• Title/Summary/Keyword: standard measurement methods

Search Result 870, Processing Time 0.029 seconds

Measurement of Time Delay in Optical Fiber Line Using Rayleigh Scattering (Rayleigh 산란을 이용한 광선로의 time delay 측정)

  • Kwon, Hyung-Woo;Yu, Il;Yu, Yun-Sik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.5B
    • /
    • pp.365-369
    • /
    • 2012
  • It is very important to control synchronization by inter-network delay compensation in high speed synchronous optcial transmission network systems. In this study we designed a delay measurement system based on OTDR using Rayleigh backscatterer in order to compensate for time delay due to the length of optical fiber line. We observed waveform variations on both averaging time and peak power of laser pulse. Finally, we executed experimental demonstration on its accuracy and test repeatability by comparison to the methods practically used in the industry. Experimental results show maximum error of 0.06usec and standard deviation of 0.021usec, which means it's possibly applied to delay control system for mobile repeaters and stations.

Scattering Parameter-based Measurement of Planar EMI filter

  • Wang, Shishan;Gong, Min;Xu, Chenchen
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.806-813
    • /
    • 2014
  • Planar electromagnetic interference (EMI) filters are widely used to restrain the conducted EMI of switching power supplies. Such filters are characterized by small size, low parasitic parameters, and better high-frequency performance than the passive discrete EMI filter. However, EMI filter performance cannot be exactly predicted by using existing methods. Therefore, this paper proposes a method to use scattering parameters (S-parameters) for the measurement of EMI filter performance. A planar EMI filter sample is established. From this sample, the relationship between S-parameters and insertion gain (IG) of EMI filter is derived. To determine the IG under different impedances, the EMI filter is theoretically calculated and practically measured. The differential structure of the near-field coupling model is also deduced, and the IG is calculated under standard impedance conditions. The calculated results and actual measurements are compared to verify the feasibility of the theory.

Skid Resistance of the Sidewalks in Winter (겨울철 보도 미끄럼 저항)

  • Kim, Yong Seok
    • International Journal of Highway Engineering
    • /
    • v.15 no.6
    • /
    • pp.17-23
    • /
    • 2013
  • PURPOSES : This study aimed to measure the skid resistance of the sidewalk in order to find out the relationship between different surface types and skid resistance. By using British Pendulum Tester, skid resistance of sidewalk was measured in a wet after snow-melt, sludgy, and snowy conditions. METHODS : The skid resistance was measured on surfaces including Concrete Interlocking Block Paving, Colour Asphalt Pavement, Granite Block Paving, Manhole, and Tactile Paving for Visually Impaired. Five trials at each measurement were made, and the average and standard deviation were derived. RESULTS : The skid resistance measured in wet after snow-melt, sludgy, and snowy conditions for the various surface types are summarized and compared. Reduction rates of skid resistance of sludgy and snowy against wet after snow-melt are also analysed. The skid resistance variation between measurement points which mimic pedestrian route in study site are analysed to check out the consistency of the skid resistance along the sidewalk. CONCLUSIONS : The study concluded that the skid resistance of sidewalk surfaces varied depending on the surface types and weather conditions. Secondly, reduction rates of skid resistance according to weather changes are varied depending on the surface types, Thirdly, consistency of skid resistance along the pedestrian route is hardly acquired in the study site at least. So, future study on the consistency evaluation for skid resistance along sidewalk is strongly recommended.

Pavement Performance Model Development Using Bayesian Algorithm (베이지안 기법을 활용한 공용성 모델개발 연구)

  • Mun, Sungho
    • International Journal of Highway Engineering
    • /
    • v.18 no.1
    • /
    • pp.91-97
    • /
    • 2016
  • PURPOSES : The objective of this paper is to develop a pavement performance model based on the Bayesian algorithm, and compare the measured and predicted performance data. METHODS : In this paper, several pavement types such as SMA (stone mastic asphalt), PSMA (polymer-modified stone mastic asphalt), PMA (polymer-modified asphalt), SBS (styrene-butadiene-styrene) modified asphalt, and DGA (dense-graded asphalt) are modeled in terms of the performance evaluation of pavement structures, using the Bayesian algorithm. RESULTS : From case studies related to the performance model development, the statistical parameters of the mean value and standard deviation can be obtained through the Bayesian algorithm, using the initial performance data of two different pavement cases. Furthermore, an accurate performance model can be developed, based on the comparison between the measured and predicted performance data. CONCLUSIONS : Based on the results of the case studies, it is concluded that the determined coefficients of the nonlinear performance models can be used to accurately predict the long-term performance behaviors of DGA and modified asphalt concrete pavements. In addition, the developed models were evaluated through comparison studies between the initial measurement and prediction data, as well as between the final measurement and prediction data. In the model development, the initial measured data were used.

Development of Nude Pattern on Top for Producing Parametric Production Patterns (파라메트릭 프로덕션 패턴 제작을 위한 상의 누드 패턴 개발)

  • Kim, Na Rae;Nam, Yun Ja;Park, Jinhee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.43 no.5
    • /
    • pp.711-724
    • /
    • 2019
  • The automatic drafting of clothing patterns can be realized through an Apparel Cad System when the clothing pattern has a pattern expression in human dimensions. However, it is difficult to apply automatic systems because it is difficult to express the ready-to-wear of various complex designs with one system. This study develops ready-to-wear patterns in an automatic drafting style and also develops nude patterns with human dimension-based drafting styles that can be applied to enable the setting of margins by design. For this purpose, radial body length measurement items and measurement methods were newly defined for female standard dummy and nude pattern systems. The institutional program was developed through the principle of a nude pattern system which is different from the pattern system of the existing system. The nude pattern developed in this study represents a basis and framework for the gradual transformation of the production pattern into the automatic system of the future and as a pattern having an institutional formula based on human dimensions.

Evaluation of craniofacial morphology in short-statured children: growth hormone deficiency versus idiopathic short stature

  • Kim, Ki Bong;Kim, Eun-Kyong;Jang, Kyung Mi;Kim, Min Seon;Park, Eun Young
    • Journal of Yeungnam Medical Science
    • /
    • v.38 no.1
    • /
    • pp.47-52
    • /
    • 2021
  • Background: Short stature is defined as a height below the 3rd percentile or more than two standard deviations below the mean for a given age, sex, and population. There have been inconsistent results regarding craniofacial morphology in short-statured children. This study aimed to analyze the differences between short-statured children with growth hormone deficiency, idiopathic short-statured children, and normal children. Methods: Thirty-one short-statured children with growth hormone deficiency, 32 idiopathic short-statured children, and 32 healthy children were enrolled in this study. The measurements of their craniofacial structures from lateral cephalograms were evaluated. Results: There were statistically significant differences among the three groups seven variables (anterior cranial base length, posterior cranial base length, total cranial base length, upper posterior facial height, posterior total facial height, mandibular ramus length, and overall mandibular length) in the linear measurement and five variables (saddle angle, gonial angle, mandibular plane angle, position of mandible, and maxilla versus mandible) in the angular measurement. Conclusion: Compared to the control group, many linear and angular measurements of the craniofacial structures were significantly different in the two short-statured groups (p <0.05). Treatment plans by orthodontists should include these craniofacial structure characteristics.

The test-retest reliability of gait kinematic data measured using a portable gait analysis system in healthy adults

  • An, Jung-Ae;Byun, Kyung-Seok;Lee, Byounghee
    • Journal of Korean Physical Therapy Science
    • /
    • v.27 no.3
    • /
    • pp.25-34
    • /
    • 2020
  • Background: Gait analysis is an important measurement for health professionals to assess gait patterns related to functional limitations due to neurological or orthopedic conditions. The purpose of this study was to investigate the reliability of the newly developed portable gait analysis system (PGAS). Design: Cross-sectional design. Test-retest study. Methods: The PGAS study was based on a wearable sensor, and measurement of gait kinematic parameters, such as gait velocity, cadence, step length and stride length, and joint angle (hip, knee, and ankle) in stance and swing phases. The results were compared with a motion capture system (MCS). Twenty healthy individuals were applied to the MCS and PGAS simultaneously during gait performance. Results: The test-retest reliability of the PGAS showed good repeatability in gait parameters with mean intra-class correlation coefficients (ICCs) ranging from 0.840 to 0.992, and joint angles in stance and swing phase from 0.907 to 0.988. The acceptable test-retest ICC was observed for the gait parameters (0.809 to 0.961), and joint angles (0.800 to 0.977). Conclusion: The results of this study indicated that the developed PGAS showed good grades of repeatability for gait kinematic data along with acceptable ICCs compared with the results from the MCS. The gait kinematic parameters in healthy subjects can be used as standard values for adopting this PGAS.

Rapid Screening of Naturally Occurring Radioactive Nuclides (238U, 232Th) in Raw Materials and By-Products Samples Using XRF

  • Park, Ji-Young;Lim, Jong-Myoung;Ji, Young-Yong;Lim, Chung-Sup;Jang, Byung-Uck;Chung, Kun Ho;Lee, Wanno;Kang, Mun-Ja
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.359-367
    • /
    • 2016
  • Background: As new legislation has come into force implementing radiation safety management for the use of naturally occurring radioactive materials (NORM), it is necessary to establish a rapid and accurate measurement technique. Measurement of $^{238}U$ and $^{232}Th$ using conventional methods encounter the most significant difficulties for pretreatment (e.g., purification, speciation, and dilution/enrichment) or require time-consuming processes. Therefore, in this study, the applicability of ED-XRF as a non-destructive and rapid screening method was validated for raw materials and by-product samples. Materials and Methods: A series of experiments was conducted to test the applicability for rapid screening of XRF measurement to determine activity of $^{238}U$ and $^{232}Th$ based on certified reference materials (e.g., soil, rock, phosphorus rock, bauxite, zircon, and coal ash) and NORM samples commercially used in Korea. Statistical methods were used to compare the analytical results of ED-XRF to those of certified values of certified reference materials (CRM) and inductively coupled plasma mass spectrometry (ICP-MS). Results and Discussion: Results of the XRF measurement for $^{238}U$ and $^{232}Th$ showed under 20% relative error and standard deviation. The results of the U-test were statistically significant except for the case of U in coal fly ash samples. In addition, analytical results of $^{238}U$ and $^{232}Th$ in the raw material and by-product samples using XRF and the analytical results of those using ICP-MS ($R^2{\geq}0.95$) were consistent with each other. Thus, the analytical results rapidly derived using ED-XRF were fairly reliable. Conclusion: Based on the validation results, it can be concluded that the ED-XRF analysis may be applied to rapid screening of radioactivities ($^{238}U$ and $^{232}Th$) in NORM samples.

Comparison and evaluation of methods for the measurement of total nitrogen in wastewater (고농도 질소함유 폐수의 총질소 분석법 비교·평가)

  • Choi, Sung-Deuk;Chang, Yoon-Seok
    • Analytical Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.25-32
    • /
    • 2007
  • The measurement methods for total nitrogen in wastewater containing a high concentration of nitrogen were evaluated. (1) The UV spectrophotometry, (2) reduction-distillation Kjeldahl, (3) total Kjeldahl nitrogen, and (4) ion chromatography methods were applied. The experimental procedure of the UV spectrophotometric method was simple, but it produced large errors deriving from the dilution of samples and calibration standards. While, the reduction-distillation Kjeldahl method didn't need dilution, but the amount of Devarda's alloy and NaOH lead to large errors up to 50 mg/L. The levels of total nitrogen measured by each method were as follows: reduction-distillation Kjeldahl ($568.6{\pm}38.7mg/L$) > UV spectrophotometry ($527.3{\pm}9.6mg/L$) > total Kjeldahl nitrogen method ($494.7{\pm}21.4mg/L$) > ion chromatography method ($417.9{\pm}7.3mg/L$). Therefore, the reduction-distillation Kjeldahl method is preferred for wastewater with the high concentration of nitrogen. Optimal conditions for each experimental procedure, however, are needed to be confirmed, and the Standard Operation Procedure (SOP) for total nitrogen is required for reliable measurements.

Exposure of Carcinogens in Electronics Industries and Strategy for Control of Carcinogens: Using Work Environment Measurement Database (2013-2017) in Korea (한국 전자산업에서 작업환경측정을 통해 파악된 발암물질들 노출 특성과 발암물질관리 방안: 작업환경측정자료(2013-2017)를 중심으로)

  • Mia, Son;Jaewon, Yun;Yu Seoung, Hwang;Mijin, Park;MinSeo, Choi;Mi-Young, Lee;Domyung, Paek
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.4
    • /
    • pp.302-324
    • /
    • 2022
  • Objectives: The objective of this study is to investigate exposure to occupational carcinogens in the nationwide electronics industries and to establish a strategy for control of occupational carcinogens in South Korea. Methods: We evaluated occupational carcinogens as defined by International Agency for Research on Cancer (IARC) using a nationwide work environment measurement database on the electronics industry in South Korea measured between 2013 and 2017 in accordance with the Occupational Safety and Health Act. Results: The number of occupational carcinogens found in the electronics industry in South Korea were: 20 for IARC Group 1, 14 for Group 2A, and 30 for Group 2B. The occupational carcinogens (Group 1) most frequently exposed were strong-inorganic-acid mists containing sulfuric acid (sulfuric acid), welding fumes, mineral oils (untreated or mildly treated), nickel compounds, silica dust, crystalline substances in the form of quartz or cristobalite, formaldehyde, arsenic and inorganic arsenic compounds, chromium (VI) compounds, trichloroethylene, cadmium and cadmium compounds, vinyl chloride, ethylene oxide, wood dust, beryllium and beryllium compounds, 1,3 butadiene, benzene, and others. Among them, the carcinogens (Group 1) exceeding the acceptable standard were trichloroethylene, formaldehyde, and ethylene oxide. The working environment measurement system as regulated by Occupational Safety and Health Act is not properly assessed and managed for occupational carcinogens in South Korea. A component analysis for all materials used should be set up to practically reduce occupational carcinogens. A ban on the use of occupational carcinogens and the development of alternative materials are needed. The occupational carcinogens below the acceptable standards should be carefully examined and a new standard for exposure needs to be established. Conclusions: The Occupational Safety and Health Act should be improved to identify and monitor occupational carcinogens at work sites. A strategy for occupational safety and health systems should be provided to give direction to workers' needs and right to know.