• Title/Summary/Keyword: standardized value

Search Result 549, Processing Time 0.034 seconds

Study of Apparent Diffusion Coefficient Changes According to Spinal Disease in MR Diffusion-weighted Image

  • Heo, Yeong-Cheol;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.146-149
    • /
    • 2017
  • In this study, we compared the standardized value of each signal intensity, the apparent diffusion coefficient (ADC) that digitizes the diffusion of water molecules, and the signal to noise ratio (SNR) using b value 0 400, 1400 ($s/mm^2$). From March 2013 to December 2013, patients with suspicion of simple compound fracture and metastatic spine cancer were included in the MR readout. We used a 1.5 Tesla Achieva MRI system and a Syn-Spine Coil. Sequence is a DWI SE-EPI sagittal (diffusion weighted imaging spin echo-echo planar imaging sagittal) image with b-factor ($s/mm^2$) 0, 400, 1400 were used. Data analysis showed ROI (Region of Interest) in diseased area with high SI (signal intensity) in diffusion-weighted image b value 0 ($s/mm^2$) Using the MRIcro program, each SI was calculated with images of b-value 0, 400, and 1400 ($s/mm^2$), ADC map was obtained using Metlab Software with each image of b-value, The ADC is obtained by applying the ROI to the same position. The standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of simple compression fractures were $0.47{\pm}0.04$ and $0.23{\pm}0.03$ and the standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of the metastatic spine were $0.57{\pm}0.07$ and $0.32{\pm}0.08$ And the standardized values of the two diseases were statistically significant (p < 0.05). The ADC ($mm^2/s$) for b value 400 ($s/mm^2$) and 1400 ($s/mm^2$) of the simple compression fracture disease site were $1.70{\pm}0.16$ and $0.93{\pm}0.28$ and $1.24{\pm}0.21$ and $0.80{\pm}0.15$ for the metastatic spine. The ADC ($mm^2/s$) for b value 400($s/mm^2$) was statistically significant (p < 0.05) but the ADC ($mm^2/s$) for b value 1400 (p > 0.05). In conclusion, multi - b value recognition of signal changes in diffusion - weighted imaging is very important for the diagnosis of various spinal diseases.

A Development of Railroad R&D Project Performance Analysis Method (철도사업 성과분석 표준매뉴얼 개발)

  • Jin, Il-Kyoung;Yoo, Jae-Kyun;Byun, Ji-Young
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.472-476
    • /
    • 2011
  • Railway R&D technology development projects for the economic value of technology development does not mention the estimated economic impact on future policies must reflect the issues that are raised. In the research phase of technology development by providing value and economic effects can increase the utilization of technology development are considered. However, some items in some way to analyze and quantify its effect on what the procedures are not standardized, not as needed by individual researchers and analysis by providing a variety of reliability problems can occur. Therefore, the development of technologies to measure the value and economic impact analysis and the development of a standardized manual is needed. In this paper, development of railway technology R & D performance (technical, economic) to be estimated by an objective analysis of standardized and that man should aim to create. And the standard manual of the national economic effect in the development of technologies (production inducement effect, the effect of import substitution industries, including analysis using the taxable year), due to technology development and economic benefits (investment in railways in the handbook and the feasibility of the proposed railway project to produce various ally standards), technology development, and on which to base the valuation will.

  • PDF

Additivity of digestible energy and nutrient concentrations in hatchery byproducts fed to nursery pigs

  • Sung, Jung Yeol;Ji, Sang Yun;Kim, Beob Gyun
    • Animal Bioscience
    • /
    • v.35 no.3
    • /
    • pp.453-460
    • /
    • 2022
  • Objective: The objective was to test additivity of digestible energy and nutrient concentrations in the hatchery byproduct mixture fed to nursery pigs. Methods: In the previous studies, energy, phosphorus, calcium, and amino acid digestibility of infertile eggs, unhatched eggs, culled chicks, and a mixture of 3 hatchery byproduct ingredients was determined in nursery pigs (initial body weight = 9.4 to 14.2 kg). An additivity test was conducted using these determined values. Results: No difference was observed between determined and predicted metabolizable energy values in the mixture (3,998 and 3,990 kcal/kg as-is basis, respectively). Measured standardized total tract digestible phosphorus in the mixture was less than the predicted value (4.5 vs 5.3 g/kg as-is basis, respectively; p<0.05). Measured standardized total tract digestible calcium in the mixture was greater compared with the predicted value (40.0 vs 31.7 g/kg as-is basis, respectively; p<0.05). Measured standardized ileal digestible tryptophan in the mixture was greater than the predicted value (3.7 vs 3.1 g/kg as-is basis, respectively; p<0.05) whereas other amino acid values were additive. Conclusion: Energy and most of amino acid concentrations in hatchery byproducts are additive in the mixture fed to nursery pigs.

Varietal Difference in Feed Value of Rice Straw and Its Relationship with Agronomic Traits (볏짚 사료가치의 품종간 차이 및 생육형질과의 관련성)

  • Kim Chang-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.49 no.6
    • /
    • pp.516-521
    • /
    • 2004
  • The straw of thirty one rice varieties were evaluated for their feed value and related agronomic traits. The rice straw were hand-harvested, dried to constant weight at $75^{\circ}C$ and ground through a 20 mesh seive in a Wiley mill, analyzed with crude protein (CP), acid detergent fiber (ADF) and neutral detergent fiber (NDF). Relative feed value (RFV) was calculated from NDF and ADF. The sum of standardized score was estimated by dry weight of rice straw, content of CP, ADF and NDF. The straw yield of Daeanbyeo was 725.9 kg/10a, showed heighest value among the varieties and remainder was in the order of Keumnambyeo, Donginbyeo #1 and Chucheongbyeo. Crude protein (CP) content in a Dasanbyeo was higher than those in other varieties. The content of ADF in a Junghwabyeo and NDF in a Sobaegbyeo were $34.3\%$ and $63.8\%$, respectively, showed lowest value among the varieties. The rice straw of Dunnaebyeo, Obongbyeo, Seoanbyeo, Keumobyeo, Hwaseongbyeo, Noganbyeo and Gyehwabyeo belonged to the high feed value varieties by estimation of cluster analysis, sum of standardized score and RFV. The content of CP was found to be positively related with dry weight of leaf and grain, but negatively related with heading days after seeding, culm length, specific leaf weight (SLW) and dry weight of stem. ADF and NDF were found to be positively related with heading days after seeding, culm length, SLW and dry weight of leaf, but negatively related with dry weight of stem. The sum of standardized score and RFV were the only positive relationship with dry weight of stem and negative relationship with other traits.

Effects of selection index coefficients that ignore reliability on economic weights and selection responses during practical selection

  • Togashi, Kenji;Adachi, Kazunori;Yasumori, Takanori;Kurogi, Kazuhito;Nozaki, Takayoshi;Onogi, Akio;Atagi, Yamato;Takahashi, Tsutomu
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.1
    • /
    • pp.19-25
    • /
    • 2018
  • Objective: In practical breeding, selection is often performed by ignoring the accuracy of evaluations and applying economic weights directly to the selection index coefficients of genetically standardized traits. The denominator of the standardized component trait of estimated genetic evaluations in practical selection varies with its reliability. Whereas theoretical methods for calculating the selection index coefficients of genetically standardized traits account for this variation, practical selection ignores reliability and assumes that it is equal to unity for each trait. The purpose of this study was to clarify the effects of ignoring the accuracy of the standardized component trait in selection criteria on selection responses and economic weights in retrospect. Methods: Theoretical methods were presented accounting for reliability of estimated genetic evaluations for the selection index composed of genetically standardized traits. Results: Selection responses and economic weights in retrospect resulting from practical selection were greater than those resulting from theoretical selection accounting for reliability when the accuracy of the estimated breeding value (EBV) or genomically enhanced breeding value (GEBV) was lower than those of the other traits in the index, but the opposite occurred when the accuracy of the EBV or GEBV was greater than those of the other traits. This trend was more conspicuous for traits with low economic weights than for those with high weights. Conclusion: Failure of the practical index to account for reliability yielded economic weights in retrospect that differed from those obtained with the theoretical index. Our results indicated that practical indices that ignore reliability delay genetic improvement. Therefore, selection practices need to account for reliability, especially when the reliabilities of the traits included in the index vary widely.

Development of a Standardized Recipe for Korean Cold Noodle Stock (냉면 육수 조립법의 표준화 연구)

  • 김업식;최일숙;구성자
    • Korean journal of food and cookery science
    • /
    • v.17 no.6
    • /
    • pp.589-597
    • /
    • 2001
  • This study was conducted to develop a standardized Korean cold noodle stock recipe which can be used in food service establishments. The qualities of three kinds of stock made of beef rib only(B group), beef rib added with chicken(BC group), and beef rib added with chicken and vegetable(BCV group) were investigated by using sensory evaluation and instrumental analyses for free amino acids and nucleotides during heating (2, 3, 4, and 6 hr) at 90$\pm$ 5$\^{C}$ The highest amino acid contained in B, BCV, and BCV groups was arginine followed by alanine, glycine, and glutamic acid. B and BC groups was extracted to the best contents of amino acids by heating for 4 hours but BCV group for 3 hours. Nucleotides were extracted from B and BC group between 3 and 4 hours of heating but in BCV group between 2 and 3 hours. In sensory evaluation, BCV group obtained the highest score for overall preference. In the measurement of color difference, BCV group was the lowest in L value(lightness) but the highest in b value(yellowness).

  • PDF

Maximum standardized uptake value at pre-treatment PET in estimating lung cancer progression after stereotactic body radiotherapy

  • Park, Jisun;Choi, Yunseon;Ahn, Ki Jung;Park, Sung Kwang;Cho, Heunglae;Lee, Ji Young
    • Radiation Oncology Journal
    • /
    • v.37 no.1
    • /
    • pp.30-36
    • /
    • 2019
  • Purpose: This study aimed to identify the feasibility of the maximum standardized uptake value (SUVmax) on baseline 18F-fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET/CT) as a predictive factor for prognosis in early stage primary lung cancer treated with stereotactic body radiotherapy (SBRT). Materials and Methods: Twenty-seven T1-3N0M0 primary lung cancer patients treated with curative SBRT between 2010 and 2018 were retrospectively evaluated. Four patients (14.8%) treated with SBRT to address residual tumor after wedge resection and one patient (3.7%) with local recurrence after resection were included. The SUVmax at baseline PET/CT was assessed to determine its relationship with prognosis after SBRT. Patients were divided into two groups based on maximum SUVmax on pre-treatment FDG PET/CT, estimated by receiver operating characteristic curve. Results: The median follow-up period was 17.7 months (range, 2.3 to 60.0 months). The actuarial 2-year local control, progression-free survival (PFS), and overall survival were 80.4%, 66.0%, and 78.2%, respectively. With regard to failure patterns, 5 patients exhibited local failure (in-field failure, 18.5%), 1 (3.7%) experienced regional nodal relapse, and other 2 (7.4%) developed distant failure. SUVmax was significantly correlated with progression (p = 0.08, optimal cut-off point SUVmax > 5.1). PFS was significantly influenced by pretreatment SUVmax (SUVmax > 5.1 vs. SUVmax ≤ 5.1; p = 0.012) and T stage (T1 vs. T2-3; p = 0.012). Conclusion: SUVmax at pre-treatment FDG PET/CT demonstrated a predictive value for PFS after SBRT for lung cancer.

Study on the Difference of Standardized Uptake Value in Fusion Image of Nuclear Medicine (핵의학 융합영상의 표준섭취계수 차이에 관한 연구)

  • Kim, Jung-Soo;Park, Chan-Rok
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.553-560
    • /
    • 2018
  • PET-CT and PET-MRI which integrates CT using ionized radiation and MRI using phenomena of magnetic resonance are determined to have the limitation to apply the semi-quantitative index, standardized uptake value (SUV), with the same level due to the fundamental differences of image capturing principle and reorganization, hence, their correlations were analyzed to provide their clinical information. To 30 study subjects maintaining pre-treatment, $^{18}F-FDG$ (5.18 MBq/㎏) was injected and they were scanned continuously without delaying time using $Biograph^{TM}$ mMR 3T (Siemens, Munich) and Biograph mCT 64 (Siemens, Germany), which is an integral type, under the optimized condition except the structural differences of both scanners. Upon the measurement results of $SUV_{max}$ setting volume region of interest with evenly distributed radioactive pharmaceuticals by captured images, $SUV_{max}$ mean values of PET-CT and PET-MRI were $2.94{\pm}0.55$ and $2.45{\pm}0.52$, respectively, and the value of PET-MRI was measured lower by $-20.85{\pm}7.26%$ than that of PET-CT. Also, there was a statistically significant difference in SUVs between two scanners (P<0.001), hence, SUV of PET-CT and PET-MRI cannot express the clinical meanings in the same level. Therefore, in case of the patients who undergo cross follow-up tests with PET-CT and PET-MRI, diagnostic information should be analyzed considering the conditions of SUV differences in both scanners.

Region of Interest Analysis for Standardized Uptake Value Ratio of 18F-fludeoxyglucose PET: Mild Cognitive Impairment and Alzheimer's Disease (경도인지장애와 알츠하이머병 환자의 18F-fludeoxyglucose PET 표준 섭취계수율에 대한 체적 및 피질 표면 기반 관심영역 분석)

  • Kim, Seonjik;Yoon, Uicheul
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.237-242
    • /
    • 2018
  • $^{18}F$-fludeoxyglucose PET (FDG-PET) can help finding an abnormal metabolic activity in brain. In this study, we evaluated an efficiency of volume- and cortical surface-based analysis which were used to determine whether standardized uptake value ratio (SUVR) of FDG-PET was different among Alzheimer's disease (AD), mild cognitive impairment (MCI), and healthy control (HC). Each PET image was rigidly co-registered to the corresponding magnetic resonance imaging (MRI) using mutual information. All voxels of the co-registered PET images were divided by the mean FDG uptake of the cerebellum cortex which was thresholded by partial volume effect (>0.9). Also, the SUVR value of each vertex was linearly interpolated from volumetric SUVR image which was thresholded by gray matter partial volume effect (>0.1). Lobar mean values were calculated from both volume- and cortical surface-based SUVRs. Statistical analysis was conducted to compare two measures for AD, MCI and HC groups. Even though the results of volume (SUVR_vol) and cortical surface-based SUVR (SUVR_surf) analysis were not significantly different from each other, the latter would be better for detecting group differences in SUVR of PET.

Economic Values for Dairy Sheep Breeds in Slovakia

  • Krupova, Zuzana;Wolfova, M.;Wolf, J.;Oravcova, M.;Margetin, M.;Peskovicova, D.;Krupa, E.;Dano, J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.12
    • /
    • pp.1693-1702
    • /
    • 2009
  • Economic values of 14 production and functional traits for two Slovak dairy sheep breeds (Improved Valachian and Tsigai) were calculated. Semi-extensive production systems with one lambing per year were simulated using a bio-economic deterministic computer model. The marginal economic value of a trait was defined as the partial derivative of the profit function with respect to that trait. The relative economic value expressed the percentage proportion of standardized economic value (marginal economic value${\times}$genetic standard deviation) of a trait in the sum of the absolute values of the standardized economic values over all traits. Milk yield was of highest relative importance (26% and 32% in Improved Valachian and Tsigai) followed by productive lifetime and conception rate of ewes (16% and 15% in Improved Valachian and Tsigai, in both traits). Conception rate of female lambs and litter size had nearly the same relative economic importance in both breeds (9% to 11%). Survival rate of lambs at lambing and till weaning reached slightly lower economic values (4% to 7%). The economic importance of all remaining traits was less than 4%.