• Title/Summary/Keyword: squids

Search Result 87, Processing Time 0.03 seconds

Fabrication and statistical characterization of Nb SQUID sensors for multichannel SQUID system

  • Kim, B.K.;Yu, K.K.;Kim, J.M.;Kwon, H.;Lee, S.K.;Lee, Y.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.22 no.4
    • /
    • pp.62-66
    • /
    • 2020
  • We fabricated superconducting quantum interference devices (SQUIDs) based on Nb Josephson junctions, and characterized the key parameters of the SQUIDs. The SQUIDs are double relaxation oscillation SQUIDs (DROSs) having larger flux-to-voltage transfer coefficient than the standard DC-SQUIDs. SQUID sensors were fabricated by using Nb junction technology consisted of a DC magnetron sputtering and a conventional photolithography process. In multichannel SQUID systems for whole-head magnetoencephalography measurement with a helmet-type SQUID array, we need about 336 SQUID sensors for each system. In this paper, we fabricated a few hundred SQUID sensors, measured the critical current, flux modulation voltage and decided if each tested SQUID can be used for the multichannel systems. As the criterion for the acceptance of the sensors, we chose the critical current and amplitude of the modulation voltage to be 8 ㎂ and 80 ㎶, respectively. The average critical current of the SQUIDs was 10.58 ㎂. The typical flux noise of the SQUIDs with input coil shorted was 2 μΦ0/√Hz at white region.

Influence of luminous jig to catching of squid jigging in the Korean waters (오징어 채낚기 낚시의 야광이 어획에 미치는 영향)

  • RYU, Kyung-Jin;KIM, Hyung-Seok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.55 no.4
    • /
    • pp.303-309
    • /
    • 2019
  • This study identified the characteristics of squid jig in korea waters by investigating the effect of color and luminous performance of squid jig on the catch of squid and experimenting the result of jig according to green jig or white jig, and whether using luminous or not were tested in the sea to improve the jig of squid jigging. For this purpose, a total of 13 sea experiments were conducted using T/S No. 2 Galmaegi. As a result, 341 squids were caught. Among them, 221 squids were caught by green jig (64.8%), 64 squids were caught by white jig (18.8%), 41 squids were caught by green luminous jig (13.8%), and nine squids were caught by white luminous jig (2.6%). The green jig commonly used in jigging vessel was most effective, and luminous jig was less effective than that non-luminous jig. The squids caught were Japanese flying squid (Todarodes pacificus), swordtip squid (Loligo edulis) and spear squid (Loligo bleekeri), and no significant characteristics were found according to the color of jig and the presence of luminous.

Measurements of Correct Operation of a HTS 4-bit Shift Register Circuit (4-비트 고온초전도 Shift Register 회로의 동작 측정)

  • Park, Jong-Hyeog;Kim, Young-Hwan;Kang, Joon-Hee;Hahn, Taek-Sang;Kim, Chang-Hoon;Lee, Jong-Min;Choi, Sang-Sam
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.102-106
    • /
    • 1999
  • We have designed and fabricated a four-bit shift register circuit using YBCO bicrystal junctions and experimentally tested its operations by a computer-controlled digital measurement set-up. Laser ablated YBCO thin films with clean surface were used in this work. The circuit consists of the shift register and two read SQUIDs placed next to each sides of the shift register. The SQUIDs were inductively coupled to the nearby shift register stages. A probe equipped with high speed coax lines were used in this experiment. The major obstacle in testing the circuit was the interference between the read SQUIDs and we solved the problem by finding the correct operation points of the SQUIDs from the simultaneously measured modulation curves. Loaded Data("1" or "0") were successfully shifted from a stage to the next one by a controlled current pulse injected to the bias lines located between the stages and the data shifts were correctly monitored by the read SQUIDs

  • PDF

Stressed High Temperature Superconductor Films

  • Nikolaevich, Yugay Klimenty;Soh, Deawha
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05a
    • /
    • pp.80-84
    • /
    • 2004
  • The goal of the project is to study and describe a new stressed state of High Temperature Superconducting (High-Tc) YBCO Films, to create of SQUIDs on the bases of these Films with maximal sensitivity. The problems of the project are: 1. The experimental studying of the stressed films growing by laser ablation method. 2. The studying of stressed film properties. 3. The making of the dc-SQUIDs with maximal sensitivity on the bases of the stressed YBCO films.

  • PDF

Drying Characteristics of Squids According to Far Infrared and Heated Air Drying Conditions (원적외선과 열풍 건조조건에 따른 오징어의 건조특성)

  • Kang, Tae-Hwann;Hong, Hyun-Gi;Jeon, Hong-Young;Han, Chung-Su
    • Journal of Biosystems Engineering
    • /
    • v.36 no.2
    • /
    • pp.109-115
    • /
    • 2011
  • Drying characteristics of squids under two dry conditions were investigated using far infrared and heated air. Dry temperatures of 40, 50 and $60^{\circ}C$ with air speed of 0.6, 0.8 and 1.2 m/s were used for evaluating far infrared squid drying. Heated air squid drying at 40 and $50^{\circ}C$ with air speed of 0.8 m/s was used as a control treatment. The two drying were evaluated in terms of drying rate, color, TBA value, aerobic bacteria, cutting shear, penetration strength, and energy consumption. The drying rate of far infrared drying was relatively faster than that of heated air drying. The drying time of far infrared drying was reduced as the drying temperature increased. The color difference of far infrared dried squids was from 18.81 to 22.85, and heated air dried squid had the color different from 23.94 to 24.09. Far infrared dried squid had relatively smaller TBA values that indicate a level of rancidity. The aerobic bacteria of heated air dried squid increased from $970{\times}10^3$ to $40,000{\times}10^3$ CFU/g before and after drying, respectively. Far infrared dried squid had relatively smaller increase (from $970{\times}10^3$ to $40,000{\times}10^3$ CFU/g). The cutting shear and penetration strength for far infrared dried squids was relatively lower. In addition, far infrared squid drying consumed relatively less energy compared to heated air drying.

Fishing efficiency of high capacity (360W) LED fishing lamp for squid Todarodes pacificus (대용량 (360W급) LED 집어등의 오징어 어획성능)

  • An, Young-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.3
    • /
    • pp.326-333
    • /
    • 2014
  • This study was conducted to investigate the fishing efficiency of an improved LED fishing lamp for squids. A total of 31 fishing operations were carried out with six-crew commercial fishing vessel Haengbok-Ho (24 tons) on which 43.2kW LED was installed, along with 14 automatic jigging machines, from October 6 to November 16, 2012. The 19 fishing vessels with Haengbok-Ho were compared with a control subject was 24 tons or 29 tons. A total illuminating power of metal halide (MH) fishing lamps in the control fishing vessel was either 84kW or 120kW. The number of automatic jigging machines in the control vessels was 8-18 and the number of crews engaged for fishing operation was 3-13. Average fuel consumption of LED fishing vessels during fishing operation was 505.1l which led to an average fuel consumption of 42.7l per hour. LED fishing vessel and MH fishing vessel caught on an average 1,946 squids and 2,439 squids, respectively, during the study period. Crews (hand line and hand reel) caught about 2.2 times the automatic jigging machines for LED fishing vessel and about 2.1 times for MH fishing vessel. Meanwhile, catches by the fishing vessels with LED in the combined total number per one line of automatic jigging machine and per crew were 86.6% of that of the control fishing vessel with MH. Also, fishing vessels with LED per automatic jigging machine achieved 71.8% of catches of that with MH fishing lamp. The catches of squids per the fishing vessel with 1W LED fishing lamp were higher by more than 135.5% of that in the fishing vessel with MH, which showed a good fishing performance even with only the use of a LED fishing lamp.

Plerocercoids of Nybelinia surmenicola (Cestoda: Tentacularidae) in Squids, Todarodes pacificus, from East Sea, the Republic of Korea

  • Lee, Joon Yup;Kim, Ji Woon;Park, Gab Man
    • Parasites, Hosts and Diseases
    • /
    • v.54 no.2
    • /
    • pp.221-224
    • /
    • 2016
  • A visceral helminth of the squid, Todarodes pacificus, is reported from the East Sea, the Republic of Korea. Total 39 squid samples were purchased from a fish market in Jumunjin-eup, Gangneung-si (City) from August 2014 to July 2015 and were examined for helminth parasites with naked eyes and under a stereomicroscope after opening the abdominal cavity with a pair of scissors. Whitish larval worms were mainly found in the stomach and abdominal cavity of the squid. They were detected in 25 (64.1%) out of 39 squids examined, and the infection density was 7 larvae per infected squid. Spatula-shaped larvae were $8.2{\times}2.0mm$ in average size, round to slightly flattened anteriorly, with round hatching posteriorly, and had characteristic 4 tentacles with numerous hooklets in the scolex. The larvae were identified as the plerocercoid stage of Nybelinia surmenicola by their morphological features. This finding represents a new host record and the first report of N. surmenicola infection in T. pacificus squids from the east coast of Korea.

Changes of the Volatile Basic Nitrogen and Free Amino Acids according to the Fermentation of Low Salt Fermented Squid (저염 오징어 젓갈의 숙성에 따른 휘발성염기질소 및 유리 아미노산의 변화)

  • 오성천;조정순;남혜영
    • Korean journal of food and cookery science
    • /
    • v.16 no.2
    • /
    • pp.173-181
    • /
    • 2000
  • To understand the influences of NaCl concentration and fermentation temperature on the ripening process of low salt fermented squids, squid with 5%, 7% and 9% salt were fermented at 10$\^{C}$ and 20$\^{C}$. The result of the changes of volatile basic nitrogen and free amino acids during the fermentation of squids are as follows. As a result of the observations on the changes of physicochemical components during the fermentation process of the low-salted squids, all the pH, VBN and NH$_2$-N were increased and therefore the fermentation was promoted. Considering the changes of net components according to the fermentation, ATP (Adenosine triphosphate) and ADP (Adenosine diphosphate) lost and could not be detected among the nucleotides and their related compounds. Besides, AMP (Adenosine monophosphate) existed only in the initial stage and inosine, hypoxanthine were the main components of nucleotides and their related compounds. Nonvolatile organic acids are mainly lactic acid, acetic acid and also they occupied more than 80%. Seeing the composition of free amino acid, the major amino acids are proline, arginine, methionine, alanine and glutamic acid.

  • PDF

A Low-noise Double Relaxation Oscillation SQUID Magnetometer for Measuring Magnetoencephalogram

  • 강찬석;이용호;권혁찬;김진목;윤병운
    • Progress in Superconductivity
    • /
    • v.3 no.2
    • /
    • pp.151-158
    • /
    • 2002
  • We developed a useful SQUID magnetometer for biomagnetic applications, magnetoencepha-logram(MEG) and magnetocardiogram(MCG), etc. The SQUIDs are based on Double Relaxation Oscillation SQUID(DROS). DROS consists of two SQUIDs(signal SQUID and reference SQUID) in series, and a relaxation circuit of an inductor and a resistor. Specially we used single reference junction instead of the reference SQUID. The SQUIDs are based on hysteretic $Nb/AlO_{x}$Nb junctions, fabricated by using a simple four level process. Because DROS magnetometer has large flux-to-voltage transfer coefficient, we can use simple flux-locked loop electronics fur SQUID operation. When the DROS magnetometer was operated inside a magnetically shielded room, its average magnetic field noise was about 3 (equation omitted) at 100 Hz. This noise level is low enough to measure biomagnetic fields. In this paper, we describe noise characteristics of DROS magnetometer, depending on the operation condition . .

  • PDF

THIN FILM TECHNOLOGIES RELATED TO THE HIGH T$_{c}$ SUPERCONDUCTORS

  • Ri, Eui-Jae
    • Journal of Surface Science and Engineering
    • /
    • v.29 no.5
    • /
    • pp.415-423
    • /
    • 1996
  • Thin film technologies for fabricating SQUIDs involve etching and deposition procedures with the proper substrate materials and $YBa_2Cu_3O_{7-d}$ (YBCO) as the high $T_c$ superconductor. YBCO were prepared on various substrates of MgO, $SrTiO_3$, and $LaAlO_3$ by using off-axis magnetron sputtering methods and annealing in-situ. The parameters of film fabrication processes had been optimized to yield good quality films in terms of the critical temperature $T_c$ and the critical current density $J_c$. The optimized processes yielded $T_C$>90K along with $J_c$>$10_6A$$extrm{cm}^2$ at 77K and>$2\times10_7A/Cm^2$ at 5K. We fabricated step-edge type dc-SQUIDs and directly coupled magnetometers, producing step edges on MgO(100) substrates by etching with Ar-ion beam, depositing YBCO material on them, then patterning them by using ion-milling technique. Circuitizing washer-shape SQUIDs to possess a pair of step-edge junctions of 2-5$\mu$ line width with a high angle>$50^{\circ}C$ , we examined their I-V characteristics thoroughly and Shapiro steps clearly as we irradiate microwaves of 8-20 GHz frequency.

  • PDF