• 제목/요약/키워드: standalone

검색결과 213건 처리시간 0.014초

독립형 태양광 가로등의 실시간 분석기술 개발을 위한 실태조사 (A Field State Investigation on Standalone PV streetlight for Development of Real-time Analysis Technology)

  • 김두현;김성철;황동규
    • 한국안전학회지
    • /
    • 제28권5호
    • /
    • pp.10-14
    • /
    • 2013
  • This paper is aimed to investigate the actual conditions of standalone PV(Photovoltaics) streetlight in public place and analyze cause of failure and derive the method of decrease for standalone PV streetlight. The cost of installing standalone PV streetlight in a public for the safety and convenience of life is expensive(300 million won per unit). Management of standalone PV streetlight is important because it is operating system itself, after installation, but concern degree of management is very low and development of technology has not been done. Accordingly, standalone PV streetlight in public place is not operate in night, this phenomenon is lasted for several days to months. Therefore this study, for standalone PV streetlight constantly to keep the normal operation, investigation conducted to check status of standalone PV streetlight(50 units), the voltage of the main parts and analyze the cause of the failure. In addition, the improvement of standalone PV streetlight is suggested by using FTA(fault tree analysis).

Dynamic Analysis and Controller Design for Standalone Operation of Photovoltaic Power Conditioners with Energy Storage

  • Park, Sun-Jae;Shin, Jong-Hyun;Park, Joung-Hu;Jeon, Hee-Jong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2004-2012
    • /
    • 2014
  • Energy storage devices are necessary to obtain stable utilization of renewable energy sources. When black-out occurs, distributed renewable power sources with energy storage devices can operate under standalone mode as uninterruptable power supply. This paper proposes a dynamic response analysis with small-signal modeling for the standalone operation of a photovoltaic power generation system that includes a bidirectional charger/discharger with a battery. Furthermore, it proposes a DC-link voltage controller design of the entire power conditioning system, using the storage current under standalone operation. The purpose of this controller is to guarantee the stable operation of the renewable source and the storage subsystem, with the power conversion of a very efficient bypass-type PCS. This paper presents the operating principle and design guidelines of the proposed scheme, along with performance analysis and simulation. Finally, a hardware prototype of 1-kW power conditioning system with an energy storage device is implemented, for experimental verification of the proposed converter system.

열전소자를 이용한 차량용 독립 냉난방시스템에 대한 실험적 연구 (Experimental Study of Standalone Cooling and Heating System using Thermoelectric Element for Vehicles)

  • 이대웅
    • 설비공학논문집
    • /
    • 제26권8호
    • /
    • pp.375-380
    • /
    • 2014
  • The purpose of this paper is to investigate the cooling and heating performance of a standalone-type thermoelectric system equipped with a thermoelectric module. The system consists of a blower and two thermoelectric modules with a fin, which is soldered onto both sides of the thermoelectric module and a courtesy light. The thermoelectric system experiment is conducted with the intake voltage to find the optimum cooling and heating performance of each. The results showed that the cooling capacity and coefficient of performance (COP) were 22 W and 0.31, and the heating capacity and COP were 147 W and 1.1, respectively. In the vehicle cooling and heating performance test in a climate wind tunnel, the results showed that the standalone thermoelectric system's cooling performance was slightly better than the base system; and the heating performance of the standalone thermoelectric system was $54.1^{\circ}C$ and the COP was 1.3, compared to the base system.

Real-time Object Recognition with Pose Initialization for Large-scale Standalone Mobile Augmented Reality

  • Lee, Suwon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제14권10호
    • /
    • pp.4098-4116
    • /
    • 2020
  • Mobile devices such as smartphones are very attractive targets for augmented reality (AR) services, but their limited resources make it difficult to increase the number of objects to be recognized. When the recognition process is scaled to a large number of objects, it typically requires significant computation time and memory. Therefore, most large-scale mobile AR systems rely on a server to outsource recognition process to a high-performance PC, but this limits the scenarios available in the AR services. As a part of realizing large-scale standalone mobile AR, this paper presents a solution to the problem of accuracy, memory, and speed for large-scale object recognition. To this end, we design our own basic feature and realize spatial locality, selective feature extraction, rough pose estimation, and selective feature matching. Experiments are performed to verify the appropriateness of the proposed method for realizing large-scale standalone mobile AR in terms of efficiency and accuracy.

임계온도스위치를 이용한 저전력 단독경보형 정온식 감지기 개발 (Development of a Low-Power Standalone Heat Detector Using a Critical-Temperature Switch)

  • 조성우;정순규;손지민;김현탁
    • 한국화재소방학회논문지
    • /
    • 제33권4호
    • /
    • pp.70-76
    • /
    • 2019
  • 본 연구에서는 임계온도스위치를 이용하여 저전력 단독경보형 정온식 감지기를 개발하였다. 임계온도스위치는 70 ℃에서 저항이 급격하게 감소하는 특성을 나타내는 소자로, 금속-절연체 전이 현상을 이용함으로써 온도 측정에 대한 높은 신뢰성을 보장한다. 또한 임계온도스위치의 금속에서 절연체로 변하는 디지털적인 특성을 이용하여 마이크로컨트롤러 사용 없이 화재를 감지함으로써 단독경보형 정온식 감지기의 소비 전력을 최소화하였다. 시험결과 임계온도스위치를 이용한 단독경보형 정온식 감지기는 소방청 고시 단독경보형 정온식 감지기 시험 조건을 만족했으며, 소비 전력을 측정한 결과 기존 제품 대비 70%의 전력만으로 화재를 감지함을 확인하였다.

디젤발전기가 포함된 독립형 마이크로그리드에서의 BESS 제어기법 및 운전모드 연구 (Control and Operating Modes of Battery Energy Storage System for a Stand-Alone Microgrid with Diesel Generator)

  • 조종민;안현성;김지찬;차한주
    • 전력전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.86-93
    • /
    • 2018
  • In this work, control methods and operating modes are proposed to manage standalone microgrid. A standalone microgrid generally consists of two sources, namely, battery energy storage system (BESS) and diesel generator (DG). BESS is the main source that supplies active and reactive power regardless of load conditions, whereas DG functions as an auxiliary power source. BESS operates in a constant voltage constant frequency (CVCF) control, which includes proportional-integral + resonant controller in a parallel structure. In CVCF control, the concept of fundamental positive and negative transformation is utilized to generate a three-phase sinusoidal voltage under imbalanced load condition. Operation modes of a standalone microgrid are divided into three modes, namely, normal, charge, and manual modes. To verify the standalone microgrid along with the proposed control methods, a demonstration site is constructed, which contains 115 kWh lead-acid battery bank, 50 kVA three-phase DC - AC inverter, and 50 kVA DG and controllable loads. In the CVCF control, the total harmonic distortion of output voltage is improved to 1.1% under imbalanced load. This work verifies that the standalone microgrid provides high-quality voltage, and three operation modes are performed from the experimental results.

럭셔리 패션 브랜드 팝업매장에서의 소비자 체험, 이미지 인식, 구전의도 간의 관계에 관한 연구 - 독립형과 백화점 입점형 팝업매장을 중심으로 - (The relationship between consumer experience, image perception, and word-of-mouth intention in standalone pop-up stores and pop-ups within department stores)

  • 박주영;박인형;오예우;정재은
    • 복식문화연구
    • /
    • 제32권2호
    • /
    • pp.260-286
    • /
    • 2024
  • This study investigates consumer experiences and word-of-mouth (WOM) intentions in luxury brand pop-up stores, including standalone and department store setups. Grounded in experience economy theory, this study examines the experiential elements based on the types of pop-up stores and the relationships among consumer experience, pop-up store image, and WOM intentions for each type. Data were collected from 300 visitors to luxury brand pop-up stores between January and July 2023 and analyzed using Smart PLS 4.0. The findings reveal several key insights. First, standalone pop-up stores offer educational and escapist experiences, while pop-ups within department stores have a single identified factor of consumer experience. Second, regardless of the store type, luxury pop-up store experiences significantly influence pop-up image perceptions. Third, luxury pop-up store image drives WOM intentions for both standalone and department store pop-ups. Notably, the unique image significantly impacts solely department store pop-ups and does not influence standalone pop-ups. Moreover, image perceptions in both pop-up store types do not significantly affect brand WOM intentions. Finally, WOM intentions for pop-up stores significantly influence WOM intentions for brands. This study contributes to the theoretical understanding of consumer experiences in luxury pop-up stores, providing practical insights for stakeholders in the luxury brand industry to enhance pop-up store image perceptions and WOM intentions.

Single Sensor Charging System with MPPT Capability for Standalone Streetlight Applications

  • Osman, Siti Rahimah;Rahim, Nasrudin Abd.;Selvaraj, Jeyraj;Al-Turki, Yusuf A.
    • Journal of Power Electronics
    • /
    • 제15권4호
    • /
    • pp.929-938
    • /
    • 2015
  • Maximum power point tracking (MPPT) and battery charging control are two important functions for a solar battery charger. The former improves utilization of the available solar energy, while the latter ensures a prolonged battery life. Nevertheless, complete implementation of both functions can be complex and costly, especially for low voltage application such as standalone street lamps. In this paper, the operation of a solar battery charger for standalone street light systems is investigated. Using only one voltage sensor, the solar charger is able to operate in both MPPT and constant voltage (CV) charging mode, hence providing high performance at a low cost. Using a lab prototype and a solar simulator, the operation of the charger system is demonstrated and its performance under varying irradiance is validated.

SBAS 이동측위 정확도 분석 (Accuracy Analysis of Kinematic SBAS Surveying)

  • 김혜인;손은성;이호석;김현호;박관동
    • 한국측량학회지
    • /
    • 제26권5호
    • /
    • pp.493-504
    • /
    • 2008
  • SBAS(Space-Based Augmentation System)는 광역보정항법시스템(WADGPS, Wide Area DGPS)으로써 지역 보정항법시스템(LADGPS, Local Area DGPS)의 단점을 보완한 위성항법 보정시스템이다. 이 연구에서는 GPS 측위의 대표적인 방법인 실시간 이동측위(RTK; Real-Time Kinematic), DGPS(Differential GPS) 측위, 단독측위(Standalone)와 SBAS 이동측위를 실시하고 그에 따른 측위 정확도 비교를 통해 SBAS 이동측위의 성능을 분석하였다. 정지측위 결과 산출한 좌표를 참값으로 간주하였고, 각각의 측위방법으로 획득한 관측데이터를 참값과 비교하여 계산한 2차원 평균제곱근(RMS: Root Mean Square)오차와 3차원 RMS 오차를 정확도 비교의 지표로 사용하였다. 그 결과, 각 측위방법에 따른 3차원 RMS 오차는 RTK 측위 13.1cm, DGPS 측위 126.0cm, 이중주파수 단독측위 135.7cm, 단일주파수 단독측위 428.9cm, 그리고 SBAS 측위 109.2cm로 나타났다. 이를 통해 SBAS 측위의 정확도가 DGPS 측위 정확도와 대등한 수준임을 확인할 수 있었다.

독립형 태양광 발전 시스템의 무정전 전력공급을 위한 시스템 용량 최적 선정에 관한 연구 (A Study on the Optimal System Sizing of the Standalone Photovoltaic Power Generation System for Uninterruptible Power Supply)

  • 김기영;최우진
    • 전력전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.77-85
    • /
    • 2018
  • Renewable energy has been increasingly used and widely acclaimed as one of the solutions to rampant environmental problems. Among numerous kinds of renewable sources, the penetration rate of the PV system is relatively higher than that of others due to ease of installation. However, one disadvantage of the PV system is its dependence on weather condition. The PV system is especially critical when it is used for standalone systems because it cannot operate when the power generated from a PV module is not enough. Therefore, PV systems are often used with an energy storage system, such as batteries, to store backup energy when the weather condition is insufficient to supply power to the system. Blackout time can be reduced by increasing the size of the energy storage system, but it is a trade-off with system cost. In this work, optimal sizing of a standalone PV system is proposed to supply power to the system without blackout. The sizing of PV modules and batteries is performed by a simulation based on actual irradiation data collected during the past five years. The Life cycle costing of each system is evaluated to determine an optimal set of PV modules and batteries among several different combinations. The standalone PV system designed by the proposed method can supply power to the system with no interruption as long as the weather condition is similar to those of the past five years.