• Title/Summary/Keyword: speed governor

Search Result 76, Processing Time 0.023 seconds

Fault Detection of Governor Systems Using Discrete Wavelet Transform Analysis

  • Kim, Sung-Shin;Bae, Hyeon;Lee, Jae-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.5
    • /
    • pp.662-673
    • /
    • 2012
  • This study introduces a condition diagnosis technique for a turbine governor system. The governor system is an important control system to handle turbine speed in a nuclear power plant. The turbine governor system includes turbine valves and stop valves which have their own functions in the system. Because a turbine governor system is operated by high oil pressure, it is very difficult to maintain under stable operating conditions. Turbine valves supply oil pressure to the governor system for proper operation. Using the pressure variation of turbine and governor valves, operating conditions of the turbine governor control system are detected and identified. To achieve automatic detection of valve status, time-based and frequency-based analysis is employed. In this study, a new approach, wavelet decomposition, was used to extract specific features from the pressure signals of the governor and stop valves. The extracted features, which represent the operating conditions of the turbine governor system, include important information to control and diagnose the valves. After extracting the specific features, decision rules were used to classify the valve conditions. The rules were generated by a decision tree algorithm (a typical simple method for data-based rule generation). The results given by the wavelet-based analysis were compared to detection results using time- and frequency-based approaches. Compared with the several related studies, the wavelet transform-based analysis, the proposed in this study has the advantage of easier application without auxiliary features.

Analysis of Dynamic Equilibrium Configuration of Speed Governor (조속기의 동적 평형위치 해석)

  • Kang, Juseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.10
    • /
    • pp.4733-4738
    • /
    • 2013
  • This paper proposes a method to obtain the dynamic equilibrium configuration of a constrained mechanical system by using multibody dynamic analysis. Dynamic equilibrium equations with independent coordinates are derived from the time-dependent constraint equations and dynamic equations of a multibody system. The Newton-Raphson method is used to find numerical solutions for nonlinear algebraic equations that are composed of the dynamic equilibrium and constraint equations. The proposed method is applied to obtain the dynamic equilibrium configuration of a speed governor, and the results are verified on the basis of the results from conventional dynamic analysis. Furthermore, vertical displacements at equilibrium configuration, which varied with the rotational velocity of the speed governor, are calculated, and design parameter analysis of the equilibrium configuration is presented.

A Study on the Estimation of the Load Torque in a Diesel Engine (디젤기관의 부하토오크 추정에 관한 연구)

  • 김병덕;하주식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.17 no.2
    • /
    • pp.29-35
    • /
    • 1993
  • Recent marine propulsion diesel engines tend to become slower in speed and longer in stroke for the higher engine efficiency, and in these long stroke and slow speed engines the digital governors are highly recommended to be used. But, in the present digital governors only the feedback of the engine rpm-signal is used for the engine speed control. If the load torque of the engine can be measured or estimated and the torque feedback loop is added to the present digital governor, it is expected that the speed control performance of the digital governor will be highly improved. In this paper, a new method is proposed to estimate the load torque of the diesel engine from the measured signals of fuel oil and rpm. And it is also suggested that the Kalman filter can be used for the estimation of engine torque.

  • PDF

A Study on the Reliability Improvement of Digital Governor System (디지털 조속기 시스템의 신뢰성 향상에 관한 연구)

  • 신천기;전일영;신남식;하달규;안병주;황춘석;노창주;김윤식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.05a
    • /
    • pp.375-381
    • /
    • 1999
  • In this study, turbine speed control algorithm is studied for Buk-Jeju steam turbine power plant and also digital governor system is designed for speed control of steam turbine in power plant. By using duplex I/O module, triplex CPU module, 2 out of 3 voting algorithm and adding self diagnostic ability, the reliability of the designed digital governor system can be acquired satisfactorily. Designed and manufactured digital governor system is implemented in a pilot steam turbine plant of 0.3kw output power Installed in Korea Maritime University. After a series of experiment the reliability and availability is confirmed and also stable operation is achieved.

  • PDF

A simulation test of lone rejection for steam turbine generator in nuclear power plant (원자력발전소 증기터빈 발전기의 부하차단 모의시험)

  • Choi, In-Kyu;Jeong, Tae-Woon;Lee, Ki-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2301-2303
    • /
    • 2003
  • A steam turnine in thermal/nuclear power plant drives generator and maintains it at rated speed using high temperature and high pressure steam energy. After synchronization in parallel with the power system, generator output increases according as the governor, that is the controller, increases steam flow into turbine. By the way, as the steam flow into turbine can not be reduced fast even though the electrical load is lost, the turbine gets into dangerous situation due to the increase of its speed. At this time, the duty of the turbine governor is to limit the speed to its overspeed trip setpoint by stopping the steam flow as soon as possible, the test of which is called load rejection test. It is introduced in this paper for a simulation test of generator load rejection to be implemented on the turbine governor in a 600MW nuclear power plant before its startup.

  • PDF

A Study on the Method of Gain Setting of Digital Governor by Dynamic Calculation for Marine Prime Movers (선박 주기관 디지털 거버너의 동적 게인 설정법에 관한 연구)

  • 강인철;최순만;최재성
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.251-259
    • /
    • 2002
  • The design concept of diesel engines for sea-going ships has been directed to Low-speed/Long-Stroke type to improve the efficiencies of combustion and propelling. But the time-delay property inevitable at such low speed engines gives much difficulties for governors to control the engine speed because they would be apt to go into unstable region especially when operating at low speed. The purpose of this paper is to study the problem of how the governor gain can be calculated dynamically in accordance with the variance of engine speed at least for an engine to be stable. In this study, the property of diesel engine was described as composed of combustion element including dead time and rotating element, and the ultimate gain for the speed control system to be located on the condition of stability limit was proposed based on the frequency characteristics. And the target gains with optimized stability also were proposed by giving proper margin to these ultimate conditions. The results were applied to a model system and the availability was confirmed to be satisfactory.

  • PDF

A Study On the Gain Setting of a Digital Governor for Marine Diesel Engines by Dynamic Calculation (선박 주기관 디지털 거버너의 동적 이득 설정에 관한 연구)

  • 강인철;최순만;최재성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.5
    • /
    • pp.565-572
    • /
    • 2002
  • The design concept of diesel engines for sea-going ships has been directed to Low-speed/Long-Stroke type to improve the efficiencies of combustion and propelling. But time-delay inevitable at low speed gives much difficulties for governors to control the engine speed because they would be apt to go into unstable region especially when operating at low speed. The purpose of this paper is to study the problem of how the governor gain can be calculated dynamically in accordance with the valiance of engine speed to locate the engine still on the properly stable condition. In this study, the property of diesel engine was described as composed of combustion element including dead time and rotating element, and the ultimate gain for the speed control system to be located on the condition of stability limit was proposed based on the frequency characteristics. And the target gains with optimized stability also were proposed by giving proper margin to these ultimate conditions. The results were applied to a model system and the availability was confirmed to be satisfactory.

Development of Intelligent Digital Governor System for Steam Turbine Generator in Buk-Cheju Thermal Power Plant (북제주 화력 발전소 스팀 터빈 발전기용 인텔리전트 디지털 조속기 개발)

  • 전일영;하달규;신명철;김윤식
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.608-613
    • /
    • 1999
  • This thesis aims at developing of a digita governor system for the steam turbine generator on the Buk-Cheju Thermal Power Plant of KEPCO. The steam turbine generator of the Buk-Cheju Thermal Power Plant is modelled. As a hardware platform, a triple modular system which is fitted 32-bit microprocessor of Motorola company to perform the digital governor system is used. The parameters of the PID controller algorithm in the speed control block is tuned on the basis of the estimated model.

  • PDF

Development of Turbine Generator Speed Droop Monitoring System Using Embedded (임베디드를 이용한 터빈 발전기 조정율 모니터링 시스템 개발)

  • Jang Min-Gyu;Jeon Il-Young;Lee Sung-Geun;Kim Yoon-Sik
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.910-913
    • /
    • 2004
  • This paper is about to develop a system to monitor speed droop rate characteristic of turbine governor for electric power plant. High quality electricity can be obtained, and so electricity supplier get more profit through it. Developed system presents basis of judgement of unusual system and proper maintenance time for the governor and power plant.

  • PDF

LFC Considering the Changing Rate of Governor Speed (조속기 입력의 변화율을 고려한 최적주파수 제어)

  • 박영문;유찬수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.3
    • /
    • pp.100-105
    • /
    • 1984
  • The optimal Load-Frequency Control law is presented with the performance criterion which includes the changing rate of governor speed. The authors propose two controllers. One is a dynamic controller using the method of state augmentation and the other is a constant gain controller with use of the trace function lemma by Kleinman. For a more practical realization, a reduced-order Luenberger observer is applied in order to identify unmeasurable states and power demand. The control schemees presented here are tested through the model developed by Elgerd, and the usefulness is demonstrated.

  • PDF