• 제목/요약/키워드: standard of diagnosis

검색결과 1,198건 처리시간 0.029초

광역상수도 실측자료를 활용한 유속계수 평가 및 특성 분석 (Evaluation and Analysis of Characteristics for Hazen-Williams C Based on Measured Data in Multi-Regional Water Supply Systems)

  • 김범준;최명원;김길호;김형수
    • 상하수도학회지
    • /
    • 제30권2호
    • /
    • pp.197-206
    • /
    • 2016
  • Although the Hazen-Williams C factors are very important in the design, operation, and maintenance of water supply pipes, sufficient studies for them have been not reported in korea, which are based on experiments or measured data. Because of this, we have estimated C factors by measurement considering constraints in time precise safety diagnosis for multi-regional water supply system were performed. In this study, we confirmed constraints and variables characteristics of Hazen-Williams equation, and collected reliable C factors data of 174 by measurement, and analyzed their characteristics. According to collected data, the average value is 115.35, which is almost equal to the value of design standard or a little higher than it in korea. Also, among the equations suggested to determine C factor in the past, the C factors calculated by Sharp and Walski equation was closest to them in this study. In addition, to analyze collected C factors, use year and pipe diameter having high correlation with them were respectively divided into there categories. Analysis results showed that C factors evidently decreases depending on increases in use year, on the other hand, size of pipe diameter is proportional to value of them. In conclusion, this research showing evaluation and characteristics for C factors based on measured data will be used as practical reference in determining C factor in multi-regional water supply systems at a later date.

가정용 열펌프 시스템의 정상냉방 운전조건에서 기준모델에 의한 잔차의 통계적 분석 (Statistical Analysis on Residuals from No-Fault Reference Models of a Residential Heat Pump System in Normal Cooling Operation)

  • 김민성;윤석호;백영진
    • 대한기계학회논문집B
    • /
    • 제35권12호
    • /
    • pp.1351-1358
    • /
    • 2011
  • 열펌프의 고장감지 및 진단을 위하여 측정값에 대한 분석은 필수적이다. 열펌프의 고장감지는 열전대 등의 온도센서로 수행되는데, 재연성과 센서자체의 오차에 의해 시스템의 정상상태 측정값들은 통상 백색 노이즈의 형태로 존재한다. 고장감지 및 진단시스템을 구축하기 위하여 이상적인 정상상태를 정의하는 기준모델을 추출하게 되는데, 실제 측정값과 모델에 의한 기대값은 수학적 편차, 즉 잔차가 필연적으로 존재하게 된다. 이러한 잔차는 운전조건에 따라 변화하며, 다양한 불확실도를 포함한 확률분포를 갖게 된다. 본 연구에서는 온도센서를 활용하여 정상상태 진단을 수행하고 이를 기반으로 기준모델을 도출하였다. 이후 실측값과 기준모델과의 잔차를 통계적으로 분석하여 고장여부를 판단하는 경계값을 산출하였다. 본 분석에 의하여 열펌프의 고장감지 및 진단시스템의 개발을 위한 불확실도와 경계값을 통계적으로 계산함으로써 진단결과의 확률적 신뢰성을 보장할 수 있는 방법론을 제공하였다.

PACS환경에서 Full Field Digital Mammography 영상의 압축 화질평가에 관한 연구 (The Research on Compression Image Quality of Full Field Digital Mammography on PACS Environment)

  • 정재호;김은수
    • 한국방사선학회논문지
    • /
    • 제8권4호
    • /
    • pp.147-153
    • /
    • 2014
  • 디지털 Mammography영상에서 압축률에 따른 화질의 특성에 대해 정량적 평가와 정성적평가를 실시하였다. ACR Accreditation phantom을 대상으로 JPEG2000, JPEG 압축알고리즘을 적용하여 압축한 후 Detection Score를 측정하여 압축률에 상관없이 10점 인정기준을 충족하였다. 또한 실제미세병소 영상을 선정하여 압축을 실시하여 확대율에 따른 진단능의 변화를 측정하여 20:1 이상 압축 후 50% 이상 확대 시 진단능에 영향을 미칠 수 있음을 알 수 있었다. 또한, 정량적 평가방법인 PSNR, RMSE, MAE, SSIM등을 측정하여 압축률에 따른 원본영상과의 차이점은 비교적 허용 가능한 오차범위 내의 값이 측정되었다. 또한 MTF 측정을 통해 Full Field Digital Mammography 영상의 화질이 진단에 적합한 영상임을 알 수 있었다.

미만성 간질성 폐질환에서 비디오 흉강경을 이용한 폐생검 (Thoracoscopic Lung Biopsy for Diffuse Interstitial Lung Disease)

  • 심성보;연성모
    • Journal of Chest Surgery
    • /
    • 제29권7호
    • /
    • pp.741-746
    • /
    • 1996
  • 다양한 형태로 나타나는 미만성간질성폐질환을 진단하기 위하여는 임상소견, 기관지폐포 세척액검 사, 경기관지 생검 그리고 폐생검 등이 사용되고 있다. 미만성간질성폐질환의 확진을 위한 폐생검에서, 고전적인 개흥적 폐생검에 비해 흥강경을 이용한 폐생검이 흥강 내부의 세밀한 관찰로 적절한 위치의 병변을 채 취할 수 있고, 시술후 수술부위의 통증을 감소시킨다는 등의 장점이 있다. 가톨릭의과대학 흉부외과학 교실에서는 199)년 1월부터 1994년 6월까지 미만성간질성폐질환 환자 20 예에서 흥강경을 이용한 폐생검을 실시하였다. 남녀의 성비는 같았으며, 연령분포는 18세부터 69세 까 지로(평균 연령 48.5세), 50대가 6예로 가장 많았으며, 60대와 40대가 각각 4예씩으로 그 다음이었다. 생 검 부위는 좌하엽이 9예(45%)로 가장 많았으며,우하엽이 7예(35%)로 대부분 양하엽에서 채취되었다 생검 결과는 UIP 가 8예(40%)로 가장 많았고, 속립성 결핵이 4예(20%)로 그 다음이 었으며, 모두 20예에 서 10가지의 서로 다른 진단명이 나왔다. 수술중 개흥술로 전환한 예는 없었으며, 흉관의 제거에는 평균 3.2일이 소요되 었다. 술후 합병증이 발생하거나 潁좡\ulcorner예는 없었다.

  • PDF

안면중앙부 골절 진단시 전산화단층사진과 Waters 방사선사진의 진단능 비교 (A COMPARISON OF THE DIAGNOSTIC ABILITY BETWEEN WATERS′ RADIOGRAPH AND COMPUTED TOMOGRAPHY IN THE DIAGNOSIS OF MIDFACIAL FRACTURE)

  • 전인성;최순철
    • 치과방사선
    • /
    • 제27권1호
    • /
    • pp.179-188
    • /
    • 1997
  • This study was intended to compare the diagnostic ability between Waters' radiograph and CT in the diagnosis of midfacial fracture. The study group included 44 patients(male:32, female :12, age range :16-74 years old) with facial injury who underwent surgery. Waters' radiograph and both axial and coronal scanning were performed before surgery. Three oral radiologists and three non-oral radiologist interpreted 44 Waters' radiographs and 88 CT in three ways; 1) interpretation using Waters' radiograph only, 2) interpretation using CT only, 3) interpretation using Waters' radiograph and CT. The interpretation sites were confined to the walls of maxillary sinus; anterior, posterior, medial, lateral and superior wall. ROC curves were made with the findings during surgery as a gold standard except the posterior wall, where the joint evaluation of Waters' radiograph and CT by other three oral radiologists was used. ROC areas were compared according to the interpreting methods, the interpretation sites, and groups (R group ; oral radiologist group, N group ; non-oral radiologist group). The obtained results were as followed : 1. The diagnostic ability of CT only and Waters' radiograph and CT was higher than Waters' radiograph only in both groups(P<0.05). But there was no difference between CT only and Waters' radiograph and CT. 2. Generally, the diagnostic ability for the lateral antral wall was the highest and that for the posterior antral wall was the lowest in both groups(P<0.05). 3. In R group, for the anterior antral wall the diagnostic ability using CT only was increased but for the medial, lateral and superior antral walls the diagnostic ability was increased in only using Waters' radiograph and CT. 4. In N group, for the anterior and medial walls the diagnostic ability using CT only was increased. But for the posterior, lateral and superior antral walls there were no difference among three interpreting methods. 5. The diagnostic ability of R group was higher than N group in all interpreting methods.

  • PDF

흉강경을 이용한 하행 괴사성 종격동염의 치료 (Management of Descending Necrotizing Mediastinitis with Thoracoscopy)

  • 이성호;선경;김광택
    • Journal of Chest Surgery
    • /
    • 제35권2호
    • /
    • pp.161-165
    • /
    • 2002
  • 하행 괴사성 종격동염은 대부분 경부 부위의 농양으로 시작하여 종격동으로 파급되는 매우 치명적인 질환이며 저자에 따라 25∼40%의 사망률을 보고하고 있다. 빠른 진단과 적절한 수술적 치료가 중요하며 수술적 치료의 방법에는 아직 여러 가지 방법들이 보고되고 있지만 농양의 완전한 배농이 특히 중요하다고 보고하고 있다. 배농술은 경부 절개를 통한 배농과 함께 흉부 내의 종격동 배농술이 필요하며 종격동 배농술은 대부분 개흉술을 통하여 시행되어 왔으나 개흉술에 따른 합병증과 수술부위의 감염 등이 술후 이환율을 증가시키는 원인이 될 수 있다. 반면에 흥강경을 이용한 배농은 경부 배농술 및 흉부 배농술을 동시에 시행할 수 있으며 좋은 수술시야를 보여주고 술후 환자의 회복이 빨라 하행 괴사성 종격동염의 좋은 치료 방법이라 생각된다.

확률 기반의 신뢰도를 이용한 비파괴 압축강도 추정식 평가 (The Evaluation of Non-Destructive Formulas on Compressive Strength Using the Reliability Based on Probability)

  • 박진우;추진호;박광림;황인백;신용석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권4호
    • /
    • pp.25-34
    • /
    • 2015
  • 정밀안전진단시 콘크리트 강도를 추정하기 위한 방법으로 강도추정식을 이용한 방법이 많이 사용되며, 이용되는 추정식은 외국에서 이미 제안된 식이 대부분이고, 적용되는 추정식에 따라서 추정강도의 차이가 심하게 발생하며, 전반적으로 강도추정의 신뢰도가 낮아져 정밀 안전진단 결과의 신뢰성에도 상당한 영향을 미친다. 이런 문제점은 일부 국한된 부분에서 발생하게 되어 다수의 실험을 통하여 신뢰도를 높일 수 있다. 본 논문은 이와 같은 필요성을 포괄하기 위해 실내압축강도와 관련된 신뢰도 평가식을 제안하였다. 확률론적 기법을 이용하여 신뢰도 평가식의 유용성을 검증하였으며 실내압축강도와 추정압축강도의 추이 그래프를 비교하였다. 비교결과, 본 연구에서 제시된 신뢰도 평가식의 유용성을 확인하였다.

딜의 수경재배에 적합한 배양액 개발 (Development of Optimum Nutrient Solution for Dill (Anethum graveolens L.) in Hydroponics)

  • 여경환;이용범
    • 생물환경조절학회지
    • /
    • 제6권4호
    • /
    • pp.299-309
    • /
    • 1997
  • 본 실험은 수경재배에서 딜의 양수분 흡수 패턴을 밝히고 생육과 환경특성에 적합한 배양액을 개발하여 실제 재배에 응용하고자 수행하였다. 이를 위해 딜의 양분 홉수율에 의한 배양액을 조성하였으며 그 적합성을 검정하기 위해 기존배양액과 비교실험을 실시하였다. 딜의 NFT재배에 적합한 배양액을 개발하기 위해서 일본야채시험장 표준액을 1/4배액, 1/2배액 및 1배액으로 조성하여 재배한 결과, 1/2배액에서 생육과 수량이 가장 높았으며 근권내 pH와 EC의 변화도 안정되었고, 식물체내 무기이온 합량도 적정치로 나타나 딜의 양분흡수특성에 적합할 것으로 판단되었다. 따라서 일본야채시험장 1/2 배액의 양수분 흡수율(n/w)을 기준으로 새로운 배양액을 조성하였으며, 이온의 조성은 NO$_3$―N 8.85, NH$_4$―N 0.55, P 2.1, K 6.2, Ca 2.8, Mg 1.7 me.L$^{-1}$였다. 딜의 순환식 NFT 재배용으로 개발한 배양액의 적합성 검정실험 결과, 근권내 pH와 EC는 저농도인 SCU 1/2배액을 제외하고는 변화폭이 크게 나타나지 않았다. 본 실험에서 개발된 SCU 1배액은 기존에 허브 배양액으로 사용된 일본 야채 시험장 배양액과 비교할 때 생육과 수량면에서 우수하였으며, 엽내 무기성분 함량도 적정수준을 나타내었다. 따라서, 본 실험에서 개발된 SCU 배양액은 딜의 NFT재배에 적합한 배양액이라 할 수 있다.

  • PDF

2021 한국 갑상선영상 판독과 자료체계의 임상적용 (Clinical Application of the 2021 Korean Thyroid Imaging Reporting and Data System (K-TIRADS))

  • 나동규
    • 대한영상의학회지
    • /
    • 제84권1호
    • /
    • pp.92-109
    • /
    • 2023
  • 갑상선 결절 환자에서 초음파 검사는 일차적 영상 진단법으로 정립되어 있으며 치료 결정을 위한 핵심적인 진단 역할을 갖는다. Korean Thyroid Imaging Reporting and Data System(이하 K-TIRADS)는 초음파 유형에 기초한 암 위험도 분류체계로서 실시간 초음파 검사를 시행하면서 쉽게 결절 진단이 가능하다는 장점을 갖고 있다. 개정된 2021 K-TIRADS는 결절의 초음파 분류 기준을 보다 명확히 하였고, 고위험 갑상선암의 의심 소견이 없는 환자에서 병리진단검사를 결정하는 결절 크기 기준을 개정하여 불필요한 병리진단검사를 최소화하고 적절한 갑상선암 진단 예민도가 유지되도록 개정하였다. 갑상선영상의학진료는 갑상선 결절 환자의 진단 및 비수술적 치료를 수행하는 중요한 임상적 역할을 가지고 있으며, 적절한 환자 진료를 위해서는 표준적 진료 지침에 근거하여 진료가 수행되어야 한다.

임상에서의 현미경: 작동, 유지보수 및 레이저 안전 (Clinical Microscopy: Performance, Maintenance and Laser Safety)

  • 이태복
    • 대한임상검사과학회지
    • /
    • 제51권2호
    • /
    • pp.125-133
    • /
    • 2019
  • 임상병리 검사분야에 있어서 환자로부터 유래된 조직이나 세포의 형태학적 변화, 세포 생리, 세포 내 분자의 추적 및 신호전달 체계 등의 임상검사 및 관련 연구를 위한 빼놓을 수 없는 주요한 진단과 연구장비로서 현미경이 가지는 의미는 크다고 할 수 있다. 현미경에 대한 포괄적인 지식과 이해를 바탕으로 현미경의 올바른 사용, 관리와 유지보수는 신뢰도 높은 이미지 획득과 그에 따른 정확한 데이터 분석을 통한 질병의 진단을 위해서 반드시 요구되는 부분이라고 할 수 있다. 광학현미경의 표준 운영 절차(standard operating procedure, SOP)는 현미경의 작동 절차와 함께 검사실 규모에 따른 현장 사용자의 체계적인 현미경 장해 해결 방안과 기계적 원리에 대한 핵심 정보가 함께 수록되어야 한다. 현미경 유지관리 업무에는 대물, 접안렌즈와 현미경 내부 광학필터의 청소, 광원의 교체와 교정, XY재물대 유지보수, 공초점 레이저 주사 현미경(confocal laser scanning microscope)에서의 점확산함수(point spread function, PSF) 측정, 형광현미경에서의 검사 품질관리(quality control, QC)와 체계적인 현미경 장해 해결방안 등이 포함되어야 한다. 본 종설에서는 국제적 기준에 따른 레이저의 위험도에 따라 일부 현미경에 장착된 레이저 광원에 대한 안전지침과 보호장구에 대한 내용을 함께 소개하였다. 현미경을 통해 획득된 이미지는 촬영된 시점의 검체에 대한 모든 정보를 제공한다고 할 수 있으며, 적절한 유지보수 프로그램과 그에 따라 적합하게 관리된 현미경만이 이미지 데이터를 통한 정보의 획득, 올바른 해석과 정확한 진단에 반드시 필요한 선제 조건들이라고 하겠다.