• Title/Summary/Keyword: split tube

Search Result 40, Processing Time 0.031 seconds

Study of Stirling Cryocooler Performance with different length of split tube (Split tube 길이변화에 따른 스터링 극저온 냉동기의 특성에 관한 연구)

  • 홍용주;박성제;고득용;김효봉;오군섭;김종학
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.37-40
    • /
    • 2001
  • A free piston and free displacer (FPFD) Stirling cryocooler for cooling infrared and cryo-sensor is currently under development at Korea Institute of Machinery & Materials. In this study, performance tests of stirling cryocooler with different length of split tube were performed to get characteristics of cryocooler. The Experimental results show the Stirling cryocooler with small volume of split tube has higher cooling power and faster response time.

  • PDF

Experimental Study of Fracture Control Blasting Using the Split Tube (Split tube를 이용한 균열 제어발파 현장 실험)

  • 백승규;류창하;선우춘;최병희;김재동
    • Explosives and Blasting
    • /
    • v.19 no.4
    • /
    • pp.5-10
    • /
    • 2001
  • 발파시 공벽 주변에서 방사상으로 발생하는 무수한 균열들을 제어하고 일정한 방향으로 절단면을 형성하기 위해서 split tube를 이용한 발파 방법에 대한 현장 실험을 실시하였다. 현장 실험결과 절단면을 발달시키고자 하는 방향으로 제어할 수 있었다. 계산에 의한 발파압력과 제어된 균열면의 길이를 비교하였다. 현장 벤치 벽면에서 에멀젼 계열 폭약의 발파 압력이 700㎫이상일 경우 균열을 원하는 방향으루 제어할 수 있었을 뿐만 아니라, 공경의 30배까지 균열이 전파되었다.

  • PDF

Posterior Cricoid Split with Costal Cartilage Grafting and T-tube Stenting for Treatment of Subglottic Stenosis (성문하협착증에서 윤상연골절개 및 윤상연골 후벽 늑연골 이식술과 T-tube stenting)

  • Sohn, Jin-Ho
    • Korean Journal of Bronchoesophagology
    • /
    • v.5 no.2
    • /
    • pp.182-190
    • /
    • 1999
  • OBJECTIVES : To determine the results of posterior cricoid split with costal cartilage graft in the treatment of moderate and severe subglottic stenosis in adults, and to assess the effect of T-tube as a stent in this surgery. PATIENTS AND METHODS : Four adults with moderate and severe subglottic stenosis who underwent posterior cricoid split with costal cartilage graft from 1994 to 1995. Three patients were male and one was female. All of the patients had acquired subglottic stenosis, 2 of whom had a bilateral vocal folds paralysis. The surgical procedure we used included a cricoid lamina split with costal cartilage grafting and T-tube stenting. Arytenoidectomy was a added in 2 patients with bilateral vocal folds paralysis. RESULTS : Three of the 4 patients underwent decannulation, and 1 is still undergoing treatment. 3 patients who underwent decannulation demonstrated marked improvement in their symptoms of airway obstruction and good postoperative voice quality. CONCLUSIONS : The posterior cricoidotomy lumen augmentation with costal cartilage grafting is a safe and effective technique for the treatment of moderate and severe subglottic stenosis in adults and T-tube is a good alternative stenting material for this procedure.

  • PDF

The Effects of the Refrigerant Charge on the Performance of an Air Conditioner with Capillary Tube Expansions (냉매충전량이 모세관 팽창장치를 가진 공기조화기의 성능에 미치는 영향)

  • 최은수;김종배
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.5
    • /
    • pp.359-364
    • /
    • 2002
  • A popular type of residential air conditioner is the split system which has two separate units: indoor and outdoor units During field installation of the split system, the potential exists for not setting the charge exactly to the manufacturer´s specifications. The objective of this study is to investigate the effects of the refrigerant charge on the performance of the air conditioner. An air conditioner with capillary tube expansions was tested for various refrigerant charges. The results indicated that the more charge resulted in the more flowrate of the refrigerant. The flowrate of the refrigerant was one of the most important factors to understand the e(sects of the charge on the performance of the air conditioner with capillary tube expansions. Under-charge results in wide region of superheated vapor of the refrigerant in the evaporator, while over-charge results in high temperature of the liquid refrigerant in the evaporator.

Buckling behavior of shape-memory alloy tube (형상기억합금 튜브의 buckling 거동)

  • Choi, Jeom-Yong
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.378-381
    • /
    • 2008
  • The buckling behavior of cylindrical shape-memory alloy and aluminum tube is investigated at room temperature using a split Hopkinson pressure bar and an Instron hydraulic machine with a specially designed recording system. The shape-memory alloy at superelastic property regime buckles gradually in quasi-static loading, and fully recovers upon unloading. However, the buckling of aluminum tube is sudden and catastrophic, and shows permanent deformation. This gradual buckling of shape-memory alloy is associated with the forward and reverse transformation of stress-induced martensite and seems to have a profound effect on the unstable deformation of tube structures made from shape-memory alloy.

  • PDF

Minimally Invasive Removal of an Intradural Cervical Tumor : Assessment of a Combined Split-Spinous Laminectomy and Quadrant Tube Retractor System Technique

  • Kwak, Young-Seok;Kim, Kyoung-Tae;Cho, Dae-Chul;Kim, Young-Baeg
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.4
    • /
    • pp.427-431
    • /
    • 2012
  • Conventional laminectomy is the most popular technique for the complete removal of intradural spinal tumors. In particular, the central portion intramedullary tumor and large intradural extramedullary tumor often require a total laminectomy for the midline myelotomy, sufficient decompression, and adequate visualization. However, this technique has the disadvantages of a wide incision, extensive periosteal muscle dissection, and bony structural injury. Recently, split-spinous laminectomy and tubular retractor systems were found to decrease postoperative muscle injuries, skin incision size and discomfort. The combined technique of split-spinous laminectomy, using a quadrant tube retractor system allows for an excellent exposure of the tumor with minimal trauma of the surrounding tissue. We propose that this technique offers possible advantages over the traditional open tumor removal of the intradural spinal cord tumors, which covers one or two cervical levels and requires a total laminectomy.

A study on the performance of a split system inverter air-conditioner at different operation conditions (분리형 인버터 에어컨의 운전조건에 따른 성능 연구)

  • Kim, Man-Hoe
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.1
    • /
    • pp.113-121
    • /
    • 1998
  • The performance evaluation of a residential split system inverter air-conditioner has been conducted analytically and experimentally at different system operating conditions. A simulation program for modelling an air-conditioning system which consists of a compressor, a condenser, a capillary tube, an evaporator and related attachments was developed on the basis of the Oak Ridge heat pump design model, MARK III. The accuracy of the simulation results for the compressor frequencies of 32, 68 and 79 Hz for the residential split system inverter air-conditioner has been estimated by comparing calculation results to the experimental data and parametric study has been performed to investigate the effect of design parameters and operation conditions on the system performance.

Design of a Mandrel for Expansion of the Tube of the Heat Exchanger (열교환기 튜브확관을 위한 맨드렐 설계)

  • Kang, H.S.;Kim, D.S.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.430-434
    • /
    • 2004
  • Specifically designed mandrel is needed to expand tube of the heat exchanger with inner grooves. Configuration of the expanded tube depends upon the shape and feeding velocity of the mandrel. 3D simulation software LS-DYNA was used to obtain optimum design conditions of the mandrel. We show how configuration of the expanded tube varies with different design parameters such as the approaching angle, diameter , and the feeding velocity of the mandrel. Material property data for analysis were obtained through experiments with SHPB ( Split Hopkinson Pressure Bars ).

  • PDF

A study about shape processing for the bend of the Copper-Tube that use Hair Pin Bending Machine (Hair Pin Bending Machine을 이용한 동 튜브 굽힘 성형가공에 관한 연구)

  • Kang, Heung-Sik;Kim, Dong-Sung;Heo, Sin;Hong, Sung-In
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1705-1708
    • /
    • 2003
  • The purpose of this study is to investigate the manufacturing technique on the U type Draw-Bending of inner grooved tube. This bending process make the U shape tube by Hair Pin Bending machine. The U type tube requires the quality of product that satisfy sufficient conditions for a heat exchanger. The mandrel components act the important roles that prevent wrinkles and keep the shape of cross section of bended tube at bending process. We performed the FEM simulation using LS-DYNA software and the bending test of inner groove tube and then, compared bending simulation with bending test results about mandrel ball diameter, mandrel position and optimal clearance between mandrel and tube.

  • PDF

The effect of the operating frequency and the length of the split tube on the performance for the Stirling cryocooler (작동주파수와 연결관 길이 변화가 스터링 냉동기의 성능에 미치는 영향)

  • 김효봉;박성제;홍용주;고득용;김종학;유병건;박종호
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.2
    • /
    • pp.55-61
    • /
    • 2001
  • A free piston and free displacer (FPFD) Stirling cryocooler for cooling infrared and cryo-sensor is currently under development at korea Institute of Machinery & Materials. The FPFD Stirling cryocooler consists of two compressor pistons driven by linear motors which make pressure waves and a pneumatically driven displacer piston with regenerator. It is the most suitable design for a mechanical cryocooler utilized in night vision environment In this study, performance test of the Stirling cryocooler with different length of the split tube and operating frequency were performed to get characteristics of the cryocooler.

  • PDF