• 제목/요약/키워드: square partition

검색결과 49건 처리시간 0.02초

수평격판을 갖는 정사각형 밀폐공간내에서 자연대류 유동 및 열전달 (Natural Convective Flow and Heat Transfer in a Square Enclosure with a Horizontal Partition)

  • 정인기;김점수;송동주
    • 대한기계학회논문집
    • /
    • 제17권9호
    • /
    • pp.2304-2314
    • /
    • 1993
  • Natural convective flow and heat transfer in a two-dimensional square enclosure fitted with a horizontal partition are investigated numerically. The enclosure was composed of the lower hot and the upper cold horizontal walls and the adiabatic vertical walls, and a partition was situated perpendicularly at the one vertical insulated wall. The governing equations are solved by using the finite element method with Galerkin method. The computations were carried out with the variations of length, position and thermal conductivity of the partition, and Rayleigh number based on the temperature difference between two horizontal walls and the enclosure height with water(Pr=4.95). As the results, an oscillatory motion of natural convection is resulted in a sudden rise of overall heat transfer, but the increase of length of partition is significantly restrained the increase of Nusselt number. The maximum heat transfer was shown just before the transition of the direction of oscillating flow. An oscillatory motion of flow was perfectly shown the stability with the decrease of the length of partition and Rayleigh number. Also, the heat transfer was raised with the increase of the thermal conductivity in proportion to the increase of the length of partition. The stability and oscillation of flow are affected by the position of partition.

정사각형 밀폐공간내에서 수평격판에 의한 자연대류의 진동현상 (Oscillatory Motion of Natural Convection in a Square Enclosure with a Horizontal Partition)

  • 김점수;정인기;송동주
    • 설비공학논문집
    • /
    • 제5권4호
    • /
    • pp.285-294
    • /
    • 1993
  • An oscillatory motion of natural convection in a two-dimensional square enclosure fitted with a horizontal partition is investigated numerically. The enclosure was composed of the lower hot and the upper cold horizontal walls and the adiabatic vertical walls, and a partition was positioned perpendicularly at the mid-height of one vertical insulated wall. The governing equations are solved by using the finite element method with Galerkin method. The computations were carried out with the variations of the partition length and Rayleigh number based on the temperature difference between two horizontal walls and the enclosure height with water(Pr=4.95). As the results, an oscillatory motion of natural convection has perfectly shown the periodicity with the decrease of Rayleigh number, and the stability was reduced to a chaotic state with the increase of Rayleigh number. The period of oscillation gets shorten with the decrease of the partition length and the increase of Rayleigh number. The frequency of oscillation obtained by the variations of stream function is more similar to the experimental results than that of the average Nusselt number. The stability of oscillation grows worse with the increase of Rayleigh number. The transition Rayleigh number for the chaos is gradually decreased with the increase of the partition length.

  • PDF

제어판이 부착된 수평격판에 의해 분리되는 밀폐공간내의 난류 자연대류 열전달 특성 (Turbulent natural convective heat transfer charateristics in a square enclosure with control plates attached at the horifontal partition)

  • 김점수
    • 설비공학논문집
    • /
    • 제12권2호
    • /
    • pp.150-160
    • /
    • 2000
  • Turbulent natural convective flow and heat transfer in a square enclosure with horizontal partition are investigated numerically. The enclosure is composed of a lower hot and a upper cold horizontal walls and adiabatic vertical walls. Partitions carried with the upward, downward, and both control plates are attached perpendicularly to the one of the vertical insulated walls, respectively. The low Reynolds number $k-\varepsilon$ model is adopted to calculate the turbulent thermal convection. The governing equations are solved by using the finite element method with Galerkin method. The computations have been carried out by varying the length of partition, the position of control plates, and the Rayleigh number based on the temperature difference between two horizontal walls and the enclosure height for water(Pr=4.95). When the control plates are attached at the edge of partition, the stability of oscillating flow grows wrose with the increase of Rayleigh number and the partition length. The heat transfer rate has been reducer than that of no control plate due to the restraint of control plates with the increase of Rayleigh number.

  • PDF

격판이 존재하는 정사각형 밀폐공간내의 자연대류에 대한 PIV 계측 (PIV Measurement of Natural Convection in a Square Partitioned Enclosure)

  • 김광희;김유곤
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.708-713
    • /
    • 2001
  • The paper presented some results of a experimental study of natural convection in partitioned 2D square enclosure. The square enclosure consist of two adiabatic vertical walls and the upper cold and the lower hot walls. A partition is positioned perpendicularly at the center of left vertical insulated wall The PIV mesaurements were performed with the variations of the partition length and inclination of enclosure. The working fluid is water with a Prandtl number of 6.996 at $20^{\circ}C$ temperature. A captured images were calculated by using a Cross-Correlation(Multi-frame/Single-exposure) method.

  • PDF

격판이 존재하는 경사진 정사각형 밀폐공간 내의 자연대류유동에 관한 실험적 연구 (Experimental Study for Natural Convection Flow in an Inclined Partitioned Square Enclosure)

  • 김광희;김유곤
    • 대한기계학회논문집B
    • /
    • 제26권2호
    • /
    • pp.310-317
    • /
    • 2002
  • In the present study, an experimental study of natural convection in a partitioned 2D square enclosure has been carried out. The square enclosure consist of two adiabatic vertical walls and the upper cold and the lower hot walls. A partition is positioned perpendicularly at the center of the left vortical insulated wall. The PIV measurements were performed with the variations of Rayleigh number, partition length and inclination of the enclosure. The working fluid is water with Prandtl number of 6.996 at 20$\^{C}$. The captured images were analyzed by using a cross-correlation (two-frame/single-exposure) PIV method.

수평격판을 갖는 4각형 밀폐공간내에서 자연대류의 진동유동 (Oscillatory Motion of Natural Convective Flow in Partially Divided Square Enclosure)

  • 김점수;정인기;송동주
    • 대한기계학회논문집
    • /
    • 제16권10호
    • /
    • pp.1963-1970
    • /
    • 1992
  • 본 연구에서는 Fig.1에 나타낸 정 등의 모델을 사용하여 공간내의 자연대류 유동을 수치적으로 해석하고 실험결과와 비교하여 수평격판에 의해서 발생하는 진동유 동의 특성을 규명하고자 한다. 본 수치해석에서는 물(Pr=4.95)을 내부유체로 하여 Rayleigh수, 공간의 폭에 대한 격판길이(L/W)및 격판의 열전도율의 변화가 자연대류 진동유동에 미치는 영향을 밝히고, 밀폐공간의 경사에 의해 진동유동이 사라지는 각 도, 즉 천이 경사각도를 찾아 내고자 한다. 이러한 유동특성을 파악하기 위하여 본 연구에서는 지배방정식을 Galerkin method를 사용한 2차원 유한요소법(FEM)으로 수치 해석하였다.

초등학교 수학에서 분수 나눗셈의 알고리즘 정당화하기 (Justifying the Fraction Division Algorithm in Mathematics of the Elementary School)

  • 박중규;이광호;성창근
    • 한국수학교육학회지시리즈C:초등수학교육
    • /
    • 제22권2호
    • /
    • pp.113-127
    • /
    • 2019
  • 본 연구의 목적은 자연수 나눗셈의 정의를 확장하여 분수 나눗셈에 적용함으로써 초등학교 수학에서 분수 나눗셈의 알고리즘을 정당화하는데 있다. 먼저 초등학교 수학에서 분수 나눗셈을 도입할 때 고려해야 할 준거들을 도출하여 제시하였다. 이를 바탕으로 분수 나눗셈의 표준 알고리즘을 유도하는 기존의 방식들이 분수 나눗셈 도입 과정에 적절한지를 고찰하였다. 또한 분수 나눗셈을 정의하였으며, 단위원 분할 모델과 정사각형 분할 모델을 통하여 구체적 조작 활동을 함으로써 등분제와 포함제 상황의 분수 나눗셈에서 표준 알고리즘을 자연스럽게 정당화하였다.

수평격판으로 분리된 정사각형 밀폐공간내의 층류 자연대류 해석 (An investigation of laminar natural convection in a square partitioned enclosure)

  • 김점수;정인기
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.312-322
    • /
    • 1997
  • The natural convective flow in a two-dimensional square enclosure with horizontal partitions is investigated numerically. The enclosure was composed of the lower hot and the upper cold horizontal walls and the adiabatic vertical walls, and two identical partitions were positioned perpendicularly at the mid-height of the right and left walls, respectively. The governing equations are solved by using the finite element method with Galerkin method. Calculations are made for different partition lengths, partition conductivites, and Rayleigh numbers based on the temperature difference between two horizontal walls and the enclosure height with water(Pr=4.95). An oscillatory motion of the natural convective flow is affected significantly by the variation of the gap width and Rayleigh number. When the gap width is comparatively short, the heat transfer rate is raised with the increase of the thermal conductivity of partitions. However, for sufficiently large gap widths at higher Rayleigh numbers, the average Nusselt numbers of the conductive partitions are smaller than those of the adiabatic partitions.

  • PDF

Nonlinear Characteristics of Fuzzy Scatter Partition-Based Fuzzy Inference System

  • Park, Keon-Jun;Huang, Wei;Yu, C.;Kim, Yong K.
    • International journal of advanced smart convergence
    • /
    • 제2권1호
    • /
    • pp.12-17
    • /
    • 2013
  • This paper introduces the fuzzy scatter partition-based fuzzy inference system to construct the model for nonlinear process to analyze nonlinear characteristics. The fuzzy rules of fuzzy inference systems are generated by partitioning the input space in the scatter form using Fuzzy C-Means (FCM) clustering algorithm. The premise parameters of the rules are determined by membership matrix by means of FCM clustering algorithm. The consequence part of the rules is represented in the form of polynomial functions and the parameters of the consequence part are estimated by least square errors. The proposed model is evaluated with the performance using the data widely used in nonlinear process. Finally, this paper shows that the proposed model has the good result for high-dimension nonlinear process.

단순확장관 내부 파티션 위치에 따른 음향투과손실 계산식의 개발 (Development of a Formula for Acoustic Transmission Loss According to Partition Positions in a Simple Expansion Chamber)

  • 박정필;배경원;정의봉;안세진
    • 한국소음진동공학회논문집
    • /
    • 제25권2호
    • /
    • pp.116-123
    • /
    • 2015
  • This paper proposed a new formula for predicting acoustic power transmission loss of simple expansion chamber with two internal partitions. Seventeen cases of computational results were performed and the database was constructed for the TL according to the various positions of internal partitions. Using this database, firstly, the formula for the peak values of TL at certain frequencies was developed using the least square estimation. Secondly, the formula for the TL curve could be obtained automatically with the input data of the positions of two internal partitions. The formula of TL developed in this paper showed good agreement with computational results. This formula will be helpful for the positioning of internal partitions to improve TL at target frequencies.