• 제목/요약/키워드: spiral reinforcement ratio

검색결과 24건 처리시간 0.021초

Lateral strain-axial strain model for concrete columns confined by lateral reinforcement under axial compression

  • Hou, Chongchi;Zheng, Wenzhong
    • Structural Engineering and Mechanics
    • /
    • 제84권2호
    • /
    • pp.239-251
    • /
    • 2022
  • The use of lateral reinforcement in confined concrete columns can improve bearing capacity and deformability. The lateral responses of lateral reinforcement significantly influence the effective confining pressure on core concrete. However, lateral strain-axial strain model of concrete columns confined by lateral reinforcement has not received enough attention. In this paper, based on experimental results of 85 concrete columns confined by lateral reinforcement under axial compression, the effect of unconfined concrete compressive strength, volumetric ratio, lateral reinforcement yield strength, and confinement type on lateral strain-axial strain curves was investigated. Through parameter analysis, it indicated that with the same level of axial strain, the lateral strain slightly increased with the increase in the unconfined concrete compressive strength, but decreased with the increase in volumetric ratio significantly. The lateral reinforcement yield strength had slight influence on lateral strain-axial strain curves. At the same level of lateral strain, the axial strain of specimen with spiral was larger than that of specimen with stirrup. Furthermore, a lateral strain-axial strain model for concrete columns confined by lateral reinforcement under axial compression was proposed by introducing the effects of unconfined concrete compressive strength, volumetric ratio, confinement type and effective confining pressure, which showed good agreement with the experimental results.

나선철근교각의 내진성능에 관한 연구 (A Study on Seismic Performance of Spiral Prer)

  • 배성용;김광수;이형준;이재훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.363-368
    • /
    • 2000
  • The Korean Bridge Design Standard Specifications adopted the seismic design requirements in 1992. However, The current seismic design requirements for bridges are based on the USA seismic codes for sever earthquake. This provides the basic factors that affects the performance of spiral reinforced concrete piers for seismic loading, and The specimen tests are performed based on load-displacement, effective stiffness and displacement ductility, etc. The quasi-static test was adopted in order to investigate seismic performance of the spiral reinforced concrete pier specimens which had different transverse steel amount, spacing and longitudinal steel ratio under different axial load levels. This study is concluded that seismic design for transverse reinforcement content of spiral reinforced concrete column has influenced on axial load and effective stiffness etc.

  • PDF

겹침이음 상세에 따른 철근콘크리트 교각의 내진성능에 관한 실험적 연구 (The Experimental Study on Seismic Performance of RC Bridge Columns with Longitudinal Steel Lap Splice)

  • 석상근;손혁수;정철호;이재훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.553-558
    • /
    • 2001
  • Recent destructive seismic events demonstrated the importance of mitigating human casualties and serious property damages in design and construction of structures. The Korean Bridge Design Specifications (1992) adopted seismic design requirements based on the AASHTO specification, and minor modification was made in 2000. The longitudinal steel connection of reinforced concrete bridge column is sometimes practically unavoidable. The longitudinal reinforcement details affect seismic performance such as flexural failure and shear failure. This research aims to develop longitudinal steel connection details with confinement steel by experimental study for seismic performance of reinforced concrete bridge columns. Quasi-static test under three different axial load levels was conducted for 12 spiral column specimens. All the column specimens had the same aspect ratio of 3.5. The column specimens were transversely reinforced with spiral and with five different longitudinal steel connection. The final objective of this study is to suggest appropriate longitudinal reinforcement connection details for the limited ductility design concept and improve construction quality.

  • PDF

겹침이음 상세에 따른 철근콘크리트 교각의 내진성능 (Seismic Performance of RC Bridge Columns with Longitudinal Steel Lap Splice)

  • 이재훈;손혁수;석상근;정철호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.345-352
    • /
    • 2001
  • Recent destructive seismic events demonstrated the importance of mitigating human casualties and serious property damages in design and construction of structures. The Korean Bridge Design Specifications (1992) adopted seismic design requirements based on the AASHTO specification, and minor modification was made in 2000. The longitudinal steel connection of reinforced concrete bridge column is sometimes practically unavoidable. The longitudinal reinforcement details affect seisimc performance such as flexural failure and shear failure. This research aims to develop longitudinal steel connection details with confinement steel by experimental study for seismic performance of reinforced concrete bridge columns. Quasi-static test under three different axial load levels was conducted for 12 spiral column specimens. All the column specimens had the same aspect ratio of 3.5. The column specimens were transversely reinforced with spiral and with five different longitudinal steel connection. The final objective of this study is to suggest appropriate longitudinal reinforcement connection details for the limited ductility design concept and improve construction quality.

  • PDF

포스트텐션용 정착구의 하중전달 특성에 관한 연구 (Load Transfer Characteristics of Post-Tensioning Anchorage)

  • 김민수;김진근;유영섭;이상순
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.657-662
    • /
    • 2000
  • This paper presents the results from experimental study that investigated to explore the load transfer characteristics of post-tensioning anchorage zones. The experimental program investigated the primary variables which affect the ultimate load, lateral strains and crack width: concrete compressive strength, details of reinforcement and shape of anchorage. Through this research, it was found that the governing factor of the ultimate load was not compressive cylinder strength but tensile splitting strength. Ultimate load was increased and lateral strain was decreased as the ratio of spiral increased because the lateral expansion of th concrete inside the spiral was restrained by the spiral. Furthermore, the shape of anchorage which can diminish the wedge effect of anchorage and disperse the anchorage force in various depths was more effective.

  • PDF

내부 강관 보강 원형 R.C 기둥의 연성 거동 특성 (Ductility of Circular Hollow Reinforced Concrete Piers Internally Confined by a Steel Tube)

  • 한택희;한상윤;한금호;강영종
    • 한국방재학회 논문집
    • /
    • 제3권2호
    • /
    • pp.127-137
    • /
    • 2003
  • 구조적으로 콘크리트의 자중이 문제 시 되는 곳이나, 콘크리트의 재료비가 높은 경우, 수직부재로 중공 콘크리트의 사용이 경제적일 수 있다. 콘크리트의 구속효과를 발휘를 위해 외측 면을 띠철근으로 보강하고 내측 면에 강관을 삽입하여 보강한 원형 중공 콘크리트 기둥의 연성 거동에 관해 연구하였고, 압축강도와 콘크리트의 극한변형율을 증가시키는 구속력의 효과를 나타낸 Mander의 응력-변형률 관계를 사용하여, 모멘트-곡률 관계 해석을 유도하였다. 극한변형율에 영향을 주는 인자인 구속력을 발휘하는 철근의 철근비와 항복응력, 구속 콘크리트의 압축강도 등을 극한변형율과 횡철근비의 관계를 통하여, 강관 삽입된 원형 중공 철근콘크리트 기둥의 구속응력과 횡철근비의 관계식을 제안하였다. 제안된 횡철근비 관계식은 실험을 통하여 검증하였다.

형상비 4.0이고 축방향철근비 2.36 ~ 4.71%인 팔각형 중공단면 철근콘크리트 기둥의 파괴거동에 관한 실험적 연구 (Experimental Study on the Failure Behavior of RC Octagonal Hollow Section Columns with Aspect Ratio of 4.0 and Longitudinal Steel Ratio of 2.36 ~ 4.71%)

  • 고성현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권6호
    • /
    • pp.102-111
    • /
    • 2022
  • 본 논문의 목적은 팔각형 중공단면 철근콘크리트 교각의 내진성능을 평가하고 축방향철근비가 파괴거동에 미치는 영향을 분석함에 있다. 축소모형 팔각형 중공단면 기둥 실험체 4개를 제작하여 일정한 축력 하에서 반복 횡하중을 가력하는 실험을 수행하였다. 모든 실험체의 횡방향 나선철근 체적비는 0.206%로 일정하고 축방향철근비는 2.36 ~ 4.71%이다. 파괴거동과 내진성능을 분석하였고 겹침이음 실험체를 제외한 3개의 실험체는 최종단계에서 휨-전단 파괴거동을 보였다. 겹침이음 실험체를 제외한 실험결과에서 변위연성도와 누적 에너지소산 능력이 축방향철근비에 반비례하여 감소하는 경향을 나타내었다.

Numerical modelling of circular reinforced concrete columns confined with GFRP spirals using fracture-plastic model

  • Muhammad Saad Ifrahim;Abdul Jabbar Sangi;Shuaib H. Ahmad
    • Computers and Concrete
    • /
    • 제31권6호
    • /
    • pp.527-536
    • /
    • 2023
  • Fiber Reinforced Polymer (FRP) bar has emerged as a viable and sustainable replacement to steel in reinforced concrete (RC) under severe corrosive environment. The behavior of concrete columns reinforced with FRP bars, spirals, and hoops is an ongoing area of research. In this study, 3D nonlinear numerical modelling of circular concrete columns reinforced with Glass Fiber Reinforced Polymer (GFRP) bars and transversely confined with GFRP spirals were conducted using fracture-plastic model. The numerical models and experimental results are found to be in good agreement. The effectiveness of confinement was accessed through von-mises stresses, and it was found that the stresses in the concrete's core are higher with a 30 mm pitch (46 MPa) compared to a 60 mm pitch (36 MPa). The validated models are used to conduct parametric studies. In terms of axial load carrying capacity and member ductility, the effect of concrete strength, spiral pitch, and longitudinal reinforcement ratio are thoroughly investigated. The confinement effect and member ductility of a GFRP RC column increases as the spiral pitch decreases. It is also found that the confinement effect and member ductility decreased with increase in strength of concrete.

경계부재내 횡보강근 배근방법에 따른 R/C전단벽의 반복하중에 대한 이력거동 (Hysteretic Behavior of R/C Shear Wall with Various Lateral Reinforcements in Boundary Columns for Cyclic Lateral Load)

  • 서수연;오태근;김경태;윤승조
    • 콘크리트학회논문집
    • /
    • 제22권3호
    • /
    • pp.357-366
    • /
    • 2010
  • 이 연구에서는 경계부재내에 다양한 형태의 횡보강근 상세를 가진 전단벽에 대한 실험연구를 다루고자 한다. 연구의 주요 내용은 시공성 개선을 위해 사각나선 횡보강근과 헤드가 있는 크로스타이로 전단벽의 경계부재내 콘크리트를 구속함에 따른 거동을 실험적으로 관찰하는 것이다. 이 두 가지 상세는 공장에서 제작된 후 현장에서 조립만 할 경우, 현장작업량을 줄일 수 있는 상세로 고려될 수 있으며, 이 연구에서는 이 두 가지 상세를 가진 전단벽에 대한 구조성능을 구명하고자 한다. 실험의 주요변수는 경계부재내 횡보강근의 형태로서 기존의 띠철근, 사각나선근, 그리고 기존 크로스타이와 헤드가 있는 크로스타이를 사용한 경우로서, 총 4개의 바벨형상의 전단벽 실험체를 제작하고 일정 축력 아래에서 반복하중 실험을 통하여 그 성능을 평가한다. 콘크리트 공칭강도의 10%의 일정축력 작용상태에서 횡방향 반복가력을 실시하여 구조성능을 평가한다. 실험 결과 전단벽의 경계부재내 시공성 개선을 위해 제안된 사각나선근과 기계적 정착장치를 사용함으로써 재래의 보강방법과 거의 동등한 구조성능을 확보할 수 있는 것으로 나타났다. 또한 띠철근의 직경이 크고 횡보강근의 체적비가 다소 높은 SW-Hh시험체가 항복 이후 균열이 닫힌 다음 강성이 높아짐으로 인하여 전체적인 소산에너지 면적이 다른 시험체에 비하여 높게 나타났으나 최대강도 도달 이후 내력이 다소 급격히 저하되는 것으로 나타나 강도와 연성의 확보측면에서 횡보강근의 체적비와 함께 간격에 대한 고려가 필요한 것으로 판단된다.

Spiral 철근 배근된 전단벽 단부의 내진성능 연구를 위한 예비 고찰 (Preliminary Study on Boundary Detailing of Structural Wall with Spirals)

  • 김록배;홍성걸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2000년도 가을 학술발표회논문집(I)
    • /
    • pp.589-594
    • /
    • 2000
  • The necessary strength and ductility to avoid structural damage under moderate earthquake can be achieved by properly detailed transverse reinforcement in the plastic hinge zone. However, most structural walls have a higher aspect ratio(M/Vl\ulcorner) without well confined boundary regions. Therefore there is a need for adequate detailing in the plastic hinge zone, particularly boundary regions. In this paper, the fabricated interlocking spirals is introduced as a new seismic detailing for ductile behavior of the structural walls to be able to substitute for existing complicated detailing with ties. This paper also investigates the behavior characteristics of structural walls with interlocking spirals including confinement of the concrete and strength associated with flexure and shear.

  • PDF