• Title/Summary/Keyword: sport shoes

Search Result 114, Processing Time 0.025 seconds

A Study for impact absorption function of midsole in Cushioned Marathon Shoes (충격흡수용 마라톤화(Cushioned Shoes) 개발을 위한 중창·하지의 충격흡수기능 연구 -마라톤화 연구의 과거 & 현재를 중심으로-)

  • Park, Seung-Bum;Seo, Kuk-Woong;Kim, Yong-Jae
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.1
    • /
    • pp.89-114
    • /
    • 2002
  • The purpose of this study was to analyze impact absorption function of midsole in cushioned marathon shoes. The foot is made up of a complex interaction of bones, ligaments, and muscles. These structures help the foot alternate between being a mobile, flexible adaptor and a stable rigid lever. The foot is broken down into two functional parts, the forefoot and the rearfoot. Cushioned marathon shoes for high arches have generous cushioning for efficient and high-mileage runners. Cushioned marathon shoes are made for feet that have high arches or no excessive motion and don't roll inward or roll outward. This condition is known as underpronation. Especially, Cushioned marathon shoes are designed to reduce shock and generally have the softest (or most cushioned) midsoles and the least medial support. They are usually built on a semicurved or curved last to encourage foot motion, which is helpful for underpronators (who have rigid, immobile feet). Cushioning marathon shoes recommended for the high-arched runner, whose foot may roll outward (supinate) rather than the natural slight inward roll, or whose feet may be relatively rigid. Cushioning shoes emphasize flexibility and usually are built on a curved or semicurved last to encourage a normal motion of the foot. Cushioning shoes usually offer no medial (inner foot) support. Cushioned marathon shoes have the single-density midsole, which is stable and relatively firm for a cushioned shoe, stays the same. But the forefoot is more rounded, and the rearfoot now includes a new and supportive rearfoot cradle. A foam midsole, perhaps with layers of different densities, to provide cushioning and shock absorption. EVA (ethylene vinyl acetate) and PU (polyurethane), the materials from which these foams usually are made. EVA is slightly softer than PU. EVA and PU may be layered together in a shoe, or a shoe may have more than one density of EVA.

The Effects of Shoes with Rolling Feature on the Foot Reaction Force and Pronation (신발의 굴림 특성이 족저반력 및 회내운동에 미치는 영향)

  • Shin, Hak-Soo
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.189-195
    • /
    • 2007
  • The purpose of this study was to analyze the effects of shoes with curved out-sole on the pressure, reaction force(sum of pressure) on foot and relations between the rolling speeds and pronation of foot. The foot pressure, reaction force and pressure center on the foot surface of shoe were measured with NOVEL padar system, and 3 type shoes were used to compare the position and speed of pressure center and the foot reaction force, which were s(target) shoe with soft cushions in middle part of out-sole and curved out-sole, m shoes with two type- soft, hard, hardness out-sole and curved out-sole and n shoes with flat out-sole. The subjects were 13 female university students, had weared the 3 type shoes for 6 weeks on two-weeks shifts for adaptation before experiment and put on 3-type shoes repeatedly and randomly and walked on treadmill with 3.5km/h and 80 steps/min. The data were captured with 30Hz and readjusted with 5kgf threshold reaction force. The results can be summarized as follow. 1. There were no difference in maximum reaction force on initial contact period and total foot impact, but statistical difference in maximum reaction force on takeoff period : s, m, n in ascending order. 2. There were some difference in rolling speeds for support periods. At initial contact, the rolling speed of s shoes was fastest but at periods between first and second maximum reaction force, that of m shoes fastest. 3. There was a negative relation between rolling speeds and the length of lever arm on initial reaction force related to pronation. It seems shoes with various curved shapes and hardness could make effects on the rolling features and the rolling speed also have some relationships with walking efficiency, absortion of impact and pronation.

Reliability of 3D-Inertia Measurement Unit Based Shoes in Gait Analysis (관성센서 기반 신발형 보행 분석기의 신뢰성 연구)

  • Joo, Ji-Yong;Kim, Young-Kwan;Park, Jae-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.1
    • /
    • pp.123-130
    • /
    • 2015
  • Purpose : The purpose of this study was to investigate the reliability of 3D-inertia measurement unit (IMU) based shoes in gait analysis. This was done with respect to the results of the optical motion capturing system and to collect reference gait data of healthy subjects with this device. Methods : The Smart Balance$^{(R)}$ system of 3D-IMU based shoes and Osprey$^{(R)}$ motion capturing cameras were used to collect motion data simultaneously. Forty four healthy subjects consisting of individuals in 20s (N=20), 40s (N=13), and 60s (N=11) participated in this study voluntarily. They performed natural walking on a treadmill for one minute at 4 different target speeds (3, 4, 5, 6 km/h), respectively. Results : Cadence (ICC=.998), step length (ICC=.970), stance phase (ICC=.845), and double-support phase (ICC=.684) from 3D-IMU based shoes were in agreement with results of optical motion system. Gait data of healthy subjects according to different treadmill speeds and ages were matched to previous literature showing increased cadence and reduced step length for elderly subjects. Conclusion : Conclusively, 3D-IMU based shoes in gait analysis were a satisfactory alternative option in measuring linear gait parameters.

The Biomechanical Comparison of Running Shoes According to the Difference of Insole (인솔 차이에 따른 런닝화의 운동역학적 비교)

  • Jin, Young-Wan;Shin, Sung-Hwon
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.2
    • /
    • pp.51-59
    • /
    • 2007
  • These studies show that I applied to functional insole (a specific A company) for minimizing shocks and sprain people's ankle arising from running. How to an effect on human body which studied a kinematics and kinetics from 10 college students during experiments. This study imposes several conditions by barefoot, normal running shoes and put functional insole shoes ran under average $2.0{\pm}0.24\;m$/sec by motion analysis and ground reaction force that used to specific A company. First of all, motion analysis was caused by achilles tendon angle, angle of the lower leg, angle of the knee, initial sole angle and barefoot angle. The result of comparative analysis can be summarized as below. Motion analysis showed that statically approximates other results from achilles tendon angle (p<.01), initial ankle angle(p<.05), initial sole angle(p<.001) and barefoot angle(p<.001). Ground reaction force also showed that statically approximates other results from impact peak timing (p<.001), Maximum loading rate(p<.001), Maximum loading rate timing (p<.001) and impulse of first 20 percent (p<.001). Above experiment values known that there was statically difference between Motion analysis and Ground reaction force under absorbing of the functional insole shoes which was not have an effect on our body for kinetics and kinematics.

EMG Power Spectrum Analysis of Wearing Roller Shoes on Muscle Fatigue in the Lower Extremity during Walking (롤러 슈즈 착용 후 보행시 근피로 상태에서 하지근의 근전도 Power Spectrum 분석)

  • Kim, Youn-Joung;Yoon, Chang-Jin;Chae, Won-Sik;Lee, Min-Hyung;Kim, Hun-Soo;Jung, Mi-Ra
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.2
    • /
    • pp.239-245
    • /
    • 2007
  • The purpose of this study was to compare the electromyography signal's power spectrum mean and median tendencies appearing in the lower extremity during walking while wearing roller shoes. 9 male subjects volunteered who have no experience riding inline-skate or roller-skate, and have no record of musculoskeletal disorder. Subjects walked on treadmill twice for an hour (Once a week, one trial with the roller on and the other without roller, Walking velocity = 1.39 m/s). Electromyography was measured every 15 minute (0, 15, 30, 45, 60 minutes). Surface electrode sticked muscle at rectus femoris(R.F.), vastus lateralis(V.L.), vastus medialis(V.M.), biceps femoris(B.F.), tibialis anterior(T.A.), gastrocnemius lateralis(G.L.), gastrocnemius medialis(G.M.). At Rectus femoris, Vastus Lateralis, Vastus medialis, and Biceps femoris showed no statistically significant decrease of median frequency or mean edge frequency as time passes. Also, between two treatments (wearing the roller shoes vs not wearing the roller shoes), no statistically significant difference. After 60 minutes, mean edge frequency showed statistically significant decrease at tibalis anterior and after 45 minutes, mean edge frequency showed statistically significant decrease compared to wearing roller shoes without the wheels at gastrocnemius lateralis. At gastrocnemius medialis after 30 minutes, median frequency showed statistically significant decrease, and showed statistically significant difference compared to the control group. Wearing the roller shoes with wheels for a long time resulted in statistically significant decrease of mean edge frequency and median frequency in lower extremity, especially in shank muscles. Increase of wearing time of roller shoes and walking on a bumpy road wearing roller shoes with wheels result fatigue and thus, danger of injury.

The Study on effect of the Muscle Activities for Dietshoes (Backless) (다이어트신발(Barkless)이 근육 활성도에 미치는 영향에 관한 연구)

  • Lee, Chang-Min;Oh, Yeon-Ju;Lee, Kyung-Deuk;Park, Seung-Bum;Lee, Hoon-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.117-124
    • /
    • 2006
  • The modern convenient life formed by industrial development becomes lack of exercise and takes an interest in diet. Specially, professional walking shoes is developed as people take an interest in jogging, Those shoes, professional walking shoes or Dietshoes, increase exercise effects by change of heel types. Therefore, this study investigated motility effects by EMG experiment in order to measure Muscle Activities (MA) while wearing diet shoes (backless). Experiment was conducted by EMG measurement, from calf (gastrocnemius muscle), thigh (vastus muscle) and waist (erector spinae muscle), of 12 high school students. Exercise effects between the two shoes were analyzed by EMG (MF; Median Frequency, MPF; Mean Power Frequency, ZCR; Zero Crossing Rate). Results showed that the Dietshoes(MF: 48.21Hz, MPF: 65.0Hz, ZCR: 100.6Hz) had larger EMG value than that of Normal shoes(MF: 40.47Hz, MPF: 58.04Hz, ZCR: 82.09Hz). Also, in MA, the highest activities are showed in the calf, the second one is in waist, and last one is in thigh during gate. ANOVA between shoes in measurement parts showed significant effects in MF (gastrocnemius: p-value=.022, vastus laterals: p-value=.037, erector spinae: p-value=.082), MPF (gastrocnemius: p-value=.032, vastus laterals: p-value=.046, erector spinae: p-value=.090), and ZCR (gastrocnemius: p-value=.000, vastus laterals: p-value=.004, erector spinae: p-value=.134). And MA of Dietshoes is higher than that of Normal shoes, and decreasing rate of MA in Dietshoes is less than that of Normal shoes. Thus, this study validates exercise effects of Dietshoes.

Effect of High-heel Shoes on Muscle Activity of the Lower Limbs (신발 굽의 높이가 하지근육 근활성도에 미치는 영향)

  • Ma, Sang-Yeol;An, Seong-Ja
    • PNF and Movement
    • /
    • v.10 no.1
    • /
    • pp.35-41
    • /
    • 2012
  • Purpose : This study was conducted to identify the effects of high heel shoes on surface electromyography(EMG) activities fo tibialis anterior(TA), soles(S), and gastrocnemius(G) in 12 healthy women. Methods : Subjects were composed of three group(sports shoes, 5cm heel height shoes, and 9cm heel height shoes). The muscle activity of the TA, G, S in the lower leg were measured using a surface EMG. Results : Results of one way repeated measures ANOVA of the after waling 30minutes standing task duration among the sport shoes, 5cm, and 9cm heel height conditions. The comparison of the muscular activities showed significant differences in the G muscles among the high heel shoes. Conclusion : Wearing high heel shoes for hours will bring inappropriate alignment of the lower limbs and cause postural changes or abnormal sensation and several other problems in the body, resulting in exposure to ankle sprain or fall injuries.

A comparison study for mask plantar pressure measures to the difference of shoes in 20 female (20대 여성의 신발종류에 따른 족저압 영역별 비교 연구)

  • Kim, Y.J.;Ji, J.G.;Kim, J.T.;Hong, J.H.;Lee, J.S.;Lee, H.S.;Park, S.B.
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.83-98
    • /
    • 2004
  • The purpose of this study was to investigate the test-retest of plantar pressures using the F-Scan system over speeds and plantar regions. 6 healthy female subjects in 20's were recruited for the study. Plantar pressure measurements during locomotor activities can provide information concerning foot function, particularly if the timing and magnitude of the loading profile can be related to the location of specific foot structures such as the metatarsal heads. The Tekscan F-Scan system consists of a flexible, 0.18mm thick sole-shape having 1260 pressure sensors, the sensor insole was trimmed to fit the subjects' right. left shoes - sneakers shoes & dress shoes. It was calibrated by the known weight of the test subject standing on one foot. The Tekscan measurements show the insole pressure distribution as a function of the time. This finding has important implications for the development of plantar pressure test protocols where the function of the forefoot is important. According to the result of analysis it is as follows 1) Center of force trajectory in women's dress shoes display direct movement, compare with center of force trajectory in Sneaker shoes displays a little bit curved slow pronation movement. Sneaker shoes in forefoot part display very quick supination movement, therefore, this shoes effects negative effectiveness for ankle's stability Considering center of force trajectory analyzing the more center of force close straight line, the more movement can be quick movement for locomotion. For foot pressure distribution, center of force trajectory in locomotion is better to curved trajectory with pronation movement. So sneaker shoes style is good shoes considering center of pressure distribution trajectory compare with women's dress shoes. 2) Women's dress shoes increased peak pressure in medial, this is effected by high hill's height. The more increased women's dress shoes's height, the more women's peak pressure will increase, pronation can increase compare with before. Supination movement increase, this focused pressure in lateral, also, supination increased more. If the supination movement increased, foot pressure focused in lateral, therefore, it is appeared force distribution in gait direction. This is bad movement in foot's stability. 3) Women's dress shoes in landing phase displayed a long time, this is when women's dress shoes wear, gait movement is unbalance, so, landing phase displayed a long time. For compensation in gait, swing phase quick movement. 4) Women's dress shoes displayed peak pressure distribution in lateral of rearfoot part, Sneakers shoes displayed peak pressure distribution in medial of forefoot part. Its results has good impact absorption compare with women's dress shoes. In forefoot part, sneakers shoes has good propulsive force compare with women's dress shoes.

A Study of In-sole Plantar Pressure Distribution in Functional Tennis Shoes (기능성 전문테니스화의 족저압력분포 분석)

  • Lee, J.S.;Kim, Y.J.;Park, S.B.
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.3
    • /
    • pp.99-118
    • /
    • 2004
  • The aim of this study is to evaluate tennis shoes's plantar pressure distribution in tennis prayers and to determine the influence of the shoe on various tennis movements. When investigating the biomechanics of movement in tennis, one of the first things to do is to understand the movement patterns of the sport, specifically how these patterns relate to different tennis shoes. Once these patterns are understood, footwear company can design tennis shoes that match the individual needs of tennis players. Plantar pressure measurement is widely employed to study foot function, the mechanical pathogenesis for foot disease and as a diagnostic and outcome measurement tool for many performance. Measurements were taken of plantar pressure distribution across the foot and using F-Scan(Tekscan Inc.) systems respectively. The F-Scan system for dynamic in-shoe foot pressure measurements has enabled us to assess quantitatively the efficacy of different types of footwear in reducing foot pressures. The Tekscan F-Scan system consists of a flexible, 0.18mm thick sole-shape having 1260 pressure sensors, the sensor insole was trimmed to fit the subjects' right, left shoes. For this study 4 university male, high level tennis players were instructed to hit alternated forehand stroke, backhand stroke, forehand volley, backhand volley, smash, service movement in 4 different tennis shoes. 1. When impact in tennis movement, peak pressure distribution of landing foot displayed D>C>B>A, A displayed the best low pressure distribution. A style's tennis shoes will suggest prayer with high impact. If prayer with high impact feeling during pray in tennis wear A style, it will decrease injury, will have performance improvement. 2. When impact in tennis movement, plantar pattern of pressure distribution in landing foot displayed B>A>C>D in stability performance. During tennis, prayer want to stability movement suggest B style tennis shoes when tennis movement impact keep stability of human body. B style tennis shoes give performance improvement 3. When impact in tennis movement, plantar pattern of center of force(C.O.F.)trajectory in landing foot analyzed this : 1) When stroke movement and volley movement in tennis, prayer better to rearfoot movement. 2) when service movement, prayer midfoot strike movement. 3) when smash movement, prayer have forefoot strike movement.

The Differences of the Normalized Jerk According to Shoes, Velocity and Slope During Walking (보행시 신발, 속도, 그리고 경사도에 따른 정규 저크의 차이)

  • Han, Young-Min;Choi, Jin-Seung;Kim, Hyung-Sik;Lim, Young-Tae;Yi, Jeong-Han;Tack, Gye-Rae;Yi, Kyung-Ok;Park, Seung-Bum
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.2
    • /
    • pp.1-8
    • /
    • 2006
  • The purpose of this study was to evaluate normalized jerk according to shoes, slope, and velocity during walking. Eleven different test subjects used three different types of shoes (running shoes, mountain climbing boots, and elevated forefoot walking shoes) at various walking speeds(1.19, 1.25, 1.33, 1.56, 1.78, 1.9, 2, 2.11, 2.33m/sec) and gradients(0, 3, 6, 10 degrees) on a treadmill. Since there were concerns about using the elevated forefoot shoes on an incline, these shoes were not used on a gradient. Motion Analysis (Motion Analysis Corp. Santa Rosa, CA USA) was conducted with four Falcon high speed digital motion capture cameras. Utilizing the maximum smoothness theory, it was hypothesized that there would be differences in jerk according to shoe type, velocity, and slope. Furthermore, it was assumed that running shoes would have the lowest values for normalized jerk because subjects were most accustomed to wearing these shoes. The results demonstrated that elevated forefoot walking shoes had lowest value for normalized jerk at heel. In contrast, elevated forefoot walking shoes had greater normalized jerk at the center of mass at most walking speeds. For most gradients and walking speeds, hiking boots had smaller medio-lateral directional normalized jerk at ankle than running shoes. These results alluded to an inverse ratio for jerk at the heel and at the COM for all types of shoes. Furthermore, as velocity increased, medio-lateral jerk was reduced for all gradients in both hiking boots and running shoes. Due to the fragility of the ankle joint, elevated forefoot walking shoes could be recommended for walking on flat surfaces because they minimize instability at the heel. Although the elevated forefoot walking shoes have the highest levels of jerk at the COM, the structure of the pelvis and spine allows for greater compensatory movement than the ankle. This movement at the COM might even have a beneficial effect of activating the muscles in the back and abdomen more than other shoes. On inclines hiking boots would be recommended over running shoes because hiking boots demonstrated more medio-lateral stability on a gradient than running shoes. These results also demonstrate the usefulness of normalized jerk theory in analyzing the relationship between the body and shoes, walking velocity, and movement up a slope.