• Title/Summary/Keyword: standard specimen

Search Result 690, Processing Time 0.029 seconds

Fatigue-characteristic Evaluation of a Ventilating Blade in the Air-conditioner (냉방기용 송풍 Blade의 피로특성 평가)

  • Choi, Jung-Hun;Koo, Jae-Mean;Seok, Chang-Sung;Kim, Jong-Hak;Chang, Sung-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.11
    • /
    • pp.72-77
    • /
    • 2010
  • The fatigue characteristic of a material or a structure is derived from fatigue tests of standard specimens. However, many test results of standard specimens are very different from those of real structures. One reason for this difference is the constraint effects according to the geometrical difference. Therefore, to calculate more accurate fatigue life, the constraint effect must be considered by comparing test results of standard specimens with those of real structures. In this study, a blade of an air-conditioner was evaluated by both the test and the analysis. The results showed that a standard specimen is conservative, compared with a structure specimen. And fatigue life of an air-conditioner's blade was predicted from those.

The effect of short and long duration sintering method on microstructure and flexural strength of zirconia (단시간과 장시간의 소결방법에 따른 지르코니아의 굴곡 강도와 미세구조의 변화)

  • Lee, Ha-Bin;Lee, Tae-Hee;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.42 no.2
    • /
    • pp.73-79
    • /
    • 2020
  • Purpose: The aim of this study was to investigate the influence of short and long duration sintering on microstructure and flexural strength of zirconia. Methods: To conduct three-point bending test, Zirconia specimens are milled according to ISO 6872 guidelines(N=18, n=9 per group). Two specimens group(n=8) is sintered for 10 hours(Standard schedule) and 3 hours(Speed schedule) at the peak temperature of 1550℃ with silicon carbide sintering furnace. Flexural strength of specimens are measured by instron. After coating each specimen(n=1), microstructure of specimens is observed using Scanning Electron Microscope(SEM). T-test was utilized to statistically assess the data. Results: The mean and standard deviation value of the flexural strength for standard schedule group are 578.15±57.48Mpa, that of speed schedule are 465.9±62.34Mpa. T-test showed significant differences in flexural strength between two zirconia specimen group which applied standard schedule and speed schedule respectively(p<0.05). Conclusion: The result of this study showed that the increase in sintering time led to increased grain size, and also to a positive effect on the flexural strength.

Analysis of Cleavage Fracture Toughness of PCVN Specimens Based on a Scaling Model (PCVN 시편 파괴인성의 균열 깊이 영향에 대한 Scaling 모델 해석)

  • Park, Sang-Yun;Lee, Ho-Jin;Lee, Bong-Sang
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.4
    • /
    • pp.409-416
    • /
    • 2009
  • Standard procedures for a fracture toughness testing require very severe restrictions for the specimen geometry to eliminate a size effect on the measured properties. Therefore, the used standard fracture toughness data results in the integrity assessment being irrationally conservative. However, a realistic fracture in general structures, such as in nuclear power plants, may develop under the low constraint condition of a large scale yielding with a shallow surface crack. In this paper, cleavage fracture toughness tests have been made on side-grooved PCVN (precracked charpy V-notch) type specimens (10 by 10 by 55 mm) with various crack depths. The constraint effects on the crack depth ratios were evaluated quantitatively by the developed scaling method using the 3-D finite element method. After the fracture toughness correction from scaling model, the statistical size effects were also corrected according to the standard ASTM E 1921 procedure. The results were evaluated through a comparison with the $T_0$ of the standard CT specimen. The corrected $T_0$ for all of the PCVN specimens showed a good agreement to within $5.4^{\circ}C$ regardless of the crack depth, while the averaged PCVN $T_0$ was $13.4^{\circ}C$ higher than the real CT test results.

Design of Injection Mold with Cavity Pressure/Temperature Sensors and Molding for Standard Tensile Test Specimen (내압력.온도센서를 갖는 표준 인장시편용 사출금형설계 및 성형)

  • Lee D.M.;Han B.K.;Lee O.S.;Lee Sung-Hee
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1416-1419
    • /
    • 2005
  • Design and manufacturing of plastic injection mold with cavity pressure/temperature sensors were performed in the present study for tensile test specimen. Standards of mold-base and tensile test specimen were used to design an injection molding system. Cavity pressure and temperature sensors were placed on the side of fixed platen of injection mold machine to prevent them from external impact damage. Injection molding experiments with variations of injection speed and melt temperature were performed and polycarbonate tensile specimens were prepared for the tensile test. It was shown that injection molding processing parameters can have effect on the mechanical properties of the plastic injection molded part.

  • PDF

Fracture toughness and AE Characteristics of Engineering plastic according to thickness (두께변화에 따른 엔지니어링 플라스틱의 파괴인성과 AE특성)

  • 남기우;김선진;안병현
    • Journal of Ocean Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.51-57
    • /
    • 1996
  • A standard method for the evalution of the fracture toughness of the high polymer materials has not been fully developed in comparison with that for metallic materials, and has not yet established. In this paper, fracture toughness tests using polycarbonate specimens were carried out. The fracture thughness tests using polycabonate specimens were carried out. The fracture toughness of commercial polycarbonate were dependent on the specimen thickness. The specimen thickness is necessary above 8mm to obtain the valid $K_{IC}$. A cumulative counts were slightly dependent on specimen thickness.

  • PDF

Environmental Specimen Bank and Ecosystem Assessment

  • Kim, Myungjin;Kim, Jiyeon;Cho, Yongjoo;Yoo, Byungho
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.6
    • /
    • pp.429-434
    • /
    • 2009
  • Environmental specimen bank (ESB) is a new tool to assess ecosystem in environmental impact assessment (EIA). ESB looks at changes in the concentration of pollutants in human and environmental specimens over long periods of time through retrospective analysis of archived samples. Korea started to design its National Environmental Specimen Bank (NESB) in 2007 and planned to launch an operational pilot project by 2010. NESB prepares five Standard Operating Procedures (SOPs) of shoots of Red and Korean pine, leaves of Mongolian oak, Pigeon's egg, and Common carp's muscle out of 14 planned specimens in 2009. ESB contributes to monitoring the effectiveness of EIA projects and policies by providing a time capsule through ecosystem assessment of representative species. This study reviews ecosystem assessment in EIA and the ESB establishment in Korea and probes NESB applications in ecosystem assessment.

Deformation Characteristics of Miniature Tensile Specimens of a SA 508 C1.3 Reactor Pressure Vessel Steel

  • Byun, Thak-Sang;Chi, Se-Hwan;Hong, Jun-Hwa;Jeong, Ill-Seok;Hong, Sung-Yull
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.182-187
    • /
    • 1996
  • Deformation characteristics of miniature plate tensile specimens have been studied to develop the thickness requirement and a correlation to estimate the mechanical properties of bulk material from miniature specimen data. The material used was a SA 508 C1.3 reactor pressure vessel steel and the thicknesses of miniature tensile specimens varied from ().12 m to 2 mm. The effects of thickness on the tensile deformation properties such as strength, ductility, and necking characteristics were analyzed. The yield and ultimate tensile strengths were independent of specimen thickness when the thickness was larger than about 0.2 mm. The uniform and total elongations decreased as the specimen thickness decreased. It was also observed that the uniform strain component in the width direction decreased with decrease in the specimen thickness, however, that in the thickness direction was rather constant in total thickness range studied. Based on this observation and a relationship between the necking angle and the ratio between strain components, a correlation between the uniform elongations of miniature specimen and standard specimen was derived. The uniform elongations calculated by this new correlation agreed well with the measured values.

  • PDF

Experimental Method to Evaluate Stress Triaxiality near the Crack Tip;Applicability to Various Specimen Configurations (균열선단 응력삼축성의 측정방법;여러 형상 시험편에의 적용성 검토)

  • Kim, Dong-Hak;Kim, Do-Hyung;Kang, Ki-Ju
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.60-65
    • /
    • 2004
  • Kim et al. described and compared other methods of measuring stress triaxiality using the displacements near the side necking, proved the validities of these models and explored the effect of location where the displacements are measured using three-dimensional finite element analysis for a standard CT specimen with 20% side-grooves. In this paper, the applicability of these models to various specimen and materials are examined in detail. To consider the effects of side groove, thickness of specimen, crack length, specimen geometry and strain hardening exponents, three-dimensional finite element simulation has been performed for various specimen geometries. For a case without a side groove, in the whole the difference between the stress triaxilaity analytically evaluated and directly determined is similar. For a case with a 20% side groove the stress triaxiality is measured at the area where ${\theta}$ is smaller than $60^{\circ}$, which excludes a side grooved area.

  • PDF

A Study on the Method of Transferring Metal Specimens for Real-time Transmission Electron Microscopy using Ultrasonic Treatment (초음파 처리 활용 실시간 투과전자현미경 관찰용 금속 시편 전사 방법에 관한 연구)

  • H. Kim
    • Transactions of Materials Processing
    • /
    • v.33 no.2
    • /
    • pp.118-122
    • /
    • 2024
  • Micro-electromechanical systems (MEMS) based in-situ heating holders have been developed to enable high resolution imaging of heat treatment analysis. However, unlike the standard 3 mm metal disk specimens used in the furnace-based heating holder and general transmission electron microscopy holder, the MEMS-based in-situ heating holder requires thin specimens that can be penetrated by electrons to be transferred onto the MEMS chip. Previously, focused ion beam milling was used to transfer metal specimens, but it has the disadvantage of being expensive and the risk of specimen damage due to gallium ions. Therefore, in this study, we devised a method of transferring metallic materials by ultrasonic treatment using a transmission electron microscopy specimen made by electro jet polishing. A 3mm electropolished metal disk was placed in an appropriate solution, ultrasonicated, and then drop casted. The transfer of the specimen was successful, but it was confirmed that dislocations were formed inside the specimen due to ultrasonic treatment. This study provides a novel method for transferring metallic materials onto MEMS chips, which is cost-effective and less gallium ion damaging to the specimen. The results of this study can be used to improve the efficiency of heat treatment analysis using MEMS-based in-situ heating holders.

Estimation of Fracture Resistance Curves of Nuclear Materials Using Small Punch Specimen (소형펀치 시편을 이용한 원자력 재료의 파괴저항곡선 예측)

  • Chang, Yoon-Suk;Kim, Jong-Min;Choi, Jae-Boong;Kim, Min-Chul;Lee, Bong-Sang;Kim, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.1 s.256
    • /
    • pp.70-76
    • /
    • 2007
  • Elastic-plastic fracture mechanics is popularly used for integrity evaluation of major components, however, it is not easy to extract standard specimens from operating facility. This paper examines how ductile fracture toughness is characterized by a small punch testing technique in conjunction with finite element analyses incorporating a damage model. At first, micro-mechanical parameters constituting Rousselier model are calibrated for typical nuclear materials using both estimated and experimental load-displacement (P-$\delta$) curves of miniaturized specimens. Then, fracture resistance (J-R) curves of relatively larger standard CT specimens are predicted by finite element analyses employing the calibrated parameters and compared with corresponding experimental ones. It was proven that estimated results by the proposed method using small punch specimen is promising and might be used as a useful tool for ductile crack growth evaluation.