• Title/Summary/Keyword: standby unit

Search Result 43, Processing Time 0.023 seconds

Paper Duplication Method Supported by Task (태스크 기반 이중화 방안)

  • Lee, Jong-Chan;Park, Sang-Joon;Kang, Kwon-Il
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.1C
    • /
    • pp.103-111
    • /
    • 2002
  • In RNC of IMT-2000, main control processors such as ASP, ACP and OMP are responsible for call control function, and the high reliability and real-time property should be provided for it. So, the study of real-time fault-tolerant for it is needed. In this paper, we proposes an Task based duplication method, in which Tasks in active side operated on message unit and send the updated data to standby side after operation, log in the message to standby side for recovery during take-over. This scheme decreases the dual down and the complexity of synchronization procedure, and performs the synchronization more exactly because Tasks control the synchronization of system. This paper also proposes the fault detection and the fault handing method for effective implementation of Task based duplication. This scheme focus on increasing the fault detection rate and intercepting originally that fault data is send to standby side.

A Low-Power Single Chip Li-Ion Battery Protection IC

  • Lee, Seunghyeong;Jeong, Yongjae;Song, Yungwi;Kim, Jongsun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.4
    • /
    • pp.445-453
    • /
    • 2015
  • A fully integrated cost-effective and low-power single chip Lithium-Ion (Li-Ion) battery protection IC (BPIC) for portable devices is presented. The control unit of the battery protection system and the MOSFET switches are integrated in a single package to protect the battery from over-charge, over-discharge, and over-current. The proposed BPIC enters into low-power standby mode when the battery becomes over-discharged. A new auto release function (ARF) is adopted to release the BPIC from standby mode and safely return it to normal operation mode. A new delay shorten mode (DSM) is also proposed to reduce the test time without increasing pin counts. The BPIC implemented in a $0.18-{\mu}m$ CMOS process occupies an area of $750{\mu}m{\times}610{\mu}m$. With DSM enabled, the measured test time is dramatically reduced from 56.82 s to 0.15 s. The BPIC chip consumes $3{\mu}A$ under normal operating conditions and $0.45{\mu}A$ under standby mode.

Application Study of Condition Monitoring Technology for Emergency Diesel Generator at Nuclear Power Plant (원자력발전소 비상디젤발전기 상태감시 기술 적용 연구)

  • Choi, K.H.;Park, J.H.;Park, J.E.;Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.13 no.1
    • /
    • pp.53-58
    • /
    • 2009
  • The emergency diesel generator(EDG) of the nuclear power plant is designed to supply the power to the nuclear reactor on Station Black Out(SBO) condition. The operation reliability of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to monitor and analysis the condition of diesel generator. For this purpose, we have developing the technologies of condition monitoring for the wolsong unit 3&4 standby diesel generator including diesel engine performance. In this paper, technologies of condition monitoring for the wolsong standby diesel generator are described about three step. First is for selection of operating parameter for monitoring. Second is for technologies of online condition monitoring, Third is for monitoring of engine performance.

  • PDF

ICT based Wireless Power Transmission System Development (ICT 기반의 무선전력전송 시스템 개발)

  • Lee, Jong-Hee;Bang, Junho;Chun, Hyun-Jun;Seo, Beom-Geun;Ryu, In-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.67-73
    • /
    • 2016
  • Recently, wireless power transmission has attracted much interest and is the subject of much research in industry and academia. As its name implies, it is a technology which involves transferring power without wires. This paper presents the design of an ICT-based wireless power transmission system. The proposed system consists of a wireless transceiver unit and high-efficiency coil unit, which can increase both the transmission efficiency and the effective power distance. In particular, the wireless transceiver unit was designed to work with the ICT technique to enable real-time remote monitoring. Also, studies were done relating to the effect of reducing the standby power. The optimal frequency of IGBT devices used in industrial wireless power systems of 20[KHz] was utilized. The values of $23.9[{\mu}H]$ and $2.64[{\mu}F]$ were selected for L and C, respectively, through many field experiments designed to optimize the system design. In addition, an output current controlling algorithm was developed for the purpose of reducing the standby power. The results presented in this paper represent a 75[%] to 85[%] higher power transmission efficiency with a 10[%] increase in the effective power transmission distance compared with the existing systems. As a result, the proposed system exhibits a lower standby power and maintenance costs. Also, the designed wireless transceiver unit facilitates fault detection by means of user acquired data with the development of the ICT applied program.

CONFIDENCE LIMITS FOR STEADY STATE AVAILABILITY OF A REDUNDANT SYSTEM

  • Shin, Sang-Wook;Lim, Jae-Hak;Park, Dong-Ho
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2000.04a
    • /
    • pp.193-200
    • /
    • 2000
  • In this paper, we consider confidence limits for steady state availability of a redundant structure with the function of switchover processing. The system considered in this paper consists of three units which are an active unit, a standby unit and a switchover device. A control module does not affect the performance of the system while the active unit is operating but causes the system failure if the active unit fails at the failure of the control module. The effect of failure of control module is included in our reliability model of the simple redundant structure. The availability of the system is obtained by using the state space method. An example is given to illustrate our results.

  • PDF

Analysis of 2-Unit Systems with Two Types of Failures

  • Park, Yeong-Taek;Kim, Dae-Hong
    • Journal of Korean Society for Quality Management
    • /
    • v.11 no.2
    • /
    • pp.32-36
    • /
    • 1983
  • 2-Unit systems such as series, parallel, standby with two types of failures are considered. Closed form solutions for both the steady-state and time-dependent availability of 2-Unit system with two types of failures are developed.

  • PDF

Reliability Analysis of Diesel Generators of Wolsong Unit 1

  • Park, S. Y.;Kim, S. H.;Kim, K. Y.;Kim, T. W.;Y. S. Cho
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.502-507
    • /
    • 1997
  • As a maintenance optimization project to improve the safety of Wolsong NPP (Nuclear Power Plant), reliability of diesel generators are estimated based on the operating experience, and improvement options are suggested. A reliability measure is suggested for the estimation of reliability for standby safety systems to reflect availability. It is assessed that the reliability of diesel generators can be much improved if the suggested improvement options are implemented.

  • PDF

MBus: A Fully Synthesizable Low-power Portable Interconnect Bus for Millimeter-scale Sensor Systems

  • Lee, Inhee;Kuo, Ye-Sheng;Pannuto, Pat;Kim, Gyouho;Foo, Zhiyoong;Kempke, Ben;Jeong, Seokhyeon;Kim, Yejoong;Dutta, Prabal;Blaauw, David;Lee, Yoonmyung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.6
    • /
    • pp.745-753
    • /
    • 2016
  • This paper presents a fully synthesizable low power interconnect bus for millimeter-scale wireless sensor nodes. A segmented ring bus topology minimizes the required chip real estate with low input/output pad count for ultra-small form factors. By avoiding the conventional open drain-based solution, the bus can be fully synthesizable. Low power is achieved by obviating a need for local oscillators in member nodes. Also, aggressive power gating allows low-power standby mode with only 53 gates powered on. An integrated wakeup scheme is compatible with a power management unit that has nW standby mode. A 3-module system including the bus is fabricated in a 180 nm process. The entire system consumes 8 nW in standby mode, and the bus achieves 17.5 pJ/bit/chip.

Availability Analysis of 2N Redundancy System Using Stochastic Models (안정적인 서비스를 위한 2N 이중화 모델의 가용도 분석)

  • Kim, Dong Hyun;Lee, Yutae
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.11
    • /
    • pp.2634-2639
    • /
    • 2014
  • The idea of redundancy is used in order to improve the availability of networks and systems and there are various methods for implementing redundancy. To perform the availability analysis various stochastic models have been used. In this paper, 2N redundancy with one active service unit and one standby service unit is considered. To evaluate the expected availability, we model 2N redundancy using Stochastic Reward Nets. This model can be solved using the SPNP package.

An Architecture Model on Artificial Intelligence for Ground Tactical Echelons (지상 전술 제대 인공지능 아키텍처 모델)

  • Kim, Jun Sung;Park, Sang Chul
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.513-521
    • /
    • 2022
  • This study deals with an AI architecture model for collecting battlefield data using the tactical C4I system. Based on this model, the artificial staff can be utilized in tactical echelon. In the current structure of the Army's tactical C4I system, Servers are operated by brigade level and above and divided into an active and a standby server. In this C4I system structure, the AI server must also be installed in each unit and must be switched when the C4I server is switched. The tactical C4I system operates a server(DB) for each unit, so data matching is partially delayed or some data is not matched in the inter-working process between servers. To solve these issues, this study presents an operation concept so that all of alternate server can be integrated based on virtualization technology, which is used as an source data for AI Meta DB. In doing so, this study can provide criteria for the AI architectural model of the ground tactical echelon.