• 제목/요약/키워드: spectrum and point spectrum

Search Result 504, Processing Time 0.022 seconds

Real-Time H/W Implementation of RPE-LTP Speech Coder for Digital Mobile Communications (디지틀 이동 통신용 RPE-LTP 음성 부호화기의 실시간 H/W 구현)

  • 김선영;김재공
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.1
    • /
    • pp.85-100
    • /
    • 1991
  • In the discussion of digital mobile communication systems the speech coder based on the high quality low bit rate is an essential part of topics to overcome the limited availability of radio spectrum, which will enhance the communication services. In this paper we present the implementation and performance evaluation of 13kbps RPE LTP speech coder. An implementation of a real time full duplex coder with 75% of DSP loading rate using a single DSP chip has been shown, and also the fixed point simulations for H/W implementation has been performed. Finally, analysis result for relative bit importance of each transmitting parameter has been shown for channel coding.

  • PDF

Effect of Source Line Location on Lift-off Acoustic Loads of a Launch Vehicle (음원 분포선 위치가 발사체 이륙 음향하중에 미치는 영향)

  • Choi, Sang-Hyeon;Ih, Jeong-Guon;Lee, Ik-Jin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.8
    • /
    • pp.539-545
    • /
    • 2015
  • Intense acoustic load is generated when a launch vehicle lifts off, causing the damaging vibrations at the launch vehicle or satellite within the fairing. This paper is concerned with the prediction of lift-off acoustic loads for a launch vehicle. As a test example, the lift-off acoustic load on the Korean launch vehicle, NARO, is predicted by the existing calculation tool, the modified Eldred's second method. Although the acoustic sources, assumed as point sources, are to be located along the center line of the exhaust plume when using the Eldred's prediction method, the exact location of the deflected center line of exhaust gas flow is not usually known. To search for the most appropriate source positions, six models of source line distribution are suggested and the acoustic load prediction results from these models are compared with the actual measurements. It is found that the predicted sound pressure spectrum of the Naro is the most similar to the measured data when the centerline of the turbulent kinetic energy contour is used as the source line.

A study on the Lloyd's mirror effect on the underwater radiated noise for the underwater vehicle (수중운동체 방사소음의 로이드 미러 효과 연구)

  • Kang, Seung-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.4
    • /
    • pp.314-319
    • /
    • 2021
  • The measurement of the Underwater Radiated Noise (URN) for the underwater vehicle should consider both the acoustic interference due to the surface reflection and the calculation of the Closet Point of Approach (CPA). In this paper, I tried to analyze the underwater vehicle's URN using the Lloyd's mirror effect. First, the theoretical Lloyd's mirror pattern was compared with the sea trial result, and the sea trial results corresponded well with the theoretical predicted pattern. And then the CPA distance could be estimated by the Lloyd's mirror pattern. As a results, acoustic source level shows the spectral fluctuation due to the acoustic interference of the Lloyd's mirror effect.

A new approach for modeling pulse height spectra of gamma-ray detectors from passing radioactive cloud in a case of NPP accident

  • R.I. Bakin;A.A. Kiselev;E.A. Ilichev;A.M. Shvedov
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4715-4721
    • /
    • 2022
  • A comprehensive approach for modeling the pulse height spectra of gamma-ray detectors from passing radioactive cloud in a case of accident at NPP has been developed. It involves modeling the transport of radionuclides in the atmosphere using Lagrangian stochastic model, WRF meteorological processor with an ARW core and GFS data to obtain spatial distribution of radionuclides in the air at a given moment of time. Applying representation of the cloud as superposition of elementary sources of gamma radiation the pulse height spectra are calculated based on data on flux density from point isotropic sources and detector response function. The proposed approach allows us to obtain time-dependent spectra for any complex radionuclide composition of the release. The results of modeling the pulse height spectra of the scintillator detector NaI(Tl) Ø63×63 mm for a hypothetical severe accident at a NPP are presented.

A study imitating human auditory system for tracking the position of sound source (인간의 청각 시스템을 응용한 음원위치 추정에 관한 연구)

  • Bae, Jeen-Man;Cho, Sun-Ho;Park, Chong-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.878-881
    • /
    • 2003
  • To acquire an appointed speaker's clear voice signal from inspect-camera, picture-conference or hands free microphone eliminating interference noises needs to be preceded speaker's position automatically. Presumption of sound source position's basic algorithm is about measuring TDOA(Time Difference Of Arrival) from reaching same signals between two microphones. This main project uses ADF(Adaptive Delay Filter) [4] and CPS(Cross Power Spectrum) [5] which are one of the most important analysis of TDOA. From these analysis this project proposes presumption of real time sound source position and improved model NI-ADF which makes possible to presume both directions of sound source position. NI-ADF noticed that if auditory sense of humankind reaches above to some specified level in specified frequency, it will accept sound through activated nerve. NI-ADF also proposes practicable algorithm, the presumption of real time sound source position including both directions, that when microphone loads to some specified system, it will use sounds level difference from external system related to sounds of diffraction phenomenon. In accordance with the project, when existing both direction adaptation filter's algorithm measures sound source, it increases more than twice number by measuring one way. Preserving this weak point, this project proposes improved algorithm to presume real time in both directions.

  • PDF

A Study on the Measurement of Vibration Mode Shape using Holographic interferometry (홀로그래픽 간섭법을 이용한 진동모드의 계측에 관한 연구)

  • 김광래
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.3
    • /
    • pp.130-135
    • /
    • 2000
  • In this study the vibration behavior of the stiffened double cylinder was experimently analyzed. Due to the complex structure of the double cylinder the outside cylinder frequency responses to the exciting forces applied on various posi-tions were analyzed by using spectrum analyzer in conjunction with an accelerometer and the natural frequencies were obtained. The technique of time-averaged holographic interferometry is applied to study the vibration characteristics of outside cylinder with stiffening T frame. The experimental data showed that the T frame had salient effect of damping on the testing structure at most of resonances. however the experimental results also revealed interesting phenomenon. At some particular frequencies the T frame. The experimental data showed that the T frame had salient effect of damping on the testing structure at most of resonances. However the experimental results also revealed interesting phenomenon. At some particular frequencies the T frame seemed to behave as a transmitter. In addition it has been successfully demon-started that optical method such as holographic interferometry is well suited for the identification of mode shapes. They can give us a whole-field non-contact measurement instead of the point-wise measurement by accelerometer in classical modal testing.

  • PDF

The Characteristics of Electromagnetic waves by surface discharge in solid insulator (고체절연체의 연면방전에 따른 방사전자파 분포 특성)

  • Kim, Chung-Hyun;Lee, Hyun-Dong;Kim, Ki-Chai;Park, Won-Zoo;Lee, Kwang-Sik;Lee, Dong-In;Lee, Chun-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1862-1864
    • /
    • 2000
  • Recently diagnostic techniques have been investigated to detect a partial discharge(PD) associated with a dielectric material defect in a high-voltage electrical apparatus. Among the PD measuring method, detecting electromagnetic wave generated by PD is one of the most effective method because PD radiates wide frequency of electromagnetic wave up to UHF. From the above points of view, we have investigated the polarization and distance characteristics of electromagnetic wave radiated by an insertion of solid insulators between needle-plane electrodes in the air. According to the magnitude of applied voltage, the frequency spectrum of radiated electromagnetic waves were increased about under 100(MHz), compared with background noise. The electromagnetic wave magnitude is attenuated about 4$\sim$7.6[dB] at the point 3[m] away from PD.

  • PDF

Design and Analysis of 4D-8PSK-TCM System Considering the Nonlinear HPA Environment (비선형 HPA 환경을 고려한 4D-8PSK-TCM 시스템의 설계 및 분석)

  • An, Changyoung;Ryu, Sang-Burm;Lee, Sang-Gyu;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.4
    • /
    • pp.299-307
    • /
    • 2018
  • Considering a nonlinear high power amplifier(HPA) and a predistorter, we have designed a four-dimensional 8-ary phase shift keying trellis-coded modulation(4D-8PSK-TCM) system, which is recommended for X-band satellite communications. Subsequently, we have evaluated and analyzed the spectrum, constellation characteristics, and BER performance of the system. In satellite communications, owing to the limited power, nonlinear characteristics that determine the operating point of the HPA must be analyzed because the HPA consumes high power. We herein report the design of the 4D-8PSK-TCM system, with efficiencies of 2 and 2.25 bits/channel-symbol. The simulation results confirmed that a 0.35 roll-off value is effective, considering the low peak-to-average power ratio(PAPR) characteristic and the narrow occupation bandwidth of the spectrum. It also confirmed that approximately 15~20 dB of output backoff(OBO) value is required at the HPA when the predistorter is not used, and approximately 1 dB of the OBO value is required when the predistorter is used.

Prescription Pattern of 1 Year Clozapine Maintenance and Augmentation Agents in Schizophrenia Spectrum Disorders (조현병 스펙트럼 장애의 1년 유지 치료에서 클로자핀과 병용 치료제의 처방 양상 분석)

  • Kim, Jaewon;Kim, Se Hyun;Jang, Jin-Hyeok;Moon, Sun-Young;Kang, Tae Uk;Kim, Minah;Kwon, Jun Soo
    • Korean Journal of Biological Psychiatry
    • /
    • v.28 no.2
    • /
    • pp.50-57
    • /
    • 2021
  • Objectives Clozapine is the most effective atypical antipsychotic agent for the treatment-resistant schizophrenia (TRS), however, only 40%-70% of TRS patients respond to clozapine. Moreover, TRS encompasses various symptom dimensions. Therefore, augmentation with other medications for clozapine is frequently applied. However, the prescription pattern of clozapine and combined medications in Korea is yet to be examined. This study aims to investigate the maintenance treatment pattern of clozapine and augmentation agents in one Korean tertiary hospital. Methods The patients with schizophrenia spectrum disorders under clozapine maintenance, defined as one-year clozapine continuation, were subjected for analysis. Medication data at one-year time-point after clozapine initiation was extracted and analyzed. Results Among total 2897 patients having clozapine prescription experience from January 2000 to December 2018, 1011 patients were on clozapine maintenance. The mean age of clozapine initiation was 30.2 ± 11.3 years, and the maintenance dose of clozapine was 217.8 ± 124.3 mg/day. Combination rate of antipsychotics, mood stabilizers, and antidepressants were 43.5%, 25.3%, 38.6%, respectively. Most frequently prescribed drugs in each category were aripiprazole, valproate, and sertraline. Olanzapine equivalent dose of combined antipsychotics was 10.4 ± 7.7 mg/day. Male patients were prescribed higher dose of combined antipsychotics and higher rate of antidepressants. Female patients had later onset of clozapine prescription. Patients with two or more combined antipsychotics were prescribed higher dose of clozapine and higher rate of antidepressants compared to patients with one combined antipsychotic. Conclusions Taken together, among the patients taking clozapine, a substantial rate of patients were under polypharmacy. The present findings based on the real-world prescription pattern could provide the valuable clinical information on the treatment of TRS-related conditions.

The Effect of the Telephone Channel to the Performance of the Speaker Verification System (전화선 채널이 화자확인 시스템의 성능에 미치는 영향)

  • 조태현;김유진;이재영;정재호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.12-20
    • /
    • 1999
  • In this paper, we compared speaker verification performance of the speech data collected in clean environment and in channel environment. For the improvement of the performance of speaker verification gathered in channel, we have studied on the efficient feature parameters in channel environment and on the preprocessing. Speech DB for experiment is consisted of Korean doublet of numbers, considering the text-prompted system. Speech features including LPCC(Linear Predictive Cepstral Coefficient), MFCC(Mel Frequency Cepstral Coefficient), PLP(Perceptually Linear Prediction), LSP(Line Spectrum Pair) are analyzed. Also, the preprocessing of filtering to remove channel noise is studied. To remove or compensate for the channel effect from the extracted features, cepstral weighting, CMS(Cepstral Mean Subtraction), RASTA(RelAtive SpecTrAl) are applied. Also by presenting the speech recognition performance on each features and the processing, we compared speech recognition performance and speaker verification performance. For the evaluation of the applied speech features and processing methods, HTK(HMM Tool Kit) 2.0 is used. Giving different threshold according to male or female speaker, we compare EER(Equal Error Rate) on the clean speech data and channel data. Our simulation results show that, removing low band and high band channel noise by applying band pass filter(150~3800Hz) in preprocessing procedure, and extracting MFCC from the filtered speech, the best speaker verification performance was achieved from the view point of EER measurement.

  • PDF