• Title/Summary/Keyword: standard testing method

Search Result 576, Processing Time 0.026 seconds

Development of an Nursing Assessment Tool for Emergency Patients (응급환자 간호사정 도구개발)

  • Ahn, Mi-Hyun
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.4 no.2
    • /
    • pp.419-437
    • /
    • 1998
  • Nurses use a nursing process. that is a scientific approach method. in order to understand the clients' condition and to solve their problems. Professional nurses have accepted the nursing process as a standard framework for nursing activities, and the first step of the nursing process is nursing assessment. The purpose of this study was to develop a nursing assessment tool for emergency patients. Assessment is a first step in the nursing process, and scientific assessment helps to better understand the patients. Thus the development of an assessment tool for emergency patients will improve of nursing quality and advance to efficacy of emergency room(ER) management. The study involved the development of a conceptual framework, preliminary tool, content validity verification process. and reliability verification process. The conceptual framework was developed through a review of the literature. and preliminary tool was developed from the conceptual framework that based on care flow sheet' developed James A. Haley. The preliminary tool was evaluated for validity and reliability by seven experts, one ER nurse manager, two ER head nurses, two emergency medicine doctors. and two ER charge nurses and by ten nurses with one to five year careers in ER nursing. The results of this study was as follows 1. The conceptual framework which was developed was composed of three parts. They were triage criteria, first assessment and secondary assessment. 2. The preliminary tool which was developed had 31 items based on the conceptual framework. 3. To test expert validity a 4-point scale was used. items which had gained 3-4 points from six persons of the seven experts were selected. All 31 items from the preliminary tool were selected. 4. The reliability test was done by ten nurses educated in the use of the assessment tool. Two pairs of nurses simultaneously assessed the same patients. A total agreement percentile was calculated and result was 87.3% agreement. 5. After the validity and reliability testing. the final emergency patient nursing assessment tool was finalized with 31 items. and a check-list for the responses. This study concludes that the tool which was developed is both valid and reliable will advance quality care for emergency patients. This emergency nursing assessment tool was also found to be an adequate tool for assessment of emergency patients.

  • PDF

The Energy-Efficient Automatic Power Controller of The Signboard using Illuminance Detector (조도 감지기를 이용한 절전형 간판 자동 전원 제어기)

  • Ra, Seung-Tak;Lim, Song-Hwan;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.20 no.2
    • /
    • pp.188-191
    • /
    • 2016
  • In this paper, we propose energy-efficient automatic power controller which can power on and off the signboard at the specified light intensity using the Illuminance Detector. By using segmented section Classification algorithm, light intensity setup system propose variable resistor method which makes users more easy to control. Automatic light on-off system set a standard by measured illuminance data. Measured light-intensity through the Illuminance Detector are communicated with the signboard power controller with wireless communication, and it controls lighting system. In this paper, we evaluated the Energy-Efficient Automatic Power Controller of The Signboard using illuminance detector. Experimental results in lightless environment shows that the error rate is less than 3% by Accredited Testing Laboratories.

Comparison of Impact Sound Insulation Performances of Apartment Floors Against Heavy-weight Impact Sources via Field Measurement Data (공동주택 현장 측정자료를 활용한 중량충격원의 바닥충격음 차단성능 비교)

  • Yun, Chang-Yeon;Yeon, Jun-Oh;Kim, Myung-Jun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.8
    • /
    • pp.651-658
    • /
    • 2014
  • Notification 2013-611 of MOLIT has come into effect. It relates primarily to new standard impact source. In this study, an in-depth experimental analysis of the difference between a bang machine and an impact ball was performed via field testing of shear wall and flat plate structure at 51 sites. This paper focuses on the difference in single number quantities between a bang machine and an impact ball. At wall thicknesses of 180 and 210 mm in shear wall structure, the single number quantities exhibited differences of 3.1 and 4.5 dB, respectively, and at thicknesses exceeding 250 mm in flat plate structure, the difference was constant at 4.6 dB. With regard to flat plate structures, the single-index difference increased up to 11 dB as the thickness of the floor slab increased. In general, the highest level of contribution for the bang machine was 63 Hz, irrespective of thickness determining bandwidth. The highest level for the impact ball were 63 Hz and 125 Hz. In future research, when reviewing additional field performance measurement data, it will be necessary to consider a detailed examination instead of the current method of uniformly adding 3 dB for all thicknesses and types of structures.

Automation of Dobson Spectrophotometer(No.124) for Ozone Measurements (돕슨 분광광도계(No.124)의 오존 자동관측시스템화)

  • Kim, Jhoon;Park, Sang-Seo;Moon, Kyung-Jung;Koo, Ja-Ho;Lee, Yun-Gon;Miyagawa, Koji;Cho, Hi-Ku
    • Atmosphere
    • /
    • v.17 no.4
    • /
    • pp.339-348
    • /
    • 2007
  • Global Environment Laboratory at Yonsei University in Seoul ($37.57^{\circ}N$, $126.95^{\circ}E$) has carried out the ozone layer monitoring program in the framework of the Global Ozone Observing System of the World Meteorlogical Organization (WMO/GAW/GO3OS Station No. 252) since May of 1984. The daily measurements of total ozone and the vertical distribution of ozone amount have been made with the Dobson Spectrophotometer (No.124) on the roof of the Science Building on Yonsei campus. From 2004 through 2006, major parts of the manual operations are automated in measuring total ozone amount and vertical ozone profile through Umkehr method, and calibrating instrument by standard lamp tests with new hardware and software including step motor, rotary encoder, controller, and visual display. This system takes full advantage of Windows interface and information technology to realize adaptability to the latest Windows PC and flexible data processing system. This automatic system also utilizes card slot of desktop personal computer to control various types of boards in the driving unit for operating Dobson spectrophotometer and testing devices. Thus, by automating most of the manual work both in instrument operation and in data processing, subjective human errors and individual differences are eliminated. It is therefore found that the ozone data quality has been distinctly upgraded after automation of the Dobson instrument.

Characteristics of Heart Rate Variability Among Adults with Metabolic Syndrome (대사증후군 집단의 심박동수 변이의 특징)

  • Yeo, Do Hwan;Kim, Jeong Il;Kang, Dong Mug;Kim, Jeong Yeon;Cho, Jung Hin;Kim, Won;Lim, Seong Kyeon;Woo, Jong-Min
    • Korean Journal of Biological Psychiatry
    • /
    • v.15 no.3
    • /
    • pp.186-193
    • /
    • 2008
  • Objectives : The authors tried to investigate the characteristics of Heart Rate Variability(HRV) among the subjects with metabolic syndrome for testing the possibility of clinical application of HRV in evaluating metabolic syndrome. Methods : We examined the difference of the means of HRV between 122 subjects of metabolic syndrome and 1057 healthy controls using T-test, and the change of means in HRV according to increasing risk factors of metabolic syndrome. Using multiple regression analysis, we examined the association of HRV with the risk factors of metabolic syndrome. Results : The HRV indices including SDNN(Standard Deviation of all normal NN intervals), RMSSD(the square Root of the Mean Squared Differences of successive all normal NN interval), TP(Total Power), LF(Low Freuency), and HF(High Frequency) were significantly lower in the metabolic syndrome group than in the normal control group, and the means of all HRV indices except LF/HF were decreased consistently according to increasing risk factors of metabolic syndrome. The fasting glucose, triglyceride, and waist circumference were dependent factors that contributed significantly to the change of HRV. Conclusion : These findings suggest metabolic syndrome adversely affects cardiac autonomic system and HRV could be a useful method for evaluating metabolic syndrome.

  • PDF

Analysis of Toxic-PCBs in Sediment by Isotope Dilution HRGC/HRMS (Isotope Dilution HRGC/HRMS 방법을 이용한 저니토중 Toxic-PCBs 분석)

  • Jang, Seong-Ki;Choi, Duk-Il;Park, Sun-Ku;Kim, Kyung-Sup
    • Analytical Science and Technology
    • /
    • v.12 no.6
    • /
    • pp.550-557
    • /
    • 1999
  • This Analysis was conducted for 13 toxic-PCBs having TEF value among 209 PCBs isomers in sediment by isotope dilution HRGC/HRMS method. From the result, the recovery of surrogate standard was in the range of 71~99%. The concentration range for 13 toxic-PCBs in sediment was found to be 0.84~2.49 ng/g, among them the concentration levels of 2,2',3,3',4,4',5-HpCB(IUPAC No. 170) and 2,2',3,4,4',5,5'-HpCB(IUPAC No. 180) represented almost 50% of total concentrarion and that of 2,3,4,4,5-PeCB(IUPAC No. 114) showed over 10%. The TEQ concentration levelwas in the range of 0.38~2.63 pg-TEQ/g and 3,3',4,4',5-PeCB(IUPAC No. 126) concentration represented over 50% of total TEQ concentration.

  • PDF

MORPHOMETRIC ANALYSIS OF PLECOGLOSSUS ALTIVELIS OF CHEJU ISLAND AND THE NAKDONG RIVER (제주도 및 낙동강산 은어군의 형태 측정학적 분석)

  • Kim Eul-Bae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.3 no.4
    • /
    • pp.228-232
    • /
    • 1970
  • From the standpoint of fishery science it is an interesting matter to note that the size of Plecoglessus altivelis population on Cheju Island is smaller than that of the Nakdong River located in the southern part of Korea's mainland. Therefore the author carried out a comparative analysis to determine whether the populations differ because of racial or because of environmental conditions. The morphometric characters of the head length and the body length were used for the analysis of covariance and computed by a standard regression method of testing for the homogeneity of the populations. All samples were collected during 1968 and 1969 in the Milyang Stream of the Nakdong River and the Cheonji Stream of Cheju Island. The results of the analysis of the populations based on the significance test are as follows: 1. Since the F value observed was only 1.023 ($n_1=1,\;n_2=42$) the conclusion was reached that the samples could both belong to the same population. 2. In comparison with the deviations of the regression coefficients between the fish of the Nakdong River and Cherinji Stream, the populations were also highly significant suggesting that thelr belong to the same population. 3. The conclusion is that the fish of Cheju Island became a smaller fish in size due to an environmental condition but not due to racial characteristics.

  • PDF

Usefulness of Clinical Performance Examination for Graduation Certification of Nursing Students (졸업인증 임상수행력평가의 유용성 평가)

  • Kim, Yun-Hee;Kang, Seo-Young;Kim, Mi-Won;Jang, Keum-Seong;Choi, Ja-Yun
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.14 no.3
    • /
    • pp.344-351
    • /
    • 2008
  • Purpose: The aim of this study was to testify whether clinical performance examination (CPX) was useful to evaluate comprehensive performance for nursing students just prior to graduation. Method: A cross-sectional descriptive study was designed to examine the usefulness. A total of 61 nursing students whose requirement credits were completed for graduation from a C University in G-city, at December, 5, 2007. Data were analyzed by Pearson's Correlation Coefficient and Spearman's rank Correlation Coefficient. Results: This study showed that both of the finals scores with paper and pens and the clinical practicum scores were not correlated with the CPX scores (r=-.031, p=.811; r=.028, p=.831). Consistency of scores between faculties and standardized patients was moderate (r=.752, p=.000). Conclusion: CPX was considered as a different and innovative evaluation from previous testing systems to test the various aspects of performance including knowledge, skill and attitude. Therefore, CPX under high raters' consistency was useful to test nursing students's final performance. Further study would be needed to develop the standard of CPX system.

  • PDF

A Comparison of Static and Dynamic Deformation Modulus by Dynamic Plate Test (동평판 재하시험을 이용한 정적 및 동적 변형계수 비교)

  • 박용부;정형식
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.335-342
    • /
    • 2003
  • The method of measuring ground deformation modulus, in situ-testing has the disadvantage where the exam number is limited because it needs counter weight and a lot of measurement times. Recently, it has supplemented this problem and the equipments by which measurement can be made quickly are developed and applied in field., That is Falling Weight Deflectometer(FWD), Light Drop Weight Tester(LDWT), Geogauge. Light Drop Weight Teste.(LDWT) is introduced firstly in the name of ‘a lightweight fall circuit tester for a railroad public corporation’ by KTX. Since KTX introduced LDWT, a number of research organizations have used LDWT to find out domestic standard for quality management of base ground. In this study we used ZFG 02 which was manufactured by Stendal in Germany and measured the dynamic deformation modulus in soil box and in-situ. And we analyzed the correlation of the dynamic deformation modulus with static deformation modulus based on plate test in the same ground.

Estimation of User Activity States for Context-Aware Computing in Mobile Devices (모바일 디바이스에서 상황인식 컴퓨팅을 위한 사용자 활동 상태 추정)

  • Baek Jonghun;Yun Byoung-Ju
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.1 s.307
    • /
    • pp.67-74
    • /
    • 2006
  • Contort-aware computing technology is one of the key technology of ubiquitous computing in the mobile device environment. Context recognition computing enables computer applications that automatically respond to user's everyday activity to be realized. In this paper, We use accelerometer could sense activity states of the object and apply to mobile devices. This method for estimating human motion states utilizes various statistics of accelerometer data, such as mean, standard variation, and skewness, as features for classification, and is expected to be more effective than other existing methods that rely on only a few simple statistics. Classification algorithm uses simple decision tree instead of existing neural network by considering mobile devices with limited resources. A series of experiments for testing the effectiveness of the our context detection system for mobile applications and ubiquitous computing has been performed, and its result is presented.