• Title/Summary/Keyword: stable operation

Search Result 1,973, Processing Time 0.036 seconds

In-Hospital Outcomes of Acute Renal Failure Requiring Continuous Renal Replacement Therapy in Patients with On-pump CABG (심폐기 가동하 관상동맥우회술 후 발생한 급성신부전 환자들에 있어 지속적 신대체요법의 병원 내 결과)

  • Kim, Young-Du;Park, Kuhn;Kang, Chul-Ung;Yoon, Jeong-Seob;Moon, Seok-Whan;Wang, Young-Pil;Jo, Kuhn-Hyun
    • Journal of Chest Surgery
    • /
    • v.40 no.1 s.270
    • /
    • pp.32-36
    • /
    • 2007
  • Background: Although acute renal failure (ARF) after coronary artery bypass graft (CABG) is relatively rare, but devastating complication with high mortality. Our study aims to evaluate the effectiveness of early application of CRRT in patients with ARF which developed after on-pump CABG. Material and Method: Two hundred and eighty seven patients underwent isolated on-pump CABG between May 2002 and Feb. 2006 at our institution, of whom 15 (5.2%) needed CRRT (11 patients for postoperatively developed ARF and the remaining 4 patients with preexisting dialysis-dependent chronic renal failure (CRF) for postoperative hemodynamic and metabolic control). Criteria for early application of CRRT were as follows; decreased urine output less than 0.5cc/h/kg for 2 consecutive hours and elevated serum creatinine level greater than 2.0 mg/dL. Result: The incidence of ARF requiring CRRT after on-pump CABG was 3.9% (11/283) and the overall hospital mortality of patient with CRRT was 33.3% (5/15). Of 5 deaths, 4 were patients with postoperatively developed ARF, and 1 was a patient with pre-existing dialysis-dependent CRF patient. The mean time between the operation and the initiation of CRRT was $25.8{\pm}5.8$ hours and the mean duration of CRRT was $62.1{\pm}41.2$ hours. Of the 7 survivors who were not on dialysis-dependent preoperatively, 6 patients fully recovered renal function during hospital stay and 1 patient required permanent renal supportive treatment after discharge from hospital. Conclusion: Early application of CRRT could maintain stable postoperative hemodynamic status and make outcomes better than those of previous reports in patients with ARF which developed after on-pump CABG.

Effects of Fractionated Stereotactic Radiotherapy for Primary Hepatocellular Carcinoma (원발성 간암의 분할 정위방사선치료 효과)

  • Choi Byeong Ock;Kang Ki Mun;Jang Hong Seok;Lee Snag-wook;Kang Young Nam;Chai Gyu Young;Choi Ihl Bhong
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.92-97
    • /
    • 2005
  • Purpose : Reports on the outcome of curative radiotherapy for the primary hepatocellular carcinoma (HCC) are rarely encountered in the literature. in this study, we report our experience of a clinical trial where fractionated stereotactic radiotherapy (SRT) was used in treating a primary HCC. Materials and Methods : A retrospective analysis was peformed on 20 patients who had been histologically diagnosed as HCC and treated by fractionated SRT. The long diameter of tumor measured by CT was $2\~6.5$ cm (average: 3.8 cm). A single dose of radiation used in fractionated SRT was S or 10 Gy: each dose was prescribed based on the planning target volume and normalized to $85\~99\%$ isocenter dose. Patients were treated $3\~5$ times per week for 2 weeks, with each receiving a total dose of 50 Gy (the median dose: 50 Gy). The follow up period was $\~55$ months (the median follow up period: 23 months). Results : The response rate was $50\%$ (12 patients), with 4 patients showing complete response ($20%$), 8 patients showing partial response ($40\%$), and 8 patients showing stable disease ($40\%$). The 1-year and 2-year survival rates were $70.0\%$ and $43.1\%$, respectively, and the median survival time was 20 months. The 1-year and 2-year disease free survival rates were $65\%$ and $32.5\%$, respectively, and the median disease-free survival rate was 19 months. Some acute complications of the treatment were noted as follows: dyspepsia in 12 patients ($60\%$), nausea/emesis in 8 patients ($40\%$), and transient liver function impairment in 6 patients ($30\%$). However, there was no treatment related death. Conclusion : The study indicates that fractionated SRT is a relatively safe and effective method for treating primary HCC. Thus, fractionated SRT may be suggested as a local treatment for HCC of small lesion and containing a single lesion, when the patients are inoperable or operation is refused by the patients. We thought that fractionated SRT is a challenging treatment modality for the HCC.

Laboratory Tests for Trichloroethylene (TCE) and Toluene Remediation in Soil Using Soil Vapor Extraction (토양증기추출(Soil Vapor Extraction)을 이용한 토양 내 Trichloroethylene (TCE)과 Toluene정화 실험)

  • 이민희;강현민
    • Economic and Environmental Geology
    • /
    • v.35 no.3
    • /
    • pp.221-227
    • /
    • 2002
  • Column experiments were performed to evaluate the removal efficiency of soil vapor extraction (SVE) iota TCE (trichloroethylene) and toluene in soil. Homogeneous Ottawa sands and real soils collected from contaminated area were used to investigate the effect of soil properties and SVE operation conditions on the removal efficiency. In column teats with two different sizes of Ottawa sand, the maximum effluent TCE concentration in a coarse sand column was 442 mg/L and 337 mg/L in a fine sand column. However, after 20 liter gas flushing, the effluent concentrations were very similar and more than 90% of initial TCE mass were removed from the column. For two real contaminated soil columns, the maximum effluent concentration decreased 50% compared with that in the homogeneous Ottawa coarse sand column, but 99% of initial TCE mass were extracted from the column within 40 liter air flushing, suggesting that SVE is very available to remove volatile NAPLs in the contaminated soil. To investigate the effect of contaminant existing time on the removal efficiency, an Ottawa sand column was left stable for one week after TCE was injected and the gas extraction was applied into the column. Its effluent concentration trend was very similar to those for other Ottawa sand columns except that the residual TCE after the air flushing showed relatively high. Column tests with different water contents were performed and results showed high removal efficiency even in a high water content sand column. Toluene as one of BTEX compounds was used in an Ottawa sand column and a real soil column. Removal trends were similar to those in TCE contaminated columns and more than 98% of initial toluene mass were removed with SVE in both column.

Development of Automatic Loading Equipment of Seedling Tray for Automatic Process of Raising Seedlings in Plant Factory (식물공장 육묘공정 자동화를 위한 육묘트레이 자동적재장치 개발)

  • Park, Sang-Min;Min, Young-Bong;Lee, Gong-In;Kim, Dong-Ouk;Kang, Dong-Hyun;Moon, Sung-Dong
    • Journal of agriculture & life science
    • /
    • v.45 no.5
    • /
    • pp.105-113
    • /
    • 2011
  • This study was carried out to develop an automatic loading equipment that can load seedling trays on loading position of the seedling bed driving on enclosed-type rail installed for interconnecting each process of raising seedlings in plant factory. The experiment of transferring the seedling tray by monorail pusher was carried out to figure out the required transfer force and problems during push type device of transporting the plastic seedling trays, that has completed its sowing process, which are installed onto the board of different materials. From the results of this experiment, the loading equipment which can exactly load three of the seedling trays orderly on the loading position of the seedling bed was designed and made. When three sowed trays on every board are transferred by pusher with the speed is at 30 cm/s, the maximum peak transfer force with maximum overshooting at initial transient state and the maximum transfer force at stead state are were respectively 32.8 N, 29.4 N on rubber board, 29.7 N, 22.5 N on a wooden board, 26.9 N, 19.6 N on a acrylic board, and 27.6 N, 19.1 N on an iron board. Changes in the transfer force occurred its maximum at the moment when the pusher collided with the tray, after the collision gradually decreased until it became stable. When two or three trays placed it in order of widthwise are transferred, it is occurred the overlapping of the tray's external bracket. The developed automatic loading equipment with PLC controller did not make any operation error through 100 times of tests, its maximum seedling tray loading speed was 2 sec/tray and its maximum error of transferred location of the tray was 0.5 cm.

Clinical Evaluation of Guided Bone Regeneration Using 3D-titanium Membrane and Advanced Platelet-Rich Fibrin on the Maxillary Anterior Area (상악 전치부 3D-티타늄 차폐막과 혈소판농축섬유소를 적용한 골유도재생술의 임상적 평가)

  • Lee, Na-Yeon;Goh, Mi-Seon;Jung, Yang-Hun;Lee, Jung-Jin;Seo, Jae-Min;Yun, Jeong-Ho
    • Implantology
    • /
    • v.22 no.4
    • /
    • pp.242-254
    • /
    • 2018
  • The aim of the current study was to evaluate the results of horizontal guided bone regeneration (GBR) with xenograf t (deproteinized bovine bone mineral, DBBM), allograf t (irradiated allogenic cancellous bone and marrow), titanium membrane, resorbable collagen membrane, and advanced platelet-rich fibrin (A-PRF) in the anterior maxilla. The titanium membrane was used in this study has a three-dimensional (3D) shape that can cover ridge defects. Case 1. A 32-year-old female patient presented with discomfort due to mobility and pus discharge on tooth #11. Three months after extracting tooth #11, diagnostic software (R2 GATE diagnostic software, Megagen, Daegu, Korea) was used to establish the treatment plan for implant placement. At the first stage of implant surgery, GBR for horizontal augmentation was performed with DBBM ($Bio-Oss^{(R)}$, Geistlich, Wolhusen, Switzerland), irradiated allogenic cancellous bone and marrow (ICB $cancellous^{(R)}$, Rocky Mountain Tissue Bank, Denver, USA), 3D-titanium membrane ($i-Gen^{(R)}$, Megagen, Daegu, Korea), resorbable collagen membrane (Collagen $membrane^{(R)}$, Genoss, Suwon, Korea), and A-PRF because there was approximately 4 mm labial dehiscence after implant placement. Five months after placing the implant, the second stage of implant surgery was performed, and healing abutment was connected after removal of the 3D-titanium membrane. Five months after the second stage of implant surgery was done, the final prosthesis was then delivered. Case 2. A 35-year-old female patient presented with discomfort due to pain and mobility of implant #21. Removal of implant #21 fixture was planned simultaneously with placement of the new implant fixture. At the first stage of implant surgery, GBR for horizontal augmentation was performed with DBBM ($Bio-Oss^{(R)}$), irradiated allogenic cancellous bone and marrow (ICB $cancellous^{(R)}$), 3D-titanium membrane ($i-Gen^{(R)}$), resorbable collagen membrane (Ossix $plus^{(R)}$, Datum, Telrad, Israel), and A-PRF because there was approximately 7 mm labial dehiscence after implant placement. At the second stage of implant surgery six months after implant placement, healing abutment was connected after removing the 3D-titanium membrane. Nine months after the second stage of implant surgery was done, the final prosthesis was then delivered. In these two clinical cases, wound healing of the operation sites was uneventful. All implants were clinically stable without inflammation or additional bone loss, and there was no discomfort to the patient. With the non-resorbable titanium membrane, the ability of bone formation in the space was stably maintained in three dimensions, and A-PRF might influence soft tissue healing. This limited study suggests that aesthetic results can be achieved with GBR using 3D-titanium membrane and A-PRF in the anterior maxilla. However, long-term follow-up evaluation should be performed.

Salvage with Reverse Total Shoulder Arthroplasty after the Failure of Proximal Humeral Tumor Treatment (근위 상완골 종양 치료 실패 후 역 견관절 전치환물을 이용한 구제술)

  • Jeon, Dae-Geun;Cho, Wan Hyeong;Kim, Bum Suk;Park, Hwanseong
    • Journal of the Korean Orthopaedic Association
    • /
    • v.53 no.6
    • /
    • pp.505-512
    • /
    • 2018
  • Purpose: Many reconstruction methods have been attempted after an en-bloc resection of the proximal humerus. In particular, the introduction of reverse shoulder arthroplasty (RSA) has made a breakthrough in the functional recovery of the shoulder. Nevertheless, RSA has limitations when the humeral bone stock loss is significant. In addition, it is unclear if RSA is effective in patients showing failure with non-operative treatment of a proximal humeral tumor. Materials and Methods: A reconstruction was performed using an overlapping allograft-RSA composite for 11 patients with a failed proximal humeral construct. Delayed RSA was performed on 6 patients with failed non-operative treatment. The pre- and postoperative Musculoskeletal Tumor Society (MSTS) score and the complications were addressed. Results: Overlapping allograft-RSA composite afforded a stable construct in 11 failed proximal humeral reconstructions and the patient's chief complaints were resolved. The mean time to the union of overlapped allograft-host junction was 5.5 months. Average preoperative MSTS score of 20.3 point increased to 25.7 point, postoperatively. Four of the six patients who had RSA within 4 years from the index operation showed arm elevation of more than $90^{\circ}$ whereas the remaining 5 patients showed some disability. The complications include one case each of dislocation and aseptic infection, which were resolved by changing the polyethylene liner and scar revision, respectively. None of the 6 patients who underwent delayed RSA after the failure of non-operative treatment showed arm elevation more than $90^{\circ}$. Conclusion: An overlapping allograft-RSA composite is a simple and reliable reconstructive modality in patients with massive bone loss. In patients with metastatic cancer necessitating a surgical resection at presentation, early conversion to RSA is recommended to secure functional recovery.

A Study for establishment of soil moisture station in mountain terrain (1): the representative analysis of soil moisture for construction of Cosmic-ray verification system (산악 지형에서의 토양수분 관측소 구축을 위한 연구(1): Cosmic-ray 검증시스템 구축을 위한 토양수분량 대표성 분석 연구)

  • Kim, Kiyoung;Jung, Sungwon;Lee, Yeongil
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.1
    • /
    • pp.51-60
    • /
    • 2019
  • The major purpose of this study is to construct an in-situ soil moisture verification network employing Frequency Domain Reflectometry (FDR) sensors for Cosmic-ray soil moisture observation system operation as well as long-term field-scale soil moisture monitoring. The test bed of Cosmic-ray and FDR verification network system was established at the Sulma Catchment, in connection with the existing instrumentations for integrated data provision of various hydrologic variables. This test bed includes one Cosmic-ray Neutron Probe (CRNP) and ten FDR stations with four different measurement depths (10 cm, 20 cm, 30 cm, and 40 cm) at each station, and has been operating since July 2018. Furthermore, to assess the reliability of the in-situ verification network, the volumetric water content data measured by FDR sensors were compared to those calculated through the core sampling method. The evaluation results of FDR sensors- measured soil moisture against sampling method during the study period indicated a reasonable agreement, with average values of $bias=-0.03m^3/m^3$ and RMSE $0.03m^3/m^3$, revealing that this FDR network is adequate to provide long-term reliable field-scale soil moisture monitoring at Sulmacheon basin. In addition, soil moisture time series observed at all FDR stations during the study period generally respond well to the rainfall events; and at some locations, the characteristics of rainfall water intercepted by canopy were also identified. The Temporal Stability Analysis (TSA) was performed for all FDR stations located within the CRNP footprint at each measurement depth to determine the representative locations for field-average soil moisture at different soil profiles of the verification network. The TSA results showed that superior performances were obtained at FDR 5 for 10 cm depth, FDR 8 for 20 cm depth, FDR2 for 30 cm depth, and FDR1 for 40 cm depth, respectively; demonstrating that those aforementioned stations can be regarded as temporal stable locations to represent field mean soil moisture measurements at their corresponding measurement depths. Although the limit on study duration has been presented, the analysis results of this study can provide useful knowledge on soil moisture variability and stability at the test bed, as well as supporting the utilization of the Cosmic-ray observation system for long-term field-scale soil moisture monitoring.

Investigation on Diesel Injection Characteristics of Natural Gas-Diesel Dual Fuel Engine for Stable Combustion and Efficiency Improvement Under 50% Load Condition (천연가스-디젤 혼소 엔진의 50% 부하 조건에서 제동효율 및 연소안정성 개선을 위한 디젤 분무 특성 평가)

  • Oh, Sechul;Oh, Junho;Jang, Hyungjun;Lee, Jeongwoo;Lee, Seokhwan;Lee, Sunyoup;Kim, Changgi
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.3
    • /
    • pp.45-53
    • /
    • 2022
  • In order to improve the emission of diesel engines, natural gas-diesel dual fuel combustion compression ignition engines are in the spotlight. In particular, a reactivity controlled compression ignition (RCCI) combustion strategy is investigated comprehensively due to its possibility to improve both efficiency and emissions. With advanced diesel direct injection timing earlier than TDC, it achieves spontaneous reaction with overall lean mixture from a homogeneous mixture in the entire cylinder area, reducing nitrogen oxides (NOx) and particulate matter (PM) and improving braking heat efficiency at the same time. However, there is a disadvantage in that the amount of incomplete combustion increases in a low load region with a relatively small amount of fuel-air. To solve this, sensitive control according to the diesel injection timing and fuel ratio is required. In this study, experiments were conducted to improve efficiency and exhaust emissions of the natural gas-diesel dual fuel engine at low load, and evaluate combustion stability according to the diesel injection timing at the operation point for power generation. A 6 L-class commercial diesel engine was used for the experiment which was conducted under a 50% load range (~50 kW) at 1,800 rpm. Two injectors with different spray patterns were applied to the experiment, and the fraction of natural gas and diesel injection timing were selected as main parameters. Based on the experimental results, it was confirmed that the brake thermal efficiency increased by up to 1.3%p in the modified injector with the narrow-angle injection added. In addition, the spray pattern of the modified injector was suitable for premixed combustion, increasing operable range in consideration of combustion instability, torque reduction, and emissions level under Tier-V level (0.4 g/kWh for NOx).

A Study on Evaluation Method for Structural Suitability of Constructed Wetlands in Dam Reservoirs as an Ecological Water Purification System (생태적 수질정화시설로서 댐 저수지 인공습지의 구조 적정성 평가방안)

  • Bahn, Gwon-Soo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.50 no.2
    • /
    • pp.23-40
    • /
    • 2022
  • Many constructed wetlands have been installed in dam reservoirs nationwide for ecological purification of watershed pollutants, but aging and reduced efficiency are becoming issues. To improve the management of constructed wetlands, an objective evaluation of structural suitability is required. This study evaluated 39 constructed wetlands of 15 dams. First, through fogus group interview(FGI), survey analysis, and analytic hierarchy process(AHP), eight evaluation items in the physical and vegetative aspects were selected and the evaluation criteria applied with weights were prepared. Second, as a result of the structural suitability evaluation, the average score of the overall constructed wetlands was 80.8, with 10 sites rated as 'good grade(91~100)', 22 sites rated as 'normal grade(71~90)' and 7 sites rated as 'poor grade(70 or less)'. The average score of physical structure evaluation was 52.6, with 14 sites rated as 'good', 21 sites as 'normal' and 4 sites as 'poor'. The suitability of location was good level in most constructed wetlands, but the water supply system, depth of water, ratio of length-to-width, and slope of flow channel were evaluated as 'normal' or less in constructed wetlands of 50% or more. Therefore, it was found that overall improvement was necessary for stable flow supply and flow improvement in the constructed wetland. The average score of vegetative structure evaluation was 28.2, and about 84% of them were identified as 'normal' or lower. As a result of analyzing the Spearman's correlation coefficient between the physical structure evaluation score and the vegetation structure evaluation score, there was a significant correlation(r = 0.728, p < 0.001), and it was found that each evaluation factor also influences each other. As a result of the case review of 6 constructed wetlands, the appropriateness of the evaluation results was confirmed, and it was found that the location, flow rate supply, and type of wetland had a great influence on the efficiency and operation of the wetland. Through this study, it will be possible to derive structural weaknesses of constructed wetlands in dam reservoirs as a nature-based solution, to prepare types and practical alternatives for improved management of each constructed wetland in the future, and to contribute to enhancing various environmental functions.

Characteristics of Coal Devolatilization and Spontaneous Combustion at Low Temperatures (저온영역에서 석탄의 탈휘발 및 자연발화 특성 연구)

  • Sung Min Yoon;Seok Hyeong Lee;Tae Hwi An;Myung Won Seo;Sang Won Lee;Dae Sung Kim;Tae-Young Mun;Sung Jin Park;Sang Jun Yoon;Ji Hong Moon;Jae Goo Lee;Jong Hoon Joo;Ho Won Ra
    • Clean Technology
    • /
    • v.29 no.4
    • /
    • pp.288-296
    • /
    • 2023
  • Coal is abundantly available compared to other energy sources and is used as a versatile energy resource worldwide. To address the environmental issues stemming from conventional coal utilization, efforts are underway to develop clean coal utilization technologies, with IGCC technology being a notable example. In IGCC plants, coal is subjected to a CMD process where both drying and pulverization are achieved by supplying hot air. However, if the temperature of the supplied hot air is excessively high, it can lead to devolatilization and spontaneous combustion, thereby compromising the stable operation of the CMD process. This study aimed to measure the devolatilization and spontaneous combustion temperatures of different types of bituminous coal, and to explore their correlations with the characteristics of the coals. Six coal types exhibited devolatilization between 350 and 400 ℃, while three coal types showed devolatilization at temperatures exceeding 400 ℃. Spontaneous combustion ℃curred in one coal type below 100 ℃, six coal types between 100 and 150 ℃, and two coal types above 150 ℃. The measured initiation temperatures were compared with the coal characteristics including the oxygen, moisture, Fe2O3, and CaO content, the H/C ratio, and the O/C ratio to establish correlations. Regression analysis was used to calculate the regression coefficients and determination coefficients for each ignition temperature. It was found that 52.44% of the FC/VM data significantly influenced the volatile matter ignition temperature, and 59.10% of the Fe2O3 data significantly affected the spontaneous combustionignition temperature.