Nano-Wear and Friction of Magnetic Recording Hard Disk by Contact Start/Stop Test

  • Kim, Woo Seok;Hwang, Pyung;Kim, Jang-Kyo
    • KSTLE International Journal
    • /
    • v.1 no.1
    • /
    • pp.12-20
    • /
    • 2000
  • Nano-wear and friction of carbon overcoated laser-textured and mechanically-textured computer hard disk were characterised after contact start/stop (CSS) wear test. Various analytical and mechanical testing techniques were employed to study the changes in topography, roughness, chemical elements, mechanical properties and friction characteristics of the coating arising from the contact start/stop wear test These techniques include: the atomic force microscopy (AFM), the continuous nano-indentation test, the nano-scratch test, the time-of-flight secondary ion mass spectroscopy (TOF-SIMS) and the auger electron spectroscopy (AES). It was shown that the surface roughness of the laser-textured (LT) bump and mechanically textured (MT) Bone was reduced approximately am and 7nm, respectively, after the CSS wear test. The elastic modulus and hardness values increased after the CSS test, indicating straining hardening of the top coating layer, A critical load was also identified fer adhesion failure between the magnetic layer and the Ni-P layer, The TOF-SIMS analysis also revealed some reduction in the intensity of C and $C_2$$F_59$, confirming the wear of lubricant elements on the coating surface.

  • PDF

Development of Start·Stop Control System at Water Turbine Generator for Tidal Power Plant (조력발전소를 위한 수차발전기의 기동·정지 제어시스템 개발)

  • Cho, Byong-Og;Park, Chul-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.106-112
    • /
    • 2014
  • Recently, tidal power generation has gained much attention. South Korea's tidal power generation systems were imported from abroad by turnkey type and have being operated. Therefore, for efficient operation and technological independence of a tidal power system, development of core technology is required. This paper deals with the start stop control system of water turbine generator in the tidal power plant, as one of our development project results. Using the SCADA system, the status and operations of water turbine generator in the tidal power plant, as well as simulation for calculation of maximum power were carried out. A small model type of start stop control device was also developed. In addition, the control system in Sihwa tidal power plant was modeled, and the results obtained by the dynamic simulation were given in graphics by 2D simulator.

Nano-tribology of laser textured hard disk by contact start/stop test (CSS test에 의한 레이저 텍스쳐 디스크의 나노-트라이볼로지)

  • Kim, Woo-Seok;Hwang, Pyung;Kim, Jang-Kyo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1589-1595
    • /
    • 2000
  • 레이저 텍스쳐와 미케니칼 텍스쳐 컴퓨터 하드디스크의 마찰과 마코 매카니즘이 Contact Start/Stop test 실행후의 특성들에 대해 연구되었다. 다양한 분석적이고 기계적인 테스트 기술들이 이용되었다. 형상, 조도, 화학적 조성, 기계적 성질, CSS 로부터 기인된 코팅의 마찰특성들에 대해 그 변화들을 조사하였다. 즉, AFM(Atomic Force Microscopy), Nano-Indentation, Nano-Scratch, TOF-SIMS(Time of Flight Secondary Ion Mass Spectroscopy), AES(Auger Electronic Spectroscopy)등이 이 연구에 적용되었다. 레이저 텍스쳐 범프의 표면조도와 미케니칼 텍스쳐 지역의 표면조도는 각각 대략적으로 4nm 와 7nm 감소되었다. 탄성계수와 경도값은 CSS test후에 증가하였고 가장 바깥쪽의 코팅층의 변형강화가 생겨났다. 자성층과 Ni-P 층 사이에 점착성의 문제가 확인되었다. TOF-SIMS 분석은 C 와 $C_2F_5$의 세기에 있어서 감소를 드러냈고 이것은 코팅 표면에 윤활제 요소의 마모를 확실시 할수 있는 결과로 나타났다.

  • PDF

Investigation of Particle Generation in a Hard Disk Drive During the Start/Stop Period (구동 및 정지시 하드 디스크 드라이브 내 입자 발생 특성에 관한 실험적 연구)

  • Park, Hee-Sung;Yoo, Yong-cheol;Bae, Gwi-Nam;Hwang, Jung-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.6
    • /
    • pp.744-752
    • /
    • 1999
  • Particle contamination in a hard disk drive has been recognized as an important issue because particles can significantly affect the reliability of the drive. In this study, characteristics of the particle generation in a hard disk drive during the start/stop period were investigated. The number of particles generated in the drive was measured at 5 locations by using condensation nucleus counters(CNC) with sampling probes. It was found that most of particles were generated whenever the drive started or stopped. The number of particles detected by the condensation nucleus counter depended on sampling parameters including sampling location, shape of sampling probe, and sampling velocity.

Longitudinal Tension Control at Start and Stop in a Multi-span Continuous Process System (변속시의 멀티 스팬 연속 공정 시스템의 장력제어)

  • 신기현;권순오
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.584-589
    • /
    • 1994
  • A time-varying nonlinear mathematical model was derived to consider the effect of change in roll radius on tension varation during winding and unwinding. A variable-gain PID controller was designed for tension control at start and stop in a multi-span continuous process system. The controller gains are updated at every control loop as roll radii continuously change. Computer simulation was carried out by using the mathematical model and the controller developed for a typical operating condition including acceleration and deceleration. When the variable-gain PID controller was used, the tension control performance was improved compared with that of existing control method during start-up and stop.

  • PDF

Evaluations on Driver's Sensibility Changes by Sudden Start and Sudden Stop Conditions in Driving Simulator (자동차 시뮬레이터에서의 급출발 및 급제동에 따른 운전자 감성 평가)

  • 전효정;민병찬;성은정;김철중
    • Science of Emotion and Sensibility
    • /
    • v.5 no.4
    • /
    • pp.51-57
    • /
    • 2002
  • The purpose of the study was to measure and compare driver's psychophysiological responses in different driving conditions through driving simulator. Twelve male adults(more than 1 year of driving experience) were assigned to four different driving conditions, such as normal speed(70㎞/h), sudden start(0㎞/h→70㎞/h), and sudden stop(70㎞/h→0㎞/h), and their simulator sickness, subjective pleasantness and arousal, EEG, ECG, skin temperature, and GSR were measured. Subjective and physiological evaluations were executed before and after driving in each condition. The results showed that subjective pleasantness and arousal increased in sudden stop and sudden start conditions, relative to stop and normal speed conditions. As the central nervous responses, beta wave increased and alpha wave decreased in sudden stop and sudden start conditions, relative to stop and normal speed conditions. With regard to the autonomic responses, heart rate and GSR increased, while skin temperature decreased in sudden stop and sudden start conditions, which means an activation of sympathetic nervous system. The results suggested that based upon observation of the distinctive psychophysiological changes by driving conditions, it is possible to evaluate the human sensibility in dynamic environment.

  • PDF

Time-to-Digital Converter Using Synchronized Clock with Start and Stop Signals (시작신호 및 멈춤신호와 동기화된 클록을 사용하는 시간-디지털 변환기)

  • Choi, Jin-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.5
    • /
    • pp.893-898
    • /
    • 2017
  • A TDC(Time-to-Digital Converter) of counter-type is designed by $0.18{\mu}mCMOS$process and the supply voltage is 1.5 volts. The converted error of maximum $T_{CK}$ is occurred by the time difference between the start signal and the clock when the period of clock is $T_{CK}$ in the conventional TDC. And the converted error of -$T_{CK}$ is occurred by the time difference between the stop signal and the clock. However in order to compensate the disadvantage of the conventional TDC the clock is generated within the TDC circuit and the clock is synchronized with the start and stop signals. In the designed TDC circuit the conversion error is not occurred by the difference between the start signal and the click and the magnitude of conversion error is reduced (1/2)$T_{CK}$ by the time difference between the stop signal and the clock.

A Study on TRANSYT Model-embedded Parameters (TRANSYT 모델의 내재 모개변수에 관한 연구)

  • 도철웅
    • Journal of Korean Society of Transportation
    • /
    • v.6 no.1
    • /
    • pp.55-64
    • /
    • 1988
  • Prior to using any computer model, the program-embedded palameters showing significant differences from real world should be calibrated. This is especially true when the model is expected to be used fro various roadway and traffic condition. The calibration of TRANSYT model was conducted for the parameters of start-up delay, and lag, stop penalty(K), platoon dispersion factor, and saturation flow rate. The values of the parameters were obtained by theoretical methods from actual field measurements for discharging and arrival pattern. The sites elected for the study was an intersection of Dongil-Ro and Hwarang-Ro, and a 334 meter downstrean section from the intersection stop line on westbound Hwarang-Ro. The study results showed that the start-up delay was 2.6 sec, end lag was 1.0 sec, saturation flow rate was 2287 pcphgpl, platoon dispersion factor was 0.2-03, and stop penalty(K) was 32. However, since these parameters re apt to depend on traffic and roadway condition, it is doubtful whether the obtained values will be applicable to the area-wide situation other than this particular site.

  • PDF

Consideration of Pressure-Rise and Water Hammer for Pipe System in Relation to Start-Up and Sudden Stop of the Pump (펌프 기동 및 정지에 따른 배관 압력상승과 수격작용 영향 고찰)

  • Heo, Min Woong;Min, Ji Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.13 no.1
    • /
    • pp.69-74
    • /
    • 2017
  • In the fire protection system or fire fighting water supply system, the jockey pump is generally installed for the prevention of the pressure decrease of pipes, the frequent driving of the fire pump and protection the pipes from the water hammer. In this paper, the pressure-rise in fire fighting water distribution pipes in condition of pipe pressurization by the surge tank at the start-up and the sudden-stop of the fire pump without additional installation of jockey pump is considered by using simple formula calculations and the evaluation of water hammer occurrence in condition of pipe pressurization by the surge tank is included. As a result, the pressure-rise of pipes is less than the pipe design pressure at the condition of pump's start-up and sudden stop, and the possibility of water hammer occurrence is remarkably low due to pressurization of the pipes by the surge tank.

Automobile Power Seat Using Motor Current Profile Control Technology (모터 전류 형상 제어 기술을 적용한 차량용 전동 시트)

  • Chung, Myung-Jin
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.224-229
    • /
    • 2019
  • Seat of automobile is required to support the comfort to driver and passenger during the driving. The control method of the seat position is changed from manual type to power type, which means using the motor to increase the comfort of the driver. By using the motor, several problems, such as vibration, noise, and over-current, appeared. These problems can be reduced through the control of seat motor. In this study, a control technology of four control variables, which determine profile of the input voltage applying to the seat motor, is proposed to generate the current profile having soft-start and soft-stop. The current flowing through the coil by input voltage is described by mathematical modeling of power seat. It is confirmed that optimized current profile having soft-start and soft-stop can be generated from simulation using the mathematical model.