• 제목/요약/키워드: spectrum and point spectrum

검색결과 504건 처리시간 0.029초

CONSTRAINTS ON A-DECAYING COSMOLOGY FROM OBSERVATIONAL POINT OF VIEW

  • KOMIYA ZEN;KAWABATA KIYOSHI;HIRANO KOICHI;BUNYA HIROSHI;YAMAMOTO NAOTAKA
    • 천문학회지
    • /
    • 제38권2호
    • /
    • pp.157-160
    • /
    • 2005
  • To constrain the values of the model parameters for the cosmological models involving the time-decaying $\Lambda$ term, we have computed sets of theoretical predictions for the N-m relation of galaxies as well as the CMB angular power spectrum: three types of variation, viz., ${\Lambda}{\propto} T^{-1},\;a^{-m}$, and $H^n$ are thereby assumed following Overduin & Cooperstock (1998), although we concentrate here on the discussion of the results obtained from the first type. Our results for the N-m relation indicate that the observed excess of the galaxy counts N in the faint region beyond the blue apparent magnitude 24 can be reasonably well accounted for with the value of ${\iota}$ in the range between 0.2 and 1. Furthermore, a comparison of our computational results of the CMB spectra with the observational data shows that the models with a mild degree of the $\Lambda$ term decay, viz., with the value of ${\iota}{\le}$0.4, are favorable. In this case, the age of our universe turns out to be larger than or equal to 14 Gyr, the lower limit inferred from some Uranium datings.

저선량에서의 TrueX 재구성 방법에 의한 유용성 평가 (The Evaluation of TrueX Reconstruction Method in Low Dose)

  • 오세문;김계환;김승정;이홍재;김진의
    • 핵의학기술
    • /
    • 제15권2호
    • /
    • pp.83-87
    • /
    • 2011
  • 최근 진단분야에서 PET/CT는 종양학 분야뿐만 아니라 심장 신경 등 여러 가지 분야에서 널리 활용되고 있다. PET/CT의 중요성이 높아지면서 영상의 질과 관련된 재구성 방법에 대한 연구도 활발히 진행되고 있다. 이 중 Siemens사의 TrueX 재구성 방법을 phantom 실험을 통해 Iterative 2D 재구성 방법과 비교 평가하여 임상적 유용성을 높이고자 하였다. 선량에 따른 영상을 비교 평가하기 위해 contrast ratio와 FWHM을 측정하였고 Biograph 40 True Point PET/CT (Siemens, Germany)를 사용하여 실험을 실시하였다. Contrast ratio를 구하기 위해 NEMA IEC PET body phantom (Data Spectrum Corp.)을 이용하였고, FWHM을 측정하기 위해 capillary tube를 사용하였다. 모든 영상은 10분씩 획득하였고, 영상 재구성은 현재 사용하고 있는 TrueX와 기존에 사용하던 Itertive 2D 알고리즘을 사용하였다. Iterative 2D는 임상에 적합한 parameter 조건을 적용하고 TrueX는 Siemens에서 권고하는 parameter를 적용하여 실험하였다. Capillary tube를 사용하여 FWHM을 측정한 결과, TrueX가 Iterative 2D 방식보다 낮게 나왔다. 저선량일수록 FWHM의 차이가 점점 커졌다. NEMA IEC PET body phantom을 사용하여 contrast ratio를 구한 결과, TrueX가 Itertive 2D보다 좋은 양상을 보였다. 그러나 선량에 따른 차이는 보이지 않았다. 본 연구에서는 영상 분석을 통해 TrueX가 Itertive 2D보다 contrast ratio와 spatial resolution이 높게 나타났다. 또한 TrueX를 통한 재구성 결과 저선량일수록 기존의 Iterative 2D보다 resolution은 좋은 양상을 보였고 contrast ratio는 큰 변화를 보이지 않았다. 즉 PET/CT에서 TrueX 재구성 기법이 환자의 피폭도 절감하고 질적으로 우수한 영상을 구현할 수 있어 임상적 이용가치가 높다고 생각된다.

  • PDF

다중 스펙트럼 머신비전 응용을 위한 CUDA SURF 기반의 영상 정렬 기법 (Image alignment method based on CUDA SURF for multi-spectral machine vision application)

  • 맹형열;김진형;고윤호
    • 한국멀티미디어학회논문지
    • /
    • 제17권9호
    • /
    • pp.1041-1051
    • /
    • 2014
  • In this paper, we propose a new image alignment technique based on CUDA SURF in order to solve the initial image alignment problem that frequently occurs in machine vision applications. Machine vision systems using multi-spectral images have recently become more common for solving various decision problems that cannot be performed by the human vision system. These machine vision systems mostly use markers for the initial image alignment. However, there are some applications where the markers cannot be used and the alignment techniques have to be changed whenever their markers are changed. In order to solve these problems, we propose a new image alignment method for multi-spectral machine vision applications based on SURF extracting image features without depending on markers. In this paper, we propose an image alignment method that obtains a sufficient number of feature points from multi-spectral images using SURF and removes outlier iteratively based on a least squares method. We further propose an effective preliminary scheme for removing mismatched feature point pairs that may affect the overall performance of the alignment. In addition, we reduce the execution time by implementing the proposed method using CUDA based on GPGPU in order to guarantee real-time operation. Simulation results show that the proposed method is able to align images effectively in applications where markers cannot be used.

원통형 음향 홀로그라피를 이용한 성덕대왕 신종의 방사음장 특성 분석 (An analysis of the Sound Radiation Characteristics of the King Song-Dok Bell Using Cylindrical Acoustic Holography)

  • 김양한;김시문
    • 한국음향학회지
    • /
    • 제16권4호
    • /
    • pp.94-100
    • /
    • 1997
  • 성덕대왕 신종의 방사 음장 특성을 분석하기 위하여 30개의 마이크로폰으로 구성된 어레이를 이용하여 360개의 위치에서 음압을 측정한 후 원통형 음향 홀로그라피 방법을 적용하여 시간, 주파수별로 음장 해석을 행하였다. 타종 직후, 신종에서 방사되는 음장은 넓은 주파수 영역(800Hz까지 해석)에 걸쳐 고른 분포를 가지나 시간이 지남에 따라 고주파 성분은 급격히 감쇠하여 약 10초 이후에는 저주파 성분만이 존재한다. 마찬가지로 시간에 따른 음압 신호를 살펴보면 초기에 여러 성분의 모우드들이 중첩되어 복잡한 모양을 하고 있으나 10초 이후에는 한쌍의 저주파 성분(64.06Hz, 64.38Hz)에 의한 맥놀이 현상이 나타남을 확인할 수 있다. 이 맥놀이에 의한 여음이 초기의 화려하면서 장엄한 소리와 어우러져 신종만의 독특한 소리를 나타낸다. 맥놀이 현상은 종의 축에 대한 비대칭 현상에 의해 근접한 고유진동수를 가지기 때문에 발생하며 다른 고주파 성분에서도 쌍으로 존재하는 고유진동수를 관찰할 수 있다. 저주파 모우드의 경우 쌍으로 존재하는 방사 음장 형태는 길이 방향 절선 간격의 반에 해당되는 각도만큼 회전되어 나타난 것을 제외하고는 동일함을 알 수 있으며 고주파 모우드의 경우는 이보다 복잡한 모양을 이루고 있다.

  • PDF

DIAGNOSTICS OF PLASMA INDUCED IN Nd:YAG LASER WELDING OF ALUMINUM ALLOY

  • Kim, Jong-Do;Lee, Myeong-Hoon;Kim, Young-Sik;Seiji Katayama;Akira Matsunawa
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2002년도 Proceedings of the International Welding/Joining Conference-Korea
    • /
    • pp.612-619
    • /
    • 2002
  • The dynamic behavior of Al-Mg alloys plasma was very unstable and this instability was closely related to the unstable motion of keyhole during laser irradiation. The keyhole fluctuated both in size and shape and its fluctuation period was about 440 ${\mu}{\textrm}{m}$. This instability has been estimated to be caused by the evaporation phenomena of metals with different boiling point and latent heats of vaporization. Therefore, the authors have conducted the spectroscopic diagnostics of plasma induced in the pulsed YAG laser welding of Al-Mg alloys in air and argon atmospheres. In the air environment, the identified spectra were atomic lines of Al, Mg, Cr, Mn, Cu, Fe and Zn, and singly ionized Mg line, as well as strong molecular spectrum of AlO, MgO and AIH. It was confirmed that the resonant lines of Al and Mg were strongly self-absorbed, in particular in the vicinity of pool surface. The self-absorption of atomic Mg line was more eminent in alloys containing higher Mg. These facts showed that the laser-induced plasma was relatively a low temperature and high density metallic vapor. The intensities of molecular spectra of AlO and MgO were different each other depending on the power density of laser beam. Under the low power density irradiation condition, the MgO band spectra were predominant in intensity, while the AlO spectra became much stronger in higher power density. In argon atmosphere the band spectra of MgO and AlO completely vanished, but AlH molecular spectra was detected clearly. The hydrogen source was presumably the hydrogen solved in the base Metal, absorbed water on the surface oxide layer or H$_2$ and $H_2O$ in the shielding gas. The temporal change in spectral line intensities was quite similar to the fluctuation of keyhole. The time average plasma temperature at 1 mm high above the surface of A5083 alloy was determined by the Boltzmann plot method of atomic Cr lines of different excitation energy. The obtained electron temperature was 3, 280$\pm$150 K which was about 500 K higher than the boiling point of pure aluminum. The electron number density was determined by measuring the relative intensities of the spectra1lines of atomic and singly ionized Magnesium, and the obtained value was 1.85 x 1019 1/㎥.

  • PDF

마그네트론 스퍼터링법을 이용한 Indium-Tin Oxide 박막의 제작과 그 특성에 관한 연구 (A Study on the Fabrication and Characteristics of ITO Thin Film Deposited by Magnetron Sputtering Method)

  • 조길호;김여중;김성종;문경만;이명훈
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권6호
    • /
    • pp.61-69
    • /
    • 2000
  • Indium-Tin Oxide (ITO) films were prepared on the commercial glass substrate by the Magnetron Sputtering method. The target was a 90wt.% $In_2O_3$-10wt.% $SnO_2$with 99.99% purity. The ITO films deposited by changing the partial pressure of oxygen gas ($O_2$/(Ar+$O_2$)) of 2, 3 and 5% as well as by changing the substrate temperature of $300^{\circ}C$ or $500^{\circ}C$. The influence of substrate pre-annealing and pre-cleaning on the quality of ITO film were examined, in which the substrate temperature was $500^{\circ}C$ and oxygen partial pressure was 3%. The characteristics of films were examined by the 4-point probe, Hall effect measurement system, SEM, AFM, Spectrophotometer, and X-ray diffraction. The optimum ITO films have been obtained when the substrate temperature is $500^{\circ}C$ and oxygen partial pressure is 3%. At optimum condition, the film showed transmittance of 81%, sheet resistivity of $226\Omegatextrm{cm}^2$, resistivity($\rho$) of $5.4\times10^{-3}\Omega$cm, carrier concentration of $1.0\times10^{19}cm^{-3}$, and carrier mobility of $150textrm{cm}^2$Vsec. From XRD spectrum, c(222) plane was dominant in the case of substrate temperature at $300^{\circ}C$, without regarding to oxygen partial pressure. However, in the case of substrate temperature at $500^{\circ}C$, c(400) plane was grown together with c(222) plane, only for oxygen partial pressure of 2 and 3%. In both case of chemical and ultrasonic cleaning without pre-annealing the substrate, it showed much almost same sheet resistivity, resistivity($\rho$), transmittance, carrier concentration, and carrier mobility. In case of $500^{\circ}C$/60min pre-annealing before ITO film deposited, both transimittance and carrier mobility are better than no pre-annealing, because pre-annealing is supposed to remove alkari ions diffusion from substrate. ITO film deposited on the Corning 0080 sybstrate showed a little bit better sheet resistivity, resistivity($\rho$), transimittance, carrier concentration than the film deposited on commercial glass. But no differences between Corning substrate and pre-annealed commercial glass substrate are found.

  • PDF

가전제품 전자파 현황 및 차폐재에 의한 감쇄 효과 (Electromagnetic Wave and EMF Attenuation by Shielding Materials in home appliances)

  • 조재철;박재환
    • 예술인문사회 융합 멀티미디어 논문지
    • /
    • 제9권6호
    • /
    • pp.711-718
    • /
    • 2019
  • 전자파 측정기와 스펙트럼 분석기를 통하여 가정에서 사용되고 있는 여러 종류의 가전제품에서 발생하는 전자파 발생 거동을 조사하였다. 전자레인지 동작 중에 30cm 떨어진 지점에서 측정된 전자파 전력은 8~11mW/㎡ 범위로 측정되었고 저주파 자기장의 강도는 60~80mG, 전기장 강도는 150~160V/m로 측정되었다. 스마트폰 무선 충전 패드의 경우 10cm 떨어진 지점에서 전자파 전력 0.4mW/㎡, 전기장 160V/m, 자기장 1mG로 측정되었다. 전자레인지 및 무선 충전 패드의 경우 10cm 이내로 근접하여 사용할 경우 전기장 크기가 인체 보호 기준을 초과하는 큰 값으로 측정되었으며 인체 유해성이 우려된다. 한편 TV, 헤어드라이어, 냉장고 등의 가전제품은 전자파, 전기장, 자기장 모두 매우 낮은 수준으로 나타났으며 인체 유해성은 없는 것으로 보인다. 전자파 차폐재의 경우 금속 재질의 Cu 패브릭과 메탈 포일은 높은 수준의 전자파 차단 성능을 나타내었으나, 폴리머 필름의 경우는 전자파 차단 특성이 낮은 수준으로 나타났다.

자체-감지능 및 광투과도를 지닌 CNT 및 ITO/PET 다기능성 나노복합소재의 계면 조절 연구 (Interfacial Control of Multi-functional CNT and ITO/PET Nanocomposites having Self-Sensing and Transparency)

  • 왕작가;권동준;구가영;박종만
    • Composites Research
    • /
    • 제24권1호
    • /
    • pp.45-50
    • /
    • 2011
  • 자체-감지능 있는 다기능성 나노복합소재를 위해, 투명하고 전도성 있는 카본나노튜브 (CNT)로 코팅된 폴리에틸렌 테레프탈레이트(PET)를 함침 방법으로 제조하였다. CNT 코팅의 전기적 광학적 특정의 변화는 함침 횟수와 CNT용액의 농도에 주로 의존하였다. 결과적으로, CNT 코팅의 표면저항과 투과도는 제조공정의 변수들에 따라 예민하게 조절되었다. CNT 코팅의 표면저항은 4점법과 이중 배열법에 의해 측정되었으며, 광학적 투과도는 UV 스펙트럼을 사용하여 평가하였다. CNT 코팅의 표면특성을 측정한 정적 및 동적 접촉각은 상호 일치함을 보여주었다. 함침 코팅수가 증가함에 따라, CNT코팅한 PET의 표면저항은 현저하게 저하했으나, 투명도는 CNT 네트워크의 특성으로 거의 감소하지 않았다. CNT와 인듐틴옥사이드 (ITO)의 계면 및 전기적 특성들은 피로 시험을 통하여 비교하였다. CNT는 2000회 반복 후에도 표면저항의 변화가 없는 반면에, ITO는 1000회 반복까지 표면저항의 급격한 증가를 보여주었다가 안정화하였다. 이는 형상비가 큰 CNT는 전기 접촉점을 계속 유지하는 반면에, 취성이 있는 ITO는 미세 균열이 발생하여 전지 접촉점을 많이 상실하기 때문이다.

제강 슬래그 및 순환골재를 사용한 순환 아스팔트 혼합물의 장기 공용성 평가 (Long-Term Performance Evaluation on the Recycled Asphalt Concrete Using the Steel Slag and Reclaimed Asphalt Pavement Aggregates)

  • 박경원;장동복;이종민;강병화;김형배
    • 한국건설순환자원학회논문집
    • /
    • 제9권4호
    • /
    • pp.633-641
    • /
    • 2021
  • 본 연구에서는 철강산업 부산물인 제강슬래그 및 폐아스팔트 콘크리트포장 파쇄물인 순환골재를 사용하여 아스팔트 혼합물용 천연골재를 대체 가능성을 파악하고 제강슬래그를 활용한 아스팔트 혼합물의 공용성 평가를 수행하였다. 일반 WC-2와 Slag WC-2(R)에 대한 평가는 동일한 조건으로 수행하였으며, 수행기관은 국가 공인시험기관(KTR) 및 한국도로학회로 각 기관의 연구용역을 통해 평가되었다. 동적안정도, 동탄성계수, 피로균열 시험결과 슬래그 아스팔트 혼합물이 일반 아스팔트 혼합물에 비해 각각 140%, 저온·고온 487·350%, Low·Middle·High Stress Level 32·325·900% 증가하는 것으로 조사되었다. 함부르크 휠 트래킹 시험결과 두 가지 혼합물의 수분저항성이 우수한 것으로 조사되었으나, 슬래그 아스팔트 혼합물 시험결과에 변곡점이 없고 변위발생량이 낮아 일반 혼합물 대비 우수한 것으로 조사되었다. 장기공용성 평가(APT) 결과 슬래그 아스팔트 혼합물에서 소성변형 발생량이 6.5% 적게 발생하였으며, 표층, 기층 및 하부층의 압축량을 분석한 결과 슬래그 포장도로의 표층 소성변형 저항성이 45% 높게 조사되었다.

Surface Characteristics of Type II Anodized Ti-6Al-4V Alloy for Biomedical Applications

  • 이수원;정태곤;양재웅;정재영;박광민;정용훈
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2017년도 춘계학술대회 논문집
    • /
    • pp.77-77
    • /
    • 2017
  • Titanium and its alloys offer attractive properties in a variety of applications. These are widely used for the field of biomedical implants because of its good biocompatibility and high corrosion resistance. Titanium anodizing is often used in the metal finishing of products, especially those can be used in the medical devices with dense oxide surface. Based on SAE/AMS (Society of Automotive Engineers/Aerospace Material Specification) 2488D, it has the specification for industrial titanium anodizing that have three different types of titanium anodization as following: Type I is used as a coating for elevated temperature forming; Type II is used as an anti-galling coating without additional lubrication or as a pre-treatment for improving adherence of film lubricants; Type III is used as a treatment to produce a spectrum of surface colours on titanium. In this study, we have focused on Type II anodization for the medical (dental and orthopedic) application, the anodized surface was modified with gray color under alkaline electrolyte. The surface characteristics were analyzed with Focused Ion Beam (FIB), Scanning Electron Microscopy (SEM), surface roughness, Vickers hardness, three point bending test, biocompatibility, and corrosion (potentiodynamic) test. The Ti-6Al-4V alloy was used for specimen, the anodizing procedure was conducted in alkaline solution (NaOH based, pH>13). Applied voltage was range between 20 V to 40 V until the ampere to be zero. As results, the surface characteristics of anodic oxide layer were analyzed with SEM, the dissecting layer was fabricated with FIB method prior to analyze surface. The surface roughness was measured by arithmetic mean deviation of the roughness profile (Ra). The Vickers hardness was obtained with Vickers hardness tester, indentation was repeated for 5 times on each sample, and the three point bending property was verified by yield load values. In order to determine the corrosion resistance for the corrosion rate, the potentiodynamic test was performed for each specimen. The biological safety assessment was analyzed by cytotoxic and pyrogen test. Through FIB feature of anodic surfaces, the thickness of oxide layer was 1.1 um. The surface roughness, Vickers hardness, bending yield, and corrosion resistance of the anodized specimen were shown higher value than those of non-treated specimen. Also we could verify that there was no significant issues from cytotoxicity and pyrogen test.

  • PDF