• Title/Summary/Keyword: spiked membrane

Search Result 25, Processing Time 0.016 seconds

Interlaboratory Study for Cryptosporidium and Giardia Test Methods in Water (정수장 원생동물 분석방법의 국내 실험실간 교차시험 연구)

  • Chung, Hyenmi;Park, Sangjung;Kim, Daekyun;Park, Sanghee;Kim, Reeho;Lee, Sangho;Cho, Joorae;Lee, Kyeunghee;Park, Jonggeun;Lee, Mokyoung;Byun, Seungheon;Cho, Eunju;Rhim, Yeontaek
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.321-327
    • /
    • 2006
  • This interlaboratory study was designed to evaluate protozoan test methods in water and to predict the major causes of deviation of the methods. Each of four laboratories with previous experience of protozoa analysis in water participated, and met the initial performance criteria of EPA 1623 method provided. The protozoan analysis procedure consists of filtrations, concentration, immunomagnetic separation, dyeing (staining) and counting with observation. We tested three different filtration equipments: capsule filter for 10 L of surface water, and high volume (HV) capsule filter and membrane filter for 100 L of finished water. When the recovery of each step of the procedure was evaluated with EasySeed, the commercial stock of each 100 Cryptosporidium and Giardia, immunomagnetic separation and filtration step were the most crucial steps affecting the stability of the recovery, especially for Cryptosporidium. There was no significant difference of recovery among the filtration methods. Recovery of protozoa from source water were evaluated with spiked EasySeed as matrix tests. The recoveries of Giardia increased significantly in the matrix tests compared those in the deionized water. We also applied red stained mixture stocks of Cryptosporidium and Giardia called ColorSeed as internal standards of water sample tests. The recoveries of both EasySeed and ColorSeed in samples tested were within the range of the criteria, however, the Giardia recoveries using ColorSeed decreased significantly. Further optimization study with ColorSeed will be necessary, considering the convenience of using the internal standard without additional sample analysis. The significant factors of the recovery variation were identified as the differences of laboratories as well as water quality and type of the stock for spiking. The results of this study emphasize the importance of the quality assurance program for protozoan analysis lab in water.

Preconcentration and Determination of Trace Cobalt and Nickel by the Adsorption of Metal-PDC Complexes on the Anion-Exchange Resin Suspension (금속-PDC 착물의 음이온교환 수지 상 흡착에 의한 흔적량 코발트와 니켈의 동시 예비농축 및 정량)

  • Han, Chul-Woo;In, Gyo;Choi, Jong-Moon;Kim, Sun Tae;Kim, Young-Sang
    • Analytical Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.608-615
    • /
    • 2000
  • A determination method of trace nickel and cobalt in water samples was studied and developed by adsorbing their complexes on ion exchange resin suspension. The analytical ions were formed as complexes with a ligand of APDC (ammonium pyrrolidinedithiocarbamate) and adsorbed on anion exchange resin of Dowex 2-X8. After the suspension was filtered out with membrane filter, the complexes were dissolved in HCl solution by an ultrasonic vibrator for ET-AAS determination. Several conditions were optimized as followings. pH of sample solution: 5.0, amount of ligand APDC: more than 430 times in mole ratio, the type and concentration of acid: 0.1 M HCl, and vibration time: 7 minutes. The addition of palladium in the HCl solution could improve the reproducibility and sensitivity by a matrix modification in the absorbance measurement. This procedure was applied for the analysis of three kinds of real water samples. The detection limits equivalent to 3 times standard deviation of blank were Co 0.36 ng/mL and Ni 0.27 ng/mL and recoveries in spiked samples were 99-102% for cobalt and 100-105% for nickel.

  • PDF

Determination of Uranium Isotopes in Spent Nuclear Fuels by Isotope Dilution Mass Spectrometry (동위원소희석 질량분석법을 이용한 사용후핵연료 중 우라늄 동위원소 정량)

  • Kim, Jung Suk;Jeon, Young Shin;Son, Se Chul;Park, Soon Dal;Kim, Jong Goo;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.450-457
    • /
    • 2003
  • The determination of uranium and its isotopes in spent nuclear fuels by isotope dilution mass spectrometry (IDMS) has been studied. The spent fuel samples were dissolved in 8 M $HNO_3$ or its mixture with 14 M $HNO_3-0.05M$ HF. The dissolved solutions were filterred on membrane filter with $1.2{\mu}m$ pore size. The uraniums in the spiked and unspiked sample solutions were quantitatively adsorbed by anion exchange resin, AG 1X8 and eluted with 0.1 M HCl. The contents of uranium and its isotopes ($^{234}U$, $^{235}U$, $^{236}U$$^{238}U$) in the spent fuel samples were determined by isotope dilution mass spectrometric method using $^{233}U$ as spike. The spike reference solution was standarized by reverse isotope dilution mass spectrometry (R-IDMS) using natural and depleted uranium. The results from IDMS were in average relative difference of 0.34% when compared with those by the potentiometric titration method.

Preconcentration and Determination of Trace Copper(II) and Lead(II) in Aqueous Solutions by Adsorption on Ca-Alginate Bead (알긴산칼슘 비드 상 흡착에 의한 흔적량 구리(II)와 납(II)의 동시 농축 및 정량)

  • Choi, Jong-Moon;Choi, Sun-Do
    • Journal of the Korean Chemical Society
    • /
    • v.48 no.6
    • /
    • pp.590-598
    • /
    • 2004
  • The preconcentration and determination of trace Cu(II) and Pb(II) on calcium alginate beads in aqueous solution were studied. A calcium alginate beads were prepared by adding an alginic acid to sample solution contained Ca(II). Some following conditions were optimized: the pH of sample solution, amount of alginic acid, and stirring time for effective adsorption; the type and concentration of acid, and sonication time in an ultrasonic vibrator for the perfect de-sorption. A sample solution was prepared with Cu(II) and Pb(II) in DI water. And Ca(II) and ethanol was added into the sample solution. The pH of the final sample solution was controlled with buffer solution. The alginic acid were dispersed in the sample solution by a magnetic stirrer. This mixture was stored in room temperature for 30 min to form a calcium alginate. After the beads were filtered and washed on a membrane filter, the analytes were redissolved from the beads by an ultrasonic vibration of 10 minutes in 1.0M $HNO_3$ solution. The effect of diverse ions on the adsorption of analytes were studied. This procedure was applied for the analysis of two real samples. The recoveries in spiked samples were $90.4{\sim}104.3%$ for analytes.

Development of an Inverted Y-Shaped Strip for the Detection of Organophosphorus and Carbamate Residual Pesticides (유기인계 및 카바메이트계 농약 신속 검출을 위한 역 Y자 스트립의 개발)

  • Lee, Jeong-Eun;Kim, Sol-A;Park, Hyun-Jin;Mun, Hyoyoung;Shim, Won-Bo
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • The inverted Y-shaped strip detection method based on acetylcholinesterase (AChE) was developed for the rapid detection of organophosphorus and carbamate pesticides. The inactivation of AChE by organophosphorus and carbamate pesticides has been well known. The AChE catalyzes acetylthiocholine into thiocholine having (-) and (+) charges, and the (+) charge results in aggregation of gold nanoparticle (GNP). Malaoxon and carbofuran were used as standard organophosphorus and carbamate for the development of the inverted Y-shaped strip, respectively. In order to optimize the method, various angles of the Y-shaped strip, different types of nitrocellulose membrane, and concentration of AChE were tested as key parameters. The detection limit of the method was 10 ng/mL for both malaoxon and carbofuran pesticides. No cross-reaction was observed to other pesticides such as atrazine, cyanazine, simazine, bifenthrin, boscalid, metalaxyl, and chlorobenzilate. Recoveries from lettuce spiked when known concentrations of malaoxon and carbofuran were found ranging from 96.4 to 100.7% and 81 to 112.7%, respectively. This study suggests that the inverted Y-shaped strip method based on AChE may be a useful tool for the sensitive, specific, rapid detection of organophosphorus and carbamate pesticides in agricultural products.