• Title/Summary/Keyword: standard sample

Search Result 2,195, Processing Time 0.028 seconds

Effect of Bias on the Pearson Chi-squared Test for Two Population Homogeneity Test

  • Heo, Sunyeong
    • Journal of Integrative Natural Science
    • /
    • v.5 no.4
    • /
    • pp.241-245
    • /
    • 2012
  • Categorical data collected based on complex sample design is not proper for the standard Pearson multinomial-based chi-squared test because the observations are not independent and identically distributed. This study investigates effects of bias of point estimator of population proportion and its variance estimator to the standard Pearson chi-squared test statistics when the sample is collected based on complex sampling scheme. This study examines the effect under two population homogeneity test. The standard Pearson test statistic can be partitioned into two parts; the first part is the weighted sum of ${\chi}^2_1$ with eigenvalues of design matrix as their weights, and the additional second part which is added due to the biases of the point estimator and its variance estimator. Our empirical analysis shows that even though the bias of point estimator is small, Pearson test statistic is very much inflated due to underestimate the variance of point estimator. In the connection of design-based variance estimator and its design matrix, the bigger the average of eigenvalues of design matrix is, the larger relative size of which the first component part to Pearson test statistic is taking.

Studies on the Quality Control of Insulin Radioimnunoassay Kit (I) -Pitfalls in Radioimmunoassay of Insulin-

  • Lee, Kyung-Hee;Awh, Ok-Doo;Kim, Jae-Rok
    • Nuclear Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.223-229
    • /
    • 1978
  • A typical abnormal standard dose response curve of nearly convex form. often encountered in insulin radioimmunoassay (IRIA) has been analyzed by varying incubation conditions. The cause of such abnormality has been turned out to be the results of an incomplete equilibrium between the two reactants. By careful control of the temperature of serum sample an immediate cause of sharp deviation of B/F value of tile sample tube from the measurable range in the standard curve has also been investigated. The two main troubles have been proven to be stemed from incubation conditions. Incubation at 4$^{\circ}C$ for 48 hrs is emphasized for IRIA.

  • PDF

Developing a Korean Standard Speech DB (한국인 표준 음성 DB 구축)

  • Shin, Jiyoung;Jang, Hyejin;Kang, Younmin;Kim, Kyung-Wha
    • Phonetics and Speech Sciences
    • /
    • v.7 no.1
    • /
    • pp.139-150
    • /
    • 2015
  • The data accumulated in this database will be used to develop a speaker identification system. This may also be applied towards, but not limited to, fields of phonetic studies, sociolinguistics, and language pathology. We plan to supplement the large-scale speech corpus next year, in terms of research methodology and content, to better answer the needs of diverse fields. The purpose of this study is to develop a speech corpus for standard Korean speech. For the samples to viably represent the state of spoken Korean, demographic factors were considered to modulate a balanced spread of age, gender, and dialects. Nine separate regional dialects were categorized, and five age groups were established from individuals in their 20s to 60s. A speech-sample collection protocol was developed for the purpose of this study where each speaker performs five tasks: two reading tasks, two semi-spontaneous speech tasks, and one spontaneous speech task. This particular configuration of sample data collection accommodates gathering of rich and well-balanced speech-samples across various speech types, and is expected to improve the utility of the speech corpus developed in this study. Samples from 639 individuals were collected using the protocol. Speech samples were collected also from other sources, for a combined total of samples from 1,012 individuals.

Liquid Chromatography-Tandem Mass Spectrometry for the Determination of Lithospermic Acid B in Rat Serum

  • Kim, Hui-Hyun;Ji, Hye-Young;Lee, Hye-Won;Kim, Youn-Chul;Sohn, Dong-Hwan;Lee , Hye-Suk
    • Archives of Pharmacal Research
    • /
    • v.27 no.12
    • /
    • pp.1202-1206
    • /
    • 2004
  • A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/ MS) method for the determination of lithospermic acid B (LSB) in rat serum was developed. LSB and internal standard, 7-hydroxy-3-phenyl-chromen-4-one (HPC) were extracted from rat serum with methyl-tert-butyl ether at acidic pH and analyzed on a Luna $C_8$ column with the mobile phase of acetonitrile-ammonium formate (10 mM, pH 6.5) (50:50, v/v). The analytes were detected using a negative electrospray ionization tandem mass spectrometry in the multiple- reaction-monitoring mode. The standard curve was linear $(r^2 = 0.997)$ over the concentration range of 10.0-500 ng/mL. The coefficient of variation and relative error for intra- and interassay at three QC levels were 1.1~6.2% and -10.3~-2.7%, respectively. The recovery of LSB from serum sample ranged from 73.2 to 79.5%, with that of HPC (internal standard) being 75.1 %. The lower limit of quantification for LSB was 10 ng/mL using 50 ${\mu}L$ of serum sample.

A Comparative Study on Quantifying Uncertainty of Vitamin A Determination in Infant Formula by HPLC (HPLC에 의한 조제분유 중 비타민 A 함량 분석의 측정불확도 비교산정)

  • Lee, Hong-Min;Kwak, Byung-Man;Ahn, Jang-Hyuk;Jeon, Tae-Hong
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.152-159
    • /
    • 2008
  • The purpose of this study was to determine the accurate quantification of vitamin A in infant formula by comparing two different standard stock solutions as well as various sample weights using high performance liquid chromatography. The sources of uncertainty in measurement, such as sample weight, final smaple vloume, and the instrumental results, were identified and used as parameters to determine the combined standard uncertainty based on GUM(guide to the expression of uncertainty in measurement) and the Draft EURACHEM/CITAC Guide. The uncertainty components in measuring were identified as standard weight, purity, molecular weight, dilution of the standard solution, calibration curve, recovery, reproducibility, sample weight, and final sample volume. Each uncertainty component was evaluated for type A and type B and included to calculate the combined uncertainty. The analytical results and combined standard uncertainties of vitamin A according to the two different methods of stock solution preparation were 627 ${\pm}$ 33 ${\mu}$g R.E./100 g for 1,000 mg/L of stock solution, and 627 ${\pm}$ 49 ${\mu}$g R.E./100 g for 100 mg/L of stock solution. The analytical results and combined standard uncertainties of vitamin A according to the various sample weighs were 622 ${\pm}$ 48 ${\mu}$g R.E./100 g, 627 ${\pm}$ 33 ${\mu}$g R.E./100 g, and 491 ${\pm}$ 23 ${\mu}$g R.E./100 g for 1 g, 2 g, and 5 g of sampling, respectively. These data indicate that the preparation method of standard stock solution and the smaple amount were main sources of uncertainty in the analysis results for vitamin A. Preparing 1,000 mg/L of stock solution for standard material sampling rather than 100 mg, and sampling not more than 2 g of infant formula, would be effective for reducing differences in the results as well as uncertainty.

Design of an Ultra-Compact UHF Passive RFID Tag Antenna for a Medical Sample Tube

  • Lee, Jung-Nam;Hwang, Moon-Young;Lee, Sang-Il;Lee, Kwang-Chun;Park, Jong-Kweon
    • ETRI Journal
    • /
    • v.34 no.6
    • /
    • pp.974-977
    • /
    • 2012
  • In this letter, a small-sized ultra-high frequency (UHF) RFID tag antenna for a medical sample tube is proposed. The RFID tag antenna is designed and fabricated based on the circular loop antenna used in the UHF band (Korea standard, 917 MHz to 923.5 MHz). The tag antenna size is reduced using a circular meander stub. The antenna has a physical size of 8 mm, which is about ${\lambda}$/40 in electrical length. The proposed tag antenna is molded into a medical sample and multitag identification is performed.

A Topological Analysis of Large Scale Structure Using the CMASS Sample of SDSS-III

  • Choi, Yun-Young;Kim, Juhan;Kim, Sungsoo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.56.2-56.2
    • /
    • 2013
  • We study the three-dimensional genus topology of large-scale structure using the CMASS Data Release 11 sample of the SDSS-III Baryon Oscillation Spectroscopic Survey (BOSS). The CMASS sample yields a genus curve that is characteristic of one produced by Gaussian random-phase initial conditions. The data thus supports the standard model of inflation where random quantum fluctuations in the early universe produced Gaussian random-phase initial conditions. Modest deviations in the observed genus from random phase are as expected from the nonlinear evolution of structure. We construct mock SDSS CMASS surveys along the past light cone from the Horizon Run 3 (HR3) N-body simulations, where gravitationally bound dark matter subhalos are identified as the sites of galaxy formation. We study the genus topology of the HR3 mock surveys with the same geometry and sampling density as the observational sample, and the observed genus topology to be consistent with LCDM as simulated by the HR3 mock samples.

  • PDF

A Heuristic Methodology for Fault Diagnosis using Statistical Patterns

  • Kwon, Young-il;Song, Suh-ill
    • Journal of Korean Society for Quality Management
    • /
    • v.21 no.2
    • /
    • pp.17-26
    • /
    • 1993
  • Process fault diagnosis is a complicated matter because quality control problems can result from a variety of causes. These causes include problems with electrical components, mechanical components, human errors, job justification errors, and air conditioning influences. In order to make the system run smoothly with minimum delay, it is necessary to suggest heuristic remedies for the detected faults. Hence, this paper describes a heuristic methodology of fault diagnosis that is performed using statistical patterns generated by quality characteristics The proposed methodology is described briefly as follows: If a sample pattern generated by random variables is similar to the number of prototype patterns, the sample pattern may be matched by any prototype pattern among them to be resembled. This concept is based on the similarity between a sample pattern and the matched prototype pattern. The similarity is calculated as the weighted average of squared deviation, which is expressed as the difference between the relative values of standard normal distribution to be transformed by the observed values of quality characteristics in a sample pattern and the critical values of the corresponding ones in a matched prototype pattern.

  • PDF

A Dielectric Constant Measurement Method of Unprepared Samples (비가공 물질의 유전 상수 측정 방법)

  • Lee, Won-Hui
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.10
    • /
    • pp.896-900
    • /
    • 2008
  • A measurement method of the dielectric constant of materials whose standard sample is not prepared easily is proposed. The unprepared sample of the material is placed in a cavity, and the resonant frequency is measured. A commercial software simulates the same sample and the cavity leading to find the correct dielectric constant. The measured samples include a ceramic, a forced glass, and a powdered enamel. The measured dielectric constant of a ceramic, a forced glass, and a powdered enamel are 11-j0.0033(${\epsilon}_{\gamma}=11,\;tan{\delta}=0.0003$), 4.15-j0.053(${\epsilon}_{\gamma}=4.15,\;tan{\delta}=0.0128$), and 3.9-j0.042(${\epsilon}_{\gamma}=3.9,\;tan{\delta}=0.0108$) respectively.