Browse > Article
http://dx.doi.org/10.5000/EESK.2020.24.1.019

Bidirectional Lateral Loading of RC Columns with Short Lap Splices  

Lee, Chang Seok (Department of Architectural Engineering, Hanyang University)
Park, Yi Seul (Department of Architecture Engineering, Hanyang University)
Han, Sang Whan (Department of Architectural Engineering, Hanyang University)
Publication Information
Journal of the Earthquake Engineering Society of Korea / v.24, no.1, 2020 , pp. 19-27 More about this Journal
Abstract
Reinforced concrete (RC) buildings built in the 1980s are vulnerable to seismic behavior because they were designed without any consideration of seismic loads. These buildings have widely spaced transverse reinforcements and a short lap splice length of longitudinal reinforcements, which makes them vulnerable to severe damage or even collapse during earthquakes. The purpose of this study is to investigate the impact of bidirectional lateral loads on RC columns with deficient reinforcement details. An experimental test was conducted for two full-scale RC column specimens. The test results of deficient RC columns revealed that bidirectional loading deteriorates the seismic capacity when compared with a column tested unidirectionally. Modeling parameters were extracted from the tested load-displacement response and compared with those proposed in performance-based design standards. The modeling parameters proposed in the standards underestimated the deformation capacity of tested specimens by nearly 50% and overestimated the strength capacity by 15 to 20%.
Keywords
Bidirectional loading; Modeling parameter; Lap splice; RC column;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Ghosh KK, Sheikh SA. Seismic upgrade with carbon fiberreinforced polymer of columns containing lap-spliced reinforcing bars. ACI Struct J. 2007;104:227-236.
2 Moon KH, Jeon YR, Lee CS, Han SW. Evaluation of Performance of Korean Existing School Buildings with Masonry Infilled Walls Against Earthquakes. Journal of the Earthquake Engineering Society of Korea. 2012 Dec;16(6):37-46.   DOI
3 Kim KM, Lee SH, Oh SH. Seismic Performance Evaluation of Existing Low-rise RC Frames with Non-seismic Detail. Journal of the Earthquake Engineering Society of Korea. 2013 May;17(6):97-105.   DOI
4 Di Ludovico M, Verderame GM, Prota A, Manfredi G, Cosenza E. Cyclic behavior of nonconforming full-scale RC columns. J Struct Eng. 2014;140:04013107.   DOI
5 Valluvan R, Kreger ME, Jirsa JO. Strengthening of column splices for seismic retrofit of nonductile reinforced concrete frames. ACI Struct J. 1993;90:432-440.
6 Lynn AC, Moehle JP, Mahin SA, Holmes WT. Seismic evaluation of existing reinforced concrete building columns. Earthq Spectra. 1996;12:715-739.   DOI
7 Melek M, Wallace JW. Cyclic behavior of columns with short lap splices. ACI Struct J. 2004;101:802-811.
8 Kim DH, Kim JC, Choi KK. Experimental Study for Investigating Seismic Performances of RC Columns with Non-Seismic Details. Journal of the Architectural Institute of Korea Structure & Construction. 2016;32(1):35-44.   DOI
9 Cho JY, Pincheira JA. Inelastic analysis of reinforced concrete columns with short lap splices subjected to reversed cyclic loads. ACI Struct J. 2006;103:280-290.
10 Lynn AC. Seismic evaluation of existing reinforced concrete building columns. Berkeley: University of California. c2001.
11 Aboutaha RS, Engelhardt MD, Jirsa JO, Kreger ME. Rehabilitation of shear critical concrete columns by use of rectangular steel jackets. ACI Struct J. 1999;96:68-78.
12 Harries KA, Ricles JM, Pessiki S, Sause R. Seismic retrofit of lap splices in nonductile columns using CFRP jackets. ACI Struct J. 2006;103:874-884.
13 Bousias SN, Verzeletti G, Fardis MN, Gutierrez E. Load-path effects in column biaxial bending with axial force. J Eng Mech. 1995;121:596-605.   DOI
14 Qiu F, Li W, Pan P, Qian J. Experimental tests on reinforced concrete columns under biaxial quasi-static loading. Eng Struct. 2002;24:419-428.   DOI
15 Del Zoppo M, Di Ludovico M, Prota A. Deformation capacity of non-conforming r.c. columns under compressive axial load and biaxial bending. Eng Struct. 2016;124:480-493.   DOI
16 Han SW, Kim T-O, Kim DH, Baek S-J. Seismic collapse performance of special moment steel frames with torsional irregularities. Eng Struct. 2017;141:482-494.   DOI
17 Cho J-Y, Pincheira JA. Nonlinear modeling of RC columns with short lap splices. 13th World Conference on Earthquake Engineering. BC: Vancouver. c2004.
18 Park CK, Lee BG, Song HW, Chung YS. Experimental Behavior of Reinforced Concrete Column-Bent Piers under Bidrectional Repeated Loading. Journal of the Earthquake Engineering Society of Korea. 2005;Feb;9(1):17-24.
19 Di Ludovico M, Verderame GM, Prota A, Manfredi G, Cosenza E. Experimental behavior of nonconforming RC columns with plain bars under constant axial load and biaxial bending. J Struct Eng. 2013;139:897-914.   DOI
20 Takizawa H, Aoyama H. Biaxial effects in modelling earthquake response of R/C structures. Earthq Eng Struct D .1976;4:523-552.   DOI
21 Kawashima KH, Ogimoto R, Hayakawa G. Effect of bilateral excitation on the seismic performance of reinforced concrete bridge columns. Proceedings of the 8th US National Conference on Earthquake Engineering, San Francisco, CA. c2006.
22 Rodrigues H. Biaxial seismic behaviour of reinforced concrete columns. Aveiro, Portugal: Departamento de Engenharia Civil, University of Aveiro. c2012.
23 Korea Concrete Institute. Concrete design code of Korea (KCI 2012). Seoul, Korea. c2012.
24 Korea Standards Association. KS F 2403. Standard Test Methods for Making and Curing Concrete Specimens. Republic of Korea. 2014.
25 Korea Standards Association. KS B 0802. Method of Tensile Test for Metallic Materials. Republic of Korea. 2018.
26 FEMA. Interim testing protocols for determining the seismic performance characteristics of structural and nonstructural components. Washington, DC: Federal Emergency Management Agency. c2007.
27 Rodrigues H, Arede A, Varum H, Costa AG. Experimental evaluation of rectangular reinforced concrete column behaviour under biaxial cyclic loading. Earthq Eng Struct D. 2013;42:239-259.   DOI
28 Tsuno K, Park R. Experimental study of reinforced concrete bridge piers subjected to bi-directional quasi-static loading. J Struct Mech Earthquake Eng. 2004;21:11s-26s.   DOI
29 Rodrigues H, Varum H, Arede A, Costa A. A comparative analysis of energy dissipation and equivalent viscous damping of RC columns subjected to uniaxial and biaxial loading. Eng Struct. 2012;35:149-164.   DOI
30 Leon R, Jirsa JO. Bidirectional loading of R.C. Beam-column joints. Earthq Spectra. 1986;2:537-564.   DOI
31 ASCE 41-17. Seismic Evaluation and Retrofit of Existing Buildings. Reston, VA: American Society of Civil Engineers. c2017.
32 Korea Infrastructure Safety & Technology Corporation. Evaluation Method of Seismic Performance on Existing Facilities (Buildings). RD-13-R3-058. Korea Infrastructure Safety & Technology Corporation. c2013.
33 Ghannoum WM, Matamoros AB. Nonlinear modeling parameters and acceptance criteria for concrete columns 297 ACI Special Publication. 2014. p. 1-24.
34 Sezen H, Moehle JP. Shear strength model for lightly reinforced concrete columns. J Struct Eng 2004;130:1692-1703.   DOI