• Title/Summary/Keyword: spectrum requirements

Search Result 170, Processing Time 0.023 seconds

Computationally-Efficient Design of Training Symbol for Multi-Band MIMO-OFDM System (다중밴드를 사용하는 MIMO-OFDM에 적합한 연산효율적 훈련심볼의 설계)

  • Kim, Byung-Chan;Jeon, Tae-Hyun;Cheong, Min-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.5A
    • /
    • pp.479-486
    • /
    • 2008
  • In this paper, an efficient training symbol design with m-sequence is proposed for the MIMO-OFDM based next generation wireless transmission system which supports gigabits per second data rate. In the traditional blute force method, the preamble design is based on the case by case comparison with the system requirements. This paper discusses a training symbol design methodology for the MIMO-OFDM system based on the m-sequence which has been widely used in the spread spectrum communication areas due to its good correlation characteristics. Also the step-by-step design and performance verification method within the limited search space is discussed. The proposed method targets the design of the training symbol which satisfies system requirements for the packet based MIMO-OFDM wireless communication system including automatic gain control(AGC), timing synchronization, frequency and sampling offset estimation, and MIMO channel estimation.

CR Technology and Activation Plan for White Space Utilization (화이트 스페이스 활용을 위한 무선환경 인지 기술 및 활성화 방안)

  • Yoo, Sung-Jin;Kang, Kyu-Min;Jung, Hoiyoon;Park, SeungKeun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.11
    • /
    • pp.779-789
    • /
    • 2014
  • Cognitive radio (CR) technology based on geo-location database access approach and/or wideband spectrum sensing approach is absolutely vital in order to recognize available frequency bands in white spaces (WSs), and efficiently utilize shared spectrums. This paper presents a new structure for the TVWS database access protocol implementation based on Internet Engineering Task Force (IETF) Protocol to Access WS database (PAWS). A wideband compressive spectrum sensing (WCSS) scheme using a modulated wideband converter is also proposed for the TVWS utilization. The developed database access protocol technology which is adopted in both the TV band device (TVBD) and the TVWS database operates well in the TV frequency bands. The proposed WCSS shows a stable performance in false alarm probability irrespective of noise variance estimation error as well as provides signal detection probabilities greater than 95%. This paper also investigates Federal Communications Commision (FCC) regulatory requirements of TVWS database as well as European Telecommunications Standards Institute (ETSI) policy related to TVWS database. A standardized protocol to achieve interoperability among multiple TVBDs and TVWS databases, which is currently prepared in the IETF, is discussed.

Wine quality grading by near infrared spectroscopy.

  • Dambergs, Robert G.;Kambouris, Ambrosias;Schumacher, Nathan;Francis, I. Leigh;Esler, Michael B.;Gishen, Mark
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1253-1253
    • /
    • 2001
  • The ability to accurately assess wine quality is important during the wine making process, particularly when allocating batches of wines to styles determined by consumer requirements. Grape payments are often determined by the quality category of the wine that is produced from them. Wine quality, in terms of sensory characteristics, is normally a subjective measure, performed by experienced winemakers, wine competition judges or winetasting panellists. By nature, such assessments can be biased by individual preferences and may be subject to day-to-day variation. Taste and aroma compounds are often present in concentrations below the detection limit of near infrared (NIR) spectroscopy but the more abundant organic compounds offer potential for objective quality grading by this technique. Samples were drawn from one of Australia's major wine shows and from BRL Hardy's post-vintage wine quality allocation tastings. The samples were scanned in transmission mode with a FOSS NIR Systems 6500, over the wavelength range 400-2500 ㎚. Data analysis was performed with the Vision chemometrics package. With samples from the allocation tastings, the best correlations between NIR spectra and tasting data were obtained with dry red wines. These calibrations used loadings in the wavelengths related to anthocyanins, ethanol and possibly tannins. Anthocyanins are a group of compounds responsible for colour in red wines - restricting the wavelengths to those relating to anthocyanins produced calibrations of similar accuracy to those using the full wavelength range. This was particularly marked with Merlot, a variety that tends to have relatively lower anthocyanin levels than Cabernet Sauvignon and Shiraz. For dry white wines, calibrations appeared to be more dependent on ethanol characteristics of the spectrum, implying that quality correlated with fruit maturity. The correlations between NIR spectra and sensory data obtained using the wine show samples were less significant in general. This may be related to the fact that within most classes in the show, the samples may span vintages, glowing areas and winemaking styles, even though they may be made from only one grape variety. For dry red wines, the best calibrations were obtained with a class of Pinot Noir - a variety that tends to be produced in limited areas in Australia and would represent the least matrix variation. Good correlations were obtained with a tawny port class - these wines are sweet, fortified wines, that are aged for long periods in wooden barrels. During the ageing process Maillard browning compounds are formed and the water is lost through the barrels in preference to ethanol, producing “concentrated” darkly coloured wines with high alcohol content. These calibrations indicated heaviest loadings in the water regions of the spectrum, suggesting that “concentration” of the wines was important, whilst the visible and alcohol regions of the spectrum also featured as important factors. NIR calibrations based on sensory scores will always be difficult to obtain due to variation between individual winetasters. Nevertheless, these results warrant further investigation and may provide valuable Insight into the main parameters affecting wine quality.

  • PDF

Scaling Method of Earthquake Records for the Seismic Analysis of Tall Buildings (초고층 구조물의 지진해석을 위한 지진기록의 조정방법)

  • Kim, Tae-Ho;Park, Ji-Hyeong;Kim, Ook-Jong;Lee, Do-Bum;Ko, Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.5
    • /
    • pp.11-21
    • /
    • 2008
  • In recent years, time history analysis has been the method generally used for the seismic analysis of tall buildings with damping devices. When T is the natural period of the first vibration mode of the structure, the sum of the spectral acceleration of the earthquake ground motion is usually adjusted to that of the design response spectrum in the period ranging from 0.2T to 1.5T to meet the requirements of design code. However, when the ground motion is scaled according to the design code, the differences in the responses obtained by response spectrum analysis (RSA) and time history analysis (THA) of the structures increase as the natural period of the structure becomes longer. When time history analysis is performed by using ground accelerations that are scaled according to the design code, base shear is similar to that obtained from RSA, but other responses, such as displacements, drifts and member forces, are underestimated compared to RSA. If these results are adjusted by multiplying with the scale-up factor, the scaled responses become much smaller. Therefore, a scaling method of ground motions corresponding with the design code is proposed in this study, as a way of assisting structural engineers in generating artificial ground motions.

The Study on Improvement of Traffic Rho Performance in RF Transmitter of CDMA Handset (CDMA 단말기 RF 송신단의 Traffic Rho 성능 개선에 관한 연구)

  • 박희봉;황승훈;황금찬
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.4B
    • /
    • pp.624-628
    • /
    • 2000
  • In this paper, the phenomenon to show in CDMA handset in case of which CDMA handset do not meet Traffic Rho value of IS-98B specifications, which have minimum requirements of CDMA handset about electrical performance is analyzed. This paper proposed method to improve Traffic Rho through improving the matching circuit of TX IF SAW FILTER and deleting noise of LDO(Low Dropout Regulator) to generate 3.OV_TX in TX block. HP8924C(CDMA Mobile Station Tester Set) and HP8595E(Spectrum Analyzer) measures the improved CDMA waveform.

  • PDF

Fabrication of Plasmon Subwavelength Nanostructures for Nanoimprinting

  • Cho, Eun-Byurl;Yeo, Jong-Souk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.247-247
    • /
    • 2012
  • Plasmon subwavelength nanostructures enable the structurally modulated color due to the resonance conditions for the specific wavelength range of light with the nanoscale hole arrays on a metal layer. While the unique properties offered from a single layer of metal may open up the potential applications of integrated devices to displays and sensors, fabrication requirements in nanoscale, typically on the order of or smaller than the wavelength of light in a corresponding medium can limit the cost-effective implementation of the plasmonic nanostructures. Simpler nanoscale replication technologies based on the soft lithography or roll-to-roll nanoimprinting can introduce economically feasible manufacturing process for these devices. Such replication requires an optimal design of a master template to produce a stamp that can be applied for a roll-to-roll nanoimprinting. In this paper, a master mold with subwavelength nanostructures is fabricated and optimized using focused ion beam for the applications to nanoimprinting process. Au thin film layer is deposited by sputtering on a glass that serves as a dielectric substrate. Focused ion beam milling (FIB, JEOL JIB-4601F) is used to fabricate surface plasmon subwavelength nanostructures made of periodic hole arrays. The light spectrum of the fabricated nanostructures is characterized by using UV-Vis-NIR spectrophotometer (Agilent, Cary 5000) and the surface morphology is measured by using atomic force microscope (AFM, Park System XE-100) and scanning electron microscope (SEM, JEOL JSM-7100F). Relationship between the parameters of the hole arrays and the corresponding spectral characteristics and their potential applications are also discussed.

  • PDF

New site classification system and design response spectra in Korean seismic code

  • Kim, Dong-Soo;Manandhar, Satish;Cho, Hyung-Ik
    • Earthquakes and Structures
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • A new site classification system and site coefficients based on local site conditions in Korea were developed and implemented as a part of minimum design load requirements for general seismic design. The new site classification system adopted bedrock depth and average shear wave velocity of soil above the bedrock as parameters for site classification. These code provisions were passed through a public hearing process before it was enacted. The public hearing process recommended to modify the naming of site classes and adjust the amplification factors so that the level of short-period amplification is suitable for economical seismic design. In this paper, the new code provisions were assessed using dynamic centrifuge tests and by comparing the design response spectra (DRS) with records from 2016 Gyeongju earthquake, the largest earthquake in history of instrumental seismic observation in Korea. The dynamic centrifuge tests were performed to simulate the representative Korean site conditions, such as shallow depth to bedrock and short-period amplification characteristics, and the results corroborated with the new DRS. The Gyeongju earthquake records also showed good agreement with the DRS. In summary, the new code provisions are reliable for representing the site amplification characteristic of shallow bedrock condition in Korea.

MEASUREMENT OF IMPLEMENTATION LOSS FOR BRIT RECEIVER

  • Park Durk-Jong;Koo In-Hoi;Yang Hyung-Mo;Ahn Sang-Il;Kim Eun-Kyu
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.561-563
    • /
    • 2005
  • From the IF (Intermediated Frequency) loop-back test, BER (Bit Error Rate) degradation of processed data, HRIT (High Rate Information Transmission), is estimated by proposed measurement configuration. The specific parameters, likely data rate, FEC (Forward Error Correction), and modulation method, are based on the outcomes of SRR (System Requirements Review) which was held on 13-14 June 2005, in Toulouse. The proposed measurement procedure is that combined 70MHz modulated signal and noise is connected to the spectrum analyzer and receiver. The former measures the C/No (Carrier to Noise density ratio) and the latter estimates BER of FEC decoded data. Implementation loss can be obtained by subtracting measured BER from calculated BER which is also subtracted data rate from measured C/No. This test procedure is very simple and can be applied to assess the implementation loss of dedicated receiver for HRIT in the future.

  • PDF

Structural Studies of Copper(II)-Hippuryl-L-histidyl-L-leucine(HHL) Complex by NMR Methods

  • Lee Seong-Ran;Jun Ji-Hyun;Won Ho-Shik
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.10 no.1
    • /
    • pp.115-125
    • /
    • 2006
  • Hippuryl-L-histidyl-L-leucine(HHL) is widely used as a substrate of angiotensin converting enzyme(ACE) cleaving the neurotransmitter angiotensin(I) to the octapeptide angiotensin(II). The structure of the substrate molecules should provide information regarding the geometric requirements of the ACE active site. For the purpose of determination of in vivo reaction, metallo(Cu, Zn)-HHL complexes were synthesized and the degree of complex formation were identified by MALDITOF, ESI mass spectrometric analysis. Tn addition, the pH-dependent species distribution curves were obtained by potentiometric titration. Nitrogen atoms of imidazole ring and oxygen atom of caboxylate groups in the peptide chain were observed to be participated in the metal complex formation. After purification of complexes further structural characterization were made by utilizing UV-Vis, electrochemical methods and NMR. Complete NMR signal assignments were carried out by using 2D-spectrum techniques COSY, TOCSY, NOESY, HETCOR. A complex that two imidazole and carboxylate groups are asymmetrically participating to coordination mode was predicted to the solution-state structure of $Cu(II)-HHL_2$ based on $^{13}C-NMR$ signal assignment and NOE information.

  • PDF

Acoustic Loads Test of the Upper Stage of KSLV-I (소형위성발사체 상단부의 음향하중시험)

  • Chun, Young-Doo;Park, Jong-Chan;Chung, Eui-Seung;Park, Jung-Joo;Cho, Kwang-Rae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.224-227
    • /
    • 2007
  • This paper introduces the results of acoustic loads test conducted on the upper stage assembly of KSLV-I, which is the first Korea space launch vehicle. A launch vehicle and its payloads are subjected to severe acoustic pressure loading when they lift off and ascent during the transonic periods. Acoustic loadings are spreaded out broad frequncy-spectrum up to 10,000Hz. Acoustic loads are a primary source of structural random vibration of the upper stage and payloads. Therefore, in order to verify the structural integrity of the upper stage assembly of KSLV-I and the survivability of its components under severe random vibration environment, acoustic loads test is conducted in the high intensity acoustic chamber with 142dB (overall SPL). The results show the structural design and component random vibration specifications well meet with the environmental requirements.

  • PDF