• 제목/요약/키워드: standard of diagnosis

검색결과 1,186건 처리시간 0.028초

The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT (SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가)

  • Choi, Jong-Sook;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제12권3호
    • /
    • pp.214-221
    • /
    • 2008
  • Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion's anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested $^{131}I$-MIBG, Bone, $^{111}In$-Octreotide, Meckel's diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai' QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section's perfusion states by percentage. We compared the each section's perfusion-states differences between CT AC and Non AC by average${\pm}$standard deviation. Results: 1. The evaluation of fusion images : In high energy $^{131}I$ cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions' uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel's diverticulum case or to find lesions around bowels or organs with $^{111}In$ cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image ($68.58{\pm}7.55$) and CT corrected perfusion image ($76.84{\pm}6.52$) was the largest by $8.26{\pm}4.95$ (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

  • PDF

Development of a Korean Standard Structural Brain Template in Cognitive Normals and Patients with Mild Cognitive Impairment and Alzheimer's Disease (정상노인 및 경도인지장애 및 알츠하이머성 치매 환자에서의 한국인 뇌 구조영상 표준판 개발)

  • Kim, Min-Ji;Jahng, Geon-Ho;Lee, Hack-Young;Kim, Sun-Mi;Ryu, Chang-Woo;Shin, Won-Chul;Lee, Soo-Yeol
    • Investigative Magnetic Resonance Imaging
    • /
    • 제14권2호
    • /
    • pp.103-114
    • /
    • 2010
  • Purpose : To generate a Korean specific brain template, especially in patients with Alzheimer's disease (AD) by optimizing the voxel-based analysis. Materials and Methods : Three-dimensional T1-weighted images were obtained from 123 subjects who were 43 cognitively normal subjects and patients with 44 mild cognitive impairment (MCI) and 36 AD. The template and the corresponding aprior maps were created by using the matched pairs approach with considering differences of age, gender and differential diagnosis (DDX). We measured several characteristics in both our and the MNI templates, including in the ventricle size. Also, the fractions of gray matter and white matter voxels normalized by the total intracranial were evaluated. Results : The high resolution template and the corresponding aprior maps of gray matter, white matter (WM) and CSF were created with the voxel-size of $1{\times}1{\times}1\;mm$. Mean distance measures and the ventricle sizes differed between two templates. Our brain template had less gray matter and white matter areas than the MNI template. There were volume differences more in gray matter than in white matter. Conclusion : Gray matter and/or white matter integrity studies in populations of Korean elderly and patients with AD are needed to investigate with this template.

Evaluation of a Rapid Diagnostic Antigen Test Kit Ribotest Mycoplasma® for the Detection of Mycoplasma pneumoniae (Mycoplasma pneumoniae 감염의 신속 항원 검사 키트 "Ribotest Mycoplasma®"의 진단적 평가)

  • Yang, Song I;Han, Mi Seon;Kim, Sun Jung;Lee, Seong Yeon;Choi, Eun Hwa
    • Pediatric Infection and Vaccine
    • /
    • 제26권2호
    • /
    • pp.81-88
    • /
    • 2019
  • Purpose: Early detection of Mycoplasma pneumoniae is important for appropriate antimicrobial therapy in children with pneumonia. This study aimed to evaluate the diagnostic value of a rapid antigen test kit in detecting M. pneumoniae from respiratory specimens in children with lower respiratory tract infection (LRTI). Methods: A total of 215 nasopharyngeal aspirates (NPAs) were selected from a pool of NPAs that had been obtained from children admitted for LRTI from August 2010 to August 2018. The specimens had been tested for M. pneumoniae by culture and stored at $-70^{\circ}C$ until use. Tests with Ribotest $Mycoplasma^{(R)}$ were performed and interpreted independently by two investigators who were blinded to the culture results. Results: Among the 215 NPAs, 119 were culture positive for M. pneumoniae and 96 were culture negative. Of the culture-positive specimens, 74 (62.2%) were positive for M. pneumoniae by Ribotest $Mycoplasma^{(R)}$, and 92 of the 96 (95.8%) culture-negative specimens were negative for M. pneumoniae by Ribotest $Mycoplasma^{(R)}$. When culture was used as the standard test, the sensitivity and specificity of Ribotest $Mycoplasma^{(R)}$ were 62.2% and 95.8%, respectively. Additionally, the positive predictive value, negative predictive value, and overall agreement rates with Ribotest $Mycoplasma^{(R)}$ were 94.9%, 67.2%, and 77.2%, respectively. Conclusions: A positive test result of Ribotest $Mycoplasma^{(R)}$ suggests a high likelihood of culture-positive M. pneumoniae infection. However, a negative test result should be interpreted with caution because nearly one-third of negative test results reveal culture-positive M. pneumoniae infections.

Prophylactic Cranial Irradiation for Acute Lymphoblastic Leukemia in Childhood (소아 급성 림프모구성 백혈병의 예방적 전뇌 방사선조사)

  • Kim, In-Ah;Choi, Ihl-Bhong;Kang, Ki-Mun;Shinn, Kyung-Sub;Kim, Hack-Ki
    • Radiation Oncology Journal
    • /
    • 제14권2호
    • /
    • pp.137-147
    • /
    • 1996
  • Purpose : This report is the result f retrospective analysis for children who received prophylactic cranial irradiation combined with intrathecal chemotherapy. Materials and Methods : Ninety children with ALL who had got bone marrow remission after induction chemotherapy received PCI. All but 3 children were treated with a dose of 1800 cGy as a standard regimen. While the PCI was given, all patients received intrathecal chemotherapy. Results : Nine of 90 patients experienced CNS relapse during the duration of follow-up ranged from 36 to 96 months (median 60 months). Three children experienced BM relapse prior to CNS relapse. Therefore, CNS relapse rate as the first adverse event was $6.7\%$. Median time interval of CNS relapse was 16 months from the first day of hematologic complete remission. Eighty-nine percent of patients who had CNS relapse were associated with hematologic relapse. and $78\%$ of CNS relpase occurred during maintenance chemotherapy (on-therapy relapse). The CNS RFS at 2 and 5 years are $68\%$ and $42\%$, respectively with median of 43 months. The Prognostic factors affecting CNS RFS are initial WBC count (cut-off point of 50,000/ul), FAB subtype and CALGB risk criteria. The DFS at 2 and 5 years are 61 and $39\%$, respectively with median of 34 months. The prognostic factors affecting DFS are initial WBC count (cut-off point of 50,000/ul), FAB subtype, POG and CALGB risk criteria. Conclusions : In our study, $6.7\%$ of CNS relapse rate as a first adverse event was comparable with other studies. Various risk criteria was based on age at diagnosis and initial WBC count such as POG and CALGB criteria, had prognostic significance for CNS RFS and DFS. Prospective randomized trial according to prognostic subgroup based on risk criteria and systematic study about neuropsychologic function for long term survivors, are essential to determine the most effective and least toxic form of CNS prophylaxis.

  • PDF

The Evaluation and Development of Head and Neck Radiation Protective Device for Chest Radiography in 10 Years Children (소아(10세) 흉부 방사선촬영에서의 두경부 방사선 방어기구 개발 및 평가)

  • Lee, Jun Ho;Lim, Hyun Soo;Lee, Seung Yeol
    • Journal of Radiation Protection and Research
    • /
    • 제40권2호
    • /
    • pp.118-123
    • /
    • 2015
  • The frequency of diagnostic radiation examinations in medical institutions has recently increased to 220 million cases in 2011, and the annual exposure dose per capita was 1.4 mSv, 51% and 35% respectively, compared to those in 2007. The number of chest radiography was found to be 27.59% of them, the highest frequency of normal radiography. In this study, we developed a shielding device to minimize radiation exposure by shielding areas of the body which are unnecessary for image interpretation, during the chest radiography. And in order to verify its usefulness, we also measured the difference in entrance surface dose (ESD) and the absorbed dose, before and after using the device, by using an international standard pediatric (10 years) phantom and a glass dosimeter. In addition, we calculated the effective dose by using a Monte Carlo simulation-based program (PCXMC 2.0.1) and evaluated the reduction ratio indirectly by comparing lifetime attributable risk of cancer incidence (LAR). When using the protective device, the ESD decreased by 86.36% on average, nasal cavity $0.55{\mu}Sv$ (74.06%), thyroid $1.43{\mu}Sv$ (95.15%), oesophagus $6.35{\mu}Sv$ (78.42%) respectively, and the depth dose decreased by 72.30% on average, the cervical spine(upper spine) $1.23{\mu}Sv$ (89.73%), salivary gland $0.5{\mu}Sv$ (92.31%), oesophagus $3.85{\mu}Sv$ (59.39%), thyroid $2.02{\mu}Sv$ (73.53%), thoracic vertebrae(middle spine) $5.68{\mu}Sv$ (54.01%) respectively, so that we could verify the usefulness of the shielding mechanism. In addition, the effective dose decreased by 11.76% from $8.33{\mu}Sv$ to $7.35{\mu}Sv$ before and after wearing the device, and in LAR assessment, we found that thyroid cancer decreased to male 0.14 people (95.12%) and female 0.77 people (95.16%) per one million 10-year old children, and general cancers decreased to male 0.14 people (11.70%) and female 0.25 people (11.70%). Although diagnostic radiation examinations are necessary for healthcare such as the treatment of diseases, based on the ALARA concept, we should strive to optimize medical radiation by using this shielding device actively in the areas of the body unnecessary for the diagnosis.

A Study on Establishment of Reference Value of CA 72-4 (CA 72-4 참고치 설정에 관한 연구)

  • An, Jae-Seok;Kim, Ji-Na;Joe, Ye-Ji;Yoon, Sang-Hyuk;Kim, Yoon-Cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제25권2호
    • /
    • pp.25-28
    • /
    • 2021
  • Purpose CA 72-4 is a tumor marker that uses two monoclonal antibodies, CC49 and B72.3, to measure tumor-related glycoprotein(TAG72) in the serum. CA 72-4 is used to diagnose stomach, ovarian, and pancreatic cancers, and is known to perform high specificity for stomach cancer. The purpose of this study is to re-evaluate the reference value provided by the manufacturer through revalidation of the reference value in CA 72-4. Furthermore this study was conducted to provide useful help when making a clinical diagnosis at gastric cancer center. Materials and Methods We selected 271 patients who had been to health care center in national cancer center for the month of November 2020. The gender of the subjects was 140 males and 131 females, and the age group was from 30s to 60s. The reagent used in the study was a CA 72-4 IRMA KIT (ISOTOPES, Hungary) and the results were measured using a Dream Gamma-10 gamma counter (Shinjin medics, Korea). Results Statistical analysis of the results of this study used Hoffmann's method and Bayesian's method, which are primarily used in setting reference value. As a result of measuring CA 72-4 of 271 patients, the mean value was 4.54 U/mL and the median value was 3.30 U/mL. 24 people who deviated from 3SD were excluded from the measured value, the mean calculated after that was 3.53 U/mL, median was 3.00 U/mL and SD was 1.89. The reference value calculated based on this results was set to 7.31 U/mL. Conclusion The reference value provided by the manufacturer is less than 4 U/mL. It is slightly different from the value calculated in this study, 7.31 U/mL, so it seems necessary to reset the reference value according to the laboratory environment. Currently, we are receiving inquiries about the reference value from the center for gastric cancer at National Cancer Center. If additional research is carried out along with this study, it will be possible to set more accurate reference value.

Comparison of Glomerular Filtration Rate Using Gates Method and Serum Creatinine (Gates 방법과 혈청 크레아티닌을 이용한 사구체 여과율의 비교)

  • Yun, Jong-Jun;Lee, Hyo-Yeong;Lee, Hwa-Jin;Lee, Mu-Seok;Song, Hyeon-Seok;Park, Se-Yun;Jeong, Ji-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제13권3호
    • /
    • pp.61-66
    • /
    • 2009
  • Purpose: Glomerular filtration rate (GFR) is considered as the best overall index for the level of renal function, diagnosis of doubtful kidney disease, progress observation from chronic kidney disease and is measured with the various methods. In this study, We measured standard GFR by Gates method and attempted to compare the result with serum creatinin-based, Cockcroft-Gault(C-G) formula and Modification of Diet in Renal Disease (MDRD) formula. Materials and methods: 217 patients (127 men, 90 women, mean age $51.3{\pm}16.9$) with various renal function were examined. we compared the GFR using $^{99m}Tc$-DTPA (Gates), C-G formula and MDRD formula. Results: Significant correlations were noted between 2 different GFR estimates (from C-G formula: r=0.864, p<0.0001, MDRD formula: r=0.831, p<0.0001) and $^{99m}Tc$-DTPA (Gates) GFR. Average of serum creatinine (Scr) was measured with $3.0{\pm}3.1\;mg/dL$, In patients with normal renal function (Scr<1.5 mg/dL), $^{99m}Tc$-DTPA (Gates) GFR was statistically significant to C-G formula (p<0.0001) and MDRD formula (p<0.0001). In patients with mild to moderate renal insufficiency (1.5$^{99m}Tc$-DTPA (Gates) GFR was not statistically significant to C-G formula (p=0.181) and MDRD formula (p=0.127). In patients with severe renal insufficiency (Scr>4.0mg/dL), $^{99m}Tc$-DTPA (Gates) GFR was statistically significant to C-G formula and MDRD formula (p<0.0001). Conclusions: Glomerular filtration rate using Gates method was closly correlated to C-G formula and MDRD formula. In patients with normal renal function, $^{99m}Tc$-DTPA (Gates) GFR was significantly lower than C-G formula and MDRD formula. In patients with mild to moderate renal insufficiency, $^{99m}Tc$-DTPA (Gates) GFR was simmilar with C-G formula and MDRD formula. In patients with severe renal insufficiency, $^{99m}Tc$-DTPA (Gates) GFR was significantly higher than C-G formula and MDRD formula. None of the three different methods was clearly superior to the others.

  • PDF

The Value of Delayed $^{18}F$-FDG PET/CT Imaging for Differentiating Axillary Lymph Nodes in Breast Cancers (유방암 환자에서 액와 림프절 진단을 위한 $^{18}F$-FDG PET/CT 지연 검사의 유용성)

  • Ji, Young-Sik;Son, Ju-Cheol;Park, Cheol-Woo
    • Journal of radiological science and technology
    • /
    • 제36권4호
    • /
    • pp.313-318
    • /
    • 2013
  • Positron emission tomography/computed tomography (PET/CT) imaging with fluorodeoxyglucose (FDG) have been used as a powerful fusion modality in nuclear medicine not only for detecting cancer but also for staging and therapy monitoring. Nevertheless, there are various causes of FDG uptake in normal and/or benign tissues. The purpose of present study was to investigate whether additional delayed imaging can improve the diagnosis to differentiate the rates of FDG uptake at axillary lymph nodes (ALN) between malignant and benign in breast cancer patients. 180 PET/CT images were obtained for 27 patients with ALN uptake. The patients who had radiotherapy and chemotherapy were excluded from the study. $^{18}F$-FDG PET/CT scan at 50 min (early phase) and 90 min (delayed phase) after $^{18}F$-FDG injection were included in this retrospective study. The staging of cancers was confirmed by final clinical according to radiologic follow-up and pathologic findings. The standardized uptake value (SUV) of ALN was measured at the Syngo Acquisition Workplace by Siemens. The 27 patients included 18 malignant and 9 ALN benign groups and the 18 malignant groups were classified into the 3 groups according to number of metastatic ALN in each patient. ALNs were categorized less than or equal 3 as N1, between 4 to 9 as N2 and more than 10 as N3 group. Results are expressed as the mean${\pm}$standard deviation (S.D.) and statistically analyzed by SPSS. As a result, Retention index (RI-SUV max) in metastasis was significantly higher than that in non-metastasis about 5 fold increased. On the other hand, RI-SUV max in N group tended to decrease gradually from N1 to N3. However, we could not prove significance statistically in malignant group with ANOVA. As a consequence, RI-SUV max was good indicator for differentiating ALN positive group from node negative group in breast cancer patients. These results show that dual-time-point scan appears to be useful in distinguishing malignant from benign.

Fertility and Rate of Fertilizer Application for Orchard Soils of Apple and Pear (사과 및 배 과수토양(果樹土壤)의 비옥도구분(肥沃度區分)에 의한 시비기준(施肥基準) 설정(設定))

  • Lee, Choon-Soo;Lee, Ju-Young;Lee, Yong-Jae;Shin, Jae-Sung;Han, Ki-Hak;Kim, Dong-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • 제26권2호
    • /
    • pp.103-110
    • /
    • 1993
  • This study was made to evaluate the chemical properties of 481 farmers' orchard fields in An-Seong area. And the reasonable ferilizer rates were recommended utilizing the result of soil analysis. The results are summarized as follows : 1. As the soil fertility status of collected soil samples were evaluated on the basis of temporary optimal range for each soil chemical properties, 12.7 to 49.6% of the total 481 farmers' fields were range for soil improvement. 2. The contents of chemical component have a tendancy to decrease with depth gradually from surface to subsoil. 3. According to the relationship between the contents of soil component in subsoil and those in surface soil, the fertility condition of subsoil could be estimated on the basis of analysis data of surface soil. 4. The multiple regression equation for pear yield prediction to the organic matter and exchangable calcium contents in the soil were obtained. 5. Referring the average value, distribution ratio compared to the optimum level for each soil chemical properties and standard fertilizer rate, the soil fertility status could be categorized as "High" "Medium" and "Low". For each category, the recommended amounts for NPK and organic matter application were established. 6. The recommended rates through soul fertility diagnosis were less than farmer's dosage in the range 7.1~7.7 kg/10a for N, 0.8~11.5 kg/10a for $P_2O_5$, 7.1~19.9 kg/10a for $K_2O$ and 90~116 kg/10a for lime.

  • PDF

The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement (부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가)

  • Kang, Young-Eun;Kim, Eun-Hye;Kim, Ho-Sung;Choi, Jong-Sook;Choi, Woo-Jun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제15권1호
    • /
    • pp.3-9
    • /
    • 2011
  • Purpose: Generally dual energy X-ray absorptiometry has been used for the purpose of evaluation of osteoporosis and treatment. Recently the interest of obesity came to be high and body percent fat test is increasing. Existing measure of body fat have to scan the whole body can be evaluated, but only lumbar spine and hip measurements was assumed to be whole body fat as well as improving the software. It tries to check whether the part measured value not being whole body measurement has the validity or not compared with the value calculated with the method that it is different, it forgives through a correlation with a (BIA) and (BMI). Materials and Methods: In 2010, the body percent fat was measured among the examinee coming to the Asan Medical Center public health care center from March till August against 90 females more than 40 years old through (DXA) and BIA. BMI utilized the value which wrote an hight and weight measured through the body measuring instrument in the examinee information and is automatically calculated. In addition, it classified as the low weight ($13-18.5kg/m^2$), normal ($18.5-25kg/m^2$), and corpulence ($25-30kg/m^2$) based on BMI and so that it could check whether there was the difference according to the weight or not BMI and BIA and correlation between DXA were analyzed in each group. The statistical program for the analysis used SPSS 12.0. Results: The comparison of DXA at 3 which it divides into the low weight and normal and corpulence groups and BIA did not show the difference noted statistically in all groups and the between group comparison was exposed to do not have a meaning. The body percent fat measured by the correlation analysis result DXA at the state that it doesn't divide into the group showed the high correlation (r=0.908, p0.01) noted statistically compared with BMI and showed the high correlation noted statistically in a comparison with BIA (r=0.927, p0.01). Conclusion: It confirmed that the whole body percent fat presumed from the part bone density measurement showed the excel correlation compared with BIA and BMI and information is high. There is still no clear standard about the presumed whole body percent fat and it is difficult to evaluate the fat evaluation by the bone mineral density measurement. However, it is determined that the information offering which is more objective through the comparative study with the body percent fat which is very efficient and in that it can obtain till the information about a fat as well as diagnosis of the osteoporosis through the bone density checkup is measured by the afterward telegraph bone density checkup and is clinically useful is possible.

  • PDF