• Title/Summary/Keyword: standard testing method

Search Result 578, Processing Time 0.026 seconds

Investigation of the ASTM International frost heave testing method using a temperature-controllable cell

  • Hyunwoo, Jin;Jangguen, Lee;Byung-Hyun, Ryu
    • Geomechanics and Engineering
    • /
    • v.31 no.6
    • /
    • pp. 583-597
    • /
    • 2022
  • Frost heave can cause uneven ground uplift that may damage geo-infrastructure. To assist damage-prevention strategies, standard frost heave testing methods and frost susceptibility criteria have been established and used in various countries. ASTM International standard testing method is potentially the most useful standard, as abundant experimental data have been acquired through its use. ASTM International provides detailed recommendations, but the method is expensive and laborious because of the complex testing procedure requiring a freezing chamber. A simple frost heave testing method using a temperature-controllable cell has been proposed to overcome these difficulties, but it has not yet been established whether a temperature-controllable cell can adequately replace the ASTM International recommended apparatus. This paper reviews the applicability of the ASTM International testing method using the temperature-controllable cell. Freezing tests are compared using various soil mixtures with and without delivering blow to depress the freezing point (as recommended by ASTM International), and it is established that delivering blow does not affect heave rate, which is the key parameter in successful characterization of frost susceptibility. As the freezing temperature decreases, the duration of supercooling of pore water shortens or is eliminated; i.e., thermal shock with a sufficiently low freezing temperature can minimize or possibly eliminate supercooling.

A Study on Standard Testing Method for Type Approval of DSC Using MF/HF (MF/HF용 DSC의 형식검정을 위한 표준 시험방법)

  • 이동식;김기문
    • Journal of the Korean Institute of Navigation
    • /
    • v.19 no.4
    • /
    • pp.63-82
    • /
    • 1995
  • This paper is a study on standard testing method for type approval of DSC which is the main structure of the terrestrial communication. As authority inspecting offices and producers have no experience for type approval of relative equipments as adapting GMDSS. In this paper, it is to be improved the understanding for type approval ; a system, standard of technic and testing methods, etc and make better quality of relative equipments. Additionally it could help quality and quantity improvement in all radiocommunication parts. Of course, the regulation for type approval had made but most makers didn't know it correctly, so the method of solution have been studied. By result of this study, with comparision and analysis of structure and a condition of efficiency with adapting GMDSS is could help some problems slove in the field and gave testing method of machinery and tools, electrical conditions, came out measurement and did ways standard efficiency.

  • PDF

On the Application Plan Study of International Standard Tendency in Software Quality Testing (소프트웨어 품질 평가 국제 표준 적용 방안에 대한 연구)

  • Jung Hye-Jung
    • Journal of Internet Computing and Services
    • /
    • v.7 no.4
    • /
    • pp.1-10
    • /
    • 2006
  • We are studying international standard about the software quality evaluation. The software quality has been more important on users and developers. In this paper, first, we study international tendency of the inside and outside of the country in software quality evaluation for evaluating the software quality objectively and quantitatively, Second, we notify a new direction for software quality standard of inside and outside of country. Third, we study on the testing method of software reliability for making use of the software reliability growth model. Fourth, we spread method about standard of the software quality evaluation, fifth, we research into the international standard ISO/IEC 9126 and ISO/IEC 25000 series for evaluation of software quality testing, and we propose to the application plan of software quality testing.

  • PDF

Developing a Testing Method for Antimicrobial Efficacy on TiO2 Photocatalytic Products

  • Kim, Jee-Yeon;Park, Chang-Hun;Yoon, Je-Yong
    • Environmental Engineering Research
    • /
    • v.13 no.3
    • /
    • pp.136-140
    • /
    • 2008
  • $TiO_2$ photocatalyst has been known to exhibit a notable disinfecting activity against a broad spectrum of microorganisms. A lot of commercial $TiO_2$ photocatalyst products have been developed for antimicrobial purposes. However, a standard method has not yet been proposed for use in testing antimicrobial activity. In this study, we developed a $TiO_2$ photocatalytic adhesion test method with film as the standard testing method for the evaluation of antimicrobial activity. This method was devised by modifying the previous antimicrobial products test method, which has been widely used, and considering the characteristics of $TiO_2$ photocatalytic reaction. The apparatus for testing the antimicrobial activity was composed of a Black Light Blue (BLB) lamp as UV-A light source, a Petri dish as the cover material, and a polypropylene film as the adhesion film. The standard $TiO_2$ photocatalyst sample, Degussa P25 $TiO_2$ - coated glass, could only be used once. The optimal initial concentration of the microorganism, proper light intensity, and light irradiation time were determined to be $10^6$ CFU/mL, 1.0 mW/$cm^2$, and 3 hr, respectively, for testing and evaluating antimicrobial activity on the $TiO_2$ surface.

Standardization of Fracture Toughness Testing of Ceramics in the United States

  • Quinn, G.D.;Jenkins, M.J.;Salem, J.;Bar-On, I.
    • The Korean Journal of Ceramics
    • /
    • v.4 no.4
    • /
    • pp.311-322
    • /
    • 1998
  • American Society for Testing and Materials (ASTM) standard test method PS 070-97 has been created for measuring fracture toughness of advanced ceramics. PS 070-97 includes three test methods which use beams in bending: chevron notch (CNB), single-edged precracked beam (SEPB), and surface crack in flexure (SCF). Supporting data has been collected through several Versailles Advanced Materials and Standards round robins. This paper discusses the evolution of the standard including the rationale for the choice of the three methods and the specifications in the standard. Progress on Standard Reference material 2100 which will have certified values of fracture toughness is presented.

  • PDF

Combustion Property Analysis of Propellant using Standard Motor (표준모타를 이용한 추진제 연소특성 분석)

  • 박의용;최성한;황종선
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.181-184
    • /
    • 2003
  • We manufactured standard motor to measure burning rate of propellant, used to estimate burning rate of main motor by static fired testing. We installed static fired testing facility and developed standard motor more lightly to accomplish the test. As a result of the tests, we could get the burning rate closer than acquired by existing method to the main motor's on. And we confirmed repeatability by many times of tests. We will use this method positively for R&D and quality assurance activity of mass production.

  • PDF

The Study on Analytical Method of Lead, Cadmium and Chromium in Copper Metal by Matrix Matching Method of Inductively Coupled Plasma Atomic Emission Spectrometer (유도결합 플라즈마 발광분광기의 매트릭스 보정법에 의한 구리 중납, 카드뮴 및 크롬 분석에 관한 연구)

  • Joo, Sung-Kyun;Kim, Joon;cheong, Nam-Yong;Lim, Kyu-Chual;Choi, Young-Hwan;Kim, Sang-Kyung
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.3
    • /
    • pp.293-301
    • /
    • 2009
  • Analytical results of a fixed concentration of Pb, Cd and Cr in the synthetic copper standard solution (RMs) for using the matrix no matched standard calibration curve at various wavelength by ICP showed that accuracy (140 $\sim$ 1,070% in case of Pb) is very poor at all wavelengths because of the Cu matrix effect. Analytical results of a fixed concentration of Pb, Cd and Cr in the different concentration solutions of Cu showed that found values were on the increase or decrease as the rate of a regular equation as the concentration of Cu was increased. Accuracies by the Cu matching method in the analysis of Pb, Cd and Cr in the synthetic copper standard solution (RMs) were higher than 99.9%.

A Study on the Design of the rated insulation voltage of 690V for the low-voltage switchgear and controlgear (저압기기 정격절연전압 690V 개발시 고려사항에 대한 연구)

  • Kim, Myoung-Seok;Kim, Jong-Yeok;Park, Sang-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.961-963
    • /
    • 2000
  • Most of the application standard of the low-voltage devices have applied one the IEC standard another the UL standard. European union applied the IEC60947-1 standard has not exceed 1000V a.c. or 1500V d.c.. Therefore. it is necessary to the low-voltage device has expended for rated operational voltage with our products. The export of European market shall be made for the CE-Marking in accordance with IEC60947-1 ( Low-voltage switchgear and controlgear). We shall be considered for the requirement with the IEC standard. In this time to study for power supply system at EU ( European union. At that time for design and development in order to the construction and test method among the study for the rated insulation voltage at less then 690V.

  • PDF

The Software Quality Testing on the basis of the International Standard ISO/IEC 25023 (국제표준 ISO/IEC 25023 을 기반으로 한 소프트웨어 품질평가)

  • Jung, Hye-Jung
    • Journal of the Korea Convergence Society
    • /
    • v.7 no.6
    • /
    • pp.35-41
    • /
    • 2016
  • As software is very important, modern men are interesting software quality testing. In this paper, we analyze the Internation standard and Test data, so, we propose the testing method by analysing testing data. We compare ISO/IEC 9126-2 testing model with ISO/IEC 25023 testing model. On the basis of ISO/IEC 25023, we classify the test data and we analyze the difference of International Standard to functionality, reliability, usability, efficiency, maintainability, portability, compatability, and security. By reality 331 testing data, we classify test data, and analyze difference according to sex. We find regression model by functionality, usability and testing date and we prove difference of testing date and the number of error by tester. Also, we prove difference of the number of error in software type.

Temperature Distribution Monitoring of Transformer Using IRR-Camera (적외선방사카메라를 이용한 변압기 온도분포 모니터링)

  • 이우선;정찬문;서용진
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07a
    • /
    • pp.459-462
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of Power transformer is measured with partial temperature distribution in real time.

  • PDF