• 제목/요약/키워드: square wave voltage

검색결과 126건 처리시간 0.039초

수 분해형 오존발생장치의 전극선 비대현상과 자기회복 현상 (Build-up Phenomenon and Self-Cleaning Effect upon Wire Electrode Surface of an Electrolytic Ozone Generator in Tap Water)

  • 문재덕;김용
    • 대한전기학회논문지
    • /
    • 제40권6호
    • /
    • pp.626-629
    • /
    • 1991
  • The negative wire of an electrolytic ozone generator, proposed by authors, has been contaminated by attaching the impurity particulate in tap water, which is called BUILD-UP phenomenon. The higher applied voltage and the larger wire diameter have shown the higher build-up rate, which makes the current reducing largely and concurrently the ozone production smaller. It is found that the positive electrode of the ozone generator has a strong SELF-CLEANING effect by detaching the impurity particulate from its surface, which, however, is used us a novel means of solving the build-up problem. As a result, the build-up problem can be solved effectively by applying an alternate square wave pulse voltage to the electrodes so as to get the self-cleaning ability on the both electrodes during each of the half pulse duration time.

  • PDF

Implementation of Inverter Systems for DC Power Regeneration

  • Kim Kyung-Won;Yoon In-Sic;Seo Young-Min;Hong Soon-Chan;Yoon Duck-Yong
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.126-131
    • /
    • 2001
  • This paper deals with implementation of inverter systems for DC power regeneration, which can regenerate the excessive DC power from DC bus line to AC supply in substations for traction systems. From the viewpoint of both power capacity and switching losses, a three-phase square-wave inverter system is adopted. To control the regenerated power, the magnitude and phase of fundamental output voltages should be appropriately controlled in spite of the variation of input DC voltage. Inverters are operated with modified a-conduction mode to fix the potential of each arm. The overall system consists of the line-to-line voltage and line current sensors, an actual power calculator using d-q transformation method, a complex power controller with PI control scheme, a gating signal generator for modified $\alpha-conduction\;mode\;with\;\delta\;and\;\alpha$, a DPLL for frequency followup, and power circuit.

  • PDF

PWM 모드를 고려한 브러시리스 DC 전동기의 구동 특성 해석 (Driving Characteristic Analysis of Brushless DC Motor Considering PWM Mode)

  • 신현훈;이주
    • 조명전기설비학회논문지
    • /
    • 제19권4호
    • /
    • pp.98-107
    • /
    • 2005
  • 브러시리스 DC 전동기(BLDCM)는 일반적으로 $120[^{\circ}]$ 구형파 전압을 인가하여 구동하며 속도 제어를 위하여 2상 PWM 형태의 펄스로 이를 인가한다. 본 논문은 네 가지 PWM 방법을 이용한 BLDCM 제어 시스템을 소개하고, 2차원 시간차분 유한요소법을 이용하여 각 PWM 방식에 따른 전동기 성능 특성을 해석하고 비교한다. 또한 제안한 해석 기법의 타당성을 입증하기 위하여 BLDCM 시작기를 제작, 실험을 통하여 해석치와 실험치를 비교한다.

고압 대전류 펄스 전계를 이용한 저온 살균장치 시스템 연구 (The study of Low Temperature Pasteurization System using High Voltage High Current Pulse Electric Field)

  • 백주원;유동욱;조정구;정창용;;김학성;김흥근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.162-165
    • /
    • 1998
  • The non-thermal pasteurization of foods using High Voltage High Current Pulsed Electric Fields (HVHC-PEF) is a promising technology and a sound complement or replacement to traditional thermal pasteurization. The conventional thermal method also inactivates bacteria and other microorganisms harmful to humans, but degrades natural color, flavor, texture and nutrients. At this point, a nonthermal pasteurization technique, HVPEF is thought to be a new processing technique which is able to produce a good quality foods nutritional as well as sensuous. In this paper, the system for HVHC-PEF pasteurization is presented. It use square wave pulse instead of exponential ones. So, power rating of system is reduced considerably. Design considerations for 20kV 500A class equipment are analyzed and experimental results are discussed.

  • PDF

테이퍼형 마이크로스트립 선로에서 펄스의 왜곡 특성 분석 (Analysis of the Pulse Distortion on Tapered Microstrip Lines)

  • 김기래
    • 대한전자공학회논문지TC
    • /
    • 제37권8호
    • /
    • pp.45-51
    • /
    • 2000
  • 본 논문에서는 지수형, 삼각형 및 체비쉐브 테이퍼 전송선로에서 디지털 펄스가 전송될 때 분산과 반사에 의해 나타나는 펄스의 왜곡 특성을 시간영역에서 해석하여 그 전송특성을 비교하여 나타내었다. 그리고 테이퍼 선로에서 전압과 전류의 전달함수를 구하여 상승과 하강 시간을 갖는 비이상형 구형 펄스를 입력했을 때 왜곡 특성을 해석하고, 선로에서 나타나는 분산과 반사가 파형의 왜곡에 미치는 영향을 분석하였다. 주파수 분산에 의한 왜곡은 파형에 오버슈트와 기울림이 나타났고, 반사에 의한 왜곡은 꼬리 부분에 잔류 특성이 나타났다.

  • PDF

PDMS로 제작된 압전력 구동 방식의 마이크로 펌프의 특성 (Characterization of Piezoelectric-Actuated PDMS Micropump)

  • 김진호;나광호;김영호;김용상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1926-1928
    • /
    • 2003
  • The low-cost, simple structured micropump which is actuated by piezoelectricdiscs, is fabricated with polydimethylsiloxane (PDMS) and the performances of the micropump, such as pump rate and backward pressure, are characterized. The PDMS micropump with diffusers instead of passive check valves as a flow-rectifying element was fabricated. While the square wave driving voltage is applied to the piezoelectric disc of the actuator, the flow rate is measured by fluid displacement variation of the outlet tube. The flow rate of micropump increases with enhancing the applied voltage due to the increase of diaphragm deflection. The flow rate and the backward pressure of the micropump with diffusers are about $32.9{\mu}{\el}$/min and 173Pa respectively for the above mentioned deflection conditions.

  • PDF

릴레이를 이용한 차량용 배터리의 가변 충전기 (Variable Charger of Vehicle using Relay)

  • 송성근;정승태;강성구;이상훈
    • 조명전기설비학회논문지
    • /
    • 제26권9호
    • /
    • pp.47-56
    • /
    • 2012
  • This research is to develop satiable battery charger with a variety of capacity and voltage specifications of battery. For this, voltage or current were controlled through buck converter which is DC voltage that already received three-phase at primary side and passed bridge rectifier diode. And, it was comprised of full-bridge converter and HFTR for insulation and a square wave AC. The transformer primary side was comprised in series to divide certain charging current and the secondly side was comprised of 6 fixed transformers so that they can generate certain amount of power and various output voltage through relay parallel compound 6 DC Link outputs. To confirm such structure's verification and validity, simulation with PSIM was conducted, and validity of proposed variable charger system was verified through 3kW stack production.

주택용 단상 ESS-PCS의 LC 필터위치에 따른 상용변압기의 특성 (Characteristics of Utility Transformer on Household Single-Phase ESS-PCS According to LC Filter Location)

  • 김용중;김효성
    • 전력전자학회논문지
    • /
    • 제23권2호
    • /
    • pp.101-105
    • /
    • 2018
  • Shortage of electric power occurs frequently along with increased electric power demand. ESS is a precaution to solve this issue. Household ESS has a capacity of approximately 3 kW/7 kWh. Household ESS batteries are typically designed with nominal voltages between 40 and 50 V. To connect household ESS with a 220 V AC system, low battery voltages in power conditioning system (PCS) should be boosted. To boost low battery voltage and match it with AC grid voltage, the use of a transformer for a commercial frequency can be considered. To attenuate switching harmonics of the household single-phase ESS-PCS, LC filter can be installed in two positions: on the primary side or on the secondary side of a transformer. A method has been used generally in single-phase inverters for the ESS-PCS. In another method, however, the output efficiency of the ESS-PCS may be decreased. Parasitic components of the transformer can affect voltage losses, when the square wave with the switching frequency in the ESS-PCS is passed through the transformer windings. In this work, the characteristics of the transformer according to the position of an LC filter are investigated for household single-phase ESS-PCS.

방사전자파를 이용한 고분자애자의 오손량 분류기법 (Classification Technique of Kaolin Contaminants Degree for Polymer Insulator using Electromagnetic Wave)

  • 박재준
    • 한국전기전자재료학회논문지
    • /
    • 제19권2호
    • /
    • pp.162-168
    • /
    • 2006
  • Recently, diagnosis techniques have been investigated to detect a Partial Discharge associated with a dielectric material defect in a high voltage electrical apparatus, However, the properties of detection technique of Partial Discharge aren't completely understood because the physical process of Partial Discharge. Therefore, this paper analyzes the process on surface discharge of polymer insulator using wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time~frequency domain. As it is important to develop a non-contact method for detecting the kaolin contamination degree, this research analyzes the electromagnetic waves emitted from Partial Discharge using wavelet transform. This result experimentally shows the process of Partial Discharge as a two-dimensional distribution in the time-frequency domain. Feature extraction parameter namely, maximum and average of wavelet coefficients values, wavelet coefficients value at the point of $95\%$ in a histogram and number of maximum wavelet coefficient have used electromagnetic wave signals as input signals in the preprocessing process of neural networks in order to identify kaolin contamination rates. As result, root sum square error was produced by the test with a learning of neural networks obtained 0.00828.

원형 섹터가 추가된 DTV용 광대역 정사각형 루프 안테나 (Wideband Square Loop Antenna with Circular Sectors for Digital TV)

  • 여준호;이종익
    • 한국정보통신학회논문지
    • /
    • 제20권10호
    • /
    • pp.1845-1851
    • /
    • 2016
  • 본 논문에서는 DTV용 광대역 정사각형 루프 안테나에 대한 설계 방법에 대하여 연구하였다. 제안된 루프 안테나는 정사각형 루프 안테나와 중앙 급전점을 연결하는 원형 섹터가 결합된 형태이다. 안테나의 크기를 소형화하기 위해 원형 루프 대신에 사각형 루프를 사용하였다. DTV응용을 위해 75옴 포트 임피던스와 정합하도록 입력 반사계수와 이득 특성을 분석하였다. 원형 섹터 사이의 간격과 정사각형 루프의 길이 변화에 따른 입력 반사계수와 이득 특성을 분석하여 최적의 설계 변수를 도출하였다. 최적화된 안테나를 FR4 기판에 제작하고 특성을 실험한 결과, 전압 정재파비(VSWR; voltage standing wave) < 2인 대역이 468-1,268 MHz으로 DTV 대역(470-806 MHz)에서 동작하는 것을 확인하였다.