• Title/Summary/Keyword: startup time

Search Result 145, Processing Time 0.023 seconds

Effective Backup and Real-Time Replication Techniques for HSS System in All-IP Mobile Networks (All-IP 이동 통신망에서 HSS 시스템의 효과적인 백업과 실시간 이중화 기법)

  • Park, Seong-Jin;Park, Hyung-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.4
    • /
    • pp.795-804
    • /
    • 2009
  • An HSS(Home Subscriber Server) system requires a main-memory database on main-memory unit for the real-tine management of the subscriber information in the mobile communication service, in that the system controls not only basic data for handling calls of users, but also additional service data related to user authentication and operational data. Nonetheless, HSS-DBS system, requiring the reliability and stability, need more secure data store method and a back-up technique because the system have a long startup time and the big problem on the failures of main-memory. This paper proposes an efficient back-up replication technique, on the basis of enhancing the stability and performance of HSS system. The proposed shadowing back-up technique adopting the delayed recovery process, can help minimize the real-time back-up overloads by location registration, while the proposed backup replication method enables more stable system operations with replicating the data to remote server in real time.

Transformer-Reuse Reconfigurable Synchronous Boost Converter with 20 mV MPPT-Input, 88% Efficiency, and 37 mW Maximum Output Power

  • Im, Jong-Pil;Moon, Seung-Eon;Lyuh, Chun-Gi
    • ETRI Journal
    • /
    • v.38 no.4
    • /
    • pp.654-664
    • /
    • 2016
  • This paper presents a transformer-based reconfigurable synchronous boost converter. The lowest maximum power point tracking (MPPT)-input voltage and peak efficiency of the proposed boost converter, 20 mV and 88%, respectively, were achieved using a reconfigurable synchronous structure, static power loss minimization design, and efficiency boost mode change (EBMC) method. The proposed reconfigurable synchronous structure for high efficiency enables both a transformer-based self-startup mode (TSM) and an inductor-based MPPT mode (IMM) with a power PMOS switch instead of a diode. In addition, a static power loss minimization design, which was developed to reduce the leakage current of the native switch and quiescent current of the control blocks, enables a low input operation voltage. Furthermore, the proposed EBMC method is able to change the TSM into IMM with no additional time or energy loss. A prototype chip was implemented using a $0.18-{\mu}m$ CMOS process, and operates within an input voltage range of 9 mV to 1 V, and an output voltage range of 1 V to 3.3 V, and provides a maximum output power of 37 mW.

Networked Intelligent Motor-Control Systems Using LonWorks Fieldbus

  • Hong, Won-Pyo
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.365-370
    • /
    • 2004
  • The integration of intelligent devices, devices-level networks, and software into motor control systems can deliver improved diagnostics, fast warnings for increased system reliability, design flexibility, and simplified wiring. Remote access to motor-control information also affords an opportunity for reduced exposure to hazardous voltage and improved personnel safety during startup and trouble-shooting. This paper presents LonWorks fieldbus networked intelligent induction control system architecture. Experimental bed system with two inverter motor driving system for controlling 1.5kW induction motor is configured for LonWorks networked intelligent motor control. In recent years, MCCs have evolved to include component technologies, such as variable-speed drives, solid-state starters, and electronic overload relays. Integration was accomplished through hardwiring to a programmable logic controller (PLC) or distributed control system (DCS). Devicelevel communication networks brought new possibilities for advanced monitoring, control and diagnostics. This LonWorks network offered the opportunity for greatly simplified wiring, eliminating the bundles of control interwiring and corresponding complex interwiring diagrams. An intelligent MCC connected in device level control network proves users with significant new information for preventing or minimizing downtime. This information includes warnings of abnormal operation, identification of trip causes, automated logging of events, and electronic documentation. In order to show the application of the multi-motors control system, the prototype control system is implemented. This paper is the first step to drive multi-motors with serial communication which can satisfy the real time operation using LonWorks network.

  • PDF

Delayed Operation Characteristics of Power Shuttle According to Hydraulic Oil Temperature in the Hydraulic Circuit of Agricultural Tractor

  • Park, Yoon-Na;Kim, Dae-Cheol;Park, Seung-Je
    • Journal of Biosystems Engineering
    • /
    • v.40 no.2
    • /
    • pp.95-101
    • /
    • 2015
  • Purpose: During the start-up period, the response time of a hydraulic system increases in the winter because of the increased oil viscosity caused by the cold weather. The problems of delayed tractor starting and excessive wear of the clutch disk occur for these reasons. Therefore, this study develops an analysis model using the commercial hydraulic analysis program AMESim to examine the characteristics of delays in power shuttle starting at different oil temperatures. Methods: In the experiment, a tractor was stationary on a flat surface with the engine running at a constant speed of 1,080 rpm. The forward lever was then pressed to activate the power shuttle at three different oil temperatures, and the pressure changes were measured. The pressure on the forward clutch control valve was measured by a pressure gauge installed on the hydraulic line supplied to the transmission from the main valve. An analysis model was also developed and verified with actual tests. Results: The trend of the simulated pressures of the power shuttle is similar to that of the measured pressures, and a constant modulation period was observed in both the simulation and test results. However, the difference found between the simulation and test results was the initial pressure required to overcome the initial force of the clutch spring. Conclusions: This study also examines the characteristics of the delayed startup of the power shuttle at different oil temperatures through simulations.

Real-time steady state identification technology of a heat pump system to develop fault detection and diagnosis system (열펌프의 고장감지 및 진단시스템 구축을 위한 실시간 정상상태 진단기법 개발)

  • Kim, Min-Sung;Yoon, Seok-Ho;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.282-287
    • /
    • 2008
  • Identification of steady-state is the first step in developing a fault detection and diagnosis (FDD) system. In a complete FDD system, the steady-state detector will be included as a module in a self-learning algorithm which enables the working system's reference model to "tune" itself to its particular installation. In this study, a steady-state detector of a residential air conditioner based on moving windows was designed. Seven representing measurements were selected as key features for steady-state detection. The optimized moving window size and the feature thresholds was suggested through startup transient test and no-fault steady-state test. Performance of the steady-state detector was verified during indoor load change test. From the research, the general methodology to design a moving window steady-state detector was provided for vapor compression applications.

  • PDF

Analysis and Design of a Separate Sampling Adaptive PID Algorithm for Digital DC-DC Converters

  • Chang, Changyuan;Zhao, Xin;Xu, Chunxue;Li, Yuanye;Wu, Cheng'en
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2212-2220
    • /
    • 2016
  • Based on the conventional PID algorithm and the adaptive PID (AD-PID) algorithm, a separate sampling adaptive PID (SSA-PID) algorithm is proposed to improve the transient response of digitally controlled DC-DC converters. The SSA-PID algorithm, which can be divided into an oversampled adaptive P (AD-P) control and an adaptive ID (AD-ID) control, adopts a higher sampling frequency for AD-P control and a conventional sampling frequency for AD-ID control. In addition, it can also adaptively adjust the PID parameters (i.e. $K_p$, $K_i$ and $K_d$) based on the system state. Simulation results show that the proposed algorithm has better line transient and load transient responses than the conventional PID and AD-PID algorithms. Compared with the conventional PID and AD-PID algorithms, the experimental results based on a FPGA indicate that the recovery time of the SSA-PID algorithm is reduced by 80% and 67% separately, and that overshoot is decreased by 33% and 12% for a 700mA load step. Moreover, the SSA-PID algorithm can achieve zero overshoot during startup.

An Overview of Seabed Storage Methods for Pipelines and Other Oil and Gas Equipment

  • Fatah, M.C.;Mills, A.;Darwin, A.;Selman, C.
    • Corrosion Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.76-84
    • /
    • 2017
  • In the construction of subsea oil and gas developments, it is increasingly common that subsea oil and gas equipment will be installed in subsea well before final hookup and production. Installation of wellheads, subsea hardware, pipelines, and surface facilities (platforms, FPSO, FLNG, connected terminals, or gas plants) are increasingly driven by independent cost and vessel availability schedules; this gives rise to requirements that the subsea facilities must be stored in the seabed for a specific time. In addition, schedule delays, particularly in the installation or startup of the connected platform, FPSO, FLNG, or onshore plant may cause unexpected extensions of the intended storage period. Currently, there are two methods commonly used for storage subsea facilities in the seabed: dry parking and wet parking. Each method has its own risks, challenges, and implications for the facility life and its integrity. The corrosion management and preservation method selection is a crucial factor to be considered in choosing the appropriate storage method and achieving a successful seabed storage. An overview of those factors is presented, along with a discussion on the internal corrosion threats and assessments.

Culture and mycelim-mat formation characteristics of mutant strains by gamma-ray treatment (감마선 처리에 의한 변이주의 배양 및 균막형성 특성)

  • Kim, Hyoun-Suk;Oh, Chan-Jin;Jeong, Kwang-Ju;Choi, Moon-Hee;Shin, Hyun-Jae;Oh, Deuk-Sil
    • Journal of Mushroom
    • /
    • v.18 no.4
    • /
    • pp.393-397
    • /
    • 2020
  • Mycelium composites and leathers have versatile material properties based on their composition and manufacturing process. To prepare mycelium mat for the production of mushroom leather, several strains were mutated by gamma rays. Some mutant strains, including Lentinula edodes, Ganoderma lucidium, and Schizophyllum commune showed good hyphae growth rate and density on saw-dust media. Irradiation power (Gy), time, and height from the radiation source to the sample were examined. Based on the preliminary data obtained in this study, comprehensive research should be conducted to explore the optimal strains and culture conditions for mycelium-based leather production.

Operating Characteristics of a Main Oxidizer Shut-off Valve According to Operating Times (작동 횟수에 따른 연소기 산화제 개폐밸브 작동 특성)

  • Hong, Moongeun
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.5
    • /
    • pp.77-83
    • /
    • 2020
  • The operating characteristics of a main oxidizer shut-off valve have been examined by life-cycle tests in which the valve operates as many times as is required at room and cryogenic temperatures. It is shown that there is no significant change of the operating characteristics in the course of the life-cycle tests. The critical pressures and principal forces, which represent the operating characteristics, differ at each operating time by less than about 3%. These qualified operating characteristics of the valve are expected to play an indispensible role in the stable startup and shutdown of a liquid rocket engine.

Analysis of Factors Influencing Entrepreneurial Performance at the University Level for Becoming Entrepreneurial Universities (기업가형 대학(Entrepreneurial University)을 위한 대학의 창업 성과 영향요인 분석)

  • Lim, Hanryeo;Hon, Sungpyo
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.15 no.2
    • /
    • pp.19-32
    • /
    • 2020
  • The purpose of this study was to investigate the influence factors of the university level centering on the entrepreneurial performance of the university students and full-time faculties in the situation of increasing interest in entrepreneurial university. In order to achieve the purpose of the study, a panel data was established from 2015 to 2018 on the basis of the university notification data. The panel data included universities with data on the number of university students and full-time faculty founders for at least two years. Through this, four year data from 154 universities were used for analysis. As an analysis method, frequency analysis and descriptive statistics were conducted to understand the characteristics of the university. Since then, panel negative binomial regression analysis has been conducted in consideration of the longitudinal features and distribution of the data. Also, based on the Hausman test results, the results were interpreted based on random effect model. The results of this study are as follows. First, as a result of the analysis of the entrepreneurial performance and the change trend of the domestic university from 2015 to 2018, the entrepreneurial performance of the university has been steadily increasing in the last four years, and the increase in the number of university student entrepreneurs was relatively higher than the full-time faculties. Second, economic and educational approaches need to be combined to promote university students' start-ups. The university factors that promote the start-up of university students were found to be scholarships, start-up grants, startup lectures, and startup clubs. Third, the openness and regional characteristics of the univeristy can promote the establishment of university students. Fourth, the establishment of a research environment and support for start-ups for full-time faculty members can enhance their start-up performance. The university factors that promote the start-up of full-time faculty were research funds and staffes who support start-up. The conclusions drawn from these findings are as follows. First, overall efforts are needed to develop into an entrepreneurial university. Second, in order to change into an entrepreneurial university, direct support for entrepreneurship is needed. Third, as an entrepreneurial university, it is necessary to find a way to bridge the gap by university according to region and size. Fourth, it is necessary to reinforce the support for linking the research results of universities to start-ups. Fifth, it is necessary to improve the atmosphere for full-time faculty members to be entrepreneur.