• Title/Summary/Keyword: standard index

Search Result 2,032, Processing Time 0.032 seconds

Quantification of three-dimensional facial asymmetry for diagnosis and postoperative evaluation of orthognathic surgery

  • Cao, Hua-Lian;Kang, Moon-Ho;Lee, Jin-Yong;Park, Won-Jong;Choung, Han-Wool;Choung, Pill-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.17.1-17.11
    • /
    • 2020
  • Background: To evaluate the facial asymmetry, three-dimensional computed tomography (3D-CT) has been used widely. This study proposed a method to quantify facial asymmetry based on 3D-CT. Methods: The normal standard group consisted of twenty-five male subjects who had a balanced face and normal occlusion. Five anatomical landmarks were selected as reference points and ten anatomical landmarks were selected as measurement points to evaluate facial asymmetry. The formula of facial asymmetry index was designed by using the distances between the landmarks. The index value on a specific landmark indicated zero when the landmarks were located on the three-dimensional symmetric position. As the asymmetry of landmarks increased, the value of facial asymmetry index increased. For ten anatomical landmarks, the mean value of facial asymmetry index on each landmark was obtained in the normal standard group. Facial asymmetry index was applied to the patients who had undergone orthognathic surgery. Preoperative facial asymmetry and postoperative improvement were evaluated. Results: The reference facial asymmetry index on each landmark in the normal standard group was from 1.77 to 3.38. A polygonal chart was drawn to visualize the degree of asymmetry. In three patients who had undergone orthognathic surgery, it was checked that the method of facial asymmetry index showed the preoperative facial asymmetry and the postoperative improvement well. Conclusions: The current new facial asymmetry index could efficiently quantify the degree of facial asymmetry from 3D-CT. This method could be used as an evaluation standard for facial asymmetry analysis.

Study on the examination and revision about the standard level of the Extreme heat watch warning system for reduction of personal or property injury (인명.재해 피해 저감을 위한 폭염특보기준 검토 및 보완에 관한 연구)

  • Park, Jong-Kil;Jung, Woo-Sik;Song, Jeong-Hui;Kim, Eun-Byul
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.89-92
    • /
    • 2008
  • The extreme heat watch warning system(EHWWS) that Korea Meterological Administration carried out a preliminary from July 1, 2007, considered both daily maximum temperature and daily maximum heat index simultaneously. It was requested revision of the standard level of EHWWS to solve the difficulty of forecasting occurred when we were considering two parameters simultaneously and we did not considering heat index according to areas. For this, we established three type standard, such as type 1 that considered both daily maximum temperature and daily maximum heat index, Under the extreme heat day that daily minimum temperature was more than $25^{\circ}C$, type 2 that considered daily maximum temperature and type 3 that considered only daily maximum heat index and then analyzed whether these 3 types satisfies the excess mortality of the extreme heat warning or not. As a results, type 1 and 2 were more explain away excess mortality each warning step than type 3. type 2 could also apply case of not to consider heat index according to areas and had a merit for extreme heat forecasting easily because the standard was simple. Therefore we think type 2 is more suitable and reasonable standard for Korea extreme heat watch warning system(KEHWWS) than type 1. In addition, we need to develop model that exactly predicts the excess mortality will be take place during the extreme heat warning and construct KEHWWS.

  • PDF

A Study on Improving Drought Indices & Developing their Outlook Technique for Korea (국내 가뭄지수의 개선과 전망기법의 개발에 관한 연구)

  • Ahn, Kuk-Hyun;Kim, Young-Oh
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2010.05a
    • /
    • pp.6-12
    • /
    • 2010
  • 일반적으로 가뭄은 기상학적 가뭄, 농업적 가뭄, 수문학적 가뭄의 유형 등으로 분류한다. 본 연구에서는 우리나라에 적합한 수문학적 가뭄 지수인 물가용지수(Water Availability Index)를 개발하였다. 또한 다각적인 가뭄평가를 위해 기상학적 가뭄의 평가할 수 있는 표준강수지수(Standard Precipitation Index)와 농업적 가뭄을 평가할 수 있는 토양수분지수(Soil Moisture Index) 그리고 개발한 물가용지수(Water Availability Index)를 지수의 가뭄에 대한 등급을 통일시키기 위해 새롭게 산정하였다. 또한 기상청에서 제시하고 있는 월간기상정보 자료를 이용하여 가뭄전망을 할 수 있는 기법을 개발하였다.

  • PDF

A Comparison of Standard Shiftwork Index between Night Shift Fixed Nurses and Rotating Shift Nurses (야간전담간호사와 3교대간호사의 표준 교대근무 지표(Standard Shiftwork Index) 차이)

  • Kim, Jeoung Hee;Kim, Myoung Sook;Kim, Yeon Hee
    • Journal of Korean Clinical Nursing Research
    • /
    • v.23 no.1
    • /
    • pp.54-63
    • /
    • 2017
  • Purpose: The purpose of this study was to compare the working status and Standard Shiftwork Index (SSI) between night shift-fixed nurses and rotating shift nurses. Methods: Participants were 367 nurses working as registered nurses at 7 different medical institutions. The data were collected from August 8, 2016 to September 30, 2016. Results: Night shift fixed nurses were more satisfied with work schedule than rotating shift nurses. Rotating shift nurses reported higher SSI scores, such as chronic fatigue, musculoskeletal problems, than night shift fixed nurses. In SSI's sub-items, rotating shift nurses reported higher scores, such as the amount of sleep, feeling well after sleep, heartburn or stomach-ache and heartbeat irregularities, than night shift fixed nurses. Conclusion: The results indicated that night shift fixed system might be an effective method to improve nurses' work satisfaction. It is necessary to figure out any suitable night shift fixed system based on the characteristics of each nursing organization. The SSI might be an useful tool to measure the nurses' satisfaction in reference to their work shift.

Response Time Index and Suppression Capability of Standard and Quick Response Sprinkler Head (표준형 및 속동형 스프링클러헤드의 반응시간지수와 소화성능)

  • 정길순;이병곤
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.59-70
    • /
    • 1998
  • In this study, response time index(RTI) of standard and quick response type sprinkler head are measured and compared through ramp and plunge test in heated wind tunnel. Also discharge rate and water distribution, actual delivered density(ADD), fire test with wood cribs are performed to compare the fire suppression capability and the operation time and temperature between standard and quick response type sprinkler head.

  • PDF

A Study on the Modified Broca's Index to Estimate Standard Body Weight of Korean Adults (표준체중 산출을 위한 Modified Broca's Index에 관한 조사)

  • Cho, Byoung-Mann
    • Journal of Preventive Medicine and Public Health
    • /
    • v.16 no.1
    • /
    • pp.35-40
    • /
    • 1983
  • The author investigated the modified Broca's index that could be applied to Korean adults, what is called Korean Broca's Index, with 2322 apparently healthy subjects of 20-59 years old in order to obtain the index which could be used to estimate the standard body weight of Korean adults. The obtained results were as follows: 1. Linear regression equation of body weight to height was Y (weight in kg)=0.7195 X (height in cm)-57.9746 in male, and V (weight in kg)=0.4288 X (height in cm)-16.6528 in female. 2. Estimated constant that could be applied to Korean Broca's Index was 0.93 in male and 0.89 in female, and these sexual difference was statistically significant. (P<0.01)

  • PDF

Analysis of Drought Characteristics in Gyeongbuk Based on the Duration of Standard Precipitation Index

  • Ahn, Seung Seop;Park, Ki bum;Yim, Dong Hee
    • Journal of Environmental Science International
    • /
    • v.28 no.10
    • /
    • pp.863-872
    • /
    • 2019
  • Using the Standard Precipitation Index (SPI), this study analyzed the drought characteristics of ten weather stations in Gyeongbuk, South Korea, that precipitation data over a period of 30 years. For the number of months that had a SPI of -1.0 or less, the drought occurrence index was calculated and a maximum shortage months, resilience and vulnerability in each weather station were analyzed. According to the analysis, in terms of vulnerability, the weather stations with acute short-term drought were Andong, Bonghwa, Moongyeong, and Gumi. The weather stations with acute medium-term drought were Daegu and Uljin. Finally the weather stations with acute long-term drought were Pohang, Youngdeok, and Youngju. In terms of severe drought frequency, the stations with relatively high frequency of mid-term droughts were Andong, Bonghwa, Daegu, Uiseong, Uljin, and Youngju. Gumi station had high frequency of short-term droughts. Pohang station had severe short-term ad long-term droughts. Youngdeok had severe droughts during all the terms. Based on the analysis results, it is inferred that the size of the drought should be evaluated depending on how serious vulnerability, resilience, and drought index are. Through proper evaluation of drought, it is possible to take systematic measures for the duration of the drought.

Availability Assessment of Meteorological Drought Index for Agricultural Drought Estimation in Ungauged Area of Agricultural Drought Parameter (농업가뭄인자 미계측 지역의 농업가뭄 추정을 위한 기상학적 가뭄지수의 활용성 평가)

  • Park, Min Woo;Kim, Sun Joo;Kwon, Hyung Joong;Kim, Phil Shik;Kang, Seung Mook;Lee, Jae Hyuk
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.59 no.5
    • /
    • pp.127-136
    • /
    • 2017
  • The object of this study was to assess availability of meteorological drought index for agricultural dorught estimation in ungauged area of agricultural drought parameters which are reservoir water level and soil moisture. The IADI (Integrated Agricultural Drought Index) and the SPI (Standard Precipitation Index), which are the criteria for determining agricultural drought and meteorological drought, were calculated and compared. For this purpose, the droughts that occurred in the Baeksan reservoir in Gimje and the Edong reservoir in Suwon were evaluated by using the IADI and SPI drought indecies. In addition, we compared and analyzed the depth of drought based on the two drought indices. Evaluations derived form the IADI and SPI showed that the standard precipitation index tended to indicate the occurrence of drought earlier than the integrated agricultural drought index. However, the integrated agricultural drought index was better than the standard precipitation index at evaluating the severity of drought during the period of irrigation. The relationship between these two drought indices seems to be useful for decision making in the case of drought, and it is considered that more studies are needed to examine the applicability of these drought indexes.

Analysis on the Actual Environmental Conditions of Domestic and Oversea Police Detention Facilities (국내외 경찰서 유치시설의 환경 실태 분석)

  • Cho, Hyeonmi
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.1
    • /
    • pp.339-349
    • /
    • 2013
  • The primary purpose of this research was to set up the standard guidelines for the planning of interior architectural environments of the detention facilities at the Korean Police Stations. By visit-studying the actual interior environmental conditions of 5 different kinds' domestic Correcting Facilities and 5 domestic police detention facilities and 2 foreign police detention facilities, comparing them to the existing Korean correctional institutions' cell facilities, that the strengths and weaknesses had been analyzed to extract the main concepts and the planning scheme for the Standard Korean Police Detention Facilities. By reserching the National human Right Commitee's Anual Reports, three different indexes were picked out for those analysis : the Environmental control index, the Detention Service support index, the Environmental support index. These three indexes will be used as Key factors for the planning of interior architectural environments of the detention facilities at the Korean Police Stations.: (1)the Environmental control index to establish the Space Program, the Spatial Hierarchy and the horizontal & vertical Security Blocks, (2)the Detention Service support index for the central Environmental Control & Security System, the Secured Privacy for both detainees & police offices, (3)the Environmental support index for the gender-respected segregation of cell zones, the psychological & physical safety design factors, the construction standards of all rooms in a detention facility. The result of this study should be used as the guidelines for "The Standard Plans and Regulations for the Korean Police Detention Facilities" to respect fundamental human rights.

Estimation of Reliability Level and Applicability of LRFD Based on Standard Drawings of Railway Cantilever Retaining Walls (철도 옹벽 표준도의 신뢰도수준 및 LRFD 적용성 평가)

  • Kim, In-Soo;Lim, Heui-Dae;Park, Joon-Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.10
    • /
    • pp.61-76
    • /
    • 2015
  • Recently, geotechnical engineering researches have been conducted on the Limit State Design (LSD) for deep and shallow foundations; however, there are very few studies on the retaining wall. As a basic study for the introduction of the LSD of a railway retaining wall, this study evaluates whether the reliability index satisfies the target reliability index for each failure mode in the standard drawing of the retaining wall. It also analyzes the feasibility of the LSD method by using the Load and Resistance Factor Design (LRFD) for the standard drawing of a retaining wall. In a portion of the standard drawing of the railway retaining wall, the reliability indices of the sliding and bearing capacity failure modes did not satisfy the target reliability index, and could not satisfy the limit state by the LRFD. Hence, the standard drawing of the railway retaining wall will need to be revised if the LSD is to be applied.