• Title/Summary/Keyword: spiral flow

Search Result 188, Processing Time 0.034 seconds

An experimental investigation of flow characteristics in the tangential and the multi-stage spiral inlets (접선식 및 다단식 나선 유입구 흐름 특성의 실험적 연구)

  • Seong, Hoje;Rhee, Dong Sop;Park, Inhwan
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.3
    • /
    • pp.227-234
    • /
    • 2019
  • The vulnerability of urban disasters is increased with the rapid urbanization and industrialization, and the extreme rainfall event is increased due to the global climate change. Urban inundation is also increased due to the extreme rainfall event beyond the capacity limit of facility for the damage prevention. The underground detention vault and the underground drain tunnel are rapidly being utilized to prevent urban inundation. Therefore, the hydraulic review and design analysis of the inlet of the underground facility are important. In this study, the water level of the approach flow according to the inflow discharge is measured and the flow characteristic of the inlet (tangential and spiral) is analyzed. For the spiral inlet, the multi-stage is introduced at the bottom of the inlet to improve the inducing vortex flow at low discharge conditions. In case of the tangential inlet, the discharging efficiency is decreased rapidly with hydraulic jump in the high flow discharge. The rising ratio of the water level in the multi-stage spiral inlet is higher than the tangential inlet, but the stable discharging efficiency is maintained at low and high discharge conditions. And the empirical formula of water level-flow discharge is derived in order to utilize inlets used in this study.

A Study on Rheological Properties for Preparing Flow Mark Free PP Compounds (흐름자국이 없는 PP 복합소재 제조를 위한 유변학적 특성 연구)

  • Lee, Yong-Hee;Nam, Byeong-Uk;Lim, Jae-Gon;Choi, Chi-Hoon
    • Elastomers and Composites
    • /
    • v.44 no.2
    • /
    • pp.156-163
    • /
    • 2009
  • Our objective is to increase the flowability of Polypropylene(PP) compounds and achieve flow mark free surface in injection molded specimen. We have investigated flowabilities of PP compounds which were composed of PP, rubber, talc, and trace amount of additives. Flowability measurement was performed with four types PPs of which molecular weight distributions(MWD) and melt indexes(MI) were different. Rheological properties of the PP compounding materials, such as spiral flow(SF) length, MI, and shear viscosity, were evaluated. When PP with the broad MWD was used, there were remarkable cases where the spiral flow length of low MI PP compound was longer than that of higher MI PP compound. The PP compound having low MI but broad MWD PP has more flowability than the compound with only high MI.

COMPUTATIONAL STUDY FOR PERFORMANCE EVALUATION OF FLOW CHANNELS INSIDE CDI UNIT CELL (수치모사를 이용한 CDI Unit Cell 내부의 유로성능 평가)

  • Sohn, D.Y.;Choi, Y.H.;Park, D.W.;Jung, C.H.
    • Journal of computational fluids engineering
    • /
    • v.15 no.1
    • /
    • pp.31-36
    • /
    • 2010
  • In the present study, computations for flow fields inside the CDI unit cells with electrodes and spacers have been made to evaluate their performance. Three types of unit cells that include a planar type, a serpentine channel type, and a spiral wound type were considered and their flow characteristics were compared. From the computational results, it is found that the serpentine channel type has a large flow resistance and can not guarantee the outflow flux for industrial applications. On the other hand, the planar type can sustain a large enough outflow flux but it's efficiency is low for the electrode-use because of the non-uniform velocity distribution inside the cell and dead zones in every corner. Finally, The spiral wound type has not only a large outflow flux as much as the planar type has, but also a high efficiency for the electrode-use because of uniform velocity distribution. From this comparison, we can expect that the spiral wound type of CDI unit cell would have a high performance deionization capability.

Leakage and Rotordynamic Analysis of Spiral-Grooved Pump Seal Based on Three-Control-Volume Theory (나선 홈 펌프 실의 누설 및 로터다이내믹 해석)

  • Ha, Tae-Woong;Lee, An-Sung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.1 s.18
    • /
    • pp.14-22
    • /
    • 2003
  • In this paper the leakage prediction md rotordynamic analysis of an annular seal with a smooth rotor and spiral-grooved stator is performed. For the development of a theoretical model, the three-control-volume analysis of the circumferentially-grooved seal is expanded by considering pressure reduction due to the pumping effect of spiral groove and pressurized flow through the spiral groove. Validation on the present analysis is achieved by comparisons with available experimental data. For the leakage prediction the present analysis generally shows a reasonable agreement with experimental results. Rotordynamic coefficients for rotor speed with spiral angles show same trend, but the magnitudes of rotordynamic coefficients yield differences between analysis and experimental results.

Characteristic Analysis of Spiral-Grooved Pump Seal (나선 홈 펌프 시일의 특성 해석)

  • Ha, Tae-Woong;Lee, An-Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11b
    • /
    • pp.799-804
    • /
    • 2002
  • In this paper the leakage prediction and rotordynamic analysis of an annular seal with a smooth rotor and spiral-grooved stator are performed. For developing a theoretical model, the three-control-volume analysis of the circumferentially-grooved seal is expanded by considering pressure reduction due to the pumping effect of spiral groove and pressure flow through the spiral groove. Results by the present analysis are compared with available experimental data. For leakage the analysis results generally show a reasonable agreement to the experimental results. For rotordynamic coefficients the analysis results show the same trend as the experimental results for rotor speed with spiral angles, but their magnitudes show somewhat large deviations.

  • PDF

NAVIER-STOKES SIMULATION OF A VISCOUS MICRO PUMP WITH A SPIRAL CHANNEL (스파이럴 채널을 가진 초소형 점성 펌프의 Navier-Stokes 해석)

  • Seo, J.H.;Kang, D.J.
    • Journal of computational fluids engineering
    • /
    • v.16 no.1
    • /
    • pp.90-95
    • /
    • 2011
  • The Navier-Stokes equations are solved to study the flow characteristics of a micro viscous pump. The viscous micropump is consisted of a stationary disk with a spiral shaped channel and a rotating disk. A simple geometrical model for the tip clearance is proposed and validated by comparing computed flow rate with corresponding experimental data. Present numerical solutions show satisfactory agreement with the corresponding experimental data. The tip clearance effect is found to become significant as the rotational speed increases. As the pressure load increases, a reversed flow region is seen to form near the stationary disk. The height of the channel is shown to be optimized in terms of the flow rate for a given rotational speed and pressure load. The optimal height of the channel becomes small as the rotational speed decreases or the pressure load increases. The flow rate of the pump is found to be in proportion to the width of channel.

The Evaluation of Carotid Artery Stenosis Using Spiral CT. (Spiral CT를 이용한 경동맥 질환의 평가)

  • Yoon, Hee-Suk;Hwang, Yun-Chean;Shin, Hyun-Kil;Beak, Cheon-Ki;Yoon, Suck-Min
    • Journal of radiological science and technology
    • /
    • v.19 no.2
    • /
    • pp.45-49
    • /
    • 1996
  • To determine the utility of spiral computed tomography(CT) in the evaluation of carotid artery stenosis, spiral CT images of 10 patients were compared with both ones of conventional angiography and magnetic resonance(MR) angiography. The severeness of stenosis was determined for each Internal carotid artery on the basis of arterial narrowness : mild stenosis : 40 % or less, moderate stenosis = $40{\sim}70%$, severe stenosis = greater than 70 % of arterial narrowness. The short examination and clear depiction of the arterial lumen In areas of complex or low flow make CT angiography attractive alternative to MR angiography. Spiral CT angiography shows normal and abnormal carotid anatomy well when compared with conventional anglography.

  • PDF

Characteristic Analysis of Spiral-Grooved Pump Seal (나선 홈 펌프 시일의 특성 해석)

  • Ha, Tae-Woong;Lee, An-Sung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.379.1-379
    • /
    • 2002
  • In this paper the leakage prediction and rotordynamic analysis of an annular seal with a smooth rotor and spiral-grooved stator are performed. For developing a theoretical model, the three-control-volume analysis of the circumferentially-grooved seal is expanded by considering pressure reduction due to the pumping effect of spiral groove and pressure flow through the spiral groove. Validation to the present analysis is achieved by comparisons with available experimental data. (omitted)

  • PDF

Flow and Heat Transfer Characteristics of Tube-and-Plate Condenser with Different Plate Shapes and Inlet Geometries using Numerical Analysis (수치해석에 의한 TUBE-AND-PLATE형 응축기의 판 형태 및 입구 형상변화에 따른 유동 및 열전달 특성)

  • Choi, W.J.;Kwon, O.B.;Lim, H.C.;Kim, M.K.;Lee, Y.S.
    • Journal of Power System Engineering
    • /
    • v.13 no.2
    • /
    • pp.49-55
    • /
    • 2009
  • Recently, a study on condensers for refrigerators has focused on new model which will cost less and will be more efficient. Some widely used condensers for domestic refrigerators are wire-and-tube type condenser, hot-wall type condenser, and spiral type condenser. Some companies which use the spiral type condenser at the moment try to develop a new tube-and-plate type condenser which will cost less and will be as efficient as the spiral type. As a standard condenser type, tube-and-plate type condenser is used in this study. A two-dimensional numerical model for the tube-and-plate type condenser is proposed, and the flow and heat transfer characteristics for several types of condensers are investigated.

  • PDF