• Title/Summary/Keyword: standard GA

Search Result 250, Processing Time 0.031 seconds

Feasibility study of improved particle swarm optimization in kriging metamodel based structural model updating

  • Qin, Shiqiang;Hu, Jia;Zhou, Yun-Lai;Zhang, Yazhou;Kang, Juntao
    • Structural Engineering and Mechanics
    • /
    • v.70 no.5
    • /
    • pp.513-524
    • /
    • 2019
  • This study proposed an improved particle swarm optimization (IPSO) method ensemble with kriging model for model updating. By introducing genetic algorithm (GA) and grouping strategy together with elite selection into standard particle optimization (PSO), the IPSO is obtained. Kriging metamodel serves for predicting the structural responses to avoid complex computation via finite element model. The combination of IPSO and kriging model shall provide more accurate searching results and obtain global optimal solution for model updating compared with the PSO, Simulate Annealing PSO (SimuAPSO), BreedPSO and PSOGA. A plane truss structure and ASCE Benchmark frame structure are adopted to verify the proposed approach. The results indicated that the hybrid of kriging model and IPSO could serve for model updating effectively and efficiently. The updating results further illustrated that IPSO can provide superior convergent solutions compared with PSO, SimuAPSO, BreedPSO and PSOGA.

Hysteresis characterization and identification of the normalized Bouc-Wen model

  • Li, Zongjing;Shu, Ganping
    • Structural Engineering and Mechanics
    • /
    • v.70 no.2
    • /
    • pp.209-219
    • /
    • 2019
  • By normalizing the internal hysteresis variable and eliminating the redundant parameter, the normalized Bouc-Wen model is considered to be an improved and more reasonable form of the Bouc-Wen model. In order to facilitate application and further research of the normalized Bouc-Wen model, some key aspects of the model need to be uncovered. In this paper, hysteresis characterization of the normalized Bouc-Wen model is first studied with respect to the model parameters, which reveals the influence of each model parameter to the shape of the hysteresis loops. The parameter identification scheme is then proposed based on an improved genetic algorithm (IGA), and verified by experimental test data. It is proved that the proposed method can be an efficacious tool for identification of the model parameters by matching the reconstructed hysteresis loops with the target hysteresis loops. Meanwhile, the IGA is shown to outperform the standard GA. Finally, a simplified identification method is proposed based on parameter sensitivity, which indicates that the efficiency of the identification process can be greatly enhanced while maintaining comparable accuracy if the low-sensitivity parameters are reasonably restricted to narrower ranges.

Optimization Condition for Injection Molding of TV Speaker Grille Using CAE (CAE를 이용한 TV Speaker Grille 사출 성형의 최적화)

  • 김범호;장우진;김정훈;정지원;박영훈
    • Polymer(Korea)
    • /
    • v.25 no.6
    • /
    • pp.855-865
    • /
    • 2001
  • The optimization condition of injection molding for a commercial product of TV speaker grille of A Company was induced using a CAE software of Moldflow. The flow and packing phase analysis was performed by using flow balance, runner balance, and the intermediate one by using the above two balances, which were used for controlling the amount of packing resins into the cavity, Later, the analysis performed by using the measured viscosity (local database) at various shear rates and the results were compared with the computer simulation using the standard database. Flow balance induced minimized weld line resulted in a better appearance and physical properties of the were line, but exhibited a disadvantage of large deformation and gas formation due to over-packing of the molten resin in the center of the speaker grille. Runner balance improved the disadvantage of the flow balance by controlling the amount of molten resin injected from the gate, however resulted reduced mechanical properties and poor appearance of the weld line. However, the modified method induced from the flow and runner balance improved the disadvantages by changing the runner size. In addition, the analyses based on the local database and the standard database were compared. Although the measured viscosity was slightly higher and the temperature distribution was broader than the standard database, no distinct difference was obtained from the analysis using the two different databases.

  • PDF

Study on the Development of a Standard Instrument of Diagnosis and Assessment for Spleen Qi Deficiency Pattern (脾氣虛證(비기허증) 진단평가도구 개발 연구)

  • Oh, Hye-Won;Lee, Ji-Won;Kim, Je-Shin;Song, Eun-Young;Shin, Seung-Won;Han, Ga-Jin;Lu, Huanyu;Lee, Jun-Hee
    • The Journal of Korean Medicine
    • /
    • v.35 no.1
    • /
    • pp.157-170
    • /
    • 2014
  • Objectives: The purpose of this study was to develop a standard instrument of diagnosis and assessment for spleen qi deficiency pattern. Methods: Reports published in Korea and China related to spleen qi deficiency pattern were selected. Assessments of selected references were performed to select major symptoms of spleen qi deficiency pattern. Korean translation and review by a Korean linguist were performed to create a draft of [Standard instrument of diagnosis and assessment for spleen qi deficiency (for subject)]. The final [Standard instrument of diagnosis and assessment for spleen qi deficiency (for subject)] was completed after assessment on inclusion or exclusion, on importance of items and on validity of translation by an expert committee, consisting of professors from the National College of Korean Medicine. Results & Conclusions: 1. 14 major symptoms were selected by frequency from 45 references which were related to standard identification of spleen qi deficiency pattern, translated into Korean and reviewed by a Korean linguist. 2. 11 symptoms were selected after assessment on inclusion yes or no by the expert group. Items were listed in order of importance: tiredness of extremities (肢体倦怠), sallow complexion (面色萎黃), reduced appetite (食欲减退), abdominal distension after eating (腹胀食後尤甚), inability to eat (納少), pale tongue and white fur (舌淡苔白), lethargy (神疲), emaciation (消瘦), loose stool (大便溏薄), shortness of breath and reluctance to speak (少氣懶言), and weak pulse (脈緩弱). 3. Final [Standard instrument of diagnosis and assessment for spleen qi deficiency (for subject)] was completed after assessment of translation validity, reflection of individual opinions by the expert committee, and application of weighted value computed from assessment on importance of items.

Characterization of Chemical Bath Deposited ZnS Thin Films and Its application to $Cu(InGa)Se_2$ Solar Cells (용액성장법에 의한 황화아연 박막층 분석 및 이의 CIGS 태양전지로의 응용)

  • Shin, Dong-Hyeop;Larina, Liudmila;Yun, Jae-Ho;Ahn, Byung-Tae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.138-138
    • /
    • 2009
  • Recently, thin-film solar cells of Cu(In,Ga)$Se_2$(CIGS) have reached a high level of performance, which has resulted in a 19.9%-efficient device. These conventional devices were typically fabricated using chemical bath deposited CdS buffer layer between the CIGS absorber layer and ZnO window layer. However, the short wavelength response of CIGS solar cell is limited by narrow CdS band gap of about 2.42 eV. Taking into consideration the environmental aspect, the toxic Cd element should be replaced by a different material. It is why during last decades many efforts have been provided to achieve high efficiency Cd-free CIGS solar cells. In order to alternate CdS buffer layer, ZnS buffer layer is grown by using chemical bath deposition(CBD) technique. The thickness and chemical composition of ZnS buffer layer can be conveniently by varying the CBD processing parameters. The processing parameters were optimized to match band gap of ZnS films to the solar spectrum and exclude the creation of morphology defects. Optimized ZnS buffer layer showed higher optical transmittance than conventional thick-CdS buffer layer at the short wavelength below ~520 nm. Then, chemically deposited ZnS buffer layer was applied to CIGS solar cell as a alternative for the standard CdS/CIGS device configuration. This CIGS solar cells were characterized by current-voltage and quantum efficiency measurement.

  • PDF

Feature Selecting Algorithm Development Based on Physiological Signals for Negative Emotion Recognition (부정감성 인식을 위한 생체신호 기반의 특징 선택 알고리즘 개발)

  • Lee, JeeEun;Yoo, Sun K.
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.8
    • /
    • pp.3925-3932
    • /
    • 2013
  • Emotion is closely related to the life of human, so has effect on many parts such as concentration, learning ability, etc. and makes to have different behavior patterns. The purpose of this paper is to extract important features based on physiological signals to recognize negative emotion. In this paper, after acquisition of electrocardiography(ECG), electroencephalography(EEG), skin temperature(SKT) and galvanic skin response(GSR) measurements based on physiological signals, we designed an accurate and fast algorithm using combination of linear discriminant analysis(LDA) and genetic algorithm(GA), then we selected important features. As a result, the accuracy of the algorithm is up to 96.4% and selected features are Mean, root mean square successive difference(RMSSD), NN intervals differing more than 50ms(NN50) of heart rate variability(HRV), ${\sigma}$ and ${\alpha}$ frequency power of EEG from frontal region, ${\alpha}$, ${\beta}$, and ${\gamma}$ frequency power of EEG from central region, and mean and standard deviation of SKT. Therefore, the features play an important role to recognize negative emotion.

Unsupervised Segmentation of Objects using Genetic Algorithms (유전자 알고리즘 기반의 비지도 객체 분할 방법)

  • 김은이;박세현
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.41 no.4
    • /
    • pp.9-21
    • /
    • 2004
  • The current paper proposes a genetic algorithm (GA)-based segmentation method that can automatically extract and track moving objects. The proposed method mainly consists of spatial and temporal segmentation; the spatial segmentation divides each frame into regions with accurate boundaries, and the temporal segmentation divides each frame into background and foreground areas. The spatial segmentation is performed using chromosomes that evolve distributed genetic algorithms (DGAs). However, unlike standard DGAs, the chromosomes are initiated from the segmentation result of the previous frame, then only unstable chromosomes corresponding to actual moving object parts are evolved by mating operators. For the temporal segmentation, adaptive thresholding is performed based on the intensity difference between two consecutive frames. The spatial and temporal segmentation results are then combined for object extraction, and tracking is performed using the natural correspondence established by the proposed spatial segmentation method. The main advantages of the proposed method are twofold: First, proposed video segmentation method does not require any a priori information second, the proposed GA-based segmentation method enhances the search efficiency and incorporates a tracking algorithm within its own architecture. These advantages were confirmed by experiments where the proposed method was success fully applied to well-known and natural video sequences.

The Effect of Electroacupuncture at Sobu(HT8) on the EEG and HRV (소부(HT8) 전침이 뇌파(EEG)와 심박변이도(HRV)에 미치는 영향)

  • Yoon, Dae Shik;Hong, Seung-Won;Lee, Yong-Sub
    • Korean Journal of Acupuncture
    • /
    • v.30 no.4
    • /
    • pp.305-318
    • /
    • 2013
  • Objectives : The aim of this study was to examine the effect of electroacupuncture(EA) at an acupoint, HT8(Sobu), on normal humans by using power spectral analysis. We examined the effect on the Heart Rate Variability(HRV), and the balance of the autonomic nervous system. Methods : Thirty-two healthy volunteers participated in this study. EEG(Electroencephalogram) power spectrum exhibits site-specific and state-related differences in specific frequency bands. A thirty-two channel EEG study was carried out on thirty-two subjects(14 males; mean age=23.5 years old, 18 females; mean age=21.5 years old). HRV and EEG were simultaneously recorded before and after acupuncture. Results : In the ${\alpha}$(alpha) band, during the HT8-acupoint treatment, the power values in the ${\alpha}$(alpha) band significantly decreased(p<0.05) at 28 channels. In the ${\beta}$(beta) band significantly decreased(p<0.05) at 26 channels. In ${\delta}$(delta) band significantly decreased(p<0.05) at 18 channels. In ${\theta}$(theta) band significantly decreased(p<0.05) at 20 channels. ${\alpha}/{\beta}$ values were increased at 6 channels and decreased at 10 channels.${\beta}/{\theta}$ values were increased at 10 channels and decreased at 19 channels. Mean-RR(RR-interval), Complexity, RMSSD(Root mean square of successive differences), SDSD(Standard deviations differences between adjacent normal R-R intervals), norm HF showed a significantly increased and mean-HRV, norm LF, LHR(LF/HF Ratio) showed a significantly decreased after HT8-acupoint treatment(p<0.05). Conclusions : These results suggest that EA at the HT8 mostly causes significant changes on alpha(28 channels), beta(26 channels), delta(18 channels), theta(20 channels) bands and mean-HRV, mean-RR, complexity, RMSSD, SDSD, norm LF, norm HF and LHR. If practicing EA at the HT8, it will regulate the function of the cerebral cortex, decrease activity of the sympathetic and increase parasympathetic nervous activity.

The Effect of Laser Therapy for Diabetic Ulcer : Systematic Review (당뇨병성 궤양의 레이저치료에 대한 효과 : 체계적 문헌고찰)

  • Kang, Ki-Wan;Kang, Ja-Yeon;Jeong, Min-Jeong;Kim, Hong-Jun;Seo, Hyung-Sik;Jang, In-Soo
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.30 no.4
    • /
    • pp.62-74
    • /
    • 2017
  • Objectives : The purpose of this study is to investigate the effect of laser therapy for diabetic ulcer by using methods of systematic review. Methods : In this review, PubMed, Cochrane library, Web of Science, CNKI, CiNii, J-STAGE, NDSL and OASIS were used as the search engines. The search period is from the start date of the search engine to October 3, 2016. Randomized controlled trials(RCTs) using laser therapy for diabetic ulcer were searched and extracted by two independent researchers. Risk of bias(RoB) of Cochrane was used to assess methodological quality of studies. Results : Finally, five RCTs were selected. The follow-up period ranged from 15 days to 20 weeks. InGaAlP laser, GaAlAs laser and light emitting diode(LED) were used to treat diabetic ulcer. The clinical trials used sham laser irradiation or standard treatment as control in comparison to laser therapy. The endpoints included ulcer size, rate of healing and time to healing with follow-up period. The RCTs demonstrated therapeutic outcomes with no adverse effect. Most items of RoB were unclear and methodological quality was low. Conclusions : Our analysis suggests that laser therapy has therapeutic effects for diabetic ulcer. However, more systematic and stringent clinical trials will be required.

The Design of Feature Selecting Algorithm for Sleep Stage Analysis (수면단계 분석을 위한 특징 선택 알고리즘 설계)

  • Lee, JeeEun;Yoo, Sun K.
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.10
    • /
    • pp.207-216
    • /
    • 2013
  • The aim of this study is to design a classifier for sleep stage analysis and select important feature set which shows sleep stage well based on physiological signals during sleep. Sleep has a significant effect on the quality of human life. When people undergo lack of sleep or sleep-related disease, they are likely to reduced concentration and cognitive impairment affects, etc. Therefore, there are a lot of research to analyze sleep stage. In this study, after acquisition physiological signals during sleep, we do pre-processing such as filtering for extracting features. The features are used input for the new combination algorithm using genetic algorithm(GA) and neural networks(NN). The algorithm selects features which have high weights to classify sleep stage. As the result of this study, accuracy of the algorithm is up to 90.26% with electroencephalography(EEG) signal and electrocardiography(ECG) signal, and selecting features are alpha and delta frequency band power of EEG signal and standard deviation of all normal RR intervals(SDNN) of ECG signal. We checked the selected features are well shown that they have important information to classify sleep stage as doing repeating the algorithm. This research could use for not only diagnose disease related to sleep but also make a guideline of sleep stage analysis.