Amin
    • Structural Engineering and Mechanics
    • /
    • 제60권5호
    • /
    • pp.761-779
    • /
    • 2016
  • Design of safe structures with resistance to progressive collapse is of paramount importance in structural engineering. In this paper, an efficient optimization technique is used for optimal design of steel moment frames subjected to progressive collapse. Seismic design specifications of AISC-LRFD code together with progressive collapse provisions of UFC are considered as the optimization constraints. Linear static, nonlinear static and nonlinear dynamic analysis procedures of alternate path method of UFC are considered in design process. Three design examples are solved and the results are discussed. Results show that frames, which are designed solely considering the AISC-LRFD limitations, cannot resist progressive collapse, in terms of UFC requirements. Moreover, although the linear static analysis procedure needs the least computational cost with compared to the other two procedures, is the most conservative one and results in heaviest frame designs against progressive collapse. By comparing the results of this work with those reported in literature, it is also shown that the optimization technique used in this paper significantly reduces the required computational effort for design. In addition, the effect of the use of connections with high plastic rotational capacity is investigated, whose results show that lighter designs with resistance to progressive collapse can be obtained by using Side Plate connections in steel frames.

차량 전복 방지를 위한 정적 출력 피드백 제어기 설계 (Design of Static Output Feedback Controllers for Rollover Prevention)

  • 임성진;오동호
    • 한국자동차공학회논문집
    • /
    • 제22권1호
    • /
    • pp.20-28
    • /
    • 2014
  • This paper presents static output feedback LQ and $H_{\infty}$ controllers for rollover prevention. Linear quadratic static output feedback controllers have been proposed for rollover prevention in such a way to minimize the lateral acceleration and the roll angle. Rollover prevention capability can be enhanced if $H_{\infty}$ controller is designed. To avoid full-state measurement for feedback requirement or sensitiveness of an observer to nonlinear model error, static output feedback is adopted. To design static output feedback controllers, Kosut's method is adopted because it is simple to calculate. Differential braking and active anti-roll bar are adopted as actuators that generate yaw and roll moments, respectively. The proposed method is shown to be effective in preventing rollover through the simulations on nonlinear multi-body dynamic simulation software, CarSim.

Structural identification and seismic performance of brick chimneys, Tokoname, Japan

  • Aoki, T.;Sabia, D.
    • Structural Engineering and Mechanics
    • /
    • 제21권5호
    • /
    • pp.553-570
    • /
    • 2005
  • Dynamic and static analyses of existing structures are very important to obtain reliable information relating to actual structural properties. For this purpose a series of material test, dynamic test and static collapse test of the existing two brick chimneys, in Tokoname, are carried out. From the material tests, Young's modulus and compressive strength of the brick used for these chimneys are estimated to be 3200 MPa and 7.5 MPa, respectively. The results of static collapse test of the existing two brick chimneys are discussed in this paper and composed with the results from FEA (Finite Element analysis). From the results of dynamic tests, the fundamental frequencies of Howa and Iwata brick chimneys are estimated to be about 2.69 Hz and 2.93 Hz, respectively. Their natural modes are identified by ARMAV (Autoregressive Moving Average Vectors) model. On the basis of the static and dynamic experimental tests, a numerical model has been prepared. According to the European code (Eurocode n. 8: "Design of structures for earthquake resistance") non-linear static (Pushover) analysis of the two chimneys is carried out and they seem to be vulnerable to earthquakes with 0.25 to 0.35 g.

Effects of Thoracic Mobility Exercise Program on Pain, Proprioception, and Static Balance Ability in Patients with non-Specific Chronic Low Back Pain

  • Donghwan Park;Kang-Seong Lee
    • Physical Therapy Rehabilitation Science
    • /
    • 제13권1호
    • /
    • pp.1-7
    • /
    • 2024
  • Objective: The objective of this study was to investigate the effect of the thoracic mobility exercise program on pain, proprioception, and static balance ability in patients with non-specific chronic low back pain. Design: Randomized controlled trial design. Methods: Thirty patients with non-specific chronic low back pain participated in this study. The participants were randomized into the thoracic mobility exercise group (n=15) and the lumbar stabilization exercise group (n=15). Both groups received traditional physical therapy for 30 minutes per session. In addition, the thoracic mobility exercise group and the lumbar stabilization exercise group each exercise 3 times a week for 6 weeks. All participants were measured visual analog scale, proprioception test, and static balance ability before and after the intervention. Results: After 6 weeks of interventions, the thoracic mobility exercise group showed greater improvement in visual analog scale, proprioception test, and static balance ability than the LSE group (p<0.05). Further, the thoracic mobility exercise group had significant Enhancements in all measured variables compared to the baselinetest (p<0.05). However, the lumbar stabilization exercise group had significant improvement only visual analog scale, and static balance ability compared to the baselinetest (p<0.05). Conclusions: Our investigation demonstrates that the thoracic mobility exercise is an effective intervention method for improving pain, proprioception, and static balance ability in patients with non-specific chronic low back pain.

원심모형 실험을 이용한 지반-말뚝 상호작용의 정적 및 동적 거동 평가 (Comparison of Lateral Pile Behavior under Static and Dynamic Loading by Centrifuge Tests)

  • 유민택;권선용
    • 한국지반공학회논문집
    • /
    • 제34권7호
    • /
    • pp.51-58
    • /
    • 2018
  • 본 연구에서는 하중 조건에 따른 지반-말뚝 상호작용 시스템의 거동 차이를 분석하기 위해 일련의 원심모형 실험을 수행하였다. 정적 하중 조건의 경우, 말뚝 직경의 50% 수준까지 변위제어를 통해 하중을 재하하였으며, 지진 하중 조건의 경우 0.1g~0.4g 수준으로 1Hz 정현파를 가진하였다. 실험 결과로부터 얻은 정적 및 동적 p-y 곡선을 API p-y 곡선과 비교한 결과, API p-y 곡선과 정적 하중조건에서의 실험 p-y 곡선은 최대 지반반력 값이 20% 이내의 오차를 보인 반면, 동적 하중 조건에서의 실험 p-y 곡선과는 최대 지반반력 값이 5배 이상 차이가 발생하였다. 이는 등가정적 해석에서 기존 API p-y 곡선을 적용할 경우 비선형 영역에서 지반 반력을 크게 과소평가하며 보수적 설계를 야기할 수 있음을 의미한다.

정적변위를 고려한 플랜트 구조물의 단자유도 폭발 해석 (Blast Analysis of Single Degree of Freedom Plant Structures Considering Static Displacement)

  • 이재균;이승훈;김한수
    • 한국전산구조공학회논문집
    • /
    • 제35권5호
    • /
    • pp.317-324
    • /
    • 2022
  • 본 논문에서는 등가 단자유도를 이용하여 구조부재의 정적변위를 고려하는 해석기법을 제시하였다. 기존의 단자유도 비선형 동적 해석 알고리듬을 구조부재의 초기정적변위의 영향을 고려할 수 있도록 개선하였다. 가정된 폭발하중 지속시간과 부재의 고유주기 비에 따라 정적변위가 최대응답에 미치는 영향의 차이와 폭발하중의 방향과 초기변위의 방향에 따른 차이를 확인하였다. 이에 따라 기존의 응답 차트를 정적변위를 고려할 수 있도록 폭발하중의 형태에 따라 각각 제시하였다. 설계 예제를 정적변위가 고려된 응답 차트에 적용하여 부재의 최대 변위를 비교 및 분석하였다. 본 연구의 결과를 통해 초기 정적변위를 고려한 구조부재의 최대응답을 쉽게 산정할 수 있으며 본 연구에서 제시한 응답 차트는 플랜트 또는 군사시설물의 내폭 설계에 활용될 수 있다.

등가정적해석법에 의한 수계 파이프 시스템의 내진설계 (The Seismic Design of Water Extinguishing Piping Systems for Equivalent Static Analysis Method)

  • 이동명
    • 한국화재소방학회논문지
    • /
    • 제26권3호
    • /
    • pp.100-105
    • /
    • 2012
  • 본 연구에서는 수계소화설비 가압송수장치의 파이프라인에 대한 내진설계를 수행하였다. 내진해석에 필요한 내진설계용 스펙트럼에 대응하는 인공지진 진동파형을 작성하였고, 작성된 인공지진 진동에 대한 응답 스펙트럼 가속도를 결정하여 등가정적하중을 결정하였다. 내진설계를 위한 공학적 기반을 구축하였으며, 수계 및 가스계 파이프 시스템의 내진설계를 위한 등가정적해석법을 제시하였다. 또한 본 연구의 결과로부터 수계설비의 파이프라인뿐만 아니라 소방설비의 내진설계 및 성능평가에 응용할 수 있는 기틀을 마련하였다. 향후 진도규모 및 지반종류에 따른 추가적인 연구가 수행된다면 소방시스템의 신뢰성 향상과 안전성 제고, 성능위주설계가 이루어질 수 있을 것으로 본다.

연속시간 T-S 퍼지 시스템에 대한 정적 출력궤환 제어 (Static Output Feedback Control for Continuous T-S Fuzzy Systems)

  • 정은태
    • 제어로봇시스템학회논문지
    • /
    • 제21권6호
    • /
    • pp.560-564
    • /
    • 2015
  • This paper presents a design method of a static output feedback controller for continuous T-S fuzzy systems via parallel distributed compensation (PDC). The existence condition of a set of static output feedback gains is represented in terms of linear matrix inequalities (LMIs). The sufficient condition presented here does not need any transformation matrices and equality constraints and is less conservative than the previous results seen in [20].