• Title/Summary/Keyword: standard testing method

Search Result 578, Processing Time 0.024 seconds

The Suggestion of Testing Method for Analysis of Tensile Strength of Multi-Directional GFRP Plate (다방향 GFRP 플레이트의 인장강도 분석을 위한 시험 방법 제안에 관한 연구)

  • Sim, Jong-Sung;Kwon, Hyuck-Woo;Lee, Hyoung-Ho;Kim, Hyun-Joong
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.6
    • /
    • pp.799-808
    • /
    • 2011
  • In this study, a standardized test method to analyze tensile properties of multi-directional GFRP plate was proposed. Presently, tensile strength test of FRP composite reinforced with isotropic and orthotropic fiber is standardized according to ISO standard. Also, even though many studies were performed on test method to analyze the dynamic properties, the properties of tensile strength for multi-directional GFRP plate were not clearly identified. Currently, the domestic test method in accordance with ASTM, which is applicable to unidirectional FRP plate, gave tensile test results greater than actual properties. Thus, in this study, GFRP tensile test was conducted using the method found to be commonly applicable to all standards based on literature review of domestic and international references. Then, anchorage length experiments were performed using the proposed tension test method to evaluate validity of the method. Finally, optimal anchorage length was estimated from the numerical analysis to propose the standardized tensile strength method for GFRP multi-directional composite evaluation.

Study on the Testing Method for Setting Time of Set Accelerating Agent Using Shotcrete by Gilmour Needles (길모어침에 의한 숏크리트용 급결제의 품질시험방법에 대한 고찰)

  • Kim, Chun Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.195-200
    • /
    • 2011
  • KS F 2782 (for shotcrete accelerators) standard cross-section of tunnel construction or repair is a reinforcement used in the field of shotcrete accelerators as a criterion in assessing shotcrete performance. Thus, KS F 2782 by standard accelerator will determine the nature of the product of concrete accelerators that will be used to record variations in the product roles, through determination of the quality of the experimental method to identify only the quality of the many variables that exist. This evaluation standard has so far distinguished accelerator products in indoor experiments that do not meet quality standards but were mostly for an on-site accelerator mixed with the shotcrete after being quite satisfied with the level of quality in a certain number of products. This observation is derived from the results of an indoor experiment considered to verify whether the site is suitable for indoor experiments, and whether its actual location in the city is relevant to the accelerator quality, to find a way to test if it fits. This study centers on the material conditions of the shotcrete accelerator and a variety of experimental results, and used the Gilmore needle to compare the compressive strength and KS F 2782 specification of the accelerator as a means to ensure product quality conformity analysis and for further research experiments. In conclusion, a portion of KS F 2782 standard that fixes the problems that can be resolved from the ground up as a whole is not a review for the domestic reality. As an indoor experiment to ensure uniformity in the field when applied in a sufficient correlation, complement must be in place.

Wi-Fi Directional Test Simplification for Smart Set-Top Box Based on Pair-Wise Testing (Pair-wise 기법을 활용한 스마트 셋톱박스 Wi-Fi 방향성 테스트의 간소화 방법)

  • Lee, Jae-Chul;Kim, Yoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.3
    • /
    • pp.1-8
    • /
    • 2015
  • The most used smart set-top box in home driven by the Android OS and based on Wi-Fi technology has to ensure nothing wrong with the Wi-Fi service regardless of the various user's installation environment. The direction test method about the nondirectional of the Wi-Fi doesn't be determined as the standard and each manufacturers devise the their own test methods and conduct the tests. In this paper, we created the 720 test cases considering 2 components of upload & download, the 10 elements of the vertical angle and the 36 elements of the horizontal angle looking at the wireless router in order to verify omni-directional Wi-Fi capability. In reality, from viewpoint in terms of cost and time constraint, it is difficult to test all the test cases. Therefore, we decided to reduce test cases by applying Pair-wise testing technique which is one of combinational testing techniques based on ISO / IEC 29119-4. And we obtained the test cases in which the Pair-wise technique was applied by Allpairs tool which output test cases automatically and conducted the test. It could be confirmed that the proposed technique shortened 48.61% of the time to be spent in progressing the existing test cases and that the trace about the part in which the problem was generated with the result of the simplified test case was possible enough.

A study on Communication Robustness Testing for Industrial Control Devices (산업용 제어기기의 통신 견고성 시험 방안 연구)

  • Park, Kyungmi;Shin, Donghoon;Kim, WooNyon;Kim, SinKyu
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.29 no.5
    • /
    • pp.1099-1116
    • /
    • 2019
  • Industrial control systems(ICS) are widely used in various industrial area and critical infrastructure. To mitigate security threats on ICS, the security assurance test for industrial control devices has been introduced and operating. The test includes testing of the security function of the device itself and testing of communication robustness. In this paper, we describe the security requirements of EDSA, Achilles, and Korea's TTA standard(security requirements for ICS). And also, we analyzed the characteristics of communication robustness test(CRT) of each certification. CRT verifies the device's operation of essential function while transmitting fuzzing and stress packets. Existing test methods are mostly focused on the embedded devices and are difficult to apply to various devices. We propose a method to test communication robustness which reflect the characteristics of control H/W, control S/W, field devices and network devices in ICS. In the future, we will apply the proposed communication robustness test to actual products and present solutions for arising issues.

Improvement of Performance Test Standards for Marine Pollution Prevention Materials and Chemicals (for Eco-toxicity Test) (해양오염방제 자재·약제의 성능시험기준 개선방안에 관한 연구(생태독성시험 항목))

  • Kim, Tae Won;Lee, Su Jin;Kim, Young Ryun;Lee, Moon Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.744-753
    • /
    • 2021
  • This study suggests ways to improve the standard test method and judgment criterion for the "Eco-toxicity Test" based on the rules and regulations provided in 'performance and qualifying test standards for marine pollution prevention materials and chemicals' in the Republic of Korea. Compared with the relevant references of other countries, this study attempted to find the limitations in the existing standards. As for the growth inhibition test of algae using Skeletonema costatum as an indicator, applying comparative analysis to measure specific growth rates, together with statistical analysis, instead of applying current methods, judged by the appearance of colors from the culture medium was suggested. Considering the exponential growth phase of the test species, the test duration was suggested to be reduced to less than four days. For the test with fish as an indicator, resetting the appropriate body size was suggested to, show consistent sensitivity against chenicals applied during testing. Furthermore, it is necessary to consider the criteria needs, which should be established in reasonable and objective ways. For the testing species, marine rotifer, Brachionus plicatilis could be a replacement for Artemia sp., and a bivalve for fish in the test. To improve the performance effectiveness of the "Eco-toxicity test", it is worth considering the designation of accredited testing institutes, by placing it in the same loop. Thus it is also expected to have a reliable management system in place, having the capacity of cost calculation properly and adjusting testing items if required.

A Study on The Application of ISO/IEC 17025 Software Accredited Testing Institute Using ISO/IEC/IEEE 29119 and ISO/IEC 25023 (ISO/IEC/IEEE 29119와 ISO/IEC 25023을 이용한 ISO/IEC 17025 소프트웨어 공인시험기관 적용에 관한 연구)

  • Lee, Chang-Hee;Kim, Yoon-Sook;Noh, A-Reum;Yang, Jung-Sim;Kim, Myung-Sup;Song, Sung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.97-106
    • /
    • 2020
  • The purpose of this study is to determine how to apply ISO/IEC/IEEE 29119 software test procedures and ISO/IEC 25023 software test evaluation items to software-accredited testing laboratories based on the ISO/IEC 17025 international standard requirements. As a method, the overall requirements for their application to a test laboratory were analyzed by mapping ISO/IEC/IEEE 29119 and ISO/IEC 25023 based on ISO/IEC 17025. According to the mapping analysis, a total of 29 documents were created, including quality manuals, procedures, and test guidelines for the operation of the test laboratory. As a result of the study, a test laboratory management system was developed using Confluence 6.15 software by applying the analyzed results of the overall requirements. The test procedures, documents, and records were stored in, and operated from, this system. Verification of suitability for operation of the test laboratory was conducted by KOLAS evaluators through a document review and an on-site audit at the LG Electronics SW Accredited Test Laboratory in Seoul. In conclusion, it was confirmed through the KOLAS evaluation that the test laboratory management system and the operation of the test laboratory are appropriate and, compared with previous cases, the test laboratory operates effectively, and the overall schedule of accreditation could be shortened.

Determination of Nitrogen Fertilizer Recommendation Rates Estimated by Soil-Testing for Different Types of Paddy Soils (토양검정에 의한 논토양 유형별 질소시비량 결정)

  • Moon, Young-Hun;Kwon, Young-Rip;Ahn, Byung-Koo;Lee, Jin-Ho;Choi, Dong-Chil
    • Korean Journal of Environmental Agriculture
    • /
    • v.29 no.1
    • /
    • pp.33-38
    • /
    • 2010
  • To improve the existing nitrogen recommendation method based on chemical properties of soils and to establish new recommendation rates of nitrogen fertilizer due to different types of soils, the application rates of nitrogen fertilizer were examined in different soils of 12 experimental rice paddy fields. The application rates of nitrogen fertilizer estimated by soil-testing were higher than the rates of nitrogen standard recommendation that has been used. The application rates for minimum rice productivity ranged from a low of 168 kg/10a in sandy soil to a high of 315 kg/10a in saline soil. Amounts of nitrogen absorption in rice were proportional to the application amounts of nitrogen fertilizer in soils. Nitrogen use efficiency was the highest, 36.7%, in immatured paddy field and it was inversely proportional to the application amounts of nitrogen. the rice tasty value was the highest in the soils without nitrogen application, and also it was the lowest in the saline soils with or without nitrogen application. As comparing with the nitrogen application rates obtained by the existing nitrogen recommendation method, optimal nitrogen application rates estimated by the standardization of nitrogen application efficiency rate, environmental index, and rice quality were 1.0 fold in the well adapted soil and sandy soil fields, 0.92 fold in the immatured soil field, and 0.83 fold in the saline soil field.

A Study on Utilizing Instrumented Indentation Technique for Evaluating In-field Integrity of Nuclear Structures (원전 구조물의 가동 중 건전성 평가를 위한 연속압입시험법의 활용에 관한 연구)

  • Song, Won-Seok;Kim, Seung-Gyu;Ahn, Hee-Jun;Kim, Kwang-Ho;Kwon, Dongil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.2
    • /
    • pp.165-172
    • /
    • 2013
  • Power generating unit structures are designed and built to meet standard to secure its safety for expected life time. As the structures have been exposed to combined environment, degradation of structure material is accelerated and it can cause unexpected damage; evaluating precise mechanical properties of weak site like welded area is an essential research area as it is directly connected to safety issues. Existing measuring technique like tensile test requires specific size in testing specimen yet it is destructive method which is hard to apply on running structures. To overcome above mentioned limitation, IIT is getting limelight as it is non-destructive and simple method. In this study, latest technique is introduced to evaluate tensile property and residual stress by analyzing stress field occurs under the indenter while IIT is performed. Test on welded area, the weak site of nuclear structures have been practiced and confirmed that IIT can be usefully applied to evaluate integrity in industry.

Improving the Accuracy of Early Diagnosis of Thyroid Nodule Type Based on the SCAD Method

  • Shahraki, Hadi Raeisi;Pourahmad, Saeedeh;Paydar, Shahram;Azad, Mohsen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.4
    • /
    • pp.1861-1864
    • /
    • 2016
  • Although early diagnosis of thyroid nodule type is very important, the diagnostic accuracy of standard tests is a challenging issue. We here aimed to find an optimal combination of factors to improve diagnostic accuracy for distinguishing malignant from benign thyroid nodules before surgery. In a prospective study from 2008 to 2012, 345 patients referred for thyroidectomy were enrolled. The sample size was split into a training set and testing set as a ratio of 7:3. The former was used for estimation and variable selection and obtaining a linear combination of factors. We utilized smoothly clipped absolute deviation (SCAD) logistic regression to achieve the sparse optimal combination of factors. To evaluate the performance of the estimated model in the testing set, a receiver operating characteristic (ROC) curve was utilized. The mean age of the examined patients (66 male and 279 female) was $40.9{\pm}13.4years$ (range 15- 90 years). Some 54.8% of the patients (24.3% male and 75.7% female) had benign and 45.2% (14% male and 86% female) malignant thyroid nodules. In addition to maximum diameters of nodules and lobes, their volumes were considered as related factors for malignancy prediction (a total of 16 factors). However, the SCAD method estimated the coefficients of 8 factors to be zero and eliminated them from the model. Hence a sparse model which combined the effects of 8 factors to distinguish malignant from benign thyroid nodules was generated. An optimal cut off point of the ROC curve for our estimated model was obtained (p=0.44) and the area under the curve (AUC) was equal to 77% (95% CI: 68%-85%). Sensitivity, specificity, positive predictive value and negative predictive values for this model were 70%, 72%, 71% and 76%, respectively. An increase of 10 percent and a greater accuracy rate in early diagnosis of thyroid nodule type by statistical methods (SCAD and ANN methods) compared with the results of FNA testing revealed that the statistical modeling methods are helpful in disease diagnosis. In addition, the factor ranking offered by these methods is valuable in the clinical context.

Automatic Detection of Foreign Body through Template Matching in Industrial CT Volume Data (산업용 CT 볼륨데이터에서 템플릿 매칭을 통한 이물질 자동 검출)

  • Ji, Hye-Rim;Hong, Helen
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.12
    • /
    • pp.1376-1384
    • /
    • 2013
  • In this paper, we propose an automaticdetection method of foreign bodies through template matching in industrial CT volume data. Our method is composed of three main steps. First,Indown-sampling data, the product region is separated from background after noise reduction and initial foreign-body candidates are extracted using mean and standard deviation of the product region. Then foreign-body candidates are extracted using K-means clustering. Second, the foreign body with different intensity of product region is detected using template matching. At this time, the template matching is performed by evaluating SSD orjoint entropy according to the size of detected foreign-body candidates. Third, to improve thedetection rate of foreign body in original volume data, final foreign bodiesare detected using percolation method. For the performance evaluation of our method, industrial CT volume data and simulation data are used. Then visual inspection and accuracy assessment are performed and processing time is measured. For accuracy assessment, density-based detection method is used as comparative method and Dice's coefficient is measured.