• Title/Summary/Keyword: split beam

Search Result 151, Processing Time 0.026 seconds

Vibration Analysis of a Beam Having n Through-the-width Splits (다수의 층상균열이 내재하는 보의 진동해석)

  • Hwang, J.K.;Lee, M.H.;Shin, Y.J.;Kim, C.H.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.5
    • /
    • pp.330-337
    • /
    • 2002
  • A frequency equation of beam subjected to the axial load and having ηthrough-the-width-splits is developed. The beam comprises of beam elements that are split into the upper and the lower part, and non-split beam elements. Equations of motion of each beam element are non-dimensionalized with respect to length. The frequency equation of beam is derived from that of each beam element, which satisfies the displacement of the longitudinal and transverse vibration and the boundary conditions between the beam elements. Numerical simulation and experimental work for the beam having several split beam elements are carried out to demonstrate the analytical development and its validity. The experimental results are in good agreement with those of the present frequency equation. The relationships between the split beam width and natural frequencies, and also the relationships between number of split and natural frequencies, in case that the total beam split length is same. are discussed.

Performance Characteristics of a 50-kHz Split-beam Data Acquisition and Processing System (50 kHz Split Beam 데이터 수록 및 처리 시스템의 성능특성)

  • Lee, Dae-Jae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.54 no.5
    • /
    • pp.798-807
    • /
    • 2021
  • The directivity characteristics of acoustic transducers for conventional single-beam echo sounders considerably limit the detection of fish-size information in acoustic field surveys. To overcome this limitation, using the split-aperture technique to estimate the direction of arrival of single-echo signals from individual fish distributed within the sound beam represents the most reliable method for fish-size classification. For this purpose, we design and develop a split-beam data acquisition and processing system to obtain fish-size information in conjunction with a 50-kHz single-beam echo sounder. This split-beam data acquisition and processing system consists of a notebook PC, a field-programmable gate array board, an external single-transmitter module with a matching network, and four-channel receiver modules operating at a frequency of 50-kHz. The functionality of the developed split-beam data processor is tested and evaluated. Acoustic measurements in an experimental water tank showed that the developed data acquisition and processing system can be used as a fish-sizing echo sounder to estimate the size distribution of individual fish, although an external single-transmitter module with a matching network is required.

Free vibration analysis of double split beams (이중 층상균열보의 자유진동해석)

  • Han, B.K;Lee, S.H
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.12
    • /
    • pp.2008-2018
    • /
    • 1997
  • In this study, free vibration analysis of double through-the-width split beam is studied based on the author's earlier work. Each segment which constructs double through-the-width split beam is considered as Timoshenko beam. The effect of coupling between longitudinal and transverse vibration on the natural frequencies of split beams is considered. Data acquisition and modal test of double split beam for clamped-free boundary condition are carried out. Experimental and numerical results obtained by ANSYS were compared with the calculated data by present theory and their comparisons give good agreement with one another. The influences of the size and location of double split, shear deformation, and boundary conditions on the natural frequencies are demonstrated for illustrative purpose. Effects of double split on the dynamic characteristics of beams can be used to detect the size and the location of damages in structures.

Development of a split beam transducer for measuring fish size distribution (어체 크기의 자동 식별을 위한 split beam 음향 변환기의 재발)

  • 이대재;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.196-213
    • /
    • 2001
  • A split beam ultrasonic transducer operating at a frequency of 70 kHz to use in the fish sizing echo sounder was developed and the acoustic radiation characteristics were experimentally analyzed. The amplitude shading method utilizing the properties of the Chebyshev polynomials was used to obtain side lobe levels below -20 dB and to optimize the relationship between main beam width and side lobe level of the transducer, and the amplitude shading coefficient to each of the elements was achieved by changing the amplitude contribution of elements with 4 weighting transformers embodied in the planar array transducer assembly. The planar array split beam transducer assembly was composed of 36 piezoelectric ceramics (NEPEC N-21, Tokin) of rod type of 10 mm in diameter and 18.7 mm in length of 70 kHz arranged in the rectangular configuration, and the 4 electrical inputs were supplied to the beamformer. A series of impedance measurements were conducted to check the uniformity of the individual quadrants, and also in the configurations of reception and transmission, resonant frequency, and the transmitting and receiving characteristics were measured in the water tank and analyzed, respectively. The results obtained are summarized as follows : 1. Average resonant and antiresonant frequencies of electrical impedance for four quadrants of the split beam transducer in water were 69.8 kHz and 83.0 kHz, respectively. Average electrical impedance for each individual transducer quadrant was 49.2$\Omega$ at resonant frequency and 704.7$\Omega$ at antiresonant frequency. 2. The resonance peak in the transmitting voltage response (TVR) for four quadrants of the split beam transducer was observed all at 70.0 kHz and the value of TVR was all about 165.5 dB re 1 $\mu$Pa/V at 1 m at 70.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The resonance peak in the receiving sensitivity (SRT) for four combined quadrants (quad LU+LL, quad RU+RL, quad LU+RU, quad LL+RL) of the split beam transducer was observed all at 75.0 kHz and the value of SRT was all about -177.7 dB re 1 V/$\mu$Pa at 75.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The sum beam transmitting voltage response and receiving senstivity was 175.0 dB re 1$\mu$Pa/V at 1 m at 75.0 kHz with bandwidth of 10.0 kHz, respectively. 3. The sum beam of split beam transducer was approximately circular with a half beam angle of $9.0^\circ$ at -3 dB points all in both axis of the horizontal plane and the vertical plane. The first measured side lobe levels for the sum beam of split beam transducer were -19.7 dB at $22^\circ$ and -19.4 dB at $-26^\circ$ in the horizontal plane, respectively and -20.1 dB at $22^\circ$ and -22.0 dB at $-26^\circ$ in the vertical plane, respectively. 4. The developed split beam transducer was tested to estimate the angular position of the target in the beam through split beam phase measurements, and the beam pattern loss for target strength corrections was measured and analyzed.

  • PDF

Effect of confined concrete on compressive strength of RC beams

  • Radnic, Jure;Markic, Radoslav;Harapin, Alen;Matesan, Domagoj
    • Advances in concrete construction
    • /
    • v.1 no.3
    • /
    • pp.215-225
    • /
    • 2013
  • The results of experimental testing of the effect of confined concrete on compressive strength and ductility of concrete beam subjected to pure bending are presented. The effect of different stirrups forms and spacing, as well as different concrete strengths, on beam carrying capacity and ductility were analyzed. Ultimate strength capacity and deflection of concrete beam increase with the decrease in stirrups spacing. Stirrup form has a great effect on the ultimate carrying capacity and ductility of concrete beam. Stirrups which confined the region of concrete in the compression more contribute to greater compression strength of concrete than common stirrups at the perimeter of the entire cross-section of the beam.

Real-Time Implementation of Active Classification Using Cumulative Processing (누적처리기법을 이용한 능동표적식별 시스템의 실시간 구현)

  • Park, Gyu-Tae;Bae, Eun-Hyon;Lee, Kyun-Kyung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.2
    • /
    • pp.87-94
    • /
    • 2007
  • In active sonar system, aspect angle and length of a target can be estimated by calculating the cross-correlation between left and right split-beams of a LFM(Linear Frequency Modulated) signal. However, high-resolution performances in bearing and range are required to estimate the information of a remote target. Because a certain higher sampling frequency than the Nyquist sampling frequency is required in this performance, an over-sampling process through interpolation method should be required. However, real-time implementation of split-beam processing with over-sampled split-beam outputs on a COTS(commercial off-the-shelf) DSP platform limits its performance because of given throughput and memory capacity. This paper proposes a cumulative processing algorithm for split-beam processing to solve the problems. The performance of the proposed method was verified through some simulation tests. Also, the proposed method was implemented as a real-time system using an ADSP-TS101.

FDOA Detection of Split-beam Transducers by Transfer Function Estimation (전달함수 추정에 의한 Split-beam 변환기의 FDOA 탐지)

  • Park Hae-young;Park Soon-jong;Kim Moo-joon;Kim Chun-duck;Lee Chai-bong
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.119-120
    • /
    • 2004
  • Split-beam 트랜스듀서의 입력신호로써 Sweep 신호를 구동한 어군탐지기 SONAR에 대하여 기술한다. Sweep 신호의 대역폭은 트랜스듀서 공진 대역의 대역폭에서 주파수 이동 변환하였다. 목표 대상물의 방위각 추정은 각 수신 채널 사이의 크로스-스펙트럼을 사용하여 추정한다. 추정 방위각의 정확도는 제안한 시스템의 알고리듬에 관계하고 있다.

  • PDF

Utility Evaluation of Split VMAT Treatment Planning for Nasopharyngeal cancer (비인두암 Split VMAT 치료계획 유용성 평가)

  • Tae Yang Park;Jin Man Kim;Dong Yeol Kwon;Jun Taek Lim;Jong Sik Kim
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.13-20
    • /
    • 2022
  • Purpose : IMRT using Tomotherapy during nasopharyngeal cancer radiation therapy irradiate an accurate dose to tumor tissues and is effective to reduce a dose rapidly in normal tissues. However, this has high MU and long Beam On Time. This study aims to analyze differences in tumors, normal tissues and low-dose distributions and the efficiency of Split VMAT after applying Helical IMRT (Tomotherapy), VMAT (Linac : 2Arc) and Split VMAT (Linac : 4Arc) plans. Materials and Methods : This study targeted ten nasopharyngeal cancer patients of this hospital and compared three treatment plans (Helical IMRT, VMAT, Split VMAT). For Helical IMRT planning, Precision® (Version 1.1.1.1, Accuray, USA) was used, and for VMAT and Split VMAT planning, Pinnacle (Version 9.10, Philips, USA) was used. The total dose applied was 38.4 Gy / 32 Gy (Daily Dose 2.4 Gy (GTV + 0.3 cm) / 2 Gy (CTV + 0.3 cm) 16Fx), and for GTV + 0.3 cm (P_GTV), 95% of V38.4Gy was prescribed. VMAT with an angle of 360° 2Arc was applied, and for Split VMAT, the field was divided into the right, the left, the top and the bottom and an angle of 360° 4Arc, 6MV was set. For evaluating the quality of the treatment plans, differences in tumors, normal tissues and low-dose area were compared, and Beam On Time was measured to analyze the efficiency. Results : When calculating the mean values of evaluation items of the three treatment plans (Helical IMRT, VMAT, Split VMAT) for the patients, the H.I (Homogeneity Index) of P_GTV was 1.04, 1.11 and 1.1 respectively, and the C.I (Confomity Index) of P_CTV was 1.03, 0.99 and 1.00 respectively. The mean dose of RT Parotid Gland (Gy) was 14.54, 17.06 and 14.76 respectively, the mean dose of LT Parotid Gland (Gy) was 14.32, 17.32 and 15.09 respectively, the maximum dose of P_Cord (Spinal Cord + 0.3 cm) (Gy) was 20.57, 22.59 and 21.06 respectively, and the maximum dose of Brain Stem (Gy) was 22.35, 23.99 and 21.68 respectively. The 50% isodose curve (cc) was 1332, 1132.5 and 1065.2 respectively. Beam On Time (sec) was 373.7, 130.7 and 254.4 respectively. Conclusion : Displaying a similar treatment plan quality to Helical IMRT, which is used a lot for head and neck treatment, Split VMAT reduced the low-dose area and Beam On Time and produced a better result than VMAT. Therefore, it is considered that Split VMAT is effective not only for nasopharyngeal cancer but also for other head and neck cancers.

Development of Split-beam Acoustic Transducer for a 50 kHz Fish Sizing Echo Sounder (50 kHz 체장어군탐지기용 분할 빔 음향 변환기의 개발)

  • Lee, Dae-Jae;Lee, Won-Sub
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.44 no.4
    • /
    • pp.413-422
    • /
    • 2011
  • An improved split-beam transducer for a 50 kHz fish-sizing echo sounder was developed. The main objective of this study was to minimize the side lobe level in the beam pattern and the distance between acoustic centers for adjacent transducer quadrants in the geometrical arrangement of array elements while maintaining a given number of transducer elements and beam width. To achieve these goals, a 32-element planar array transducer ($6{\times}6$ array with one element in each corner missing) was designed using the Dolph-Chebyshev shading function to suppress side lobes in the array beam pattern and fabricated by arranging the inter-element spacing to be substantially equal to half the wavelength using the transducer element of 0.4 times the wavelength in diameter. The performance characteristics of this split-beam transducer were evaluated in the experimental water tank of $5m{\times}5m{\times}6m$ (length${\times}$height${\times}$width). In this study, the design goal of the beam width and side lobe level for transmitting a beam pattern was initially set at $21^{\circ}$ and -30 dB, respectively. However, the measured beam width at 3 dB was $21^{\circ}$ in both directions with side lobe levels of -24.7 dB in the horizontal plane and -25.6 dB in the vertical plane. The averaged beam width at -3 dB of the receiving beam patterns for four receiving quadrants was $31.4^{\circ}$. The transmitting voltage response was 161.5 dB (re $1{\mu}Pa$/V at 1 m) at 50.23 kHz with a bandwidth of 2.16 kHz, and the averaged receiving sensitivity for four receiving quadrants was -178.13 dB (re 1 V/${\mu}Pa$) at 49.8 kHz with a bandwidth of 2.64 kHz.

A Study on the Development of a pub level Silica Measuring Technology by the Split-beam Type System (스플리트빔 형태의 고정도 단위 실리카 측정기술 개발에 관한 연구)

  • 정경열;류길수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.382-388
    • /
    • 2002
  • Dissolved silica is one of fatal components at a boiler facility Therefore, a dissolved silica measurement system should be equipped for managing efficiently the boiler facility. Most of silica measurement systems are composed of a sensor module of single-beam type structure, and silica density is measured with a infrared spectrometry using the Lambert-beer method. However, such a system occurs measuring error of large range and inconsistency of a light source, because of measuring a standard sample and a measuring sample alternatively. This paper introduces a method that the sensor module has a split-beam type structure and a tungsten lamp. The proposed system can measure silica density quickly and precisely more than those composing of a single-beam type structure, because of measuring and comparing with two samples at a same time. And examination results are shown to compare efficiencies of the system and existing commercial products, and for an ammonia influence.