• 제목/요약/키워드: splice length

검색결과 128건 처리시간 0.026초

결속선이 R/C보의 거동에 미치는 영향에 대한 실험적 연구 (An Experimental Study on the Effect of Tie-wire on R/C Beam Behaviors)

  • 변항룡;공귀옥;김준성;이수곤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 가을 학술발표회 논문집
    • /
    • pp.737-742
    • /
    • 1997
  • In this paper the effect of tie wire in lap spliced bars is investigated by experiment. The variables considered in the beam behaviors are beam dimension, lapped splice length and numbers of tie wire. 3 test pieces having the same variables consist one series and a total of 6 series ar tested. The test results show the beam behavior is not affected by numbers of tie wire but by the manner of tie. It was revealed hat the load bearing capacity of the beam is increased when the tie wire is extended to top bar.

  • PDF

비접촉 겹침 이음된 프리캐스트 U형 보의 휨성능에 미치는 효과 (Effect of Flexural Performance on U-Shaped Precast Concrete Beams with Noncontact Lapped Splice)

  • 하상수;김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권6호
    • /
    • pp.119-128
    • /
    • 2008
  • 본 연구는 중진지역에서의 PC(precast conctete) 보-기둥 접합부의 새로운 모멘트-저항 시스템을 제안하는 것이다. 철근 이음형 접합부에서 연결재는 접합부를 관통하고, U형 하프 PC 보의 하부철근과 비접촉 겹칩이음으로 연결되어 있다. 비접촉 겹침이음에 대한 성능을 파악하기 위하여 실험적 연구와 해석적 연구가 수행되었다. 실험의 주요변수는 겹침길이, 연결재의 크기, 그리고 겹침이음된 연결재의 거리 등이다. 또한, 균열양상, 하중-변위 곡선, 내력 비교, 그리고 연결재의 변형 등에 초점을 맞추어 해석적 연구를 수행하여 실험결과와 비교하였다. 해석과 실험 결과 주요변수인 겹침길이, 연결재의 크기, 연결재의 비접촉 수직 거리등에 따라 강도, 연성, 그리고 접합부 거동에 큰 영향을 주는 것으로 나타났다.

A Study of 100 tonf Tensile Load for SMART Mooring Line Monitoring System Considering Polymer Fiber Creep Characteristics

  • Chung, Joseph Chul;Lee, Michael Myung-Sub;Kang, Sung Ho
    • 한국해양공학회지
    • /
    • 제35권4호
    • /
    • pp.266-272
    • /
    • 2021
  • Mooring systems are among the most important elements employed to control the motion of floating offshore structures on the sea. Considering the use of polymer material, a new method is proposed to address the creep characteristics rather than the method of using a tension load cell for measuring the tension of the mooring line. This study uses a synthetic mooring rope made from a polymer material, which usually consists of three parts: center, eye, and splice, and which makes a joint for two successive ropes. We integrate the optical sensor into the synthetic mooring ropes to measure the rope tension. The different structure of the mooring line in the longitudinal direction can be used to measure the loads with the entire mooring configuration in series, which can be defined as SMART (Smart Mooring and Riser Truncation) mooring. To determine the characteristics of the basic SMART mooring, a SMART mooring with a diameter of 3 mm made of three different polymer materials is observed to change the wavelength that responds as the length changes. By performing the longitudinal tension experiment using three different SMART moorings, it was confirmed that there were linear wavelength changes in the response characteristics of the 3-mm-diameter SMART moorings. A 54-mm-diameter SMART mooring is produced to measure the response of longitudinal tension on the center, eye, and splice of the mooring, and a longitudinal tension of 100 t in step-by-step applied for the Maintained Test and Fatigue Cycle Test is conducted. By performing a longitudinal tension experiment, wavelength changes were detected in the center, eye, and splice position of the SMART moorings. The results obtained from each part of the installed sensors indicated a different strain measurement depending on the position of the SMART moorings. The variation of the strain measurement with the position was more than twice the result of the difference measurement, while the applied external load increased step-by-step. It appears that there is a correlation with an externally generated longitudinal tensional force depending on the cross-sectional area of each part of the SMART mooring.

겹침이음 길이가 짧은 RC 기둥의 이방향 횡하중 가력 실험 (Bidirectional Lateral Loading of RC Columns with Short Lap Splices)

  • 이창석;박이슬;한상환
    • 한국지진공학회논문집
    • /
    • 제24권1호
    • /
    • pp.19-27
    • /
    • 2020
  • Reinforced concrete (RC) buildings built in the 1980s are vulnerable to seismic behavior because they were designed without any consideration of seismic loads. These buildings have widely spaced transverse reinforcements and a short lap splice length of longitudinal reinforcements, which makes them vulnerable to severe damage or even collapse during earthquakes. The purpose of this study is to investigate the impact of bidirectional lateral loads on RC columns with deficient reinforcement details. An experimental test was conducted for two full-scale RC column specimens. The test results of deficient RC columns revealed that bidirectional loading deteriorates the seismic capacity when compared with a column tested unidirectionally. Modeling parameters were extracted from the tested load-displacement response and compared with those proposed in performance-based design standards. The modeling parameters proposed in the standards underestimated the deformation capacity of tested specimens by nearly 50% and overestimated the strength capacity by 15 to 20%.

50%주철근 겹침이음을 갖는 중실 및 중공 사각단면 교각의 거동특성 (Behavior of Solid and Hollow Rectangular RC Piers with 50% of Lap-Spliced Longitudinal Bars)

  • 김익현;이종석;이윤복;김원섭;선창호
    • 한국지진공학회논문집
    • /
    • 제7권5호
    • /
    • pp.25-35
    • /
    • 2003
  • 소성힌지영역에 50%의 주철근 겹침이음을 갖는 교각의 거동특성을 파악하기 위하여 축소교각모형실험을 수행하였다. 모델의 단면형상은 사각단면으로 중공 및 중실단면으로 각각 1기씩 제작하였다. 주철근은 연속철근과 주철근지름(d$_{b}$)의 39배의 겹침이음을 갖는 철근을 교대로 배치하였다. 겹침이음에 의한 거동특성을 파악하기 위하여 횡철근에 의한 구속효과와 축력에 의한 영향은 배제하였다. 두 시험체 모두 전형적인 휨파괴 형태를 보였으며 비교적 연성적인 거동을 나타내었다. 이로부터 50%의 주철근 겹침이음이 성능기초 내진설계를 위한 주철근상세의 하나의 대안으로서 유효성이 있음을 확인하였다.

Fatigue crack growth and remaining life estimation of AVLB components

  • Chen, Hung-Liang Roger;Choi, Jeong-Hoon
    • Structural Engineering and Mechanics
    • /
    • 제23권6호
    • /
    • pp.651-674
    • /
    • 2006
  • The fatigue cracks initiate and propagate in the Armored Vehicle Launch Bridge (AVLB) components, especially like the splice doubler angle, splice plate, and bottom chord, due to the cyclic loading by repeated AVLB-launchings and tank-crossings. In this study, laboratory fatigue tests were conducted on six aluminum 2014-T6, four aluminum 7050-T76511, and four ASTM A36 steel compact-tension specimens to evaluate the crack growth behavior of the materials used for the components. The experimental results provide the relationship (Paris Law) between crack growth rate, da/dn, and stress intensity range, ${\Delta}K$, whose material dependent constants C and m can later be used in the life estimation of the components. Finite Element Method (FEM) was used to obtain the stress intensity factor, K, of the components with cracks. Because of the complexity of loading conditions and component geometry, several assumptions and simplifications are made in the FEM modeling. The FEM results, along with the results obtained from laboratory fatigue tests, are then utilized to estimate critical crack length and remaining life of the components.

Prediction of the bond strength of ribbed steel bars in concrete based on genetic programming

  • Golafshani, Emadaldin Mohammadi;Rahai, Alireza;Kebria, Seyedeh Somayeh Hosseini
    • Computers and Concrete
    • /
    • 제14권3호
    • /
    • pp.327-345
    • /
    • 2014
  • This paper presents the application of multi-gene genetic programming (MGP) technique for modeling the bond strength of ribbed steel bars in concrete. In this regard, the experimental data of 264 splice beam tests from different technical papers were used for training, validating and testing the model. Seven basic parameters affecting on the bond strength of steel bars were selected as input parameters. These parameters are diameter, relative rib area and yield strength of steel bar, minimum concrete cover to bar diameter ratio, splice length to bar diameter ratio, concrete compressive strength and transverse reinforcement index. The results show that the proposed MGP model can be alternative approach for predicting the bond strength of ribbed steel bars in concrete. Moreover, the performance of the developed model was compared with the building codes' empirical equations for a complete comparison. The study concludes that the proposed MGP model predicts the bond strength of ribbed steel bars better than the existing building codes' equations. Using the proposed MGP model and building codes' equations, a parametric study was also conducted to investigate the trend of the input variables on the bond strength of ribbed steel bars in concrete.

Effectiveness of R/C jacketing of substandard R/C columns with short lap splices

  • Kalogeropoulos, George I.;Tsonos, Alexander G.
    • Structural Monitoring and Maintenance
    • /
    • 제1권3호
    • /
    • pp.273-292
    • /
    • 2014
  • The effectiveness of a retrofitting method for concrete columns with particular weaknesses is experimentally evaluated and presented in this paper. Structural deficiencies namely the inadequacy of transverse reinforcement and short length of lap splices are very common in columns found in structures built prior to the 1960s and 1970s. Recent earthquakes worldwide have caused severe damages and collapses of these structures. Nevertheless, the importance of improving the load transfer capacity between the deficiently lap-spliced bars is usually underestimated during the strengthening procedures applied in old buildings, though critical for the safety of the residents' lives. Thus, the seismic performance of the enhanced columns is frequently overestimated. The retrofitting approach presented herein involves reinforced concrete jacketing of the column sub-assemblages and welding of the lap-spliced bars to prevent the splice failure and conform to the provisions of modern design Codes. The cyclic lateral loading response of poorly confined original column specimens with insufficient lap splices and the seismic behavior of the retrofitted columns are compared. Test results clearly demonstrate that the retrofitting procedure followed is an effective way of significantly improving the seismic performance of substandard columns found in old buildings.

고강도 모르타르를 충전한 기계적 슬리브 철근이음에 대한 단조가력 하에서의 강성 평가 (Evaluation on Stiffness of Mechanical Sleeve Bar Splice Filling High-strength Mortar Under Monotonic Loading)

  • 김형기
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권4호
    • /
    • pp.79-88
    • /
    • 2012
  • 본 연구에서는 고강도 모르타르 충전식 기계적 슬리브 철근이음에 대한 단조가력 하에서의 강성을 보다 적절하게 평가하기 위하여, 슬리브 철근이음의 주요한 구조요소가 미치는 단조가력 하에서의 철근이음 강성에 대한 영향을 검토하였고 AIJ 규준에서 설정한 단조가력 하에서의 슬리브 철근이음에 대한 강성 기준과 비교평가하였다. 이것을 위하여 단조가력을 실시한 국내외 189여개 고강도 모르타르 충전식 기계적 슬리브 철근이음의 실험데이터를 조사하고 그 실험결과를 분석하였다. 그 결과, AIJ 규준에서 규정하는 목표 강성을 확보하는데 필요한 $f_g$(L/d)의 한계값을 철근의 종류와 슬리브의 종류에 따라서 각각 제시하였다.

Multiple transcripts of anoctamin genes expressed in the mouse submandibular salivary gland

  • Han, Ji-Hye;Kim, Hye-Mi;Seo, Deog-Gyu;Lee, Gene;Jeung, Eui-Bae;Yu, Frank H.
    • Journal of Periodontal and Implant Science
    • /
    • 제45권2호
    • /
    • pp.69-75
    • /
    • 2015
  • Purpose: Salivary fluid formation is primarily driven by Ca2+-activated, apical efflux of chloride into the lumen of the salivary acinus. The anoctamin1 protein is an anion channel with properties resembling the endogenous calcium-activated chloride channels. In order to better understand the role of anoctamin proteins in salivary exocrine secretion, the expression of the ten members of the anoctamin gene family in the mouse submandibular gland was studied. Methods: Total RNA extracted from mouse submandibular salivary glands was reverse transcribed using primer pairs to amplify the full-length coding regions of each anoctamin gene and was subcloned into plasmid vectors for DNA sequencing. Alternative splice variants were also screened by polymerase chain reaction using primer pairs that amplified six overlapping regions of the complementary DNA of each anoctamin gene, spanning multiple exons. Results: Multiple anoctamin transcripts were found in the mouse submandibular salivary gland, including full-length transcripts of anoctamin1, anoctamin3, anoctamin4, anoctamin5, anoctamin6, anoctamin9, and anoctamin10. Exon-skipping splicing in the N-terminal exons of the anoctamins1, anoctamin5, and anoctamin6 genes resulted in multiple alternative splice variants. No expression of anoctamin2, anoctamin7, or anoctamin8 was found. Conclusions: The predominant anoctamin transcript expressed in the mouse submandibular gland is anoctamin1ac. The chloride channel protein produced by anoctamin1ac is likely responsible for the $Ca^{2+}$-activated chloride efflux, which is the rate-limiting step in salivary exocrine secretion.