• 제목/요약/키워드: split of S2

검색결과 483건 처리시간 0.028초

처리온도(處理溫度)가 크레오소오트 약액(藥液)의 목재내(木材內) 흡수(吸收)에 미치는 영향(影響) (The effect of temperatures on the absorption of creosote solution by wood)

  • 이필우
    • 한국산림과학회지
    • /
    • 제5권1호
    • /
    • pp.16-21
    • /
    • 1966
  • This experiment was accomplished to study the effect affecting to the absorption of creosote solutions by treating temperatures 20, 50 and $80^{\circ}C$ when the small test pieces were treated as short timed immersion process. The test speciemens used in this experiment were cut into 180 pieces of $2.5{\times}2.5{\times}5cm$ size from the air dried sapwood of Righda Pine (Pinus rigida M.). They were controlled to about 8 to 9% moisture contents and measured specific gravities. Four creosote solutions of $S_1$(straight creosote), $S_2$(creosote 70% : heavy oil 30%), $S_3$(creosote 50% : heavy oil 50%) and $S_4$(creosote 30% : heavy oil 70%), and three treating temperatures of $T_1$($20^{\circ}C$), $T_2$($50^{\circ}C$) and $T_3$($80^{\circ}C$) were applied by factorial split plot design in the each treatment of 3, 7, 15, 30 and 60 minutes immersion. According to the results this study may be concluded briefly as follows : 1. In this immersion process the absorption effects of creosote mixtures by the increase of temperatures are recognized considerably in the each treating times. However in the straight creosote of treated solutions the effective differences were not shown but most effective differences were shown in the $S_2$ solution. 2. Although the solutional absorptions were raised considerably by temperature increase in every treating times the absorption effects of creosote mixtures were not reached to that of straight creosote because the effects are considerably lowered if the treating solutions were mixed with heavy oil even a small quantities. 3. The relations between the creosote contents of treating solutions and the absorptions in wood are shown as Fig. 1, 2, 3, 4 and 5. In these figures the absorption curves made by higher temperature treatment $T_3$ are on the lower treatments $T_1$ and $T_2$ if the solutions were mixed with heavy oil. 4. This report is a part of the consolidated results announced at the annual meetings of Korean Forestry Association in 1964 and 1965.

  • PDF

아동용 Luria-Nebraska 신경심리검사의 한국 표준화를 위한 예비연구 (A Preliminary Study for a Korean Version of the Luria-Nebraska Neuropsychological Battery-Children's Revision)

  • 강차연
    • 아동학회지
    • /
    • 제13권2호
    • /
    • pp.203-216
    • /
    • 1992
  • The purpose of this study was to investigate the utility of the Luria-Nebraska Battery-Children's Revision (LNNB-CR) in the clinical situation in Korea: LNNB-CR was applied clinically in order to examine how well it differentiates brain damaged children from normals. Subjects were 30 children with the average age of 10 years. Among them 15 were diagnosed as the 'brain damaged' group, and the remaining 15 were normal. All subjects of the two groups were tested on all items in accordance with LNNB-CR manual. Data were analyzed by percentage, correlation coefficient, and t-test. The results were (1) the degree of consistency between testers averaged 97.2% which confirmed the stability of the scoring system. (2) Split-half reliability was ranged from .75 on the Tactile Scale (C3) to .95 on the Memory Scale (C10). Thus, consistency of items within the scales appeared high. (3) Internal consistency reliability ranged from .74 on the Visual Scale (C4) to .98 on the Reading Scale (C9). Thus, the homogenity of items within the scales appeared high. (4) In the diagnostic discriminative power test between the two groups, both individual scales and total scores showed significant differences at the level of p<.001. (5) The discriminative power test between two groups on all items showed significant differences at the level of p<.05 or better in 126(85%) out of 149 items. These results are supportive of the diagnostic utility of the application of LNNB-CR to the clinical situation in Korea. However, extensive additional research is needed in order to prove its worth.

  • PDF

$CdGaInS_{4}:Er^{3+}$ 단결정의 광발광 특성 (Photoluminescence Properties of $CdGaInS_{4}:Er^{3+}$ Single Crystal)

  • 최성휴;김요완;강종욱;이봉주;방태환;현승철;김남오;김형곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.97-100
    • /
    • 2002
  • $CdGaInS_{4}:Er^{3+}$ single crystal crystallized in the rhombohedral. with lattice constants a = 3.899 $\AA$ and c = 36.970 $\AA$ for $CdGaInS_{4}:Er^{3+}$. The optical absorption measured near the fundamental band edge showed that the optical energy band structure of this compound had a direct and indirect band gaps. the direct and indirect energy gaps are found to be 2.665 and 2.479eV for $CdGaInS_{4}:Er^{3+}$ at 10 K. The photoluminescence spectra of $CdGaInS_{4}:Er^{3+}$ measured in the wavelength ranges of 500 nm~900 nm and 1500~1600 nm at 10 K. Eight sharp emission peaks due to $Er^{3+}$ ion are observed in the regions of 549.5~560.0nm. 661.3~676.5nm. 811.1~ 834.1 nm and 1528.2~1556.0 nm in $CdGaInS_{4}:Er^{3+}$ single crystal. These PL peaks were attributed to the radiative transitions between the split electron energy levels of the $Er^{3+}$ ions occupied at $C_{2v}$ symmetry of the $CdGaInS_4$ single crystals host lattice.

  • PDF

동적 물성치를 고려한 진공 인터럽터 충격특성의 영향인자 분석 (Parameter Study of Impact Characteristics for a Vacuum Interrupter Considering Dynamic Material Properties)

  • 임지호;송정한;허훈;박우진;오일성;안길영;최종웅
    • 대한기계학회논문집A
    • /
    • 제26권5호
    • /
    • pp.924-931
    • /
    • 2002
  • Vacuum interrupters in order to be used in various switch-gear components such as circuit breakers, distribution switches, contactors, etc. spread the arc uniformly over the surface of the contacts. The electrodes of vacuum interrupters are made of sinter-forged Cu-Cr materials for good electrical and mechanical characteristics. Since the closing velocity is 1-2m/s and impact deformation of the electrode depends on the strain rate at that velocity, the dynamic behavior of the sinter-forged Cu-Cr is a key to investigate the impact characteristics of the electrodes. The dynamic response of the material at the high strain rate is obtained from the split Hopkinson pressure bar test using disc-type specimens. Experimental results from both quasi-static and dynamic compressive tests are Interpolated to construct the Johnson-Cook model as the constitutive relation that should be applied to simulation of the dynamic behavior of the electrodes. The impact characteristics of a vacuum interrupter are investigated with computer simulations by changing the value of five parameters such as the initial velocity of a movable electrode, the added mass of a movable electrode, the wipe spring constant, initial offset of a wipe spring and the virtual fixed spring constant.

Effect of vibration during local anesthesia administration on pain, anxiety, and behavior of pediatric patients aged 6-11 years: A crossover split-mouth study

  • Hegde, Kuthpady Manasa;Neeraja, R;Srinivasan, Ila;Murali Krishna, DR;Melwani, Anjana;Radhakrishna, Sreeraksha
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제19권3호
    • /
    • pp.143-149
    • /
    • 2019
  • Background: Uncooperative behavior of children due to dental anxiety may interfere with the effective delivery of dental care and compromise the quality of treatment provided. Injection of local anesthesia is one of the most anxiety-inducing stimuli in pediatric dentistry. This study aimed to compare the efficacy of a child-friendly device, having a combined effect of vibration and distraction, with the conventional method of injection on pain, anxiety, and behavior of pediatric patients aged 6-11 years. Methods: This randomized, crossover, split-mouth study included 30 children requiring a bilateral inferior alveolar nerve block. The children were equally divided into two groups: group 1, aged 6-8 and group 2, aged 9-11 years. All children were injected with anesthesia using the conventional and device method in two separate sessions. They were assessed for anxiety by measuring the pulse rate before and during the administration of local anesthesia. Behavior was assessed using Faces, Legs, Activity, Cry, Consolability (FLACC) scale, and the child's experience while receiving anesthesia was assessed using the Wong Bakers Pain Rating Scale. Results: Results showed that the children who received local anesthesia using the device method had a lower mean pulse rate, FLACC scores, and pain rating scores than those who received local anesthesia using the conventional method. Conclusion: The device method was more effective than the conventional method in managing pain, anxiety, and behavior of patients aged 6-11 years. The device is a cost effective, simple, and child-friendly product for administrating local anesthesia in pediatric patients.

구리-크롬 소결단조 합금의 크롬 함유량 변화에 따른 동적 물성특성 (Dynamic Material Property of the Sinter-Forged Cu-Cr Alloys with the Variation of Chrome Content)

  • 송정한;허훈
    • 대한기계학회논문집A
    • /
    • 제30권6호
    • /
    • pp.670-677
    • /
    • 2006
  • Vacuum interrupters are used in various switch-gear components such as circuit breakers, distribution switches, contactors. The electrodes of a vacuum interrupter are manufactured of sinter-forged Cu-Cr material for good electrical and mechanical characteristics. Since the closing velocity is 1-2m/s and impact deformation of the electrode depends on the strain-rate at the given velocity, the dynamic material property of the sinter-forged Cu-Cr alloy is important to design the vacuum interrupter reliably and to identify the impact characteristics of a vacuum interrupter accurately. This paper is concerned with the dynamic material properties of sinter-forged Cu-Cr alloy for various strain rates. The amount of chrome is varied from 10 wt% to 30 wt% in order to investigate the influence of the chrome content on the dynamic material property. The high speed tensile test machine is utilized in order to identify the dynamic property of the Cu-Cr alloy at the intermediate strain-rate and the split Hopkinson pressure bar is used at the high strain-rate. Experimental results from both the quasi-static and the high strain-rate up to the 5000/sec are interpolated with respect to the amount of chrome in order to construct the Johnson-Cook and the modified Johnson-Cook model as the constitutive relation that should be applied to numerical simulation of the impact behavior of electrodes.

A New Steel Jacketing Method for Concrete Cylinders and Comparison of the Results with a Constitutive Model

  • Choi, Eun-Soo;Kim, Man-Cheol
    • International Journal of Railway
    • /
    • 제1권2호
    • /
    • pp.72-81
    • /
    • 2008
  • This paper introduces a new steel jacketing method for reinforced concrete columns with lap splice and evaluates its performance by a series of axial tests of concrete cylinders. At first, 45 concrete cylinders were fabricated with varying the design compressive strengths of 21, 27 and 35 MPa and, then, the part of them was jacketed with two-split-steel jackets under lateral confining pressure. The parameters in the first test were the steel jacket's thickness and the existence of adhesive between steel and concrete surface. In the second test, whole steel jackets were used to wrap cylinders with lateral pressure. Also, a double-layer jacket consisted of two steel plates was introduced; a cylinder was jacketed by two steel plates one after another. The effect of the new method was verified through comparing the results of the compressive tests for plain and jacketed cylinders. The steel jacket built following the new method showed good results of increasing the compressive strength and ductility of the jacketed cylinders with respect to the plain cylinders. The thicker steel jackets showed the more increased compressive strength, and the ductility at failure depended on the welding quality on steel jackets. The adhesive between steel and concrete surface reduced the confining effect of the steel jackets. The whole jacket showed more ductile behavior than the two-split jackets. The double-layered jackets were estimated to possess an equal performance to that of a single steel jacket having the same thickness of the double-layered jacket. Finally, the experimental results were compared with the constitutive model of steel-jacketed concrete; which showed a good agreement between the experimental results and the models.

  • PDF

이중동축 메탄/공기 층류 부분 예혼합화염에서의 화염구조와 자발광 배출 특성;안쪽관 연료주입의 영향 (Flame Structure and Light Emission Characteristics in Coaxial Laminar Partially Premixed $CH_{4}/Air$ Flames;Effect of Central Fuel Injection)

  • 오정석;정용기;전충환;장영준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1116-1121
    • /
    • 2004
  • In this study, the effect of central fuel injection on a coaxial laminar $CH_{4}/air$ flame was experimented at the defined premixing condition(${\Phi}=1.90$, ${\sigma}=50/75/100%$, x/D=10). The partial premixing parameter are the equivalence ratio that total fuel is fixed at 200cc/min, the fuel split degree which means the percentage of fuel entering the outer tube to the total amount, and the mixing distance indicating the nonreactant mixture's homogeneity between inner tube top and burner exit. The object is to investigate the flame structure and chemiluminescence characteristics of laminar partial premixed flame as changing mixing parameters. The radical signal was acquired from ICCD camera and PMT. Each intensity was compared with Abel inverted value for measuring the effect of background light on the peak signal location and the intensity at central preheat zone. The results show that the peak location of each radical was broaden as the fuel split degree increasing because the mixing quality was enhanced. and $OH^{\ast}$ is a good indicator for flame front between reaction and preheat zone. At last $CH_{2}^{\ast}$ has the same tendency with $CH^{\ast}$ but a thinner reaction zone than $CH^{\ast}$ due to a rapid decay on the burned gas side.

  • PDF

The research on static and dynamic mechanical properties of concrete under the environment of sulfate ion and chlorine ion

  • Nie, Liangxue;Xu, Jinyu;Bai, Erlei
    • Computers and Concrete
    • /
    • 제20권2호
    • /
    • pp.205-214
    • /
    • 2017
  • The Hydraulically driven test system and ${\Phi}100mm$ split Hopkinson pressure bar(SHPB) test device were employed to research the quasi-static and dynamic mechanical properties of concrete specimens which has been immersed for 60 days in sodium sulfate (group S1) and sodium chloride (group S2) solution, the evolution of their mass during corrosive period was explored at the same time, and the mechanism of performances lost was analyzed from the microscopic level by using scanning electron microscope. Results of the experimental indicated that: their law of mass both presents the trend of continuous rising during corrosive period, and it increases rapidly on the early days, the mass growth of group S1 and group S2 in first 7 days are 76.78% and 82.82% of their total increment respectively; during the corrosive period, the quasi-static compressive strength of specimens in two groups are significantly decreased, both of which present the trend of increase first and then decrease, the maximum growth rate of group S1 and group S2 are 7.52% and 12.71% respectively, but they are only 76.23% and 82.84% of specimens which under normal environment (group N) on day 60; after immersed for 60 days, there were different decrease to dynamic compressive strength and specific energy absorption, and so as their strain rate sensitivities. So the high salinity environment has a significant effect of weaken the quasi-static and dynamic mechanical performance of concrete.

Midinfrared Pulse Compression in a Dispersion-decreasing and Nonlinearity-increasing Tapered As2S3 Photonic Crystal Fiber

  • Shen, Jianping;Zhang, Siwei;Wang, Wei;Li, Shuguang;Zhang, Song;Wang, Yujun
    • Current Optics and Photonics
    • /
    • 제5권3호
    • /
    • pp.250-260
    • /
    • 2021
  • A tapered As2S3 photonic crystal fiber (PCF) with four layers of air holes in a hexagonal array around the core is designed in this paper. Numerical simulation shows that the dispersion D decreases and the nonlinearity coefficient γ increases from the thick to the thin end along the tapered PCF. We simulate the midinfrared pulse compression in the tapered As2S3 PCF using the adaptive split-step Fourier method. Initial Gaussian pulses of 4.4 ps and a central wavelength of 2.5 ㎛ propagating in the tapered PCF are located in the anomalous dispersion region. With an average power of assumed input pulses at 3 mW and a repetition frequency of 81.0 MHz, we theoretically obtain a pulse duration of 56 fs and a compression factor of 78 when the pulse propagates from the thick end to the thin end of the tapered PCF. When confinement loss in the tapered PCF is included in the simulation, the minimum pulse duration reaches 72 fs; correspondingly, the maximum compression factor reaches 61. The results show that in the anomalous-dispersion region, midinfrared pulses can be efficiently compressed in a dispersion-decreasing and nonlinearity-increasing tapered As2S3 PCF. Due to confinement loss in the tapered fiber, the efficiency of pulse compression is suppressed.