• Title/Summary/Keyword: stacking test

Search Result 200, Processing Time 0.024 seconds

Assessment of Hand Function in Spastic and Athetoid Cerebral Palsied Children by Jebsen Hand Function Test (경련성과 무정위성 뇌성마비 아동의 Jebsen Hand Function Test에 의한 손기능 평가)

  • Lee, Cu-Rie;Lee, Mi-Ja
    • Journal of Korean Physical Therapy Science
    • /
    • v.3 no.2
    • /
    • pp.981-987
    • /
    • 1996
  • Hand function evaluations are an important element of the assessment process in physical rehabilitation settings. The purpose of this study was to investigate hand function evaluation. Subjects consisted of 20 with spastic cerebral palsy(mean age = 9.8, SD = 1.6) and 20 with athetoid cerebral palsy(mean age = 9.6, SD = 2.3). Two groups of subjects were tested twice(pretest and posttest) by the JHFT to measure evaluations of hand function. These findings suggest that on four subtests - writing, card turning, large heavy objects and Stacking Checker-the spastic cerebral palsy perform significantly faster than athetoid cerebral palsy. But there were no significant differences between the pretest and posttest in spastic and athetoid cerebral palsy. To see the statistical differences in the experimental results was done using origin V. 3.0.

  • PDF

Fracture Behavior of a Stacked Concrete Structure Based on the Fracture Mechanics (적층한 콘크리트 복합구조체의 파괴역학적 거동)

  • Kim, Sang-Chul;Kim, Yeon-Tae
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.119-127
    • /
    • 1999
  • The objective of this study is to simulate the fracture behavior of composite structure bonded with more than 2 different cementitious materials. For this, concrete and cement were stacked and bonded in a direction perpendicular to loading and specimens were tested. Each constituent material of concrete and cement was fabricated independently also, and three point bending and indirect tensile tests were carried out for the acquisition of measured values applicable to the proposed model. As a result of comparing theoretical results and experimental ones, it was found that the proposed model derived from fictitious crack theory can be used to predict the fracture behavior of composite structures on the vases of well agreement with experimental results. It was also noted that the degree of improvement of fracture energies and strengths is greatly dependent on the stacking sequence of layers composing of a composite structure. Thus, it can be concluded that brittleness or ductility of a composite structure can be accomplished by a proper arrangement of layers on one's purpose throughout the proposed analysis.

A Study on Characterization for Stacking Fault Evaluation of CFRP Composite Laminates Using an EMAT Ultrasonics (전자기 초음파를 이용한 CFRP 복합적층판의 적층배향 특성평가에 관한 연구)

  • Im, Kwang-Hee;Na, Seung-Woo;Kim, Ji-Hoon;Lee, Chang-Ro;Hsu, David K.;Yang, In-Young
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.2
    • /
    • pp.83-92
    • /
    • 2005
  • An electromagnetic acoustic transducer (EMAT) is a unique probe that does not require a couplant or gel and also can usually generate or detect an ultrasonic wave into specimens across a small gap. It, therefore can be applied in a noncontact mode with a high degree of reproducibility. Especially stiffness of composites depends on layup sequence of CFRP(carbon fiber reinforced plastics) laminates. It is very important to evaluate the layup errors in prepreg laminates. A nondestructive technique can therefore serve as a useful measurement for detecting layup errors. This shear wave for detecting the presence of the errors is very sensitive. A decomposition model has been used in the interpretation and prediction of test results. Test results have been com pared with model data. It is found that the high probability shows between tests and the model utilized in characterizing cured layups of the laminates. Also a C-scan method was used for detecting layup of the laminates because of extracting fiber orientation information from the ultrasonic reflection caused by structural imperfections in the laminates. Therefore, it was found that interface C-scan images show the fiber orientation information by using two-dimensional fast Fourier transform (2-D FFT).

Optimum Quality Control of Seismic Data of Kunsan Basin in Offshore Korea (국내대륙붕 군산분지에 대한 탄성파 전산처리의 최적 매개 변수 결정)

  • Kim, Kun-Deuk
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.3
    • /
    • pp.161-169
    • /
    • 1998
  • The Kunsan basin is a pull-apart basin which was formed during Tertiary. The pre-Tertiary section consists of various rock types, such as meta-sediments, igneous rocks, carbonates, clastics, and volcanics. Tertiary sections are the main targets for the petroleum exploration. In order to determine the optimum processing parameters of the basin, about 12 kinds of test processings were performed. The first main steps for the quality control is to determine the noisy or bad traces by examining the near trace section and shot gathers. The true amplitude recovery was applied to account for the amplitude losses due to spherical divergence and inelastic attenuation. Source designature and predictive deconvolution test were conducted to determine the optimum wavelet parameters and to remove the multiples. Velocity analysis was performed at 1km intervals. The optimum mute function was picked by locating the range of offsets which gives the best stacking response for any particular reflections. Post-stack deconvolution was tested to see if the quality of stacked data improved. The stacked data was migrated using a finite difference algorithm. The migration velocity was obtained from the stacking velocities using the time varying percentages. The AGC sections were provided for the structural interpretation. The RAP sections were used for DHI analysis and for the detection of volcanics.

  • PDF

Auto-dump Design of Postharvest Bulk Handling Machinery System for Onions

  • Park, Jongmin;Choi, Wonsik;Kim, Ghiseok;Kim, Jongsoon
    • Journal of Biosystems Engineering
    • /
    • v.43 no.4
    • /
    • pp.379-385
    • /
    • 2018
  • Purpose: Postharvest handling of onions (harvesting, cleaning, grading, cooling, storing, and transport) should be performed continually to reduce costs and improve quality. The purpose of this study is to a) determine the design parameters and operating conditions of anion auto-dumping that constitutes a key component of the postharvest bulk handling machinery system, and b) to perform a performance test with the auto-dump prototype system. Methods: Kinematic analyses and computer simulations of the auto-dump mechanism were applied to analyze the operating conditions and design parameters. Results: The optimum working condition for the auto-dump was determined from kinetic analyses. In addition, the interaction between the velocity of the hydraulic cylinder and the angular velocity of the auto-dump were analyzed in order to control the bulk handling machinery system. The acting forces and optimum operating conditions of the hydraulic cylinder were determined by analyzing the forces related to the mass of inertia of the auto-dump assembly during rotation. The method of controlling the feeding rate of onions in terms of the uniformity of the stacking pattern and the control of the entire system was better than the two-stage method of controlling the rotational speed of the auto-dump. Based on the performance test with the prototype for the auto-dump, the stacking pattern and rigidity of the system were analyzed. Conclusions: These results would be of great importance in the postharvest bulk handling machinery system for onions.

Structural Safety Test and Analysis of Type IP-2 Transport Packages with Bolted Lid Type and Thick Steel Plate for Radioactive Waste Drums in a NPP (원자력발전소의 방사성폐기물 드럼 운반을 위한 볼트체결방식의 두꺼운 철판을 이용한 IP-2형 운반용기의 구조 안전성 해석 및 시험)

  • Lee, Sang-Jin;Kim, Dong-hak;Lee, Kyung-Ho;Kim, Jeong-Mook;Seo, Ki-Seog
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.199-212
    • /
    • 2007
  • If a type IP-2 transport package were to be subjected to a free drop test and a penetration test under the normal conditions of transport, it should prevent a loss or dispersal of the radioactive contents and a more than 20% increase in the maximum radiation level at any external surface of the package. In this paper, we suggested the analytic method to evaluate the structural safety of a type IP-2 transport package using a thick steel plate for a structure part and a bolt for tying a bolt. Using an analysis a loss or dispersal of the radioactive contents and a loss of shielding integrity were confirmed for two kinds of type IP-2 transport packages to transport radioactive waste drums from a waste facility to a temporary storage site in a nuclear power plant. Under the free drop condition the maximum average stress at the bolts and the maximum opening displacement of a lid were compared with the tensile stress of a bolt and the steps in a lid, which were made to avoid a streaming radiation in the shielding path, to evaluate a loss or dispersal of radioactive waste contents. Also a loss of shielding integrity was evaluated using the maximum decrease in a shielding thickness. To verify the impact dynamic analysis for free drop test condition and evaluate experimentally the safety of two kinds of type IP-2 transport packages, free drop tests were conducted with various drop directions. For the tests we examined the failure of bolts and the deformation of flange to evaluate a loss or dispersal of radioactive material and measured the shielding thickness using a ultrasonic thickness gauge to assess a loss of shielding integrity. The strains and accelerations acquired from tests were compared with those by analyses to verify the impact dynamic analysis. The analytic results were larger than the those of test so that the analysis showed the conservative results. Finally, we evaluated the safety of the type IP-2 transport package under the stacking test condition using a finite element analysis. Under the stacking test condition, the maximum Tresca stress of the shielding material was 1/3 of the yielding stress. Two kinds of a type IP-2 transport package were safe for the free drop test condition and the stacking test condition.

  • PDF

Low Velocity Impact Property of CF/Epoxy Laminate according to Interleaved Structure of Amorphous Halloysite Nanotubes (비정질 할로이사이트 나노입자의 교차적층 구조에 따른 탄소섬유/에폭시 라미네이트의 저속 충격 특성)

  • Ye-Rim Park;Sanjay Kumar;Yun-Hae Kim
    • Composites Research
    • /
    • v.36 no.4
    • /
    • pp.270-274
    • /
    • 2023
  • The stacking configuration of fiber-reinforced polymer (FRP) composites, achieved via the filament winding process, exhibits distinct variations compared to conventional FRP composite stacking arrangements. Consequently, it becomes challenging to ascertain the influence of mechanical properties based on the typical stacking structures. Thus, it becomes imperative to enhance the mechanical behavior and optimize the interleaved structures to improve overall performance. Therefore, this study aims to investigate the impact of incorporating amorphous halloysite nanotubes (A-HNTs) within different layers of five unique layer arrangements on the low-velocity impact properties of interleaved carbon fiber-reinforced polymer (CFRP) structures. The low-velocity impact characteristics of the laminate were validated using a drop weight impact test, wherein the resulting impact damage modes and extent of damage were compared and evaluated under microscopic analysis. Each interleaved structure laminate according to whether nanoparticles are added was compared at impact energies of 10 J and 15 J. In the case of 10 J, the absorption energy showed a similar tendency in each structure. However, at 15 J, the absorption energy varies from structure to structure. Among them, a structure in which nanoparticles are not added exhibits the highest absorption energy. Additionally, various impact fracture modes were observed in each structure through optical microscopy.

Fracture Analysis of Plasma Spray Coating by Classification of AE Signals (AE파형분류에 의한 용사코팅재의 파손해석)

  • Kim, G.S.;Park, K.S.;Hong, Y.U.
    • Journal of Power System Engineering
    • /
    • v.6 no.3
    • /
    • pp.24-30
    • /
    • 2002
  • The deformation and fracture behaviors of both Al2O3 and Ni 4.5wt.%Al plasma thermal spray coating were investigated by an acoustic emission method. Plasma thermal spray coating is formed by a process in which melted particles flying with high speed towards substrate, then crash and spread on the substrate surface cooled and solidified in a very short time, stacking of the particles makes coating. A tensile test is conducted on notch specimens in a stress range below the elastic limit of substrate. A bendind test is done on smooth specimens. The waveforms of AE generated from the both test coating specimens can be classified by FFT analysis into two types which low frequency(type I) and high frequency(type II). The type I waveform is considered to corresponds exfoliation of coating layers and type II waveform corresponds the plastic deformation of notch tip. The fracture of the coating layers can estimate by AE event and amplitude, because AE features increase when the deformation generates.

  • PDF

gate stack구조를 이용한 LTPS TFT의 전기적 특성 분석

  • Jeon, Byeong-Gi;Jo, Jae-Hyeon;Lee, Jun-Sin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.59-59
    • /
    • 2009
  • The efficiency of CMOS technology has been developed in uniform rate. However, there was a limitation of reducing the thickness of Gate-oxide since the thickness of Gate Dielectric is also reduced so an amount of leakage current is grow. In order to solve this problem, the semiconductor device which has a dual gate is used widely. This paper presents a method and a necessity for making the Gate Stack of TFT. Before Using test devices to measure values, stacking $SiN_x$ on a wafer test was conducted.

  • PDF

Development of High Voltage and High Energy Density Capacitor for Pulsed Power Application (펄스파워용 고전압 고에너지밀도 커패시터 개발)

  • 이병윤;정진교;이우영;박경엽;이수휘;김영광
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.5
    • /
    • pp.203-210
    • /
    • 2003
  • This paper describes high voltage and high energy density capacitor developed for pulsed power applications. The rated voltage of the developed capacitor is DC 22 [kV], the capacitance is 206 [$\mu$F] and the energy density is about 0.7 [kJ/kg]. Polypropylene film and kraft paper were used as the dielectrics. The ratio of the thickness of each dielectric material which consists of the composite dielectric structure, stacking factor and the termination method were determined by the charging and discharging tests on model capacitors. In terms of energy density, the developed capacitor has higher energy density compared with the products of foreign leading companies. In addition, it has been proved that the life expectancy can be more over 2000 shots through the charging and discharging test. The voltage reversal factor was 20%. This capacitor can be used as numerous discharge applications such as military, medical, industrial fields.