• Title/Summary/Keyword: stainless coating

Search Result 204, Processing Time 0.025 seconds

Wettability Characteristics of the Laser Grooved Surfaces (Laser Groove 표면의 젖음 특성에 관한 연구)

  • Jang, Mu Yeon;Kim, Tae Wan
    • Tribology and Lubricants
    • /
    • v.35 no.5
    • /
    • pp.294-299
    • /
    • 2019
  • Most previous studies on water repellent surfaces using lasers rely on the use of pico- or femtosecond lasers. However, in industrial application, these methods have the disadvantages of high cost and low efficiency. In this study, we implement a hydrophobic surface using a high-power general-purpose diode laser. We have fabricated the microsurface using laser groove processing technology, and we present the correlation of wettability characteristics with space and width. The metal material is stainless steel (SUS 304), and the groove height during laser processing is set to $30{\mu}m$ to evaluate the wettability based on the gap and width of various grooves. Results show that the contact angle of the groove-shaped surface is increased by $40^{\circ}$ or more as compared with the surface without patterning, and the contact angle in the parallel direction is greater than that in the perpendicular direction. Results from contact angle hysteresis measurement experiments show that the groove width has a greater influence on the contact angle history than does the gap between grooves. In addition, the coating reveals that the contact angle can be increased using a chemical method and that the laser grooving process can further improve the wetting properties of the surface.

Performance evaluation of plasma nitrided 316L stainless steel during long term high temperature sodium exposure

  • Akash Singh;R. Thirumurugesan;S. Krishnakumar;Revati Rani;S. Chandramouli;P. Parameswaran;R. Mythili
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1468-1475
    • /
    • 2023
  • Enhancement of wear resistance of components used in fast reactors is necessary for long service life of the components. Plasma nitriding is a promising surface modification technology to impart high hardness and improved wear resistance of various steel components. This study discusses the characterization of chrome nitrided SS316L casing ring used in secondary sodium pump of fast breeder reactor and its stability under long term sodium exposure. Microstructural and hardness analysis showed that stress relieved component could be chrome nitrided successfully to a thickness of about 100 ㎛. Assessment of in-sodium performance of the chrome nitrided casing ring subjected to long term exposure up to 5000h at 550℃, showed retention of chrome nitrided layer with a case depth almost similar to that before sodium exposure. A slight decrease in the hardness was observed due to prolonged high temperature sodium exposure. Tribological studies indicate very low coefficient of friction indicating the retention of good wear resistance of the coating even after long term sodium exposure.

Development of Surface Coating Technology fey Metallic Bipolar Plate in PEMFC : I. Study on Surface and Corrosion Properties (PEMFCB금속분리판 코팅 기술 개발 : I. 표면 및 부식 특성 평가)

  • Chung, Kyeong-Woo;Kim, Se-Yung;Yang, Yoo-Chang;Ahn, Seung-Gyun;Jeon, Yoo-Taek;Na, Sang-Mook
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.348-351
    • /
    • 2006
  • Bipolar plate, which forms about 50% of the stack cost, is an important core part with polymer electrolyte membrane in PEMFC. Bipolar plates have been commonly fabricated from graphite meterial having high electrical conductivity and corrosion resistance. Lately, many researchers have concentrated their efforts on the development of metallic bipolar plate and stainless steel has been considered as a potential material for metallic bipolar plate because of its high strength, chemical stability, low gas permeability and applicability to mass production. However, it has been reported that its inadequate corrosion behavior under PEMFC environment lead to a deterioration of membrane by dissolved metal ions and an increase in contact resistance by the growth of passive film therefore, its corrosion resistance as well as contact resistance must be improved for bipolar plate application. In this work, several types of coating were applied to 316L and their electrical conductivity and corrosion resistance were evaluated In the simulated PEMFC environment. Application of coating gave rise to low interfacial contact resistances below $19m{\Omega}cm^2$ under the compress force of $150N/cm^2$. It also made the corrosion potential to shift in the posit ive direct ion by 0.3V or above and decreased the corrosion current from ca. $9{\mu}A/cm^2$ to ca. $0.5{\mu}A/cm^2$ in the mixed solution of $0.1N\;N_2SO_4$ and 2ppm HF A coat ing layer under potentiostatic control of 0.6V and $0.75V_{SCE}$ for 500 hours or longer showed some instabilities, however, no significant change in coat Ing layer were observed from Impedance data. In addition, the corrosion current maintained less than $1{\mu}A/cm^2$ for most of time for potentiostatic tests. It indicates that high electrical conductivity and corrosion resistance can be obtained by application of coatings in the present work.

  • PDF

The study on collection efficiency of two-stage electrostatic precipitator using non-metallic electrode for improve corrosion resistance and light weight (내부식성과 경량성 향상을 위한 비금속 재질 집진판의 2단 전기집진기 집진효율 연구)

  • An, So-Hee;Lee, Yeawan;Kim, Ye-Sle;Kim, Yong-Jin;Han, Bangwoo;Kim, Hak-Joon
    • Particle and aerosol research
    • /
    • v.17 no.2
    • /
    • pp.21-27
    • /
    • 2021
  • We developed non-metallic electrodes that can replace metallic electrodes of the electrostatic precipitator(ESP) for the purpose of light weight, corrosion resistance, cost reduction. We manufactured three types of collection electrodes made of stainless steel (M), Carbon ink coating layer-Plastic sheet-Carbon ink coating layer (CPC), and Plastic sheet-Carbon ink coating layer-Plastic sheet (PCP). We studied the collection efficiency of a two-stage ESP using oil mist particles with and without collection stage by changing the flow rate, the material of collection electrode, and the applied voltage of the pre-charger module and the collection module. Here we measured concentrations of particles at diameters of 0.45 ㎛ (CMD; count median diameter) and 3.0 ㎛ (MMD : mass median diameter), as well as PM2.5 and PM10. As a result of the experiment, two-stage ESP had 22~25% higher collection efficiency in PM2.5 than one-stage ESP at the same applied voltage. The difference in collection efficiency by varying the materials of collection electrodes was less than 5%. The weight of the non-metallic electrode was only one eighth the weight of the metal electrode. CPC electrode had a thickness of 0.27 mm, which was 1.5 times thinner than a thickness of PCP electrode, so when the flow rate increased, the CPC electrodes couldn't be kept at equal intervals due to the fluttering unlike PCP electrodes. In addition, the PCP-CPC collection module of the present experiment followed the theoretical efficiency based on Deutsch equation and Cochet's charging theory.

Limitation of Nitrogen ion Implantation and Ionplating Techniques Applied for Improvement of Wear Resistance of Metallic Implant Materials (금속 임플란트 소재의 내마모성 향상을 위하여 적용되는 질소 이온주입 및 이온도금법의 한계)

  • 김철생
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.157-163
    • /
    • 2004
  • Nitrogen ion implantation and ion plating techniques were applied for improvement of the wear resistance of metallic implant materials. In this work, the wear dissolution behaviour of a nitrogen ion implanted super stainless steel (S.S.S, 22Cr-20Ni-6Mo-0.25N) was compared with those of S.S.S, 316L SS and TiN coated 316L SS. The amounts of Cr and Ni ions worn-out from the specimens were Investigated using an electrothermal atomic absorption spectrometry. Furthermore, the Ti(Grade 2) disks were coated with TiN, ZrN and TiCN by use of low temperature arc vapor deposition and the wear resistance of the coating layers was compared with that of titanium. The chemical compositions of the nitrogen ion implanted and nitride coated layers were examined with a scanting auger electron spectroscopy. It wat observed that the metal ions released from the nitrogen ion implanted S.S.S surface were significantly reduced. From the results obtained, it was shown that the nitrogen ion implanted zone obtained with 100 KeV ion energy was easily removed within 200,000 revolutions from a wear dissolution testing under a similar load condition when applied to artificial hip joint. The remarkable improvement in wear resistance weir confirmed by the nitrides coated Ti materials and the wear properties differ greatly according to the chemical composition of the coating layers. for specimens with the same coating thickness of about 3$\mu\textrm{m}$, TiCN coated Ti showed the highest wear resistance. However, after removing the coating layers, the wear rates of all nitrides coated Ti reverted to their normal rates of below 10,000 revolutions from Ti-disk-on-disk wear testing under the same load condition. From the results obtained, it is suggested that the insufficient depth of the 100 Kel N$\^$+/ ion implanted zone and of the nitrides coated layers of 3$\mu\textrm{m}$ are subject to restriction when used as frictional parts of load bearing implants.

The Fabrication of HCD Ion Plating Apparatus and XPS Analysis on the Fine Color Changes of TiN Films on Stainless Steel (HCD 이온플레이팅 장치 제작 및 Stainless Steel 위에 TiN 박막의 미세색상변화에 따른 XPS분석)

  • Park, Moon Chan;Lee, Jong Geun;Choi, Kwang Ho;Cha, Jung Won;Kim, Eung Soon;Park, Jin Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.4
    • /
    • pp.361-366
    • /
    • 2010
  • Purpose: HCD ion plating apparatus by hollow cathod discharge method was fabricated and TiN films were deposited on stainless steel by this apparatus with increasing in $N_2$ gas flow and the fine color changes of TiN films were analyzed. Methods: The spectroradiometer and spectrophotometer were used to observe optically the fine color changes of TiN thin films, and XPS was used to analyze the compositions of TiN thin films with increasing in $N_2$ gas flow. Results: The color coordinate of TiN thin film with $N_2$ 120 sccm gas flow showed (0.382, 0.372) which had the mixed colors of gold and silver, and the color coordinate changed to the increasing value of (x,y) with increasing in $N_2$ gas flow which indicated the deep gold color. It was found that the slopes of the reflectances at 550nm were increased with increasing in $N_2$ gas flow. And from the Ti scans using XPS, it was found that the peak heights of 455 eV derived from TiN composition were increased with increasing in $N_2$ gas flow, while the peak heights of 459 eV from $TiO_2$ composition were decreased. Conclusions: The results obtained above were that the color of TiN film with 120 sccm $N_2$ gas flow had been observed from the mixed color of silver and gold due to TiC, $N_2$, TiN on the surface and TiN, $N_2$ inside film, and the color of TiN films changed a deep gold color with increasing in $N_2$ gas flow due to increasing TiN composition.

Evaluation of Titanium-nitride Coated Crown: Surface Hardness, Corrosion Resistance and Color Sustainability (타이타늄-질소 코팅된 금속관에 대한 평가: 표면 경도, 부식 저항성, 색조 안정성)

  • Kim, Hyojin;Lim, Sumin;Kim, JinYoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.3
    • /
    • pp.344-351
    • /
    • 2021
  • The purpose of this study was to compare surface hardness between titanium-nitride coated crowns (TiNCs) and stainless steel crowns (SSCs), and to evaluate the corrosion resistance and color sustainability of TiNCs. Ten TiNCs and 10 SSCs were used for the hardness test. Measurement was performed 30 times for each type of crowns, and the mean values were compared. Metallic raw material plates (before being processed into crowns) of TiNCs and SSCs were prepared for the corrosion resistance test. The total amounts of metal ion releases in the test solution were detected by inductively coupled plasma-optical emission spectrometry. Five TiNCs were subjected to the color sustainability test by applying repetitive brushing forces. The mean hardness values of TiNC group and SSC group were 395.53 ± 105.90 Hv and 278.70 ± 31.45 Hv respectively. Hardness of TiNCs were significantly higher than that of SSCs. The total amounts of metal ion releases from the materials of TiNCs and SSCs satisfied the criterion in International Organization for Standardization 22674. The results mean that TiNCs and SSCs were not harmful in an acidic environment. The golden coating was stable against the repetitive physical stimulations for a given period time.

Metal Surface Coating Using Electrospray of Biodegradable Polymers and $\alpha$-Lipoic Acid Release Behavior for Drug-Eluting Stents (생분해성 고분자의 전기분사를 이용한 약물방출 스텐트용 금속표면 코팅 및 ALA방출 거동)

  • Kim, Dong-Min;Lee, Bong-Soo;Park, Cheol-Ho;Park, Kwi-Deok;Son, Tae-Il;Jeong, Myeong-Ho;Han, Dong-Keun
    • Polymer(Korea)
    • /
    • v.34 no.2
    • /
    • pp.178-183
    • /
    • 2010
  • Medical metal stents inserted to patients with a cardiovascular disease associated with coronary artery system have relatively increased the survival rate. The development of new stents is, however, urgently required due to restenosis and late thrombosis generated in metal stents. To solve these problems, the biodegradable polymers such as poly(lactide-co-glycolide) (PLGA), poly(L-lactide)(PLLA), and poly ($\varepsilon$-caprolactone)(PCL) were mixed with alpha lipoic acid (ALA), which is well known to inhibit the proliferation of neointimal hyperplasia. Subsequently, the ALA-loaded polymers were coated on stainless steel by electrospray. The drug-eluting behaviors from the coated polymers were investigated according to kinds and concentrations of polymers, spray rates, and kinds of solvents. The drug-eluting rate from PCL with the lowest glass transition temperature was the fastest among three polymers and followed by PLGA and PLLA. The surface roughness increased as the spray rate was increased and also the drug-eluting rate was affected by kinds of solvents with different boiling point. It is expected that drug-eluting stent (DES) coated with ALA-loaded polymers can be applied practically for clinical applications by controlling the behavior of drug release.

Effect of Coating Materials for Steel on the Threshold of Corrosive Amount of Airborne Chlorides and the Evaluation of Their Corrosion Speeds (강재마감별 부식개시 임계 비래염분량 및 부식속도 평가)

  • Cho, Gyu-Hwan;Lim, Myung-Hyun;Park, Dong-Cheon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.2
    • /
    • pp.143-151
    • /
    • 2015
  • Many studies have investigated the airborne chlorides that can weaken the overall durability of the concrete structures due to the corrosion of steel materials, but most of the studies have aimed to examine weathering by exposing various construction materials to the actual oceanic environment. However, with the exposure test, it was difficult to find the threshold of precise corrosive amount of airborne chlorides due to diverse deteriorating environmental factors such as ultraviolet ray, acid rain, floating material from industrial pollution as well as airborne chlorides. Therefore, in this study, an airborne chloride simulator was set up, in oder to conduct a corrosion accelerating test for steels coated by five different finishing materials. As results, it was found that the corrosion began to be observed at $0.58{\sim}0.73mg/dm^2$ for no-coated steel, at $7.89{\sim}8.46mg/dm^2$for urethane-coated steel, at $57.95{\sim}69.48mg/dm^2$ for red lead-coated steel, and at $80.73{\sim}89.35mg/dm^2$ for stainless-coated steel, respectively. Hence, these specific data can be considered as the threshold ranges of corrosion for each coating material for steel.

Effect of Interlayer on TiN and CrN Thin Films of STS 420 Hybrid-Deposited by AlP and DC Magnetron Sputtering (AIP 와 스퍼터링으로 복합증착된 420 스테인리스강의 TiN과 CrN 박막에 미치는 중간층의 영향)

  • Choi, Woong-Sub;Kim, Hyun-Seung;Park, Burm-Su;Lee, Kyung-Ku;Lee, Doh-Jae;Lee, Kwang-Min
    • Korean Journal of Materials Research
    • /
    • v.17 no.5
    • /
    • pp.256-262
    • /
    • 2007
  • Effects of interlayer and the combination of different coating methods on the mechanical and corrosion behaviors of TiN and CrN coated on 420 stainless steel have been studied. STS 420 specimen were tempered at $300^{\circ}C$ for 1 hr in vacuum furnace. The TiN and CrN thin film with 2 ${\mu}m$ thickness were coated by arc ion plating and DC magnetron sputtering following the formation of interlayer for pure titanium and chromium with 0.2 ${\mu}m$ thickness. The microstructure and surface analysis of the specimen were conducted by using SEM, XRD and roughness tester. Mechanical properties such as hardness and adhesion also were examined. XRD patterns of TiN thin films showed that preferred TiN (111) orientation was observed. The peaks of CrN (111) and $Cr_2N$ (300) were only observed in CrN thin films deposited by arc ion plating. Both TiN and CrN deposited by arc ion plating had the higher adhesion and hardness compared to those formed by magnetron sputtering. The specimen of TiN and CrN on which interlayer deposited by magnetron sputtering and thin film deposited by arc ion plating had the highest adhesion with 22.2 N and 19.2 N. respectively. TiN and CrN samples shown the most noble corrosion potentials when the interlayers were deposited by using magnetron sputtering and the metal nitrides were deposited by using arc ion plating. The most noble corrosion potentials of TiN and CrN were found to be approximately -170 and -70 mV, respectively.