• Title/Summary/Keyword: static/dynamic simulation

Search Result 645, Processing Time 0.025 seconds

Simulation Study on the Safety of a Fastening Device of Agricultural By-product Collector (동역학 시뮬레이션을 통한 농업부산물 수집기 체결장치의 안전성 분석)

  • Jeong-Hun Kim;Seok-Joon Hwang;Ju-Seok Nam
    • Journal of Drive and Control
    • /
    • v.20 no.3
    • /
    • pp.42-49
    • /
    • 2023
  • In this study, the safety of fastening device for the agricultural by-product collector was evaluated according to the driving ground conditions by deriving the stress, static safety factor, and fatigue life using dynamic simulation. A 3D modeling of agricultural by-product collector was carried out, and simulation model was developed by applying the material properties. As a result of dynamic simulation, the magnitude of the maximum stress generated in the fastening device was the highest when driving on the flat off-road, followed by sloped pave-road and flat pave-road. Static safety factor and fatigue life were the highest when driving on the flat pave-road, followed by sloped pave-road and flat off-road. The safety of fastening device was confirmed that static safety factor was more than 1.0 and service life exceeded 9 years in all driving ground conditions.

Shift Control Strategy for Electric Controlled CVT Vehicle (전자 제어 CVT 차량의 변속제어전략)

  • 김동우;김현수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.3
    • /
    • pp.85-97
    • /
    • 2000
  • In this paper, static and dynamic shift control stategies of CVT speed ratio are suggested. For the static shift control, in order to operate engine on the optimal operating region, a fuzzy control logic is used. In the fuzzy logic, S- factor that is defined as a degree of sportiness is introduced. Simulation results show that the static shift control strategy based on the fuzzy logic selects the optimal operating point automatically between the economy and the sporty mode corresponding to the driver's desire and the driving condition. For the dynamic shift control strategy, a shift speed map is suggested which determines the shift sped as fast or slow based on Δi, the difference between the desired speed ratio id and the actual speed ratio i, and throttle opening. It is seen from the simulation results that the CVT shift speed is determined by the dynamic shift control strategy to provide appropriate performance and comfort for the driver's demand and driving condition. Additionally, experiments are performed to investigate the dynamic performance of the shift speed for the lift foot up. From the experimental results, it is found that improved shift feeling can be obtained by the dynamic shift control strategy when lift foot up occurs.

  • PDF

A Study on the Dynamic Simulation of High Speed Current Collection System (고속 집전계의 동적 수치모의해석 프로그램 연구)

  • Hur, S.;Kyung, J.H.;Song, D.H.;Kim, J.S.;Cho, Y.H.
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.1
    • /
    • pp.10-17
    • /
    • 2002
  • In this study, we have developed the static and dynamic simulation program of a high speed current collection system. The catenary wire is modeled to discrete masses connected by massless strings and the pantograph is replaced with 3 d.o.f equivalent models that are composed of masses, springs and dampers. We derived partial differential equations of motion from the equivalent model and developed the simulation program. Then, we calculated the static equilibrium state of the overhead catenary and the dynamic behaviors of the high speed current collection system. The analysis results were compared with the results of GASENDO software developed at RTRI in Japan.

Simulation and Parameter Identification of Induction Machine in Load Modeling based on the Static Circuit Analysis (정태회로해석에 의한 전력부하로서의 유도전동기 시뮬레이션 및 파라메터 식별)

  • Lee, Bong-Yong;Shim, Keon-Bo;Ko, Tae-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.370-374
    • /
    • 1991
  • This paper presents a static circuit model for static ant dynamic simulation of induction motors and identification of motor parameters. Instead of usual T-circuits, equivalent ${\pi}$-circuit has been proposed so that power Inputs into motor terminals can very easily calculated with very well known load flow method. It has been shown that, with wide range variation of applied voltage and frequency, successful static simulations can be performed and further the proposed static model can be used to simulate dynamic characteristics. Finally it is shown also that motor parameters can easily be identified based on the proposed static circuit.

  • PDF

Study of Static/Dynamic Load Model by measurement (실측에 의한 Static/Dynamic 부하모델 개발 연구)

  • Choi, H.K.;Moon, Y.H.;Yoon, J.Y.;Jeon, J.H.;Choo, J.B.;Yun, Y.B.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.58-60
    • /
    • 2000
  • This paper presents the modeling methods to analyze the static and dynamic performances for practical power system loads using field measurement data. Also, it is included that the several modeling techniques using EMTDC program and field measuring method for real static dynamic loads. As a result of this study, through the comparisons between simulation results and measurement data, typical parameters of static and dynamic loads according to the variation of system voltage and frequency are given.

  • PDF

Dynamic Model Development and Simulation of Crawler Type Excavator (크롤러형 굴삭기의 동역학적 모델 개발 및 시뮬레이션)

  • Kwon, Soon-Ki
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.642-651
    • /
    • 2009
  • The history of excavator design is not long enough which still causes most of the design considerations to be focused on static analysis or simple functional improvement based on static analysis. However, the real forces experiencing on each component of excavator are highly transient and impulsive. Therefore, the prediction and the evaluation of the movement of the excavator by dynamic load in the early design stage through the dynamic transient analysis of the excavator and ensuring of design technique plays an importance role to reduce development-cost, shorten product-deliver, decrease vehicle-weight and optimize the system design. In this paper, Commercial software DADS and ANSYS help to develop the track model of the crawler type excavator, and to evaluate the performance and the dynamic characteristics of excavator with various simulations. For that reason, the track of crawler type excavator is modelled with DADS Track Vehicle Superelement, and the reaction forces on the track rollers were predicted through the driving simulation. Also, the upper frame and cabin vibration characteristics, at the low RPM idle state, were evaluated with engine rigid body modelling. And flexibility body effects were considered to determine the more accurate joint reaction forces and accelerations under the upper frame swing motion.

  • PDF

A new Dynamic Switching Function for Output feedback Variable Structure Control (출력궤환가변구조제어를 위한 동적스위칭함수의 제안과 응용)

  • 이기상;송명현;조상호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.7
    • /
    • pp.706-717
    • /
    • 1991
  • In order to remove the assumption of full state availability which is one of the major difficulties with the practical realization of variable structure control systems,a new switching function with a dynamic structure is proposed. And the control performances of the output feedback variable structure control systems with the dynamic switching function are evaluated through simulation studies. The proposed dynamic switching function is driven by small number of measured output and input variables while conventional static switching function requires full state information. Therefore, the proposition of the dynamic swiching function makes practical implementation of output feedback variable structure control scheme possible for the systems with unmeasurable state variables, high order systems and large scale systems that the conventional variable structure control schemes with static switching function cannot be applied. In the variable structure control systems with the dynamic switching function, desired control performance can be guaranteed by proper choice of design parameters such as poles of switching function dynamic equation and switching control gains even though small number of measured output and input variables are provided as shown in simulation resuls.

  • PDF

An Effective Frequency Allocation Plan for Symmetric 10MDSL Systems (양방향 10MDSL을 위한 VDSL 시스템의 주파수할당 계획)

  • Kil, Jung-Su;Kwon, Ho-Yeol
    • Journal of Industrial Technology
    • /
    • v.22 no.B
    • /
    • pp.169-173
    • /
    • 2002
  • In this paper, we discussed an effective VDSL frequency plan for symmetric 10MDSL service. The frequency plan 998 and plan 997 for asymmetric VDSL services have been not optimally designed for 10MDSL services. To obtain the reaches and data rates of 10MDSL, we proposed two frequency allocation schemes : Static method and dynamic method. We can select frequency bands with their fixed boundaries in static method while with their variable boundaries in dynamic method. To show the effectiveness of our proposed methods, we performed some simulations about plan 997 and plan 998, new static method, and new dynamic method. According to the simulation results, the proposed dynamic method can provide the best data rates and reaches for 10 Mbps symmetric VDSL services.

  • PDF

Damage Identification Technique for Bridges Using Static and Dynamic Response (정적 및 동적 응답을 이용한 교량의 손상도 추정 기법)

  • Park Woo-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.119-126
    • /
    • 2005
  • Load bearing structural members in a wide variety of applications accumulate damage over their service life. From a standpoint of both safety and performance, it is desirable to monitor the occurrence, location, and extent of such damage. Structures require complicated element models with a number of degrees of freedom in structural analysis. During experiment much effort and cost is needed for measuring structural parameters. The sparseness and errors of measured data have to be considered during the parameter estimation Of Structures. In this paper we introduces damage identification algorithm by a system identification(S.I) using static and dynamic response. To study the behaviour of the estimators in noisy environment Using Monte Carlo simulation and a data measured perturbation scheme is adopted to investigate the influence of measurement errors on identification results. The assessment result by static and dynamic response were compared, and the efficiency and applicabilities of the proposed algorithm are demonstrated through simulated static and dynamic responses of a truss bridge. The assessment results by each method were compared and we could observe that the 5.1 method is superior to the other conventional methods.

The study on the Analysis of Useful Daylight Illuminance in rural standard house model - By Dynamic Daylight Simulation Using Weather Data - (농어촌주택 표준설계의 유용조도 분석에 관한 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Yun, Young Il;Song, Jeong Suk;Lee, Hyo Won
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.47-55
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the Rural standard house models design process, because of lack of previous studies on elderly-light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.