• Title/Summary/Keyword: stability control measures

Search Result 88, Processing Time 0.033 seconds

A Study on the Static Deformation Monitoring of the Offshore Structures by GPS Survey (GPS 측량에 의한 해안구조물의 정적변위측정에 관한 연구)

  • 이창경;김창우
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.18 no.4
    • /
    • pp.369-378
    • /
    • 2000
  • The objective of this study is to measures deformation of the structures for stability checks by GPS survey. In this study, 2 points on south side dike of Keum River were measured by 4 sets of GPS(SR9500, Leica) every 4 months for a year, and 3-dimensional displacements of the points were acquired. In order to seek more reliable deformation measurement methods for the offshore structure by GPS, the accuracy of GPS survey with various control points configuration and checking system for detecting unrealistic measurements are also discussed.

  • PDF

Electromagnet Actuator Analysis of Magnetic Levitation System (자기부상시스템의 전자석 구동기 해석)

  • Kim, Chan-Jo;Cho, Kyeum-Rae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.11
    • /
    • pp.75-80
    • /
    • 2000
  • Recently, there are a great many research for magnetic levitation system. In case electromagnet is operated as the actuator of control system, first of all, we must analysis about an electromagnet. Important parameters of this system are inductance(L) and resistance(R) which are induced from the coil of electromagnet. And attractive force equation is also important. If the load of this system is large, phase delay is caused by self-inductance effect. Because this delay effect cause stability of whole magnetic evitation system to grow worse, a measures to diminish time constant must have been taken. And the linearized attractive force equation which is used at small range of the operating point is compensated to use at larger range, thus the experiment of magnetic levitation system will get a better result.

  • PDF

DC-Voltage Regulation for Solar-Variable Speed Hybrid System

  • Niyitegeka, Gedeon;Lee, Kyungkyu;Choi, Jaeho
    • Proceedings of the KIPE Conference
    • /
    • 2015.11a
    • /
    • pp.123-124
    • /
    • 2015
  • Recently interest on DC systems has been grown up extensively for more efficient connection with renewable energy. During the operation, there happens DC_link voltage variations. This paper focuses on the DC voltage stabilization applied in stand-alone DC microgrid to improve the system stability by keeping the voltage within limits. Batteries and a variable speed diesel generator cover the shortage of power after all available renewable energy is consumed. Load shedding or power generation reduction should automatically takes place if the maximum tolerable voltage variation is exceeded. PSIM based simulation results are presented to evaluate the performance of the proposed control measures.

  • PDF

Development of Relative Position Measuring Device for Moving Target in Local Area (국소영역에서 이동표적의 상대위치 측정 장치 개발)

  • Seo, Myoung Kook
    • Journal of Drive and Control
    • /
    • v.17 no.4
    • /
    • pp.8-14
    • /
    • 2020
  • Intelligent devices using ICT technology have been introduced in the field of construction machinery to improve productivity and stability. Among the intelligent devices, Machine Guidance is a device that provides real-time posture, location, and work range to drivers by installing various sensors, controllers, and satellite navigation systems on construction machines. Conversely, the efficiency of equipment that requires location information, such as machine guidance, will be greatly reduced in buildings, and tunnels in the GPS blind spots. Thus, the other high-precision positioning technologies are required in the GPS blind spot zone. In this study, we will develop a relative position measurement system that provides precise location information such as construction machinery and robots in a local area where the GPS reception is difficult. A relative position measurement system tracks a marker in the form of a sphere installed on a vehicle by using the image base tracking technology, and measures the distance and direction information to the marker to calculate a position.

Effect of favorite music therapy on anxiety and vital sign in patients undergoing gynecologic surgery using the general anesthesia (선호 음악요법이 전신마취 산부인과 수술 환자의 불안과 활력 징후에 미치는 효과)

  • Yang, Jung-Lim;Noh, Min-Young;Yang, Kyung-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1189-1199
    • /
    • 2015
  • This study examined the effects of favorite music therapy on the anxiety and vital signs at each point in gynecologic surgery using the general anesthesia. The research design was a non-equivalent control group non-synchronized design. The data were collected from May 1 to July 30, 2013 and the participants were 44 patients (experimental group, 21, control group, 23) received music therapy while waiting for anesthetic induction and PACU (Post Anesthesia Care Unit). Repeated measures ANOVA was performed to analyze the data by SPSS 18.0. Music therapy reduced the anxiety level at inducing the anesthetic time, and awakening time (p=.003; p=.011). The systolic blood pressure maintained stability at discharge from the PACU (p=.023), and pulse rate was stable at the awakening time (p=.016). This findings support the use of music as a nursing intervention to reduce anxiety and maintain the vital signs for gynecologic surgery patients under general anesthesia.

Development of LED Module Control-based PWM Current for Control of Heat-dissipation (방열특성 제어를 위한 PWM 전류제어 기반 LED 모듈 개발)

  • Lee, Seung-Hyun;Moon, Han Joo;Hue, Seong-bum;Choi, Seong-Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.6
    • /
    • pp.129-135
    • /
    • 2015
  • This paper shows significant methods that improve the lifespan of LED modules as well as efficiently using an aluminum heat-sink for LED module in high power. It proposes a method that raises stability and lifespan to protect LED modules and the power unit when the LED module has been used for a long hours at high temperatures. During the research, we applied a method of pulse-width modulation (PWM) in order to prevent the phenomenon that the entire power of a system is turned off and the lifespan is reduced when the LED nodule reacts to the high temperatures. To protect the LED module and SMPS based on high efficiency, a temperature sensor is attached underneath the circuit board and the sensor measures the temperature of circuit board when the LED module is powered on. The electrical power connected to SMPS is controlled by PWM when the temperature of the LED module reaches a particular temperature.

The Effects of Early Exercise Program on the Pain, Disability and Balance on Undergo Single-level Lumbar Discectomy (단일 요추간판 절제술 환자의 조기 운동프로그램이 통증, 장애, 균형에 미치는 영향)

  • Jeon, Jae-Guk;Kim, Myung-Jun
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.15 no.2
    • /
    • pp.80-87
    • /
    • 2009
  • Purpose: This study was to determine the effects of a early exercise program on the pain, disability and balance after single-level lumbar discectomy. Methods: Forty patients were randomized into experimental(N=20) and control(N=20) groups. Three days after surgery, patients in the experimental group undertook a 4-week exercise program. Assessments were performed in all patients during the week before surgery and at 4 weeks after. The assessment included measures of back and leg pain(VAS), Oswestry disability index(ODI), stability index(SI) and weight distribution index(WDI). Results: At 4 weeks, VAS, ODI, SI, WDI were significantly reduced in both groups(p<.01). Also the experimental group was significantly reduced back and leg pain(VAS), ODI and WDI were better than the control group(p<.05). Conclusion: It seems that early exercise program is more effective in patients who undergo single-level lumbar discectomy.

  • PDF

Supply models for stability of supply-demand in the Korean pork market

  • Chunghyeon, Kim;Hyungwoo, Lee ;Tongjoo, Suh
    • Korean Journal of Agricultural Science
    • /
    • v.49 no.3
    • /
    • pp.679-690
    • /
    • 2022
  • As the supply and demand of pork has become a significant concern in Korea, controlling it has become a critical challenge for the industry. However, compared to the demand for pork, which has relatively stable consumption, it is not easy to maintain a stable supply. As the preparation of measures for a supply-demand crisis response and supply control in the pig industry has emerged as an important task, it has become necessary to establish a stable supply model and create an appropriate manual. In this study, a pork supply prediction model is constructed using reported data from the pig traceability system. Based on the derived results, a method for determining the supply-demand crisis stage using a statistical approach was proposed. From the results of the analysis, working days, African swine fever, heat wave, and Covid-19 were shown to affect the number of pigs graded in the market. A test of the performance of the model showed that both in-sample error rate and out-sample error rate were between 0.3 - 7.6%, indicating a high level of predictive power. Applying the forecast, the distribution of the confidence interval of the predicted value was established, and the supply crisis stage was identified, evaluating supply-demand conditions.

Color stability of thermochromic pigment in maxillofacial silicone

  • Kantola, Rosita;Lassila, Lippo V.J.;Tolvanen, Mimmi;Valittu, Pekka K.
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.2
    • /
    • pp.75-83
    • /
    • 2013
  • PURPOSE. Maxillofacial silicone elastomer is usually colored intrinsically with color pigments to match skin colors. The purpose of this study was to investigate the color stability of a maxillofacial silicone elastomer, colored with a thermochromic, color changing pigment. MATERIALS AND METHODS. Disc-shaped maxillofacial silicone specimens were prepared and divided into 3 groups: a conventionally colored control group, one group additionally colored with 0.2 wt% thermochromic pigment, and one group with 0.6 wt% thermochromic pigment. Half of the surface of each specimen was covered with an aluminium foil. All of the specimens were exposed to UV radiation in 6 hour cycles over 46 days. In between the UV exposures, half of the specimens were stored in darkness, at room temperature, and the other half was stored in an incubator, at a humidity of 97% and a temperature of $+37^{\circ}C$. Color measurements were made with a spectrophotometer and registered according to the CIELAB $L^*a^*b^*$ color model system. The changes in $L^*$, $a^*$ and $b^*$ values during artificial aging were statistically analyzed by using paired samples t-test and repeated measures ANOVA. P-values <.05 were considered as statistically significant. RESULTS. The UV exposure resulted in visually noticeable and statistically significant color changes in the $L^*$, $a^*$ and $b^*$ values in both of the test groups containing thermochromic pigment. Storage in the incubator lead to statistically significant color changes in the $a^*$ and $b^*$ values of the specimens containing thermochromic pigment, compared to those stored at room temperature. CONCLUSION. The specimens containing thermochromic pigment were very sensitive to UV radiation, and the thermochromic pigment is not suitable, as such, to be used in maxillofacial prostheses.

The Test-Retest Reliability and Criterion-Related Validity of a Trunk Stability Robot When Measuring Static Sitting and Standing Symmetry in Stroke Patients (뇌졸중 환자들을 위한 체간 안정화 로봇의 정적인 앉기와 서기 대칭성 평가의 검사-재검사간 신뢰도와 기준 관련 타당도)

  • An, Seung-Heon;Kim, Dong-Hoon;Jang, Young-Min
    • PNF and Movement
    • /
    • v.16 no.3
    • /
    • pp.405-414
    • /
    • 2018
  • Purpose: The purpose of this study was to examine test-retest reliability and criterion-related validity of a trunk stability robot when measuring the weight-bearing symmetry static sitting and standing in stroke patients. Methods: For 27 stroke patients, weight-bearing symmetry was assessed twice, 7 days apart. The intraclass correlation coefficient (ICC2,1) and minimal detectable change (MDC) were used to examine the level of agreement between test and retest. The criterion-related validity of weight -bearing symmetry was demonstrated by Spearman correlation of modified Barthel index (MBI), the sit to stand test (STS), the timed up & go Test (TUG), and the function in sitting test (FIST). Results: the test-retest agreements were excellent for the weight-bearing symmetry of static sitting (ICC2,1: 0.90) and standing (ICC2,1: 0.89). It all showed that the acceptable MDC for the weight-bearing symmetry of static sitting and standing was 0.11 and 0.16, respectively (highest possible score<20 %), indicating that the measures had a small and acceptable degree of measurement error. The weight-bearing symmetry of static sitting was significantly correlated with the TUG(r=-0.45) and FIST(r=0.46)(p<0.05); the weight-bearing symmetry of static standing was also significantly correlated with MBI (r=0.65), TUG (r=-0.67), FIST (r=0.61)(p<0.01), and STS (r=-0.47)(p<0.05). Conclusion: The weight-bearing symmetry of static sitting and standing assessed by the trunk stability robot showed highly sufficient test-retest agreement and mild-to-moderate validity. It could also be useful for clinicians and researchers to evaluate balance performance and monitor functional change in stroke patients.