• Title/Summary/Keyword: standardized test

Search Result 1,001, Processing Time 0.035 seconds

Reliability and Responsiveness of the Korean Version of the Trunk Impairment Scale for Stroke Patients

  • Ko, Jooyeon;You, Youngyoul
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.4
    • /
    • pp.175-182
    • /
    • 2015
  • Purpose: The purposes of this study were to develop the Korean version of the trunk impairment scale (K-TIS) and to examine reliability and responsiveness of the K-TIS in patients with stroke. Methods Subjects of the study were 51 stroke patients (mean age: 57.78 years) recruited from two stroke clinics. For the interrater and test-retest reliability, two raters measured the K-TIS two times using video clips with an interval of 2 weeks. For the responsiveness, intensive physical therapy training was provided to all participants 2 times a day for one month or three months depending on the onset of the stroke and the admission rules of the two clinics. Inter-rater reliability and test-retest reliability of the K-TIS three subscales (static sitting balance, dynamic sitting balance, and coordination) scores and total scores were examined using intra-correlation coefficient ($ICC_{3,1}$) and Pearson's correlation coefficient (r). To examine responsiveness, the minimally important difference (MID) was calculated with effect size. Results: Inter-rater reliability of the K-TIS subscales and total scores were all high (ICC3,1=0.920-0.983 and r=0.924-0.984). For the test-retest reliability, $ICC_{3,1}$=0.805-0.901 and r=0.806-0.903, and the MID for acute and post-acute as well as chronic stroke patients remained in the mean change range. Conclusion: It is suggested that the K-TIS might be used for clinical and research purposes as a standardized tool for stroke patients. In addition, it can also be useful in establishment of treatment goal(s) and planning treatment program(s) for patients with stroke.

Microscopical and chemical surface characterization of CAD/CAM zircona abutments after different cleaning procedures. A qualitative analysis

  • Gehrke, Peter;Tabellion, Astrid;Fischer, Carsten
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.2
    • /
    • pp.151-159
    • /
    • 2015
  • PURPOSE. To describe and characterize the surface topography and cleanliness of CAD/CAM manufactured zirconia abutments after steaming and ultrasonic cleaning. MATERIALS AND METHODS. A total of 12 ceramic CAD/CAM implant abutments of various manufacturers were produced and randomly divided into two groups of six samples each (control and test group). Four two-piece hybrid abutments and two one-piece abutments made of zirconium-dioxide were assessed per each group. In the control group, cleaning by steam was performed. The test group underwent an ultrasonic cleaning procedure with acetone, ethyl alcohol and antibacterial solution. Groups were subjected to scanning electron microscope (SEM) analysis and Energy-dispersive X-ray spectroscopy (EDX) to verify and characterize contaminant chemical characterization non- quantitatively. RESULTS. All zirconia CAD/CAM abutments in the present study displayed production-induced wear particles, debris as well as organic and inorganic contaminants. The abutments of the test group showed reduction of surface contamination after undergoing an ultrasonic cleaning procedure. However, an absolute removal of pollutants could not be achieved. CONCLUSION. The presence of debris on the transmucosal surface of CAD/CAM zirconia abutments of various manufacturers was confirmed. Within the limits of the study design, the results suggest that a defined ultrasonic cleaning process can be advantageously employed to reduce such debris, thus, supposedly enhancing soft tissue healing. Although the adverse long-term influence of abutment contamination on the biological stability of peri-implant tissues has been evidenced, a standardized and validated polishing and cleaning protocol still has to be implemented.

A Study on Job Satisfaction and Stress in Relation to Job Features of Nursing Assistants - Case Study with Nursing Assistants in Seoul Metropolitan City - (간호조무사의 직무영역별특성이 직무만족도와 스트레스에 미치는 영향 -서울시 의료기관 근무자 중심으로-)

  • Yang, Kab-Suk;Cho, Sung-Je
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2859-2869
    • /
    • 2014
  • The present study aims to examine job satisfaction and stress in relation to features of jobs taken by nursing assistants. The subjects for study are 469 nursing assistants active at work in various medical clinics and hospitals in Seoul Metropolitan City, engaged in a study conducted from May 1, 2013 through September 4, 2013. The positive analysis was verified at a significance level of five percent, and SPSS/WIN18.0 was used for statistics process. The analysis of frequency, t-test, one-way analysis of variance, and multiple regression analysis were conducted, and was then analyzed by multiple range test for statistics. The analysis reveals that job satisfaction level marks significant variance in accordance to the year of nursing assistant certificate acquired, age, and their final academic backgrounds. As to the job satisfaction variances in accordance to job features, the location of working places, fields of jobs, and the mode of jobs mark the highest. The study indicates that standardized directions for tasks in specific fields of jobs and education programs should be implemented for consistent management are requisite for improved efficiency of nursing assistants and professional nursing workforce.

Immediate effects of a neurodynamic sciatic nerve sliding technique on hamstring flexibility and postural balance in healthy adults

  • Park, Jaemyoung;Cha, Jaeyun;Kim, Hyunjin;Asakawa, Yasuyoshi
    • Physical Therapy Rehabilitation Science
    • /
    • v.3 no.1
    • /
    • pp.38-42
    • /
    • 2014
  • Objective: In this study, we applied a neurodynamic sciatic nerve sliding technique to healthy adults to elucidate its effects on hamstring flexibility and postural balance. Design: Cross-sectional study. Methods: This study targeted twenty four healthy adults (16 men, 8 women). A neurodynamic sciatic nerve sliding technique was applied 5 times to all subjects' dominant leg. The subjects were asked to sit on the bed while performing cervical and thoracic flexion, as well as knee flexion with ankle plantar flexion. Then, they were asked to perform cervical and thoracic extension and knee extension with their ankle in dorsiflexion and maintain the position for 60 s. For postural balance, we measured postural sway while the subjects maintained a one-legged standing posture using the Good Balance System and measured the hip joint flexion range of motion using a standardized passive straight leg raise (SLR) test. Results: SLR test increased significantly from $79^{\circ}$ before the intervention to $91.67^{\circ}$ after the intervention (p<0.05). Regarding the participants' balance evaluated using the one-legged standing test, the X-speed decreased significantly from 18.61 mm/s to 17.17 mm/s (p<0.05), the Y-speed decreased from 22.28 mm/s to 20.52 mm/s (p<0.05), and the velocity moment was significantly decreased from $89.33mm^2/s$ to $74.99mm^2/s$ after the intervention (p<0.05). Conclusions: Application of the neurodynamic sciatic nerve sliding technique exhibited improved hamstring flexibility and postural balance of healthy adults.

Reliability and Validity of The Korean Version Scale of Impact of Weight on Quality of Life in $Kids^{(C)}$ (한국어 버전 청소년의 체중 관련 삶의 질 측정도구의 신뢰도와 타당도 검증)

  • Kim, Jeoung-Hyun;Chun, Sungsoo;Choi, Han-Sik
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.15 no.3
    • /
    • pp.105-125
    • /
    • 2014
  • Background: The purpose of this study was to evaluate reliability and validity of a 27-item Korean Version of the Impact of Weight on Quality of Life in adolescents ($IWQOL-Kids^{(C)}$: Korean Version). Methods: This instrument was administered to 872 adolescents (mean z-BMI: 2.61, mean $age{\pm}SD$: $13.9{\pm}1.2$, male: 51.9%). Reliability was tested by internal consistency method and item analysis, validity test was performed by index of content validity, exploratory factor analysis, confirmatory factor analysis and concurrent validity. Sensitivity was tested by ANOVA and t-test. Analyses were performed using SPSS and Amos 18.0. Results: By an exploratory factor analysis, 4 factors were extracted; 'Body esteem' consisted of 9 items with 35.9% of variance (social life: 6 items, 10.23%, physical comfort: 6 items, 8.21%, family relations: 6 items, 7.0%). Four factors explained 61.34% of total variance. Internal consistency coefficients ranged from .766 to .929 for scales on 27 items and equal to .920 for total score for both the 26-item and 27-item tools. A confirmatory factor analysis was conducted for the convergent validity and discriminant validity. The standardized factor loadings to test the convergent validity showed more than .5(C.R<1.965) on all paths after deletion of item PC1 (avoid stairs). The average variances extracted were more than .50 and the construct reliabilities were more than .70. The average variances extracted were stronger than the squares of correlation coefficient of inter-latent variables. Conclusions: These results support that the $IWQOL-Kids^{(C)}$: Korean Version with a 26-item is a reliable and valid tool in Korean obese adolescents.

  • PDF

The Selection of Representative Drive Course for Small Tactical Vehicles Through Movement Condition and Operational Environment Analysis (소형전술차량 기동조건 및 운용환경 분석을 통한 대표주행경로 선정)

  • Kim, Juhee;Lee, Jongwoo;Yoo, Samhyeun;Park, Ji-il;Shin, Hyunseung;Kwon, Youngjin;Choi, Hyunho
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.341-352
    • /
    • 2019
  • LTV(Light Tactical vehicle) operating in our military requires higher levels of performance and durability to withstand harsher conditions than ordinary vehicles, as they must travel on both rough-train and off-road as well as on public roads. Recently, developed light tactical vehicle is developed by a variety of test evaluations in order to satisfy ROC(Required Operational Capability) by the requirement military group. However, there is no standardized driving test condition for satisfying the durability performance of Korean tactical vehicle. Therefore, this study aims to provide basic data to establish reliable driving test conditions by analyzing the maneuver conditions and the driving data in order to select the representative drive course required. To do this, we analyzed the future operational environment, the area of operation analysis and the driving information of light tactical vehicle.

Reference ranges for autonomic function tests in healthy korean adults

  • Park, Kee Hong;Kim, Byoung Joon;Kang, Sa-Yoon;Oh, Sun-Young;Sohn, Eun Hee;Song, Kyeong-jin;Shin, Jin-Hong;Kang, Kyoung Hwa;Cho, Eun Bin;Jeong, Heejeong;Lee, Hyung;Kim, Hyun Ah;Kim, Rock Bum;Park, Ki-Jong
    • Annals of Clinical Neurophysiology
    • /
    • v.21 no.2
    • /
    • pp.87-93
    • /
    • 2019
  • Background: The standardized autonomic function test has become widely available. However, there are no reference data for this test for the Korean population. This study explored reference data for sudomotor and cardiovagal function tests for the Korean population. Methods: The sweat volume by quantitative sudomotor axon reflex test, heart-rate response to deep breathing (HRdb), expiration:inspiration (E:I) ratio, and Valsalva ratio (VR) were measured in 297 healthy Korean volunteers aged from 20 to 69 years. Multivariate regression analysis was performed to evaluate the effects of age, sex, and body mass index on these variables. The 2.5th, 5th, 10th, 90th, 95th, and 97.5th percentile values were obtained for each investigation. Results: The sweat volume was higher in males than in females. The HRdb and E:I ratio were negatively correlated with age, and were higher in males than in females. The VR was negatively correlated with age, but it was not correlated with sex. Conclusions: This study has provided data on the reference ranges for sudomotor and cardiovagal function tests in healthy Korean adults.

Variations of Building Methods and Costs of Modernized Hanok Test-bed Projects (실증구축을 통한 신한옥의 신공법 및 공사비 변화 요인 도출)

  • Seo, Nuri;Kang, Seunghee;Lee, Yunsub;Jin, Zhenhui;Jeong, Yeheun;Jung, Youngsoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.3
    • /
    • pp.86-96
    • /
    • 2019
  • The research efforts to modernize Hanok (Korean traditional housing) have been performed to improve the quality and cost-effectiveness through application of modern building methods and materials, and to disseminate it in various forms of sizes and facilities. In this study, in order to identify the variations of modernized Hanok, data from seven test-bed projects are analyzed based on the building work-section, element, method, and material. The data were standardized and managed through the modernized Hanok classification system (Hanclass) to facilitate systematic comparisons of the test-bed projects by the variation of building method and it's cost impact. Identified factors of the variation in terms of building methods were then itemized and quantified in terms of building cost. Findings of this study indicate that the timber structure is the most critical area for future variation for improving the quality and cost-effectiveness. The results of this study will be also used to systemize the Hanok database for further studies.

Microbiological cleaning and disinfection efficacy of a three-stage ultrasonic processing protocol for CAD-CAM implant abutments

  • Gehrke, Peter;Riebe, Oliver;Fischer, Carsten;Weinhold, Octavio;Dhom, Gunter;Sader, Robert;Weigl, Paul
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.5
    • /
    • pp.273-284
    • /
    • 2022
  • PURPOSE. Computer-aided design and manufacturing (CAD-CAM) of implant abutments has been shown to result in surface contamination from site-specific milling and fabrication processes. If not removed, these contaminants can have a potentially adverse effect and may trigger inflammatory responses of the peri-implant tissues. The aim of the present study was to evaluate the bacterial disinfection and cleaning efficacy of ultrasonic reprocessing in approved disinfectants to reduce the microbial load of CAD-CAM abutments. MATERIALS AND METHODS. Four different types of custom implant abutments (total N = 32) with eight specimens in each test group (type I to IV) were CAD-CAM manufactured. In two separate contamination experiments, specimens were contaminated with heparinized sheep blood alone and with heparinized sheep blood and the test bacterium Enterococcus faecium. Abutments in the test group were processed according to a three-stage ultrasonic protocol and assessed qualitatively and quantitatively by determination of residual protein. Ultrasonicated specimens contaminated with sheep blood and E. faecium were additionally eluted and the dilutions were incubated on agar plates for seven days. The determined bacterial counts were expressed as colony-forming units (CFU). RESULTS. Ultrasonic reprocessing resulted in a substantial decrease in residual bacterial protein to less than 80 ㎍ and a reduction in microbiota of more than 7 log levels of CFU for all abutment types, exceeding the effect required for disinfection. CONCLUSION. A three-stage ultrasonic cleaning and disinfection protocol results in effective bacterial decontamination. The procedure is reproducible and complies with the standardized reprocessing and disinfection specifications for one- or two-piece CAD-CAM implant abutments.

Standardized Extract (HemoHIM) Ameliorated High Intensity Exercise Induced Fatigue in Mice

  • Lee, Hyun Jun;Kim, Sang Back;Boo, Kyung Jun;Ortiz, Darlene Mae;Sayson, Leandro Val;Custodio, Raly James Perez;Cheong, Jae Hoon;Kim, Seul Ki;Kim, Mikyung;Kim, Hee Jin
    • Natural Product Sciences
    • /
    • v.28 no.2
    • /
    • pp.68-74
    • /
    • 2022
  • HemoHIM was used as a Korean traditional medicine for anti-inflammatory and antioxidant effects. However, there is no study on the effect of HemoHIM on fatigue. We examined the potential use of HemoHIM to determine whether it can induce anti-fatigue effects. Mice were administered with HemoHIM and VEH for 14 days. On the last day of treatment, mice were subjected to behavioral tests. Subsequently, their plasma and muscle were collected after the treadmill test to measure lactate, lactate dehydrogenase (LDH), ammonia, corticosterone, glycogen, and creatine kinase (CK). We found that HemoHIM moderately increased the running time (s) in the treadmill and mobility duration in the cold swimming tests. In addition, the VEH group showed a significant increase in lactate, LDH, and corticosterone levels in the plasma compared to the group that did not perform the test. However, this was moderately reduced in HemoHIM treatment. Moreover, the HemoHIM-treated group showed significant differences in LDH and glycogen levels, and showed significantly different CK levels in the muscle. HemoHIM is considered to be effective in improving fatigue, given the duration of cold swimming or running time on a treadmill. Also, HemoHIM treatment resulted in reduced concentrations of blood and muscle parameter analysis.